MTWA16 SERIES 15W Multi-Plug Wall Mount for I.T. Equipment Wide Input Voltage 90 to 264 VAC, 47 to 63Hz Interchangeable AC plug(USA, UK, Europe, Australia) Output Voltage Available From 5VDC Thru 48VDC Single Output Class II Insulation Energy Star 2.0, CEC V, and RoHS compliance
1 Year Warranty Approvals:
Product Number Output Voltage Max. Output Current Total Regulation Maximum Output Power MTWA16-S02 5 ~ 5.99 VDC 2.40 ~ 2.00 A 5% 12W MTWA16-S03 6.5 ~ 8 VDC 1.85 ~ 1.50 A 5% 12W MTWA16-S04 8 ~ 11 VDC 1.68 ~ 1.22 A 5% 13.5W MTWA16-S05 11 ~ 13 VDC 1.36 ~ 1.15 A 5% 15W MTWA16-S06 13 ~ 16 VDC 1.15 ~ 0.94 A 5% 15W MTWA16-S07 16 ~ 21 VDC 0.94 ~ 0.72 A 5% 15W MTWA16-S08 21 ~ 27 VDC 0.72 ~ 0.55 A 3% 15W MTWA16-S09 27 ~ 33 VDC 0.55 ~ 0.45 A 3% 15W MTWA16-S10 33 ~ 40 VDC 0.45 ~ 0.37 A 3% 15W MTWA16-S11 40 ~ 48 VDC 0.37 ~ 0.32 A 3% 15W Total Regulation is conditioned by below configuration (S02~S04: AWG18/4FT output cable) (S05~S09: AWG20/4FT output cable) (S10~S11: AWG22/4FT output cable)
Electrical Characteristics
Parameter Test Conditions Min. Typ. Max. Unit Input Voltage Universal Input Voltage 100 240 VAC Operating Voltage 90 264 VAC Input Frequency 47 63 Hz Output Power Range Vin=100 to 240VAC 0 15 W Input Current (Low Line) Io=Full load, Vin=115VAC 0.4 A Input Current (High Line) Io=Full load, Vin=230VAC 0.26 A Low Line Inrush Current Io=Full load, 25° C, Cool start, Vin=115VAC 25 50 A High Line Inrush Current Io=Full load, 25° C, Cool start, Vin=230VAC 50 100 A Efficiency Io=Full Load, Vin=230VAC 74.7 79 85 % Line Regulation Io=Full Load 0.5 1 % Load Regulation Vin=230VAC 3 10 % Over Voltage Protection Nil % Over Current Protection Nil But, Output protected to short circuit conditions % Transient Response Io=Full Load to Half Load, Vin=100VAC 4 mS Hold-Up Time Io=Full Load, Vin=230VAC 12 mS Start Up Time Io=Full Load, Vin=100VAC 2 3 S Ripple & Noise (Peak to Peak) Full Load, Vin=90VAC 0.5 1 % Safety Ground Leakage Current Io=Full Load, Vin=240VAC 0.25 mA Temperature Coefficient All output -0.04 0.04 %/° C No-load Power Consumption No load, Vin=240VAC 0.25 0.3 W
Parameter Test Conditions Min. Typ. Max. Unit Operating Temperature 0 40 70 °C Storage Temperature -40 85 °C Operating Humidity 0 95 % Storage Humidity 0 75 % Operating Temperature at 25°C, Calculated per MIL-HDBK-217F 0.1M Hrs De-rate linearly from 100 % load at 40° C to 50 % load at 70° C Approvals and Compliance Parameter Test Conditions Min. Unit Dielectric Withstanding Voltage for Primary to secondary Primary to secondary 4242 VDC Isolation Resistance Test Voltage= 500VDC 50 MΩ EMI requirements for CISPR-22 Vin=220VAC B CLASS EMI requirements for FCC PART-15 Vin=110VAC B CLASS Mechanical and PIN out Note: 1. Dimensions are shown in mm. 2. Weight: 165g approx. 3. Optional output connector.