MSR15D ALLEN-BRADLEY | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

Features

  • Safety category 3
  • Stop category 0 and 1
  • 2 N.C. dual channel input
  • 2 N.O. safety outputs
  • 1 N.O. safety delayed output
  • 1 N.C. auxiliary output
  • Automatic/manual reset
  • 45mm wide housing The safety function is ensured by the Minotaur Switch circuit MSR15D monitors for any single fault that may cause a danger. MSR15D monitors itself for any internal fault. Contactors: Provides contactor monitoring if two or more contactors are used in series. Specifications ➊ See Output Ratings on page 1-29 for details. Consult factory for ratings not shown. Standards EN 954-1, ISO13849-1, IEC/EN 60204-1, IEC 60947-5-1, ANSI B11.19, AS4024.1 Category Cat. 3 per EN 954-1 (ISO 13849-1) Approvals C-Tick, CE marked for all applicable directives, cULus & TÜV Power Supply 24V AC/DC Power Consumption <4VA Safety Inputs 2 N.C. Input Simultaneity 0.5s Maximum Input Resistance 500 Ω Reset Automatic/Manual Outputs 2 N.O. Safety; 1 N.C. Auxiliary ➊ Output Utilization per IEC 60947-5-1 (Inductive) B300, AC-15 4A/250V AC, 4A/125V AC P300, DC-13; 2A/24V DC Thermal Current (non switching) 4A Fuses Input (internal, replace.) Output (external) 500mA time lag 5A quick acting Min. Switched Current/Voltage 10mA/10V Maximum Dropout Time 90ms Indication LEDs Red = Power On Green = K1 Closed Green = K2 Closed Impulse Withstand Voltage 2500V Installation Group C in accordance with VDE 0110 Pollution Degree 3 Operating T emperature -10°C to +55°C (+14°F to +131°F) Humidity 90% RH Enclosure Protection IP40, (NEMA 1), DIN 0470 T erminal Protection IP20, DIN 0470 Conductor Size 1 x 2.5mm 2 (14AWG) stranded, 1 x 4mm2 (12AWG) solid T orque Settings—terminal screws 1N⋅m (8.85lb⋅in) Case Material Red Polycarbonate Mounting 35mm DIN rail Weight 230g (.51lbs) Electrical Life 220V AC/4A/880VA cosϕ=0.35 220V AC/1.7A/375VA cosϕ=0.6 30V DC/2A/60W 10V DC/0.01A/0.1W 100,000 operations 500,000 operations 1,000,000 operations 2,000,000 operations Mechanical Life 2,000,000 operations Vibration 0.75mm (0.30in) peak, 10-55Hz Shock 30g, 11ms half sine

Monitoring Safety Relays with Delayed Outputs Minotaur MSR15D Product Selection Accessories Dimensions—mm (inches) Block Diagram Typical Wiring Diagrams Application Details Inputs Safety Outputs Auxiliary Outputs Pow er Supply Delay Timing Catalogue Number 2 N.C. 2 N.O. Instantaneous 1 N.O. Delayed 1 N.C. 24V AC/DC 0.1 to 10 seconds 440R-M23048 1 to 35 seconds 440R-M23057 Description Page Number Catalogue Number 500mA Fuse 14-6 440R-A31562 A2 X2 X1 S13 S14A1 D14 14 D13 2313 31 24 32 K1 K5 24VDC S23S24 Timer VR1 118 (4.65) 35mm DIN Rail Mounting 73 (2.87) 45.5 (1.79) A2 X2 X1S13 S14 D1414 D132313 31 24 32 S23 S24 L1 L2 L3 M K212 22 34 11 21 33 54A1 Guard Closed & Unlocked TLS2-GD2 Stop MSR15D Aux Ground Reset Dual Channel Guardlocking Safety Gate, Delayed Gate Release, Manual Reset, Dual Channel Output, Monitored Output 24V DC Adjustment of delay time for output D13-D14 500 mAT MinimumMaximum Fuse replacement