8905 BURKERT | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 12

Technical content

Visit product website  DATA SHEET Type MS01  pH Sensor Cube Type MS02  Chlorine (Cl2) or chlorine dioxide (ClO2) Sensor Cube Type MS03  Conductivity Sensor Cube Type MS04  Redox Sensor Cube Type MS05  Turbidity Sensor Cube Type 8920  Bürkert Communicator Type ME2X  System Control Unit Type MZ20  Cleaning System Standard | EU | en | 202304 | 09 Online Analysis System

  • For analysis applications for drinking water and fresh water in in - dustrial processes Modular sensor and electronic system: - up to 6 measurements in one housing - up to 30 analysis sensor cubes in one Bürkert system bus (büS) Prepared for fielbus connectivity and remote access MEMS technologies allows minimal footprint and minimum sample water demand Type 8905 Online Analysis System is a compact and modular system for monitoring all important water parameters on one platform. It is a multichan- nel measuring system for the Bürkert sensor cubes as well as other electronic modules from the EDIP platform. The efficient device integration platform (EDIP) allows a high flexibility by using modularity in the hardware as well as in the software of the system. The following parameters can be integrated into an online analysis system: pH, chlorine/chlorine dioxide, conductivity, ORP, turbidity, temperature. A modular system concept allows the measuring system to be assembled according to customer requirements and enables simple installation and start- up, as well as operation and maintenance. For maintenance, sensors can be removed without tools, while the remaining sensors continue to measure. The sensors are operated via an integrated 7" touch display or Bürkert Communicator. In addition to the display and storage of analysis parameters, other functions are possible, for example: program- ming of simple control algorithms using f(x), interventions in the process via analog and digital inputs and outputs, performing sensor calibrations. Type 8905 is available as a compact system in one housing, as well as a customised system. For a system configuration please contact your Bürkert sales center. Product variants described in the data sheet may differ from the product presentation and description. Type descriptionCan be combined with Type 8905 © Christian Bürkert GmbH & Co. KG, Subject to alteration

2 | 12Visit product website  Table of contents 1. General technical data 3 Materials 2.2. Material specifications 3. Dimensions 6 Product design and assembly Housing for the electric modules Housing for the sensor cubes Mechanical interfaces of the sensor cubes 5. Product accessories 9

Ordering information

6.2. 6.3. Bürkert product filter 6.4. Ordering chart 6.5. Ordering chart accessories

3 | 12Visit product website  1. General technical data Product properties Material Please make sure the device materials are compatible with the fluid you are using. Detailed information can be found in chapter “2.1. Chemical Resistance Chart – Bürkert resistApp” on page Detailed information on the materials can be found in chapter “2.2. Material specifications” on page 5 Non wetted parts Cover • Of the electronic module housing: PC (glass fibre reinforced, UV stabilized, UL94 V0, anthracite grey), PC (black, UV stabilized, UL94 V0) and glass Of the sensor cube housing: PC (glass fibre reinforced, UV stabilized, UL94 V0, anthra cite grey) and PC (transparent) Housing PC (black, UV stabilized, UL94 V0) Quarter-turn stud Stainless steel Cable entry plate Elastomer Wall-mounting bracket Stainless steel Self-adhesive spacer Polyurethane Wetted parts Fluid connection Biopolymer (EPDM seals) Display • 780 460 pixels resolution Capacitive 7" Touchscreen, backlit Dimensions Detailed information can be found in chapter “3. Dimensions” on page 6 Weight • Approx. 8 kg (if equipped with 1 100…240 V AC power supply module + 1 x HMIU module + 5 sensor cubes) Up to 12 kg (if totally equipped) Data logger Integrated Micro SD, 2 GB; adjustable logging interval; external reading via USB or LAN port Electrical data Operating voltage (“SUPPLY”) • 100…240 V AC 50/60 Hz – current consumption at 100 V AC: 0.8 A – current consumption at 240 V AC: 0.3 A – tolerance: ± – integrated protective fuse: a slow blow 2 A fuse. The fuse cannot be replaced and is integrated in the power supply. or 20…30 V DC – ± % tolerance – filtered and regulated – connection to main supply: permanent (through external SELV and LPS power supply) Power consumption Max. 96 VA Medium data Fluid Water without particles: drinking water, industrial water Fluid pH range1.) pH 4…pH 9 Fluid conductivity • 50 µS/cm if there is no pH sensor cube 100 µS/cm if there is one pH sensor cube Temperature of the fluid sample + 3…+ °C (+ 37…+ 104 °F) Pressure of the fluid sample Refer to See data sheets of the sensor cubes and accessories, use the lowest pressure Flow rate of the fluid sample Min. flow rate: 6 l/h per installed sensor module, so with e.g. 3 sensor modules the min. flow rate is 6 18 l/h due to parallel installation.

