DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 5

Technical content

www.micropowerdirect.com MicroPower Direct

292 Page Street

Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com Key Features:  15W Output Power  10:1 Input Range  4,000 VAC Isolation  Meets EN 62109  Wide -40°C to +70°C Oper.  Reverse Input Volt Prot.  Output Over Volt Protection  Compact Case  >300 kHours MTBF  Chassis/DIN Rail Options MPV1560RI4 Ultra Wide Input, Compact Industrial Grade, PV Power DC/DC Con vert ers Input Parameter Conditions Min. Typ. Max. Units Input Voltage Range 100 600 1,000 VDC Input Current 200 VDC Input 120.0 mA600 VDC Input 40.0 1,000 VDC Input 22.0 Inrush Current 200 VDC Input 7.0 A600 VDC Input 20.0 1,000 VDC Input 30.0 Start-Up Time V IN = 200 - 1,000 VDC 1.0 S Output Parameter Conditions Min. Typ. Max. Units Output Voltage Accuracy ±1.0 ±2.0 % Line Regulation VIN = MIN to MAX ±0.5 ±1.0 % Load Regulation I OUT = 0% to 100% ±0.5 ±1.0 % Ripple & Noise (20 MHz) See Note 1 100 200 mV P - P Temperature Coeffi cient ±0.02 %/°C Over Current Protection Hiccup Circuit, Autorecovery 110 % I OUT Output Short Circuit Continuous (Autorecovery) General Parameter Conditions Min. Typ. Max. Units Isolation Voltage 60 Seconds 4,000 VAC Switching Frequency 75 kHz EMI Characteristics Parameter Standard Criteria Level Radiated Emissions, See Note 2 EN 55022 Class A Conducted Emissions, See Note 2 EN 55022 Class A ESD EN 61000-4-2 B ±6 kV Contact ±8 kV Air RS EN 61000-4-3 A 10V/m EFT, See Note 3 EN 61000-4-4 B ±4 kV Surge, See Note 4 EN 61000-4-5 B ±2 kV L-L CS EN 61000-4-6 A 10 Vrms Environmental Parameter Conditions Min. Typ. Max. Units Operating Temperature Range Ambient -40 +25 +70 °C Storage Temperature Range -40 +105 °C Cooling Free Air Convection Humidity RH, Non-condensing 95 % Physical Case Size, Module, Chassis /DIN Rail Mount See Mechanical Drawings (Starting Page 4) Case Material Black, Flame Retardant, Non-Conductive Plastic (UL94-V0) Weight, Module, Chassis /DIN Rail Mount See Mechanical Drawings (Starting Page 4) Reliability Specifi cations Parameter Conditions Min. Typ. Max. Units MTBF MIL HDBK 217F , 25°C, Gnd Benign 300 kHours Absolute Maximum Ratings Parameter Conditions Min. Typ. Max. Units Lead Temperature, See Note 5 Wave Soldering 255 260 265 °CManual Soldering 350 360 370 Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. Electrical Specifi cations Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice.

