200-JS6DT3 MTU | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

Diesel engine-generator set 200-Js6Dt3 200 ekW / 60 Hz / Standby 208 - 600V A tognum group BrAnd // EPA Tier 3 Certified // Engine-Generator Set Tested to ISO 8528-5 for transient response // UL2200, CSA Listing Offered // Accepts Rated Load in One Step Per NFPA 1 10, Level 1 // All engine-generator sets are prototype and factory tested // MTU Onsite Energy is a single source supplier // Global Product Support // 2 Year Standard Warranty // 6068HF485 Diesel Engine - 6.8 Liter Displacement - 4-Cycle // Complete Range of Accessories // Permanent Magnet Generator (PMG) - Optional - Brushless, Rotating Field - 300% Short Circuit Capability - 2/3 Pitch Windings // Digital Control Panel(s) - UL Recognized, , NFPA 1 10 - Complete System Metering - LCD Display // Cooling System - Integral Set-Mounted - Engine Driven Fan FACTS system ratings Standby Phase 1 1 3 3 3 3 Hz 60 60 60 60 60 60 kW 200 200 200 200 200 200 kVA 200 200 250 250 250 250 AMPS 833 833 694 601 301 241 skVA@30% Voltage Dip 520 364 370 491 491 510 Generator Model 432CSL6212 432CSL6228 431CSL6206 431CSL6206 431CSL6206 431PSL6243 Temp Rise 130°C/27°C 130°C/27°C 130°C/27°C 130°C/27°C 130°C/27°C 125°C/40°C Connection 12 LEAD ZIG-ZAG 4 LEAD 1 2 LEAD LOW WYE 1 2 LEAD HI DELTA 12 LEAD HI WYE 4 LEAD WYE ** UL2200 Offered

// Engine Air Cleaner Oil Pump Full Flow Oil Filter Jacket Water Pump Closed Crankcase Vent Thermostats Exhaust Manifold – Dry Blower Fan & Fan Drive Radiator - Unit Mounted Electric Starting Motor - 12V Governor – Electric Isochronous Base - Formed Steel SAE Flywheel & Bell Housing Charging Alternator - 12V Battery Box & Cables Flexible Fuel Connectors Flexible Exhaust Connection EPA Certified Engine // generator NEMA MG1, IEEE and ANSI standards compliance for temperature rise and motor starting Sustained short circuit current of up to 300% of the rated current for up to 10 seconds Self-Ventilated and Drip-Proof Superior Voltage Waveform Digital, Solid State, Volts-per-Hertz Regulator No Load to Full Load Regulation Brushless Alternator with Brushless Pilot Exciter

4 Pole, Rotating Field

130°C Standby Temperature Rise

1 Bearing, Sealed

125% Rotor Balancing 3-Phase Voltage Sensing ±1% Voltage Regulation 100% of Rated Load - One Step 3% Maximum Harmonic Content // digital Control panel(s) Digital Metering Engine Parameters Generator Protection Functions Engine Protection SAE J1939 Engine ECU Communications Windows-Based Software Multilingual Capability Remote Communications to our RDP-110 Remote Annunciator

16 Programmable Contact Inputs

7 Contact Outputs

UL Recognized, , CE Approved Event Recording IP 54 Front Panel Rating with Integrated Gasket NFPA1 10 Level Compatible // Additional Features Oil Drain Extension & S/O Valve Flexible Fuel Connector Battery Cables Vibration Isolation Pads Jacket Water Heater: -20º F Mainline Circuit Breaker UL2200 Listed Steel Sub-Base Radiator Duct Flange (OPU) Lube Oil & Antifreeze Operator’s and Owner’s Manual

2 Year/3000 Hour Warranty

Factory Tested at 0.8 PF (3 PH) // optional Features Battery Charger: 6 Amp or 10 Amp Battery: 12 Volt w/ Rack Circuit Breaker: Standard or 100% Muffler (OPU only) Sub-Base Fuel Tank w/ Electrical Stub-Up Area Weatherproof Enclosure Sound Attenuation - 1 1/2” Foam - Sound Scoops Remote Annunciator Isochronous Governor stanDarD eQUiPment