4 | 12Visit product website  Connection & communication Sensor cube • Max. 6 internal sensor cubes, max. 2 measurement water Max. connection of 30 external sensor cubes via Bürkert-Systembus (büS) Max. büS length 100 m (without T-connections) Electrical connection • Housing containing the electronic modules: 2 terminal blocks – male terminal block to connect the power supply to the system – female terminal block to feed the power supply to the sensor modules Housing containing the sensor modules: 2 M12 connectors – male M12 connector to connect the power supply for the sensor modules – female M12 connector to connect the power supply to an external device. Approvals and Certificates Directives CE directive The applied standards, which verify conformity with the EU Directives, can be found on the EU Type Examination Certificate and/or the EU Declaration of conformity (if applicable) Environment and installation Installation Wall mount unit, click system with wall-mounting bracket Ambient temperature • Operation: + 3…+ °C (+ 37…+ 104 °F) Storage: - 20…+ °C (- 4…+ 140 °F) (without sensor cube) Relative air humidity < %, without condensation Height above sea level Max. 2000 m Operating condition Continuous Equipment mobility Fixed Application area Indoor Degree of protection according to IEC/EN 60529 IP65 with closed and tight housings Installation category • With an AC switched-mode power supply: category II, according to UL/EN 61010 With a direct DC power supply: Category I, according to UL/EN 61010 Pollution degree Degree 2, according to UL/EN 61010 1 with closed and tight housings 1.) When a chlorine sensor cube is present within the system: pH value is restricted to pH 5…pH 9

5 | 12Visit product website  2. Materials 2.1. Chemical Resistance Chart – Bürkert resistApp Bürkert resistApp – Chemical Resistance Chart You want to ensure the reliability and durability of the materials in your individual application case? Verify your combination of media and materials on our website or in our resistApp. Start Chemical Resistance Check 2.2. Material specifications No. Material

1 Stainless steel

2 PC, glass fibre reinforced, anthracite grey

3 Glass

4 PC, black

5 Stainless steel

6 Stainless steel

7 PC, transparent

8 Stainless steel

9 PC, black

10 Bio polymer, EPDM

11 Stainless steel

12 PC, black

6 | 12Visit product website  3. Dimensions Note: Dimensions in mm, unless otherwise stated 192 186 497 236 280 430 554 375

7 | 12Visit product website  4. Product design and assembly 4.1. Product assembly Housing for the electric modules The device is always equipped with the following electronic modules: HMIU (Human Machine Interface Unit) incl. USB slot and Ethernet connection 7" touchscreen incl. USB slot Option: PSU mains supply 100…240 V AC x büS connector A total of 7 slots (5 for 230 V/115 V AC variant) are available for electronic modules: Digital and analogue inputs and outputs Fieldbus gateway The main housing parts for the electric modules are shown in the following drawing. Depending on the configuration of the device and for a complete description and for the technical data related to the electronic mod ules, refer to the data sheets of each electronic modules. See data sheet Type ME2X for more information. AC power supply module (depends on the version) HMIU module

8 | 12Visit product website  Housing for the sensor cubes The device can contain one to six sensor cubes. The main housing parts for the sensor cubes are shown in the following drawing. Depending on the configuration of the device and for a complete description and for the technical data related to the sensor cubes, refer to the data sheets of each sensor cubes (see following table). Sample water pipes connections (inlet and outlet) büS connector Sensor cubes on fluidic backplane Mounting rail for fluidic backplane Sensor cubes Measured physical value Marking of the push buttons pH sensor cube, see data sheet Type MS01  pH and temperature Chlorine sensor cube, see data sheet Type MS02  Chlorine, chlorine dioxide and temperature Conductivity sensor cube, see data sheet Type MS03  Conductivity and temperature ORP sensor cube, see data sheet Type MS04  Redox potential Turbidity sensor cube, see data sheet Type MS05  Turbidity (ISO and EPA)

9 | 12Visit product website  Mechanical interfaces of the sensor cubes All the fluidic backplanes for the sensor cubes have the same design. Thus any sensor cube can be plugged on any mechanical interface. The backplanes are connected to each other and feed the sensor cubes parallel with the power supply, the sample water and serial büS connection. Position of the lever if no sensor cube is plugged in if a sensor cube is plugged in Electrical contacts Security pin Fluid outlet Fluid inlet Bayonet Bayonet lever to the right Fluid inlet and fluid outlet are closed and tight Bayonet lever to the left Fluid inlet and fluid outlet are open Electrical contacts Security pin Fluid outlet Fluid inlet Bayonet Bayonet lever to the right Fluid inlet and fluid outlet are closed and tight Bayonet lever to the left Fluid inlet and fluid outlet are open 5. Product accessories Note: To set up a device without a display, use the USB-büS interface, Type 8923 and the Bürkert Communicator Type 8920. See Software manual Type 8920  for more information. Accessories No. Description USB-büS interface Type 8923 (to be ordered separately, see chapter “6.5. Ordering chart accessories” on page 11

