Features

/square4 Conforms to EN 300 220-2 and EN 301 489-3 /square4 High performance Fractional N (Sigma-Delta) Synthesizer with TCXO /square4 Vibration resistant (negligible microphony) /square4 Data rates up to 10 kbps for standard module /square4 Usable range over 500m (with suitable aerials and matching receiver) /square4 Fully screened. Very low profile /square4 Feature-rich interface (analogue and digital baseband) /square4 Re-programmable via RS232 interface /square4 Low power requirements

Applications

/square4 Keyfobs and other hand held terminals /square4 Small form factor data loggers /square4 Industrial telemetry and telecommand /square4 In-building environmental monitoring and control /square4 Covert, high-end security devices /square4 Unobtrusive fire alarm sensors /square4 Heavy vehicle/machinery controls Technical Summary /square4 Operating frequency: 433.875-434.650MHz (EU band) 458.525 - 459.1MHz (UK band) /square4 Other custom UHF bands /square4 850-950MHz version (MTX3) also available /square4 4 parallel channels (also fully controllable via serial port) /square4 Transmit power: +10dBm (10mW) /square4 Supply range: 3.1 – 15V (will operate down to 2.9V ) /square4 Current consumption: 20mA @ 10mW /square4 Data bit rate: 10kbps max. (standard module) /square4 Serial configuration by inverted RS232 at 3V CMOS level /square4 Size: 23 x 12.5 x 7 mm Evaluation platforms : NBEK + matching carrier board Figure 1: MTX2-434.650-10 UHF Narrow Band FM sub -miniature transmitter Hartcran House, 231 Kenton Lane, Harrow, Middlesex, HA3 8RP, England Tel: +44 (0) 20 8909 9595, Fax: +44 (0) 20 8909 2233, www.radiometrix.com Issue 2, 28 May 2014MTX2

Radiometrix Ltd MTX2 Data Sheet page 2 Figure 2: MTX2 block diagram

Radiometrix Ltd MTX2 Data Sheet page 3 Figure 3: MTX2 footpint (top view) Pin description – MTX2 Pin Name Function

1 RF RF output (to antenna)

2 GND Ground

3 VCC 2.9V – 15V DC power supply (@ 10mW)

4 EN/PGM Transmit Enable (active high)

Serial frequency programming / configuration 1 5 TXD DC coupled input for 3V CMOS logic. R in =47k Ω

6 P1 Parallel Channel select

7 P0 Parallel Channel select LSB

8 GND Ground

Notes: 1. Serial programming is by the application of a lo gic level inverted RS232 datastream at 9600 baud to the EN/PGM pin. The unit must be fully enabled (5mS after the rising edge of the EN signal) before a programming burst can be properly decoded. 2. Channel select inputs have pull-ups (50k Ω ) to 3V internal rail. Do not exceed 3V logic levels on this port. Do not drive pins high when unit is turned off 3. Channel select inputs are active low. If unused, allow them to remain unconnected 4. EN has a 100k Ω pulldown resistor 5. All pins are on a 2mm grid 6. In the 'off' state there are no transmit state s purii 7. The unit will operate (with marginally reduced s pecifications and lower (6-8mW) output power) from a 2.9 – 3.0V rail. This must be well regulated and without noise or ripple, as in this state the unit's internal regulator no longer operates, and provides no supply rejection. 8. Switching time as controlled by the EN pin is <5 ms, but when power is first applied to the unit there is a 20ms long “calibration” period before the transmitter becomes active 9. 25mW version uses 3v3 internal rail (not 3v0), b ut is otherwise identical

Radiometrix Ltd MTX2 Data Sheet page 4 Condensed specifications Frequency 433MHz EU band, and 458MHz UK band Other custom UHF bands Frequency stability ±1.5kHz Channel spacing 25kHz, 20KHz or 12.5KHz (to order) Number of channels 4 channels controlled by parallel port, or 256 sequential, or direct control of PLL device via RS232 interface Operating temperature -20 ºC to +70 ºC (Storage -3 0 ºC to +70 ºC) Spurious radiations Compliant with ETSI EN 300 220- 3 and EN 301 489-3 Transmitter Output power +10dBm (10mW) ±1dB +14dBm (25mW) version available Peak deviation ±3kHz TX on switching time 5ms from EN transition Modulation type FSK (F3D) TX modulation bandwidth DC – 5kHz (3V CMOS compatib le) Adjacent channel TX power <-37dBm TX spurious <-45dBm (no RF output in Standby) Supply Voltage 3.1V – 15V (usable down to 2.9v) Current 20mA @ 10mW (nominal) <3 µ A standby (EN low or floating) Inputs data (CMOS/TTL compatible) Size 23 x 12.5 x 7mm Interface User 6 pin, 2mm pitch header RF 2pin 2mm pitch hea der Recommended PCB hole size 1mm

