MTWA26 SERIES 25W Multi-Plug Wall Mount for I.T. Equipment  Wide Input Voltage 90 to 264 VAC, 47 to 63Hz  Interchangeable AC plug(USA, UK, Europe, Australia)  Output Voltage Available From 5VDC Thru 48VDC  Single Output  Class II Insulation (Double Insulation)  Energy Star 2.0, CEC V, and RoHS compliance

1 Year Warranty Approvals:

Product Number Output Voltage Max. Output Current Total Regulation Maximum Output Power MTWA26-S02 5 ~ 6 VDC 3.30 ~ 2.75 A 5% 16.5W MTWA26-S03 6 ~ 8 VDC 3.33 ~ 2.50 A 5% 20W MTWA26-S04 8 ~ 11 VDC 2.75 ~ 2.00 A 5% 22W MTWA26-S05 11 ~ 13 VDC 2.27 ~ 1.92 A 5% 25W MTWA26-S06 13 ~ 16 VDC 1.92 ~ 1.56 A 5% 25W MTWA26-S07 16 ~ 21 VDC 1.56 ~ 1.19 A 5% 25W MTWA26-S08 21 ~ 27 VDC 1.19 ~ 0.92 A 3% 25W MTWA26-S09 27 ~ 33 VDC 0.92 ~ 0.75 A 3% 25W MTWA26-S10 33 ~ 40 VDC 0.75 ~ 0.62 A 3% 25W MTWA26-S11 40 ~ 48 VDC 0.62 ~ 0.52 A 2% 25W The total regulation on S02~S06 required to use AWG#16×2C/4FT output cable. The total regulation on S07~S11 required to use AWG#18×2C/4FT output cable. The regulation and efficiency will be changed by modified output cable.

Electrical Characteristics

Parameter Test Conditions Min. Typ. Max. Unit Input Voltage Operating Voltage 90 264 VAC Input Frequency 47 63 Hz Output Power Range Vin=100 to 240VAC 0 25 W Input Current (Low Line) Io=Full load, Vin=115VAC 0.4 A Input Current (High Line) Io=Full load, Vin=230VAC 0.25 A Low Line Inrush Current Io=Full load, 25° C, Cool start, Vin=115VAC 25 50 A High Line Inrush Current Io=Full load, 25° C, Cool start, Vin=230VAC 50 100 A Efficiency Io=Full Load, Vin=230VAC 77 82 85 % Line Regulation Io=Full Load 0.5 1 % Load Regulation Vin=230VAC 3 5 % Over Voltage Protection Nil % Over Current Protection Nil But, Output protected to short circuit conditions % Transient Response Io=Full Load to Half Load, Vin=100VAC 4 mS Hold-Up Time Io=Full Load, Vin=230VAC 8 mS Start Up Time Io=Full Load, Vin=100VAC 2 3 S Ripple & Noise (Peak to Peak) Full Load, Vin=90VAC 0.5 1 % Temperature Coefficient All output -0.04 0.04 %/° C No-load Power Consumption No load, Vin=240VAC 0.25 0.3 W

Parameter Test Conditions Min. Typ. Max. Unit Operating Temperature 0 40 70 °C Storage Temperature -40 85 °C Relative Humidity No-Condensing 5 95 % Operating Temperature at 25°C, Calculated per MIL-HDBK-217F 0.1M Hrs De-rate linearly from 100 % load at 40° C to 50 % load at 70° C Approvals and Compliance Parameter Test Conditions Min. Unit Dielectric Withstanding Voltage for Primary to secondary Primary to secondary 4242 VDC Isolation Resistance Test Voltage= 500VDC 50 MΩ EMI requirements for CISPR-22 Vin=220VAC B CLASS EMI requirements for FCC PART-15 Vin=110VAC B CLASS Mechanical and PIN out Note: 1. Dimensions are shown in mm. 2. Weight: 200g approx. 3. Optional output connector.