380 - 13.8kV Reference MTU 20V4000 DS2500 (2500 kWe) for Standby Rating Technical Data // Emissions – EPA Tier 2 Certifi ed // Generator set is designed and manufactured in facilities certifi ed to standards ISO 9001:2008 and ISO 14001:2004 // Seismic Certification – Optional – IBC Certifi cation – OSHPD Pre-Approval // UL 2200 Listed – Optional // Performance Assurance Certification (PAC) - Generator Set Tested to ISO 8528-5 for Transient Response - Verifi ed product design, quality and performance integrity - All engine systems are prototype and factory tested // Power Rating - Accepts Rated Load in One Step Per NFPA 1 10 - Permissible average power output during 24 hours of operation is approved up to 75%. CERTIFICATIONS AND STANDARDS SYSTEM RATINGS Prime Voltage (L-L) 380V 480V* 600V 4160V 12470V 13200V 13800V Phase 3 3 3 3 3 3 3 Hz 60 60 60 60 60 60 60 kW 2250 2250 2250 2250 2250 2250 2250 kVA 2812 2812 2812 2812 2812 2812 2812 Amps 4273 3383 2706 390 130 123 1 17 skVA@30% Voltage Dip 3400 4675 5200 5750 4300 4750 5100 Generator Model 1020FDL1 104 1020RSL1 102 1020FDS1 122 1020FDM1 180 1020FDH1248 1020FDH1248 1020FDH1250 Temp Rise 105 °C/40 °C 105 °C/40 °C 105 °C/40 °C 105 °C/40 °C 105 °C/40 °C 105 °C/40 °C 105 °C/40 °C Connection 6 LEAD WYE 6 LEAD WYE 6 LEAD WYE 6 LEAD WYE 6 LEAD WYE 6 LEAD WYE 6 LEAD WYE * UL 2200 Off ered

2 /// / MTU 20V4000 DS2500 (2250 kWe) - Prime // Engine Air Cleaners Oil Pump Oil Drain Extension and S/O Valve Full Flow Oil Filters Closed Crankcase Ventilation Jacket Water Pump Inter Cooler Water Pump Thermostats Blower Fan and Fan Drive Radiator - Unit Mounted Electric Starting Motor - 24V Governor – Electronic Isochronous Base - Structural Steel SAE Flywheel and Bell Housing Charging Alternator - 24V Battery Box and Cables Flexible Fuel Connectors Flexible Exhaust Connection EPA Certifi ed Engine // Generator NEMA MG1, IEEE and ANSI standards compliance for temperature rise and motor starting Sustained short circuit current of up to 300% of the rated current for up to 10 seconds Self-Ventilated and Drip-Proof Superior Voltage Waveform Digital, Solid State, Volts-per-Hertz Regulator No Load to Full Load Regulation Brushless Alternator with Brushless Pilot Exciter

4 Pole, Rotating Field

105 °C Max. Prime Temperature Rise

2 Bearings, Sealed

125% Rotor Balancing 3-Phase Voltage Sensing ±0.25% Voltage Regulation 100% of Rated Load - One Step 5% Max. Total Harmonic Distortion // Digital Control Panel(s) Digital Metering Engine Parameters Generator Protection Functions Engine Protection CANBus ECU Communications Windows ®-Based Software Multilingual Capability Remote Communications to RDP-1 10 Remote Annunciator Programmable Input and Output Contacts UL Recognized, CSA Certifi ed, CE Approved Event Recording IP 54 Front Panel Rating with Integrated Gasket NFPA1 10 Compatible STANDARD EQUIPMENT* // MTU Onsite Energy is a single source supplier // Global Product Support // 2 Year Standard Warranty // 20V4000 Diesel Engine - 95.4 Liter Displacement - Common Rail Fuel Injection - 4-Cycle // Complete Range of Accessories // Generator - Brushless, Rotating Field Generator - 2/3 Pitch Windings - PMG (Permanent Magnet Generator) supply to regulator - 300% Short Circuit Capability // Digital Control Panel(s) - UL Recognized, CSA Certi fi ed, NFPA 1 10 - Complete System Metering - LCD Display // Cooling System - Integral Set-Mounted - Engine-Driven Fan STANDARD FEATURES* * Represents standard product only. Consult Factory/MTU Onsite Energy Distributor for additional confi gurations.