Radiometrix Ltd MTX2 Data Sheet page 5 Channel Programming It is useful at this point to describe how an MTX2 defines it's operating frequency: At the heart of the device is a fractional N synthesizer locked to a high stability VCXO. The minimum step size of this PLL is (approximately) 12.4Hz The data required by the PLL consists of two coefficients: the integer and the fraction. Output frequency relates to these values thus: Output frequency (in MHz) = 6.5 x (integer + (fraction / 2^19)) For correct operation, the component (fraction / 2^19) must have a value between 1 and 2 (in other words, the "fraction" coefficient varies between 524288 and 1048576) while the value of "integer" is limited by the operating frequency range of the device (422.5 to 525MHz) so will lie between 64 and 79 So how do you calculate it by hand ? Take the frequency, divide it by 6.5 Take the whole number part remaining, subtract one from it, and that's "integer" Take everything right of the decimal point, add one and multiply by 524288, and that's "fraction" Example : 430MHz divide by 6.5 equals 66.15384615 so "integer" = 65 and fraction = (0.15384615 +1) x 524288 = 604948 and to confirm: 6.5 x (65+(604948/524288)) does indeed equal 430MHz (plus 3.9Hz) In interface terms, these coefficients are expressed as a 32 bit binary word (eight hexadecimal digits) where the most significant byte comprises the integer value, and the remaining three bytes (24 bits) make up "fraction" When programming the MTX2, keep in mind that the unit maintains (in RAM) the current values of all programmable values (current frequency, band of operation, RF power and frequency offset adjustments and the sequential table values) and that toggling the EN pin does NOT erase or corrupt them. These values are only loaded from eeprom at cold start power-up (but not when the EN pin is cycled) or when the unit is commanded to execute eeprom reads by certain serial functions (such as the "@PRG_00000000" command) There are no (or very few) "write a value to eeprom" commands. It is usually necessary to load the relevant current operating RAM value(s) and THEN issue a suitable command to write the RAM value to eeprom. The MTX2 eeprom stores a set of frequency coefficients for each parallel channel plus a fifth set for the sequential table start. It also stores power level, frequency offset, sequential table step size and sequential channel, and the band select constant Programming a value or coefficient over the serial bus over-writes the previous value and implements this change on the PLL immediately, but does not change the eeprom contents until a relevant "program eeprom" command is issued In general, the most recent stimulus received by the unit will decide the operating frequency and mode (although if sequential mode has been selected (serial channel not equal to zero) a change to the parallel port or a direct frequency program command will not initiate a frequency change).

Radiometrix Ltd MTX2 Data Sheet page 6 Operation Modes The MTX2 has three different modes of operation: 1. Parallel . By default the MTX2 operates on one of the four channels selected by the parallel input pins. At power up, or when a change of parallel input is detected, the current frequency coefficients are loaded from the eeprom stores corresponding to parallel channels 0-3. The parallel input consists of an inverted 2 bit binary number applied to P0/P1 (often from a 2 pole switch) 2. Sequential . If a (sequential) channel is programmed over the serial port, the unit sets it's operating frequency according to this channel number, the programmed table start frequency and the currently programmed table step size. If the channel is set to zero, the unit returns to default parallel operation. If the (sequential) channel is programmed into eeprom, the unit will default to this channel at power up The table can be considered to be a 255 entry table, starting at channel 1, with the frequency incrementing by the programmed step size for each increment in channel number (it can be seen that, if a 256 entry table starting with channel zero is desired then programming all the parallel channels to the ch0 frequency, and the sequential table start value to ch1 will achieve this) 3. Direct . Whenever a frequency coefficient is programmed into the unit, the frequency will change immediately to this new value regardless of other modes or operation. This is the simplest and most flexible means of controlling the unit. If a unit is set in sequential table mode (ie: channel value isn't zero), then direct programming cannot be used to over-ride the selected channel (executing an @PRG_iiffffff will just set up a set of frequency coefficients ready to be written to rom. It won't change the actual operating frequency) Serial interface commands MTX2 serial interface consists of an inverted RS232 datastream (9600 baud, 1+8+1, no parity) applied to the EN pin (the idle state of the interface will turn the transmitter on) Every command string starts with the phrase "@PRG_" The characters in a command string must not be separated by more than 5mS (so typing individual characters on a terminal keyboard will NOT work), but a pause of at least 10mS is required between commands (more following a BURN_ROM command. In this case a much longer idle period, of 50mS at least, is needed for eeprom programming) Frequency setting commands Commands Function @PRG_iiffffff <cr> sets the current (temporary) fre quency iiffffff is an 8 digit hexadecimal number (4 bytes): ii is the 1 byte "integer" coefficient ffffff is the 3 byte "fraction" coefficient Frequency (in MHz) = 6.5 x integer + 6.5 x (fraction/2^19) The component (fraction/2^19) must be in the range 1-2 @PRG_BURN_CH0 <cr> write current frequency into cha nnel 0 eeprom @PRG_BURN_CH1 <cr> write current frequency into cha nnel 1 eeprom @PRG_BURN_CH2 <cr> write current frequency into cha nnel 2 eeprom @PRG_BURN_CH3 <cr> write current frequency into cha nnel 3 eeprom (these functions do NOT program band/power/offset values)

