DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

Parameter Conditions Min. Typ. Max. Units Input Voltage Range Universal 90 264 VAC Input Frequency 47 63 Hz Input Current, Full Load 90 VAC 10.0 A Inrush Current, Cold Start 110 VAC 35 A220 VAC 70 Leakage Current 264 VAC 2.0 mA Power Factor Correction Meets EN61000-3-2 Class D Input Protection T12A/250V Fuse Input Undervoltage Protection Under 80 VAC ±5 VAC Unit Shuts Down; Unit Recovers Over 86 VAC Output Parameter Conditions Min. Typ. Max. Units Output Voltage Adjustment By Trim Pot ±5.0 % Output Regulation, See Note 1 ±1.0 % Hold Time 120 VAC, 80% Load 20 mSec Ripple & Noise (20 MHz), See Note 2 See Model Selection Guide Overload Protection Foldback Circuit, Autorecovery 110 140 % Over Voltage Protection >130% of Rated Output Voltage. Recycle AC Input. Over Temperature Protection Autorecovery +85 ºC Temperature Coeffi cient ±0.04 %/ºC Transient Recovery Time, See Note 4 50% Load Change 2.5 mS Transient Response Deviation 5.0 % Overshoot/Undershoot At Turn On/Off ±5.0 % Turn On Delay 230 VAC 1.5 S Output Short Circuit Continuous With Autorecovery General Parameter Conditions Min. Typ. Max. Units Isolation Voltage, See Note 5 Input - Output 3,000 VACInput - FG (Frame Ground) 1,500 Primary - Core 1,500 Switching Frequency Fixed 24 kHz Interface Signals LED Power Supply On Bi-color LED Is Green For Power On; Orange When Protection Enabled Current Monitor A 0.5 to 3.0V Output That Represents 0% to 100% Output Current Current Share Optional For Sharing Up To Four Units. Contact The Factory For Details Remote Sense Compensates For Up To A 0.5V Line Drop Power Good Signal Goes TTL high 100 to 500 mS after regulation. Goes low at least 1 mS before the loss of regulation. Will sink 100 mA. Remote On/Off A TTL low signal inhibits the output. Hiccup mode. Environmental Parameter Conditions Min. Typ. Max. Units Operating Temperature Range Ambient 0 +25 +70 ºC Output Derating 2.5%/ ºC from +50 ºC to + 70 ºC Storage Temperature Range -20 +85 ºC Cooling See Model Selection Guide Operating Humidity RH, Non-condensing 90 % Reliability Specifi cations Parameter Conditions Min. Typ. Max. Units MTBF MIL HDBK 217F , 30ºC, Gnd Benign 100 kHours Safety Standards UL 60950, EN 60950 EMI Compliance Compliance to EN55022 (CISPR22) Class B; EN61000-3-2,3 EMS Immunity Compliance EN6100-4-2,3,4,5,6,11; EN55024; CE Marked (LVD) Vibration Sinusoidal 5~50 Hz, Acceleration ±7.35 m/s2 on X, Y & Z Axis Electrical Specifi cations Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice.Key Features:  Compact 600W Supply  PFC to EN 61000-3-2 “D”  EN 60950 Approved (UL)  Variable Speed Internal Fan  CE Certifi ed  FCC Class B Emissions  Universal AC Input  Current Share Option Single Output 600W Power Factor Corrected AC/DC Power Supplies www.micropowerdirect.com MicroPower Direct

292 Page Street

Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com

Output Voltage (VDC) Output Current (Max A) Max. Output Power (W) Ripple & Noise (% p-p) Effi ciency (%)PreSet Range MPU-600S-12YFI 12 VDC 12.0 - 14.0 50.00 600 ±1% 80% MPU-600S-24YFI 24 VDC 20.0 - 26.0 30.00 600 ±1% 83% MPU-600S-48YFI 48 VDC 48.0 - 60.0 12.50 600 ±1% 83% Notes: 1. Output regulation includes line & load. 2. Ripple & noise is measured from 10 Hz to 20 MHz. Connection to the unit is made with a 0.1 µF ceramic capacitor & a 22 µF electrolytic capacitor connected in parallel. 3. A 1% minimum load is required to maintain regulation & ripple specifi cations. 4. Transient recovery is measured to within a 1% error band for a load step change of 50% to 100%. 5. Isolation specifi cations are production HI-Pot tested for 3 seconds. 6. The full output range (see table) is covered in the safety agency certifi cation. Standard models are factory set to the Preset voltage, but may be set to other levels within the range without affecting the agency certifi cation. For more information, contact the factory. 7. Output power is given for the factory preset voltage. The maximum continuous output power level is 600W. All models provide a peak power level of 900W for a maximum duration of 500 µS. For more information, contact the factory. 8. Each unit includes an input fuse (250V/12A). Since this fuse is not fi eld replaceable, it is recommended that an external fuse of the same size be used on the input of the power supply for protection. MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072  TEL: (781) 344-8226  FAX: (781) 344-8481  E-Mail: sales@micropowerdirect.com Notes: All dimensions are typical in inches (mm)

  • Tolerance x.xx = ±0.02 (±0.50) www.micropowerdirect.com Model Number Models with other output voltage levels are available (i.e. 15 VDC, 36 VDC, etc) Contact the factory for details at: sales@micropowerdirect.com Pin Function

1 AC-Neutral

2 AC-Line

3 Field Ground

Input Connector (CN1):

  • Terminal Block: Howder HD-121-3P: M3.5 Screws 3 pins, 9.5 mm Centers
  • Molex Mating Part No: Molex 09-91-7000 or equivalent (two pins removed) Output Connector (CN2):
  • Terminal Block: Howder HD-121-8P: M3.5 Screws 8 pins, 9.5 mm Centers
  • Molex Mating Part No: Molex 09-91-2000 or equivalent Howder Molex Pin Function Pin Function 1-4 -V OUT 1-10 -V OUT 5-8 +V OUT 11-20 +V OUT Logic Signal Connector (CN3):
  • Mating Part No: JST XHP-7 or equivalent (CHYAO SHIUNN JS-2001-07) Pin Function 1 + Remote Sense 2 - Remote Sense

3 Remote On/Off

4 Power Good

5 Common

6 Current Share

7 Current Monitor

Fan Driver Connector (CN4):

  • Mating Part No: JST XHP-2 or equivalent (CHYAO SHIUNN JS-2001-2) Pin Function

1 Minus

2 Plus