MSR33RT ALLEN-BRADLEY | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

Features

  • Category 4 per EN954-1
  • Stop Category 0
  • 2 Solid State N.O. Safety Outputs
  • 1 Solid State N.O. Auxiliary Output
  • 1 N.O. & 1 N.C. Input Housing with removable terminals shown. Specifications ➊ See Output Ratings on page 1-29 for details. Consult factory for ratings not shown. Wiring Terminations Standards EN954-1, ISO13849-1, IEC/ EN60204-1, ANSI B11.19, AS4024.1 Safety Category Cat. 4 per EN954-1 (ISO13849-1) Approvals CE for all applicable directives, C- Tick, cULus, TUV Power Supply 24V DC SELV (max with no load) electrically separate supply source Power Consumption 3W Safety Inputs 1 N.C. & 1 N.O. Max. Allowable Input Resistance 200 ohms Outputs 2 N. O. Safety, Solid State 1 N.O. Aux, Solid State Output Rating Safety Auxiliary 2A @ 24VDC 50mA @ 24VDC Short-Circuit Protection Inputs and outputs (safety and aux) Power On Delay 3s Response Time 15ms Recovery Time 20ms Indication LEDs Green = Power (Pwr) Green = CH1 Energized Green = CH2 Energized Pwr LED 3s Blink Diagnostics Constant

2 Blinks

4 Blinks

Config. change during operation Solid state output switch fault Internal Fault Operating T emperature -5°C to +55°C (+14° to +131°F) Humidity 90% RH Enclosure Protection IP40 (NEMA 1), DIN VDE 0470-1 T erminal Protection IP20 Pollution Degree 2 Conductor Size 0.2 – 2,5mm 2 (24 – 14AWG) Mounting In panel enclosure (IP54) 35mm DIN rail Weight 130g (0.287 lbs) Vibration 10-55Hz, 0.35mm Shock 10g, 16ms, 100 shocks S11 & S21 Pulse checking dynamic output S12 & S22 Input contacts A1 – S34 Reset switch S11 – S34 Automatic reset, start-up test disabled S21 – S34 Automatic reset, start-up test enabled A1 – Y2 Monitoring circuit

Dimensions—mm (inches) Block Diagram Typical Wiring Diagrams Inputs Safety Outputs Auxiliary Outputs T erminals Catalogue Number Solid state 1 N.O. Solid state Fixed 440R-F23199 Removable 440R-F23200 Y2S21 Y41 Y32 S12 S22 Y32 S34S11 114.5 (4.5) MSR33RT/RTP 14 2 4 Y2S21 Y41 S12 S22 Y32 S34S11 K1 K2 M L1 L2 L3 14 2 4 Y2S21 Y41 S12 S22 Y32 S34S11 K1 K2 M L1 L2 L3 14 2 4 Y2S21 Y41 S12 S22 Y32 S34S11 K1 K2 M L1 L2 L3 14 2 4 Y2S21 Y41 S12 S22 Y32 S34S11 K1 K2 M L1 L2 L3 +24V MSR33RT/RTP Reset Ground Aux to PLC or Indicator Sipha Sensor Inputs, Dual Channel Outputs, Monitored Manual Reset, Output Monitoring Start-up Test Disabled Sipha Sensor Inputs, Dual Channel Outputs, Automatic Reset, Output Monitoring Start-up Test Enabled +24V MSR33RT/RTP Ground Aux to PLC or Indicator Dual Channel Inputs, Dual Channel Outputs, Monitored Manual Reset, Output Monitoring Start-up Test Disabled Dual Independent Inputs, Dual Channel Outputs, Automatic Reset, No Output Monitoring Start-up Test Disabled +24V MSR33RT/RTP Reset Ground Aux to PLC or Indicator +24V MSR33RT/RTP Ground Aux to PLC or Indicator