Radiometrix Ltd MTX2 Data Sheet page 7 Sequential table operations Commands Function @PRG_0001zzzz <cr> program zzzz as the sequential table step size @PRG_BURN_CHC <cr> sets the current frequency coef ficients as the sequential table start frequency and programs this, and the step size, into eeprom @PRG_000000 cc <cr> set cc as sequential channel nu mber @PRG_0000FF cc <cr> set cc as above AND program it into eeprom @PRG_0000AA nn <cr> set a maximum channel limit (n n) for the table Setting channel to zero disables sequential table operation Serial port on/off commands Commands Function @PRG_POWER 00<cr> will turn the unit completely off (this command does NOT also zero the power setting variable) @PRG_POWER FF<cr> Unit is turned back on (or by cycling the EN pin) If the unit is in "software off" it will still decode valid commands (although an invalid string will be interpreted as an EN pin cycle, and the unit will turn on). The parallel port will also be read, although not acted upon until the unit is re-activated @PRG_00000000 <cr> will cause the unit to re-set it self to the values currently stored in eeprom (just like what happens at power-up). This also zeros the stored serial channel and does a parallel channel read Note : The characters in a command string must not be se parated by more than 5mS, but a pause of at least 10mS is required between commands (more following a BURN_ROM command a much longer idle period, of 50mS at least, is needed) The complete list of the MTX2 commands Commands Function @PRG_iiffffff <cr> sets the current operating frequency (in RAM) (ii is never zero, ffffff is in the range 080000 - 0FFFFF) @PRG_0001zzzz <cr> will program zzzz as the sequen tial table step size @PRG_00000000 <cr> eeprom values to RAM (cold star t-up) and channel = 0 @PRG_000000cc <cr> will set cc as sequential chann el number (in RAM) @PRG_0000FFcc <cr> will set cc as above AND progra m it into eeprom @PRG_0000AAnn <cr> will set (nn) as maximum channe l limit for the table and program it into eeprom @PRG_BURN_CH0 <cr> write current frequency into cha nnel 0 eeprom @PRG_BURN_CH1 <cr> write current frequency into cha nnel 1 eeprom @PRG_BURN_CH2 <cr> write current frequency into cha nnel 2 eeprom @PRG_BURN_CH3 <cr> write current frequency into cha nnel 3 eeprom @PRG_BURN_CHF <cr> write band, power and offset int o eeprom @PRG_BURN_CHC <cr> set table start to current freq uency AND write both this and the current step size values to eeprom @PRG_POWER pp <cr> sets power variable @PRG_TRIM+ aa <cr> set a positive frequency trim of fset @PRG_TRIM- aa <cr> set a negative frequency trim of fset @PRG_BAND# bb <cr> set band divider code (bb is O8, 0A,0B or 0D) @PRG_POWER 00 <cr> turn unit off @PRG_POWER FF <cr> turn unit back on