www.micropowerdirect.com Page 2 We Power Your Success - For Less Model Number Input Output Effi ciency (%, Typ) Over Voltage Protection (VDC Typ) Capacitive Load (µF , Max) Fuse Rating Slow-Blow (A) Voltage (VDC) Voltage (VDC) Current (mA, Max) Current (mA, Min)Nominal Range MPV1560S-12RI4 600 100 - 1,000 12.0 1,250 0.0 77 15.0 2,000 2.0 MPV1560S-15RI4 600 100 - 1,000 15.0 1,000 0.0 78 19.0 1,200 2.0 MPV1560S-24RI4 600 100 - 1,000 24.0 625 0.0 80 28.0 470 2.0 Notes: 1. To meet the specifi ed ripple and noise levels, external capacitors are required. See the “Simple Connection” diagram below. Recommended values for all external components are given in the table at the bottom of the page. For more information, please contact the factory. 2. All units will meet EN 55022 (CE/RE) class A with the input circuit shown in the “Typical Connection” diagram below. Contact the factory for more information. 3. All units will meet EN 61000-4-4 (±4 kV) with the input circuit shown in the “Typical Connection” diagram below. Contact the factory for more information. Model Selection Guide Simple Connection Typical Connection: With External EMC Components 5. Recommended values for components are: Model Number External Components Fuse MOV NTC LDM LCM C 1, C2, C3, C4 R1, R2, R3, R4 C5 C6 TVS MPV1560S-12RI4 2A/1 kV SK14880 10D-11 4.7 mH/0.38A 10 mH/0.5A 47 µF/400V 1 M/H9024/2W 1 µF/50V 120 µF/25V SMBJ15A MPV1560S-15RI4 SMBJ20A MPV1560S-24RI4 68 µF/35V SMBJ33A For applications that require meeting higher EMC standards, the circuit shown above is recommended. Some notes on this diagram (starting with the input circuit) are: 1. It is recommended that an external fuse be used. The recommended fuse is 2A/1,000V. 2. The NTC helps to prevent damage to the module in the event an input current surge occurs. The recommended value is given in the table below. 3. The MOV helps to prevent damage to the module in case an input voltage surge occurs. The recommended value is given in the table below. 4. Capacitors C 1, C2, C3 and C4 are input fi lter components (connected in series to achieve the required capacitance level). Resistors R1, R2, R3 and R4 help to balance the current across the capacitors. The diagram at left illustrates a typical connection of the MPV1560S-xxRI4 series. Output capacitors C 6 and C5 are fi ltering components. They are required to meet ripple and noise specifi cations. Capacitor C5 is ceramic and capacitor C6 is a high frequency, low ESR electrolytic. The recommended input components are a fuse, NTC, and MOV. The recommended component values for these are given in the table below. 6. Capacitor C 5 is ceramic. This capacitor is used to fi lter high frequency noise. A recommended value is given in the table below. 7. Capacitor C 6 is an electrolytic. A low ESR, high frequency capacitor should be used. The recommended value is given in the table below. 8. The output TVS will help protect system circuitry if power supply fails. A recommended value is given in the table below. 9. Derating on all capacitors should be 80% or more. 10. To meet safety regulations, the board trace widths should be >3 mm, the distance between traces should be >6 mm, and the distance between traces and ground should be >6 mm. Contact the factory for more information. 4. All units will meet the requirements of EN 61000-4-5 (±1 kV/±2 kV), with the input circuit shown in the “Typical Connection” diagram below. Contact the factory for more information. 5. Lead temperature is measured 1.5 mm from the case. 6. Operation at no load will not damage the units, however, they may not meet all specifi cations. 7. It is recommended that a fuse be used on the input of a power supply for protection. For the MPV1560RI4 series, a 2.0A slow blow, with a voltage rating over 1 kV, should be used.

MPD • 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com www.micropowerdirect.com Temperature Derating Curve: VIN = 100 to 150V Effi ciency vs Output Power (VIN= 500 VDC) Effi ciency vs Input Voltage (Full Load) Temperature Derating Curve: VIN = 150 to 1,000V Input Voltage Derating Curve: Ambient Temp = 25°C The MPV1560S-xxRI4 series is designed to be operated in an environment that has natural air cooling. It should not be used in a closed or sealed environment. For more information, contact the factory.

www.micropowerdirect.com Page 4 We Power Your Success - For Less Mechanical Dimensions Pin Function

1 No Connection

Notes:

  • All dimensions are typical in inches (mm)
  • General Dimension Tolerance x.xx = ±0.02 (±0.50)
  • Pin Diameter Tolerance x.xxx = ±0.004 (±0.100)
  • Weight: 0.3.35 Oz (95g) All models of the MPV1560S-xxRI4 series are available assembled on adapter plates for mounting to a chassis or on a DIN rail. Similar to the product pictured at right. Mechanical dimensions for these adapters are shown in the diagrams below and on the following page. To order the product assembled on an adapter, add the designation for the adapter to the end of the product number. For example: MPV1560S-12RI4-A2C. Please contact the factory for more information. Mechanical Dimensions, A2C : With Chassis Mount & Power Good LED Notes:
  • All dimensions are typical in inches (mm)
  • General Dimension Tolerance x.xx = ±0.02 (±0.50)
  • Wire Range: 12 to 24 AWG
  • Tightening Torque: 0.4 Nm Max
  • Weight: 0.5.26 Oz (150g)
  • The LED indicates the output voltage is present (LED “On”) Pin Con nec tions Pin Function Pin Function 1- V IN 5 No Connection

2 No Connection 6 No Connection

We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com www.micropowerdirect.com Mechanical Dimensions, A4C: With DIN Rail Mount Option & Power Good LED Notes:

  • All dimensions are typical in inches (mm)
  • General Dimension Tolerance x.xx = ±0.02 (±0.50)
  • Wire Range: 12 to 24 AWG
  • Tightening Torque: 0.4 Nm Max
  • Weight: 6.66 Oz (190g)
  • For use with a TS35 type DIN rail
  • The LED indicates the output voltage is present (LED “On”) Pin Function Pin Function 1- V IN 5 No Connection

PV DC/DC’s MPD offers a wide variety of DC/DC converters specifi cally designed for photovoltaic power systems. Typical features include: Call today for complete information or product samples.  Ultra wide 10:1 & 12:1 input ranges  4 kVAC Isolation  5W to 40W Output Power  EN 62109 Compliance  Rugged, Compact Packaging  -40°C to + 70°C Operation  High Reliability  Chassis Mounting Available  DIN Rail Mounting Available