www.micropowerdirect.com MicroPower Direct
292 Page Street
Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com Key Features: 75W Output Power Meets EN 50155 EN 60950 Approved EN 50121-3-2 Compliant Wide Input Range 3,000 VAC rms Isolation Reinforced Insulation 92% Effi ciency Meets EN 61373 Remote On/Off MR75-xxSRW Compact, 75W Wide Input Railway DC/DC Con vert er Input Parameter Conditions Min. Typ. Max. Units Input Start Voltage 72 VDC Input 43.0 VDC110 VDC Input 66.0 Under Voltage Shutdown 72 VDC Input 40.0 VDC110 VDC Input 63.0 Input Filter PI (/H9266) Filter Output Parameter Conditions Min. Typ. Max. Units Output Voltage Accuracy ±1.0 % Line Regulation VIN = Min to Max ±0.2 % Load Regulation IOUT = 0% to 100% ±0.3 % Ripple & Noise (20 MHz) See Note 1 150 mV Pk-Pk Transient Response Time, See Note 2 25% Load Change 250 µS Temperature Coeffi cient ±0.02 %/°C Output Over Load Protection See Note 3 150 %IOUT Output Short Circuit Continuous (Hiccup Mode) General Parameter Conditions Min. Typ. Max. Units Isolation Voltage, Reinforced Insulation Input/Output 3,000 VAC rms Input/Output to Case 1,500 VDC Isolation Resistance 500 VDC 1,000 M Isolation Capacitance 100 kHz/1V 3,000 pF Switching Frequency 320 kHz Environmental Parameter Conditions Min. Typ. Max. Units Operating Temperature Range Ambient, See Note 4 -40 +25 +61 °C Thermal Impedance, Without Heat Sink Natural Convection 7.5 °C/W100 LFM 6.1 200 LFM 5.3 400 LFM 3.9 Thermal Impedance, With Heat Sink Natural Convection 6.8 °C/W100 LFM 4.1 200 LFM 3.3 400 LFM 2.2 Operating Temperature Range Base Plate -40 +105 °C Thermal Shutdown Base Plate +110 °C Cooling See Derating Curves (Page 3) Humidity RH, Non-condensing 95 % Physical Case Material Black Anodized Aluminum Case with Aluminum Plate/Heat Sink Weight 2.6 Oz (74.0g) Remote On/Off Parameter Conditions Min. Typ. Max. Units Unit On 3.5 VDC - 12.0 VDC or Open Circuit Unit Off 0 VDC - 1.2 VDC or Short Circuit Control Input Current, ON VCTRL = 5V 0.5 mA Control Input Current, OFF VCTRL = 0V -0.5 mA Control Common Referenced to -VIN (Pin 3) Standby Input Current 2.5 mA Reliability Specifi cations Parameter Conditions Min. Typ. Max. Units MTBF MIL HDBK 217F , 25°C, Gnd Benign 143.8 kHrs Absolute Maximum Ratings, See Note 5 Parameter Conditions Min. Typ. Max. Units Input Voltage Surge (100 mS) 77 VDC Input -0.7 165.0 VDC110 VDC Input -0.7 250.0 Lead Temperature 1.5 mm From Case for 10 Sec 260 °C Electrical Specifi cations Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice. Series
292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com www.micropowerdirect.comModel Selection Guide Notes: 1. Output noise is measured with a 10 µF tantalum capacitor and a 1.0 µF ceramic capacitor connected in parallel across the output. Ripple & noise is 150 mV typical for 24 VDC output models. 2. Transient recovery is measured to within a 1% error band for a load step change of 75% to 100%. 3. Output overload protection is provided by a “hiccup” mode circuit 4. The ambient temperature range is the maximum possible for a converter with a heatsink mounted. Natural convection is 20 LFM, not “still air”. See the power derating curves on page 3 for the operating temperature limits for specifi c models. Model Number Input Output Refl ected Ripple Current (mA Typ) Over Voltage Protection (VDC) Capacitive Load (µF , Max) Effi ciency (%, Typ) Fuse Rating Slow-Blow (mA) Voltage (VDC) Current (mA) Voltage (VDC) Current (A)Nominal Range Full-Load No-Load MR75-72S05RW 72 43 - 101 1,170 50 5.0 15.000 35 6.2 25,500 89 3,200 MR75-72S12RW 72 43 - 101 1,132 45 12.0 6.250 35 15 4,400 92 3,200 MR75-72S15RW 72 43 - 101 1,132 45 15.0 5.000 35 18 2,800 92 3,200 MR75-72S24RW 72 43 - 101 1,145 55 24.0 3.125 35 27 1,100 91 3,200 MR75-110S05RW 110 66 - 160 766 40 5.0 15.000 35 6.2 25,500 89 2,100 MR75-110S12RW 110 66 - 160 749 35 12.0 6.250 35 15 4,400 91 2,100 MR75-110S15RW 110 66 - 160 749 35 15.0 5.000 35 18 2,800 91 2,100 MR75-110S24RW 110 66 - 160 758 50 24.0 3.125 35 27 1,100 90 2,100 Typical Connection EMC Specifi cations Notes: 1. To meet EN 55011 Class A, and EN 50121-3-2, an external input fi lter is required. See the connection diagram below for a typical circuit. 2. To meet EN 61000-4-4 and EN 61000-4-5, a capacitor should be connected across the input pins. See the con- nection diagram below for a typical example. 5. Exceeding absolute maximum ratings may damage the module. These are not continuous operating ratings. 7. Operation at no-load will not damage these units, but they may not meet all specifi cations. 