Radiometrix Ltd MTX2 Data Sheet page 8 Antenna requirements Three types of integral antenna are recommended and approved for use with the module: A) Whip This is a wire, rod ,PCB track or combination conn ected directly to RF pin of the module. Optimum total length is 16.4cm (1/4 wave @ 433MHz). Keep the open circuit (hot) end well away from metal components to prevent serious de-tu ning. Whips are ground plane sensitive and will benefit from internal 1/4 wave e arthed radial(s) if the product is small and plastic cased B) Helical Wire coil, connected directly to RF pin, open circu it at other end. This antenna is very efficient given it’s small size (20mm x 4mm dia.). The helical is a high Q antenna, trim the wire length or expand the coil for optimum results. The helical de-tunes badly with proximity to other conductive objects. C) Loop A loop of PCB track tuned by a fixed or variable c apacitor to ground at the 'hot' end and fed from RF pin at a point 20% from the ground end. Loo ps have high immunity to proximity de- tuning. Feature A B C whip helical loop Easy of design set-up * * Immunity proximity effects * * Range open ground to similar antenna 500m 200 100 The antenna choice and position directly controls t he system range. Keep it clear of other metal in th e system, particularly the 'hot' end. The best positi on by far, is sticking out the top of the product. This is often not desirable for practical/ergonomic reasons thus a compromise may need to be reached. If an internal antenna must be used, try to keep it away from othe r metal components, particularly large ones like transformers, batteries and PCB tracks/earth plane. The space around the antenna is as important as th e antenna itself. A. Helical antenna B. Loop antenna RF C1 C2 C4 C3 RF-GND C. Whip antenna 16.4cm RF 0.5 mm enameled copper wire close wound on 3.2 mm diameter former

433 MHz = 24 turns

Feed point 15% to 25% of total loop length track width = 1mm 4 to 10 cm inside area wire, rod, PCB-track or a combination of these three 433 MHz = 16.4 cm total from RF pin. RF Figure 7: Antenna types

Radiometrix Ltd MTX2 Data Sheet page 9

Ordering Information

Standard frequency setup for 4 channel MTX radios uses these default channels: Part no. Frequency MTX2-433-10 CH0: 434.650, CH1: 434.075, CH2: 434.50 0, CH3: 434.275MHz MTX2-458-10 CH0: 458.700, CH1: 458.525, CH2: 458.6 00, CH3: 458.750MHz MTX3-869-10-SAL CH0: 869.2125, CH1-3: 869.2375MHz (for Social Alarm use) Alternatively, the MTX2 can be supplied as a single frequency module with factory set channel (like the NTX2B or similar unit). In this case all channels are supplied programmed to the same frequency. Part no. Frequency MTX2-434.650-10 CH0 - 3: 434.650MHz MTX2-434.075-10 CH0 - 3: 434.075MHz MTX2-458.700-10 CH0 - 3: 458.700MHz Note : Also available on the other UHF band frequencies, including 869 or 915MHz (MTX3).

231 Kenton Lane

Harrow, Middlesex HA3 8RP ENGLAND Tel: +44 (0) 20 8909 9595 Fax: +44 (0) 20 8909 2233 sales@radiometrix.com www.radiometrix.com Copyright notice This product data sheet is the original work and copyrighted property of Radiometrix Ltd. Reproduction in whole or in part must give clear acknowledgement to the copyright owner. Limitation of liability The information furnished by Radiometrix Ltd is believed to be accurate and reliable. Radiometrix Ltd reserves the right to make changes or improvements in the design, specification or manufacture of its subassembly products without notice. Radiometrix Ltd does not assume any liability arising from the application or use of any product or circuit described herein, nor for any infringements of patents or other rights of third parties which may result from the use of its products. This data sheet neither states nor implies warranty of any kind, including fitness for any particular application. These radio devices may be subject to radio interference and may not function as intended if interference is present. We do NOT recommend their use for life critical applications. The Intrastat commodity code for all our modules is: 8542 6000. R&TTE Directive After 7 April 2001 the manufacturer can only place finished product on the market under the provisions of the R&TTE Directive. Equipment within the scope of the R&TTE Directive may demonstrate compliance to the essential requirements specified in Article 3 of the Directive, as appropriate to the particular equipment. Further details are available on The Office of Communications (Ofcom) web site: http://www.ofcom.org.uk/radiocomms/ifi/ Information Requests Ofcom Riverside House 2a Southwark Bridge Road London SE1 9HA Tel: +44 (0)845 456 3000 or 020 7981 3040 Fax: +44 (0)20 7783 4033 information.requests@ofcom.org.uk European Radiocommunications Office (ERO) Peblingehus Nansensgade 19 DK 1366 Copenhagen Tel. +45 33896300 Fax +45 33896330 ero@ero.dk www.ero.dk