DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

Parameter Conditions Min. Typ. Max. Units Input Voltage Range Universal 90 264 VAC Input Frequency 47 63 Hz Input Current, Full Load 90 VAC 5 A Inrush Current, Cold Start 110 VAC 35 A220 VAC 70 Leakage Current 240 VAC 300 µA Power Factor Correction Meets EN 61000-3-2 Class D Input Protection Two F5A/250V Fuse Output Parameter Conditions Min. Typ. Max. Units Output Voltage Adjustment By Trim Pot ±5.0 % Output Regulation, See Note 1 ±1.0 % Hold Time 120 VAC, 80% Load 16 mSec Ripple & Noise (20 MHz) See Note 2 See Model Selection Guide Overload Protection Foldback Circuit, Autorecovery 110 140 % Over Voltage Protection >130% of Rated Output Voltage. Recycle AC Input. Over Temperature Protection Autorecovery +110 ºC Temperature Coeffi cient ±0.04 %/ºC Transient Recovery Time, See Note 4 50% Load Change 2.5 mS Transient Response Deviation 5 % Overshoot/Undershoot At Turn On/Off ±5.0 % Turn On Delay 120 VAC 1 S Output Short Circuit Continuous With Autorecovery General Parameter Conditions Min. Typ. Max. Units Isolation Voltage, See Note 5 Input - Output 4,000 VACInput - FG (Frame Ground) 1,500 Primary - Core 1,500 Switching Frequency Fixed 70 kHz Interface Signals Power Supply On Green LED on the PCB Fan Fail An open collector output rated for 28V/5 mA sink current maximum. Goes high if a fan failure is detected Power Good Signal Goes TTL high 100 to 500 mS after regulation. Goes low at least 1 mS before the loss of regulation. Will sink 100 mA. Remote On/Off A TTL low signal inhibits the output. Hiccup mode. Environmental Parameter Conditions Min. Typ. Max. Units Operating Temperature Range Ambient 0 +25 +70 ºC Output Derating 2.5%/ ºC from +50 ºC to + 70 ºC Storage Temperature Range -20 +85 ºC Cooling See Model Selection Guide Operating Humidity RH, Non-condensing 90 % Reliability Specifi cations Parameter Conditions Min. Typ. Max. Units MTBF MIL HDBK 217F , 30ºC, Gnd Benign 100 kHours Safety Standards EN 60601 3RD Edition (UL) EMI Compliance Compliance to EN 55022 (CISPR22) Class B; EN 61000-3-2,3 EMS Immunity Compliance EN 6100-4-2,3,4,5,6, 8, 11; EN 55024; CE Marked (LVD) Vibration Sinusoidal 5~50 Hz, Acceleration ±7.35 m/s 2 on X, Y & Z Axis Electrical Specifi cations Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice. Single Output, 300W Medical Approved AC/DC Power Supplies www.micropowerdirect.com MicroPower Direct

292 Page Street

Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com Key Features:  Small 300W Supply  EN 60601-1 3RD Edition  PFC to EN 61000-3-2 “D”  Low Profi le <1U Height  600W Peak Power  Universal 90-264 VAC Input  Three Mechanical Options

Output Voltage (VDC) Output Current (Max A) Ripple & Noise (% p-p) Effi ciency (%)PreSet Range Convection With

25 CFM

MPU-300MS-12YZ 12 VDC 12.0 - 13.8 12.50 25.00 ±1% 80% MPU-300MS-15YZ 15 VDC 14.0 - 16.0 10.00 20.00 ±1% 80% MPU-300MS-24YZ 24 VDC 23.0 - 28.0 6.25 12.50 ±1% 80% MPU-300MS-48YZ 48 VDC 44.0 - 52.0 3.12 6.25 ±1% 80% Notes: 1. Output regulation includes line & load. 2. Ripple & noise is measured from 10 Hz to 20 MHz. Connection to the unit is made with a 0.1 µF ceramic capacitor & a 22 µF electrolytic capacitor connected in parallel. 3. A 1% minimum load is required to maintain regulation & ripple specifi cations. 4. Transient recovery is measured to within a 1% error band for a load step of 50% to 100%. 5. Isolation specifi cations are production HI-Pot tested for 3 seconds. 6. The full output range (see table) is covered in the safety agency certifi cation. Standard models are factory set to the Preset voltage, but may be set to other levels within the range without affecting the agency certifi cation. For more information, contact the factory. 7. Output power is given for the factory preset voltage. The maximum continuous output power level is 150W without providing 25 CFM airfl ow. All models provide a peak power level of 600W for a maximum duration of 500 µS. For more information, contact the factory. 8. Each unit includes two 250V/5A fuses. Since these fuses are not fi eld replaceable, it is recommended that an external fuse of the same size be used on the input of the power supply for protection. MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072  TEL: (781) 344-8226  FAX: (781) 344-8481  E-Mail: sales@micropowerdirect.com Notes: All dimensions are typical in inches (mm)

  • Tolerance x.xx = ±0.02 (±0.50) Connections Input Connector (CN1):
  • Terminal Block: Howder HD-601-3P 3 pins, 6.35 mm Centers
  • Molex Mating Part No: Molex 035977-0500 or equivalent (two pins removed) Pin Function

1 AC-Line

2 AC-Neutral

3 Field Ground

www.micropowerdirect.com Model Number Models with other output voltage levels are available (i.e. 36 VDC, etc) Contact the factory for details at: sales@micropowerdirect.com Output Connector (CN2):

  • Terminal Block (Must be used on 12 VOUT): Dinkle P-830N M5 Screws
  • Molex Mating Part No: Molex 035977-0600 or equivalent Pin Molex Pin Dinkle 1- V OUT 1- V OUT 2- V OUT 2+ V OUT 3- V OUT 4+ V OUT 5+ V OUT 6+ V OUT Logic Signal Connector (CN3):
  • Mating Part No: JST XHP-4 or equivalent (CHYAO SHIUNN JS-2001-04)
  • Mating Pins: JST SXH-002T-PO.6 For AWG 30 to 26 Pin Function

1 Remote On/Off

2 Fan Fail

3 Common

4 Power Good

Fan Driver Connector (CN4):

  • Mating Part No: JST XHP-3 or equivalent (CHYAO SHIUNN JS-2001-03) 3 Pins 0.98 Pitch Pin Function

1 Fan Fail

2 Minus

3 Plus