8. If the remote sense outputs are not used, the +Sense (pin 7) should be connected to OUT (pin 8) and the -Sense (pin 5) should be connected to -VOUT (pin 4). 9. It is recommended that a fuse be used on the input of a power supply for protection. For the correct rating, see the model selection table above. Parameter Standard Level Radiated Emissions See Note 1 EN 50121 Class A Conducted Emissions See Note 1 EN 55011 Class A ESD EN 61000-4-2 Criteria A; ±8 kV Air, ±6 kV Contact RS EN 61000-4-3 Criteria A; 10V/m EFT See Note 2 EN 61000-4-4 Criteria A; ±2 kV Surge See Note 2 EN 61000-4-5 Criteria A; ±1 kV CS EN 61000-4-6 Criteria A; 10 V/m Environmental Standards Parameter Standard Vibration & Shock EN 61373 Cooling Test EN 60068-2-1 Dry Heat EN 60068-2-2 Damp Heat EN 60068-2-30 For applications that require meeting EMC/EMI standards, the diagram above illustrates a typical connection of the MR75-xxxSxxRW series. The units do not require external components to operate as specifi ed. Some notes on this diagram (starting with the input circuit) are: 1. It is recommended that an external slow blow fuse be used. The recom- mended fuse rating is shown in the table at right. 2. To meet EN 55011 Class A & EN 50121-3-2, an external input fi lter is required. In the diagram this fi lter consists of C 1 and L1. The recom- mended component values are shown in the table at right. 3. To meet EN 61000-4-4 and EN 61000-4-5, a capacitor should be connected across the input pins. In the connection diagram above, the value of C 1 should be changed to 470 µF/200V. 4. Recommended values for components are: Component 72 VIN 110 VIN Fuse 3,200 mA 2,100 mA C1 68 µF/200V 68 µ F/200V L1 450 µH 450 µ H C3 2,200 pF/3 kV 2,200 pF/3 kV C4 2,200 pF/3 kV 2,200 pF/3 kV C5 2,200 pF/3 kV 2,200 pF/3 kV C6 2,200 pF/3 kV 2,200 pF/3 kV C7 4.7 µF 4.7 µF 5. The circuit consisting of R1, Q1 and C2 illustrates a simple open collector connection for the remote on/off control. The resistor (R1) limits the current on the control line and the capacitor (C2) bypasses noise spikes, helping to prevent phantom triggering of the control. If the control pin is not being used, it should be left open. 7. The resister R2 is connected as an output adjust. The output adjustment capability is explained further on page 3. 8. The output sense pins (pin 7 and pin 5) may be used to compensate for the losses incurred over long leads to an output load. If not used for load compensation or output adjustment, the sense pins should be connected directly to the appropriate output pins, pin 7 to pin 8 and pin 5 to pin 4. 9. The output fi ltering capacitor (C 7) is a low ESR (<1/H9024) electrolytic capacitor. Care must be taken in choosing this capacitor not to exceed the capacitive load specifi cation for the unit.
MicroPower Direct • 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com www.micropowerdirect.com MicroPower Direct • 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com www.micropower direct.comwww.micropowerdirect.com MR75-110S24RW with Heatsink MR75-110S24RW without Heatsink MR75-72S24RW, MR75-110S12RW & MR75-110S15RW with Heatsink MR75-72S24RW, MR75-110S12RW & MR75-110S15RW without Heatsink MR75-72S12RW & MR75-72S15RW with Heatsink MR75-72S12RW & MR75-72S15RW without Heatsink Derating Curves MR75-72S05RW & MR75-110S05RW with Heatsink MR75-72S05RW & MR75-110S05RW without Heatsink
We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com www.micropowerdirect.com Mechanical Dimensions - With Optional Heatsink Mechanical Notes:
- All dimensions are typical in inch es (mm)
- Tolerance x.xx = ±0.02 (±0.50) www.micropower direct.co mwww.micropowerdirect.com MicroPower Direct We Power Your Success - For Less!We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com Pin Description 1+ V IN
2 Remote On/Off
6 Trim
Description
-Sense Trim +Sense OUT Pin Connecti For the heatsink option, add suffi x “H” to the model number (i.e. MR75-110S12RW-H) Output Voltage Adjustment A simple external circuit may be used to adjust the converter output. The range of adjustment is ±10%. To adjust the output down, connect a 5%, 3W resistor from the plus sense pin (7) to the VOUT trim pin (6). To adjust the output up, connect a 5%, 3W resistor from the minus sense pin (5) to the V OUT trim pin. For up/ down trimming, connect a 10 k/H9024 potentiometer from the plus to the minus sense pins. Connect the wiper arm to the V OUT trim pin. For a table of trim resistor values, contact the factory.