3 /// / MTU 20V4000 DS2500 (2250 kWe) - Prime // Engine Manufacturer MTU Model 20V4000G43 6 ECT Type 4-Cycle Arrangement 20-V Displacement: L (in 3) 95.4 (5,822) Bore: cm (in) 17 (6.69) Stroke: cm (in) 21 (8.27) Compression Ratio 16.4:1 Rated RPM 1,800 Engine Governor Electronic Isochronous (ADEC) Max. Power: kWm (bhp) 2,490 (3,338) Speed Regulation ±0.25% Air Cleaner Dry // Liquid Capacity (Lubrication) Total Oil System: L (gal) 390 (103) Engine Jacket Water Capacity: L (gal) 205 (54.2) After Cooler Water Capacity: L (gal) 30 (7.9) System Coolant Capacity: L (gal) 814 (215) // Electrical Electric Volts DC 24 Cold Cranking Amps Under -17.8 °C (0 °F) 4,200 // Fuel System Fuel Supply Connection Size -16 JIC 37° Female 1” NPT Adapter Provided Fuel Return Connection Size -16 JIC 37° Female 1” NPT Adapter Provided Max. Fuel Lift: m (ft) 1 (3) Recommended Fuel Diesel #2 Total Fuel Flow: L/hr (gal/hr) 1,620 (428) // Fuel Consumption At 100% of Power Rating: L/hr (gal/hr) 587 (155) At 75% of Power Rating: L/hr (gal/hr) 462 (122) At 50% of Power Rating: L/hr (gal/hr) 337 (89) // Cooling - Radiator System Ambient Capacity of Radiator: °C (°F) 54 (129) Max. Restriction of Cooling Air: Intake and Discharge Side of Rad.: kPa (in. H 20) 0.12 (0.5) Water Pump Capacity: L/min (gpm) 1,567 (414) After Cooler Pump Capacity: L/min (gpm) 567 (150) Heat Rejection to Coolant: kW (BTUM) 890 (50,613) Heat Rejection to After Cooler: kW (BTUM) 580 (32,984) Heat Radiated to Ambient: kW (BTUM) 203.6 (1 1,581) Fan Power: kW (hp) 87.5 (1 17.3) // Air Requirements Aspirating: *m3/min (SCFM) 228 (8,052) Air Flow Required for Rad. Cooled Unit: *m 3/min (SCFM) 2,895 (102,247) Remote Cooled Applications; Air Flow Required for Dissipation of Radiated Generator Set Heat for a Max. of 25 °F Rise: *m 3/min (SCFM) 744 (26,1 19) * Air density = 1.184 kg/m3 (0.0739 lbm/ft3) // Exhaust System Gas Temp. (Stack): °C (°F) 455 (851) Gas Volume at Stack Temp: m 3/min (CFM) 534 (18,858) Max. Allowable Back Pressure: kPa (in. H 20) 8.5 (34.1) APPLICATION DATA

4 /// / MTU 20V4000 DS2500 (2250 kWe) - Prime © MTU Onsite Energy. Subject to alteration due to technological advances. OE 23 713 (77 3E) 2015-09 EMISSIONS DATA NOx + NMHC CO PM 6.12 0.37 0.04 All units are in g/hp-hr and shown at 100% load (not comparable to EPA weighted cycle values). Emission levels of the engine may vary with ambient temperature, barometric pressure, humidity, fuel type and quality, installation parameters, measuring instrumentation, etc. The data was obtained in compliance with US EPA regulations. The weighted cycle value (not shown) from each engine is guaranteed to be within the US EPA Standards. RATING DEFINITIONS AND CONDITIONS // Prime power ratings apply to installations where utility power is unavailable or unreliable. At varying load, the number of generator set operating hours is unlimited. A 10% overload capacity is available for one hour in twelve. Ratings are in accordance with ISO 8528-1, ISO 3046-1, BS 5514, and AS 2789. Average load factor: ≤ 75%. // Deration Factor: Altitude: Consult your local MTU Onsite Energy Power Generation Distributor for altitude derations. Temperature: Consult your local MTU Onsite Energy Power Generation Distributor for temperature derations. WEIGHTS AND DIMENSIONS SOUND DATA Unit Type Prime Full Load Level 0: Open Power Unit dB(A) 97.5 Drawing above for illustration purposes only, based on standard open power 480 volt generator set. Lengths may vary with other voltages. Do not use for installation design. See website for unit specifi c template drawings. C/F = Consult Factory/MTU Onsite Energy Distributor N/A = Not Available Sound data is provided at 7 m (23 ft). Generator set tested in accordance with ISO 8528-10 and with infi nite exhaust. Weights and dimensions are based on open power units and are estimates only. Consult the factory for accurate weights and dimensions for your specifi c generator set. MTU Onsite Energy A Rolls-Royce Power Systems Brand www.mtuonsiteenergy.com System Dimensions (L x W x H) Weight (dry/less tank) Open Power Unit (OPU) 7,640 x 2,915 x 3,310 mm (300.88 x 1 14.75 x 130.5 in) 26,941 kg (59,394 lb)