// Engine Manufacturer John Deere Model 6068HF485 Type 4-Cycle Arrangement 6-Inline Displacement: Cu In (lit) 415 (6.8) Bore: in (cm) 4.2 (10.6) Stroke: in (cm) 5 (12.7) Compression Ratio 17:1 Rated RPM 1,800 Engine Governor JDEC Max Power: Standby: bhp (kWm) 315 (235) Regulation ±1% Frequency 60 Hz Air Cleaner Dry // Liquid Capacity (Lubrication) Total Oil System: gal (lit) 8.5 (32.2) Engine Jacket Water Capacity: gal (lit) 3.3 (11.9) System Coolant Capacity: gal (lit) 7.75 (29.3) // Electrical Electric Volts DC 12 Cold Cranking Amps Under 0°F (-17.8°C) 800 // Fuel System Fuel Supply Connection Size 3/8” NPT Fuel Return Connection Size 3/8” NPT Maximum Fuel Lift: ft (m) 6.7 (2) Recommended Fuel Diesel #2 Total Fuel Flow: gal/hr (lit/hr) 24.5 (93) // Fuel Consumption At 100% of Power Rating: gal/hr (lit/hr) 15.5 (58.6) At 75% of Power Rating: gal/hr( lit/hr) 11.3 (42.9) At 50% of Power Rating: gal/hr (lit/hr) 7.9 (30) // Cooling - radiator System Ambient Capacity of Radiator: °F (°C) 122 (50) Max. Restriction of Cooling Air, Intake, and Discharge Side of Rad.: in. H20 (kPa) 0.5 (0.12) Water Pump Capacity: gpm (lit/min) 70 (265) Heat Rejection to Coolant: BTUM (kW) 5,404 (94.9) Heat Radiated to Air to Air: BTUM (kW) 3,264 (57) Heat Radiated to Ambient: BTUM (kW) 1,530 (27) // Air requirements Aspirating: *SCFM (m3/min) 619 (17.5) Air Flow Required for Rad. Cooled Unit: *SCFM (m3/min) 17,712 (502) Air Flow Required for Heat Exchanger/Remote Rad. based on 25°F Rise: *SCFM (m3/min) 3,451 (98) * Air density = 0.0739 lbm/ft3 (1.184 kg/m3) // Exhaust System Gas Temp. (Stack): °F (°C) 905 (485) Gas Volume at Stack Temp: CFM (m3/min) 1,514 (42.9) Maximum Allowable Back Pressure: in. H20 (kPa) 40 (10) aPPlication Data

© MTU Onsite Energy. Subject to alteration due to technological advances. 2009-05 emissions Data nox + nmHC Co pm 2.76 0.43 0.059 All units are in g/hp-hr and are EpA d2 cycle values. Emission levels of the engine may vary as a function of ambi- ent temperature, barometric pressure, humidity, fuel type and quality, installation parameters, measuring instrumentation, etc. The data provided are laboratory results from one engine representing this rating. The data was obtained under cont- rolled environmental conditions with calibrated instrumentation traceable to the United States National Bureau of Standards and in compliance with US EPA regulations found within 40 CFR Part 89. The weighted cycle value from each engine is guaran- teed to be below the US EPA Standards at the US EPA defined conditions. RATING DEFINITIONS AND CONDITIONS // Ambient capability factor at 984 ft (300 m). Consult your local MTU Onsite Energy Power Generation Distributor for other altitudes. // Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. No overload capa- bility for this rating. Ratings are in accordance with ISO-3046/1, BS 5514, AS 2789, and DIN 6271. // Deration Factor: Altitude: 0.5% per 1,000 ft (305 m) above 5,000 ft (1,524 m) and 4% per 1,000 ft (305 m) above 10,000 ft (3,048 m). temperature: 0.5% per 10°F (5.5°C) above 77°F (25°C). WEIGHTS AND DIMENSIONS soUnD Data unit type Standby Full Load Standby no Load OPU w/Critical Grade Muffler (dBA) 93 85 Sound Attenuated Enclosure (dBA) 85 77 System dimensions (L x W x H) Height w/tank 24hr. Weight (less tank) OPU 110 x 52 x 65.6 in (2790 x 1320 x 1,670 mm) 97.6 in (2,480 mm) 4,007 lb (1,818 kg) EPU 110 x 52 x 77.9 in (2790 x 1320 x 1,980 mm) 109.9 in (2,790 mm) 4,808 lb (2,181 kg) Drawing above for illustration purposes only, based on standard open power 480 volt generator. Lengths may vary with other voltages. Do not use for installation design. Materials and specifications subject to change without notice. // tognum group Companies: Europe / middle East / Africa / Latin America / MTU Onsite Energy / 88040 Friedrichshafen / Germany / Phone + 49 7541 90 7060 / Fax +49 7541 90 7084 / powergenregion1@mtu-online.com // Asia / Australia / Pacific / MTU Onsite Energy / 1, Benoi Place / Singapore 629923 / Republic of Singapore / Phone + 65 6861 5922 / Fax + 65 6861 3615 / powergenregion2@mtu-online.com // uSA / Canada / mexico / MTU Onsite Energy / 100 Power Drive / Mankato, Minnesota 56001 / USA / Phone + 1 507 625 7973 / Fax + 1 507 625 2968 / powergenregion3@mtu-online.com // Worldwide for Hotmodule / MTU Onsite Energy / 81663 Munich / Germany / Phone + 49 89 203042 800 / Fax +49 89 203042 900 / info@mtu-online.com // www.mtu-online.com Weights and dimensions are based on open power units and are estimates only. Consult the factory for accurate weights and dimensions for your specific generator set. Measurements for sound data are taken at 23 ft (7 m).