Key Features: 15W Output Power 40 - 160 VDC Input Range Meets EN 60950, EN 50155 1,500 VDC Isolation Effi ciency to 89% Compact 1 x 2 Inch Case -40°C to +85°C Operation Industry Standard Pin-Out Chassis Mount Option DIN Rail Mount Option MR1511S Ultra-Wide Input, 15W Compact, Railway DC/DC Con vert ers Input Parameter Conditions Min. Typ. Max. Units Input Voltage Range 40.0 110.0 160.0 VDC Input Start Voltage 39.8 VDC Under Voltage Shutdown I OUT = 100% 36.0 VDC Input Filter /H9266 (Pi) Filter Output Parameter Conditions Min. Typ. Max. Units Output Voltage Accuracy ±1.0 ±3.0 % Output Trim Range ±10 % Line Regulation VIN = Min to Max ±0.2 ±0.5 % Load Regulation I OUT = 10% to 100% ±0.5 ±1.0 % Ripple & Noise (20 MHz) See Note 1 75 100 mV P - P Transient Recovery Time, See Note 2 25% Load Step Change 500 800 µS Transient Response Deviation ±3.0 ±5.0 % Output Power Protection 110 130 170 % Temperature Coeffi cient ±0.02 %/°C Output Short Circuit, See Note 3 Continuous (Autorecovery) General Parameter Conditions Min. Typ. Max. Units Isolation Voltage 60 Seconds 1,500 VDC Isolation Resistance 500 VDC 1,000 M Isolation Capacitance 100 kHz/0.1V 2,000 pF Switching Frequency 300 kHz Environmental Parameter Conditions Min. Typ. Max. Units Operating Temperature Range Ambient -40 +25 +85 °C Operating Temperature Range Case +105 °C Storage Temperature Range -55 +125 °C Cooling Free Air Convection Humidity RH, Non-condensing 95 % Physical Case Size See Mechanical Diagram (Page 4) Case Material Aluminum Alloy With Non-Conductive Base (UL94-V0) Weight 0.99 Oz (28g) Remote On/Off Parameter Conditions Min. Typ. Max. Units Unit On See Note 4 2.5 12.0 VDC Unit Off See Note 4 0 1.2 VDC Off Idle Current 1.0 mA Reliability Specifi cations Parameter Conditions Min. Typ. Max. Units MTBF MIL HDBK 217F , 25°C, Gnd Benign 1.0 MHours Vibration, 5 - 150 Hz Displacement Range 7.5 mm Acceleration 2G Absolute Maximum Ratings Parameter Conditions Min. Typ. Max. Units Input Voltage Surge (1 Sec) -0.7 200.0 VDC Lead Temperature 1.5 mm From Case for 10 Sec 300 °C Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. Electrical Specifi cations Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice. www.micropowerdirect.com MicroPower Direct
292 Page Street
Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com Series
292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com www.micropowerdirect.com Model Number Input Output Effi ciency (%, Typ) Over Voltage Protection (VDC Typ) Capacitive Load (µF , Max) Fuse Rating Slow-Blow (mA) Voltage (VDC) Current (mA) Voltage (VDC) Current (mA, Max) Current (mA, Min)Nominal Range Full-Load No-Load MR1511S-03RU 110 40 - 160 120 15 3.3 4,000 200 87 4.1 4,020 300 MR1511S-05RU 110 40 - 160 153 15 5.0 3,000 150 89 6.2 4,020 300 MR1511S-12RU 110 40 - 160 155 8 12.0 1,250 63 88 15.0 1,600 300 MB1511S-15RU 110 40 - 160 155 8 15.0 1,000 50 88 18.0 1,000 300 MB1511S-24RU 110 40 - 160 155 8 24.0 625 32 88 28.8 470 300 Derating Curve External Trim External Trim Notes: On single output units, an external resistor can be used to adjust the converter output up/down by about 10%. The connection is shown in the diagram at left. The required resistor value is calculated by the formulas: Where R TRIM = Value of the external trim resistor V TRIM = Amount of voltage adjustment required The value of R1, R2, R3 and VREF are given in the table below. Trim Down= RTRIM = R1 - A A $ R1 - R3 Where A = VREF VTRIM - VREF $ R2 Trim UP= RTRIM = R2 - A A $ R2 - R3 Where A = VTRIM - VREF VREF $ R1 Parameter Output Voltage (VDC) 3.3 5.0 12 15 24 Effi ciency vs Output Power (VIN= 110 VDC) Effi ciency vs Input Voltage (Full Load) Notes: 1. When measuring output ripple, it is recommended that an external ceramic capacitor (approx 10 µF) be placed from the +VOUT to the -VOUT pins. 2. Transient recovery is measured to within a 1% error band for a load step change of 25%. 3. Short circuit protection is provided by a “hiccup mode” circuit. 4. The maximum control current at the on/off pin (pin 6) during a logic high is 50 µA. The maximum control current to the on/off pin at logic low (-0.7V to 0.8V) is 1 mA. If the on/ off pin is left open, the unit operates. If it is grounded, the unit will shut off. 5. These units should not be operated with a load under 5% of full load. Operation at no-load will not damage the unit, but they may not meet all specifi cations. 6. These units should not be operated over +85°C. Exceeding +85°C may damage the unit. 7. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection table above for the correct rating.