1 Quick-Start

2 Power supply: 100…240 V AC/ 24 V DC 1 A and adaptors for power supply

3 büS terminating resistor on büS Y-splitter 4 5-pin M12 circular male connector wired on free end cable 5 büS connection cable with 5-pin M12 circular male connector, micro USB B plug 6 büS adapter with 5-pin M12 circular male connector, A-coded to 5-pin M12 circular male connector, A-coded 7 büS stick (USB to büS/CANopen adaptor) 8 büS service cable with 5-pin M12 circular female connector, mini USB and circular plug-in connectors for power supply

9 Magnetic key

10 CD - Communicator (30-day license without registration, update and licens-

ing over Bürkert home page)

10 | 12Visit product website  6. Ordering information 6.1. Bürkert eShop – Easy ordering and quick delivery Bürkert eShop – Easy ordering and quick delivery You want to find your desired Bürkert product or spare part quickly and order directly? Our online shop is available for you 24/7. Sign up and enjoy all the benefits. Order online now 6.2. Recommendation regarding product selection The Online Analysis System Type 8905 is a compact and modular system in a single housing, offering a wide range of configuration possibilities. Thank you for your interest in our products! In order to provide you with the best possible advice, please contact your local Bürkert branch office for customised system design. 6.3. Bürkert product filter Bürkert product filter – Get quickly to the right product You want to select products comfortably based on your technical requirements? Use the Bürkert product filter and find suitable articles for your application quickly and easily. Try out our product filter 6.4. Ordering chart Note : This table shows exemplary configurations of the online analysis system. Description Operating voltage Equipment Article no. MS01 sensor cube pH MS02 sensor cube Chlorine MS03 sensor cube Conduc- tivity MS04 sensor cube ORP MS05 sensor cube Turbidity PSU: incl. 100…240 V AC power supply Online Analysis System – pH, Conductivity, Turbidity

24 V DC 1 – 1 – 1 – On request

100…240 V AC 1 – 1 – 1 1 Online Analysis System – pH, Chlorine, Turbidity

24 V DC 1 1 – – 1 –

100…240 V AC 1 1 – – 1 1 Online Analysis System – pH, ORP, Conductivity, Turbidity

24 V DC 1 – 1 1 1 –

100…240 V AC 1 – 1 1 1 1 Online Analysis System – pH, Chlorine, ORP, Turbidity

24 V DC 1 1 – 1 1 –

100…240 V AC 1 1 – 1 1 1 Online Analysis System – pH, Chlorine, Conductivity, ORP, Turbidity

24 V DC 1 1 1 1 1 –

100…240 V AC 1 1 1 1 1 1

11 | 12Visit product website  6.5. Ordering chart accessories Description Article no. Set including the wall-mounting bracket with four self-adhesive bumpers 566363  Sample water pipe 4/6 mm 5 m 567793  10 m 567701  25 m 567794  Strainer 100 µm 772703  Pressure reducer 772437  Bubble trap 568492  Set with a pressure reducer (including a 100 µm strainer, a sampling point and two G ¼" connections), a wall-mount- ing bracket with nut (for the pressure reducer), a pressure gauge (for the pressure reducer) and two quick-connect couplings 566319  Filter housing made of plastic with NBR seal for filter element 50 µm, inlet and outlet ¼" 774292  Filter housing made of plastic with NBR seal for filter element 90 µm or 140 µm, inlet and outlet ¼" 774287  Filter element 50 µm 774293  90 µm 774290  140 µm 774291  Type MZ20 cleaning system, 2 solutions See data sheet Type MZ20 Cleaning System for more information. 567124  Interface accessories büS Stick Set USB-büS-Interface Set 1, Type 8923 Detailed information can be found in chapter “5. Product accessories” on page 9 772426  USB-büS Interface Set 2, Type 8923 (only büS Stick, cable and büS service cable) 772551  Connectors and sockets büS Y-distributor, 5-pin M12 circular female connector to 5-pin M12 circular male and 5-pin M12 circular connectors 772420  büS Y-distributor, 5-pin M12 circular female connector to 5-pin M12 circular male and 5-pin M12 circular connectors (power interrupt) 772421  büS adaptor M12 circular male connector A-coded - M12 circular male connector A-coded 772867  büS termination, 5-pin M12 circular male connector 772424  büS termination, 5-pin M12 circular female connector 772425  Extensions 5-pin M12 straight circular female and male connectors moulded on büS cable, shielded 0.5 m 772403  1 m 772404  3 m 772405  5 m 772406  10 m 772407  20 m 772408  Software Software Bürkert Communicator Download Type 8920

Bürkert – Close to You Austria Belgium Czech Republic Denmark Finland France Germany Italy Netherlands Norway Poland Spain Sweden Switzerland Turkey United Kingdom China Hong Kong India Japan Korea Malaysia Philippines Singapore Taiwan South Africa United Arab Emirates Brazil Uruguay Canada USA Australia New Zealand Credits, © and concept: Christian Bürkert GmbH & Co. KG | Photographs: Marc Eggimann Fotografie - 4051 Basel | Scanner GmbH - Werbeagentur Künzelsau -

74653 Künzelsau

www.burkert.com