Features

  • Category 4 per EN 954-1
  • Stop category 0
  • Single channel input
  • 3 N.O. safety outputs
  • 1 N.C. auxiliary output
  • 22.5mm wide housing
  • Optional 110/230V AC input module

Applications

--+ Contactor monitoring circuit Contactor switching circuit Supply inclusive of switching circuit Contactor Monitored by Minotaur Switching circuit Supply MSR5T Specifications ➊ See Output Ratings on page 1-29 for details. Consult factory for ratings not shown. Standards EN 954-1, ISO13849-1, IEC/EN 60204-1, IEC 60947-5-1, ANSI B11.19, AS4024.1 Category Cat. 4 per EN 954-1 Approvals C-Tick, CE marked for all applicable directives, cULus and TUV Power Supply 24V AC/DC±15% 50/60Hz Power Consumption <4VA Safety Inputs 1 N.C. Maximum Input Resistance 200 Ω Reset Automatic/Manual Outputs 3 N.O. Safety; 1 N.C. Auxiliary ➊ Output Utilization per IEC 60947-5-1 (Inductive) B300 AC-15 4A/250V AC, 4A/120V AC P300 DC-13 3A/24V DC Thermal Current (non switching) 4A Fuses, output 5A quick acting Min. Switched Current/Voltage 10mA/10V Maximum Dropout Time 90ms Indication LEDs Green = Output Impulse Withstand Voltage 2500V Installation Group C in accordance with VDE 0110 Pollution Degree 3 Operating T emperature -10°C to +55°C (+14°F to +131°F) Humidity 90% RH Enclosure Protection IP40, (NEMA 1), DIN 0470 T erminal Protection IP20, DIN 0470 Conductor Size 1 x 2.5mm 2 (14AWG) stranded, 1 x 4mm2 (12AWG) solid T orque Settings—terminal screws 1N⋅m (8.85lb⋅in) Case Material Red Polycarbonate Mounting 35mm DIN rail Weight 210g (0.46lbs) Electrical Life 220V AC/4A/880VA cosϕ=0.35 220V AC/1.7A/375VA cosϕ = 0.6 30V DC/2A/60W 10V DC/0.01A/0.1W 100,000 operations 500,000 operations 1,000,000 operations 2,000,000 operations Mechanical Life 2,000,000 operations Vibration 0.75mm (0.30in) peak, 10-55Hz Shock 30g, 11ms half sine The MSR5T monitors itself for any internal fault Contactors: Provides contactor monitoring if two or more contactors are usedThe safety function is ensured by the Minotaur

Dimensions—mm (inches) Block Diagram Typical Wiring Diagrams Inputs Safety Outputs Auxiliary Out puts Power Supply Catalogue Number Description Page Number Catalogue Number 110/230V AC Power Supply Unit 4-8 440R-A32003 500mA Fuse 14-6 440R-A31562 A2 X2X1A1 14 24 13 3323 41 34 42 K1 K2 K2K2K1 24VDC 99 (3.9) 35mm DIN Rail Mounting 75 (2.95) 82 (3.23) 22.5 (0.89) X2A2 14 24 13 3323 41 L1 L2 34 42 K1 K2 M L1 L2 M L1 L2 M X2A2 14 24 13 3323 41 34 42 K1 K2 M Single-Channel Gate Interlock, Automatic Reset, Single-Channel Output, No Monitored Output 24V DC MSR5T open Ground Aux Dual-Channel E-Stop, Manual Reset, Dual-Channel Output, Monitored Output 24V DC MSR5T E-Stop Ground Aux Reset closed