MicroPower Direct • 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com www.micropowerdirect.comEMC Specifi cations Parameter Standard Criteria Transient Input Voltage, See Note 1 RIA 12 A 385V/20mS Criteria A Maximum Input Voltage, See Note 2 EN 50155 B 1,800V (5/50 µS, 50 OR 100/H9024 B 8,400V (0.05/0.1 µS, 100/H9024 Radiated Emissions, See Note 3 EN 55022 Class B Conducted Emissions, See Note 3 EN 55022 Class B ESD EN 61000-4-2 B ±6 kV Contact RS EN 61000-4-3 A 10V/m EFT, See Note 4 EN 61000-4-4 B ±2 kV Surge, See Note 5 EN 61000-4-5 B ±2 kV/ ±4 kV CS EN 61000-4-6 A 3 Vrms Voltage Dips EN 61000-4-29 B 0% - 70% Typical Connection The diagram above illustrates a typical connection of the MR1511S series The MDCFM-40U fi lter module is used to make the circuit compliant with input surge and EMC standards EN 55022, EN61000 and EN 50155. This can also be accomplished by using external fi lter components as shown in the board layout drawing below. Some notes on these components are: 1. It is recommended that an external fuse be used. The recommended fuse is shown in the model chart on page 2. 2. An external MOV is recommended on the input to protect the unit in the event of a surge. A recommended value is given in the table at right. 3. An external TVS is recommended on the input to protect the unit in the event of a voltage spike. A recommended value is given in the table at right. 4. The output fi ltering capacitor (C 3) is a high frequency, low resistance electrolytic capacitor. Care must be taken in choosing this capacitor not to exceed the capacitive load specifi cation for the unit. Voltage derating of capacitors should be 80% or above. Notes: 1. With a pulse interval that is >60S. Requires the addition of the fi lter module MDCFM-40U (or a similar discrete fi lter circuit) as shown in the circuit/ board layout diagrams below. Contact the factory for more information. 2. With a pulse interval that is >60S. Requires the addition of the fi lter module MDCFM-40U (or a similar discrete fi lter circuit) as shown in the circuit/ board layout diagrams below. Contact the factory for more information. 3. All units will meet class B with the addition of the MDCFM-40U (or a similar discrete fi lter circuit) as shown in the circuit/board layout diagrams below. Contact the factory for more information. 4. To meet the requirements of EN 61000-4-4 (±2 kV), external components are needed. This can be done discretely, or with the addition of the MDCFM-40U. Contact the factory for more information. 5. To meet the requirements of EN 61000-4-5 (±2 kV/±4 kV), external com- ponents are needed. This can be done discretely, or with the addition of the MDCFM-40U. Contact the factory for more information. Typical Board Layout: With External Filter/Surge Components 5. Suggested component values are: Component Value MOV S14K130 L1 56 µH TVS SMCJ170A C1 100 µF/200V C3 1.0 µF/50V L2 4.7 µH CY1, CY2 1,000 pF/2 kV 6. Input noise and surge suppression modules are available for a number of MPD DC/DC power supplies. For use with Typical Board Layout: With External Filter Module Vin (VDC) Input Capacitor Vout (VDC) Output Capacitor 110 100 µF 3.3 470 µF 5 470 µF 12 220 µF 15 220 µF 24 100 µF the MRxx11S product series, the MDCFM-40U DC fi lter modules are recommended. For pricing or full technical information, please contact the factory. 7. In many applications simply adding input/output capaci- tors will enhance the input surge protection and reduce output ripple suffi ciently. In this case, the capacitors C 1 and C3 would be connected as shown without the other fi lter components. Recommended capacitor values are given in the table above.
We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com www.micropowerdirect.com Notes:
- All dimensions are typical in inches (mm)
- Tolerance x.xx = ±0.02 (±0.50) Mechanical Dimensions Mechanical Dimensions: With Optional Heatsink 1+ V IN 1+ V IN 2- V IN 2- V IN 3+ V OUT 3+ V OUT
4 Trim 4 Common
6 Remote On/Off 6 Remote On/Off
For the heatsink option, add suffi x “H” to the model number (i.e. MR1511S-xxRU-H) Adapter Plate All models of the MR1511S-xxRU series are available mounted on an adapter plate similar to the one pictured above. The adapter plate makes it easier to mount the unit to a chassis or to a standard DIN rail. Please contact the factory for more information.