MSR6R ALLEN-BRADLEY | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
Features
- Category 3 per EN 954-1
- Stop category 0
- Switch selectable input
- 3 N.O. safety outputs
- 1 N.C. auxiliary output
- Switch selectable reset
- 45mm wide housing Application Details Contactor monitoring circuit Contactor switching circuit Supply inclusive of switching circuit Contactor Monitored by Minotaur MSR6R/T Specifications ➊ See Output Ratings on page 1-29 for details. Consult factory for ratings not shown. Standards EN 954-1, ISO13849-1, IEC/EN 60204-1, IEC 60947-5-1, ANSI B11.19, AS4024.1 Category Cat. 3 per EN 954-1 (ISO 13849-1) Approvals C-Tick, CE marked for all applicable directives, cULus & TUV Power Supply 24V AC/DC, 110V or 230V AC 50/ 60Hz Power Consumption <4VA Safety Inputs 2 N.C. Input Simultaneity 0.5 seconds Maximum Input Resistance 500 Ω Reset Monitored Man. or Auto./Man. Outputs 3 N.O. Safety; 1 N.C. Auxiliary ➊ Output Utilization per IEC 60947-5-1 (Inductive) B300 AC-15; 4A/250V AC, 4A/120V AC P300 DC-13; 3A/24V DC Thermal Current (non switching) 4A Fuses Input (internal, replace.) Output (external) 500mA time lag 5A quick acting Min. Switched Current/Voltage 10mA/10V Maximum Dropout Time 50ms Indication LEDs Red = Power On; Green = K1 Closed; Green = K2 Closed; Amber = Single Channel Mode Impulse Withstand Voltage 2500V Installation Group C in accordance with VDE 0110 Pollution Degree 3 Operating T emperature -10°C to +55°C (+14°F to +131°F) Humidity 90% RH Enclosure Protection IP40, (NEMA 1), DIN 0470 T erminal Protection IP20, DIN 0470 Conductor Size 1 x 2.5mm 2 (14AWG) stranded, 1 x 4mm2 (12AWG) solid T orque Settings—term. screws 1N⋅m (8.85lb⋅in) Case Material Red Polycarbonate Mounting 35mm DIN rail Weight 510g (1.12lbs) Electrical Life 220V AC/4A/880VA cosϕ=0.35 220V AC/1.7A/375VA cosϕ=0.6 30V DC/2A/60W 10V DC/0.01A/0.1W 100,000 operations 500,000 operations 1,000,000 operations 2,000,000 operations Mechanical Life 2,000,000 operations Vibration 0.75mm (0.30in) peak, 10-55Hz Shock 30g, 11ms half sine Use a slotted screwdriver to pop open cover to reveal switches & fuse. D & S Input Selector Switch D = Dual channel input. S = Single channel input. R&T Reset Selector Switch R = Monitored manual reset facility with system check for high integrity utilizing a momentary push button. The push and release feature means the button can not be held in. T = Automatic system check. Input Switch Replacement Fuse Reset Switch D S R T
Dimensions—mm (inches) Block Diagram Typical Wiring Diagrams Inputs Safety Outputs Auxiliary Out puts Power Supply Catalogue Number 24V AC/DC 440R-C23017 110V AC 440R-C23018 230V AC 440R-C23019 Description Page Number Catalogue Number 500mA Fuse 14-6 440R-A31562 A2 X2 T R X1 S23 S13 S24 S14 14 24 13 3323 41 34 42 K4K2 K1 K5 K1 K1 K2K6 K4 K5 K6 D S 24VDC 73 (2.87) 35mm DIN Rail Mounting S23 X1S24 S14S13 X2A2 14 24 13 33 23 41 34 42 K1 K2 M D R S23 X1S24 S14S13 X2A2 14 24 13 33 23 41 34 42 K1 K2 M D T S23 X1S24 S14S13 X2A2 14 24 13 33 23 41 L2 L3 34 42 M S R S23 X1S24 S14S13 X2A2 14 24 13 33 23 41 L2 L3 34 42 M S T Single-Channel Safety Gate, Monitored Manual Reset, Single-Channel Output, Monitored Output 24V DC MSR6R/T open Ground Aux Single-Channel Safety Gate, Automatic Reset, Single-Channel Output, No Monitored Output 24V DC MSR6R/T Ground Aux closed Reset N open closed Dual-Channel Safety Gate, Monitored Manual Reset, Dual-Channel Output, Monitored Output Dual-Channel Safety Gate, Automatic Reset, Dual-Channel Output, Monitored Output open closed Aux Reset N open closed Aux MSR6R/T MSR6R/T