Features
Parameter Symbol Maximum Rating Unit Peak Forward Current(1/10 Duty Cycle@1KHz ) IFP 100 mA Continuous Forward Current IF 30 mA Reverse Voltage VR 5 V Operating Temperature Range Topr -20oC to +80oC Storage Temperature Range Tstg -30oC to +100oC 08/07/2001 Unity Opto Technology Co., Ltd. @ TA=25oC Notes : 1. All dimensions are in millimeters. 2. Tolerance is ± 0.10 mm unless otherwise noted. Unit: mm Common Anode
Optical-Electrical Characteristics Blue Parameter Test Conditions Symbol Min . Typ . Max . Unit . Luminous Intensity IF=20mA IV 15 40 - mcd Forward Voltage IF=20mA VF - 3.7 4.2 V Reverse Current IR - - 100 µA Peak/Dominant Wavelength IF=20mA λd - 470 - nm Spectral Linewidth IF=20mA Δλ - 26 - nm Viewing Angle IF=20mA 2θ1/2 - 120 - deg. Green Parameter Test Conditions Symbol Min . Typ . Max . Unit . Luminous Intensity IF=20mA IV 70 150 - mcd Forward Voltage IF=20mA VF - 3.7 4.2 V Reverse Current IR - - 100 µA Peak/Dominant Wavelength IF=20mA λd - 525 - nm Spectral Linewidth IF=20mA Δλ - 35 - nm Viewing Angle IF=20mA 2θ1/2 - 120 - deg. Orange Parameter Test Conditions Symbol Min . Typ . Max . Unit . Luminous Intensity IF=20mA IV 25 50 - mcd Forward Voltage IF=20mA VF - 2.0 2.6 V Reverse Current IR - - 100 µA Peak/Dominant Wavelength IF=20mA λd - 625 - nm Spectral Linewidth IF=20mA Δλ - 20 - nm Viewing Angle IF=20mA 2θ1/2 - 120 - deg. Typical Optical-Electrical Characteristic Curves VR=5V VR=5V VR=5V 08/07/2001 0.5 400 480 550 630 Unity Opto Technology Co., Ltd. Wavelength (nm) FIG.1 RELATIVE INTENSITY LUMINOUS VS. WAVELENGTH Relative Luminous Intensity @ TA=25oC @ TA=25oC @ TA=25oC B G R
Typical Optical-Electrical Characteristic Curves 08/07/2001 0 25 50 75 100 0.1 0 20 30 50 70 90 Unity Opto Technology Co., Ltd. Ambient Temperature (oC) FIG.5-3 RELATIVE LUMINOUS INTENSITY VS. AMBIENT TEMPERATURE Relative Luminous Intensity Relative Luminous Intensity Forward Current IF (mA) Forward Current IF (mA) FIG.4 RELATIVE LUMINOUS INTENSITY VS. FORWARD CURRENT Relative Luminous Intensity Normalized at IF=20mA 0.2 0.4 0.6 0.8 1.2 1.4 1.6 0 5 10 15 20 25 Ambient Temperature (oC) FIG.3 FORWARD CURRENT VS. AMBIENT TEMPERATURE Ambient Temperature (oC) FIG.5-2 RELATIVE LUMINOUS INTENSITY VS. AMBIENT TEMPERATURE Relative Luminous Intensity0.1 0 25 50 75 1.0 0.9 0.8 0o 10o 20o 90° 70° 30° 40° 60° 50° 80° FIG.6 RADIATION DIAGRAM B/G R 0.0 2.0 4.0 6.0 R Forward Current IF(mA) Forward Voltage (V) FIG.2 FORWARD CURRENT VS. FORWARD VOLTAGE B.G