DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 6
Technical content
www.micropowerdirect.com MicroPower Direct
292 Page Street
Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com Single Output, 180W Compact, U-Channel AC/DC Power Supplies Key Features: 180W Output Power Universal 90-264 AC Input Power Factor Correction EN 60950 Approved Compact U-Channel Five Single Output Models Meets EN 55022 B “Finger Safe” Cover Avail. DIN Rail Kit Available MPU-120SSeries Electrical Specifi cations Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice. Input Parameter Conditions Min. Typ. Max. Units Input Voltage Range Universal 90 264 VAC 120 370 VDC Input Frequency 47 63 Hz Input Current See Model Selection Guide Inrush Current Cold Start, 115 VAC 30.0 A PkCold Start, 230 VAC 60.0 Power Factor Correction, See Note 1 115 VAC 0.99 W/VA230 VAC 0.95 Safety Ground Leakage Current 0.50 mA Output Parameter Conditions Min. Typ. Max. Units Output Voltage/Current See Model Selection Guide Output Voltage Accuracy ±2.0 % Line Regulation VIN = Min to Max ±1.0 % Load Regulation IOUT = 5% to 100% ±1.0 % Ripple & Noise (20 MHz), See Note 2 See Model Selection Guide Hold-Up Time 115 VAC 15 mSec Temperature Coeffi cient ±0.03 %/°C Over Voltage Protection >125% V OUT (Autorecovery) Overload Protection See Note 3 130 180 %I OUT Short Circuit Protection Continuous (Autorecovery) General Parameter Conditions Min. Typ. Max. Units Isolation Voltage Input to Output 4,000 VAC 5,656 VDC Input to Ground 2,000 VACOutput to Ground 500 Switching Frequency 65 kHz EMI Characteristics Parameter Standard Criteria Level Radiated Emissions EN 55022 B Conducted Emissions EN 55022 B Noise Immunity (EMS) EN 55024 Surge EN 61000-4-4 ±1 kV (L-N) ±2 kV (L-FG & N-FG) Environmental Parameter Conditions Min. Typ. Max. Units Operating Temperature Range Ambient -25 +25 +70 °C Storage Temperature Range -25 +85 °C Cooling Free Air Convection (See Derating Curve) Humidity RH, Non-condensing 95 % Physical Size See Mechanical Drawings (Pages 3 & 4) Weight U-Channel 13.47 Oz (0.382 kg) With Cover 14.10 Oz (0.400 kg) Reliability Specifi cations Parameter Conditions Min. Typ. Max. Units MTBF MIL HDBK 217F , 25°C, Gnd Benign 120 kHours Safety Standards UL 1950, EN 60950 (except 5 & 15 VOUT models) Vibration 10~500 Hz, 2G 10 min/1 Cycle. Period of 60 min each along X, Y &Z Axis
Page 2 • MPD 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com www.micropowerdirect.comModel Selection Guide For open frame models, see MPO-120S Datasheet Model Number Input Output Max Output Power (W) Voltage Adjust Range (VDC) Max Ripple & Noise (mV P-P) Max Capacitive Load (µF) Effi ciency (%, Typ) Current (A) Voltage (VDC) Current (A)
115 VAC 230 VAC W/0
CFM % Min. Load vs Input Voltage Notes: 1. PFC meets EN61000-3-2. 2. Ripple and noise is measured at 20 MHz bandwidth using a 0.1 µF and a 47 µF capacitor connected in parallel as close to the power supply terminals as possible. 3. Overload protection is provided by a “hiccup mode” circuit. The unit recovers automatically when the fault condition is removed. 4. These units will operate at no load without damage. However they may not meet all specifi cations. The recommended minimum load is given in the model selection chart above. 5. Each unit includes an input fuse. Since this fuse is not fi eld replaceable, it is recommended that an external fuse be used on the input of the power supply for protection. For these units, a 15A/250V slow blow fuse is recommended. Temperature Derating: MPU-120S-05 Temperature Derating: All Other Models Model Number Block Diagram
www.micropowerdirect.com MicroPower Direct • 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com Mechanical Dimensions: 5V Output Model Term. Function 4+ V OUT 5- V OUT Connections Input Connector (CN1):
- Barrier Strip Terminal Block: Anytek Connector: DG28S-B-03P: M3 Screws 3 terminals, 7.62 mm Centers Suitable Wire = 22 - 14 AWG Output Connectors:
- Two PCB Terminals (Wire Lugs): PCB-50 (M5 Screws) Suitable Wire = 22 - 14 AWG Term. Function
1 AC-Line
2 AC-Neutral
3 Field Grnd
Mechanical Dimensions: All Other Models Term. Function 4+ V OUT 5+ V OUT 6- V OUT 7- V OUT Connections Input Connector (CN1):
- Barrier Strip Terminal Block: Anytek Connector: DG28S-B-03P: M3 Screws 3 terminals, 7.62 mm Centers Suitable Wire = 22 - 14 AWG Term. Function
Output Connector (CN2):
- Barrier Strip Terminal Block: Anytek Connector: DG28S-B-04P: M3 Screws 4 terminals, 7.62 mm Centers Suitable Wire = 22 - 14 AWG Notes: All dimensions are typical in inches (mm)
- Tolerance x.xx = ±0.02 (±0.50) Notes: All dimensions are typical in inches (mm)
- Tolerance x.xx = ±0.02 (±0.50)
Page 4 • MPD 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com www.micropowerdirect.com Mechanical Dimensions: 5V Output “E” Model Term. Function 4+ V OUT 5- V OUT Connections Input Connector (CN1):
- Barrier Strip Terminal Block: Anytek Connector: DG28S-B-03P: M3 Screws 3 terminals, 7.62 mm Centers Suitable Wire = 22 - 14 AWG Output Connectors:
- Two PCB Terminals (Wire Lugs): PCB-50 (M5 Screws) Suitable Wire = 22 - 14 AWG Term. Function
Mechanical Dimensions: All Other “E” Models Term. Function 4+ V OUT 5+ V OUT 6- V OUT 7- V OUT Connections Input Connector (CN1):
- Barrier Strip Terminal Block: Anytek Connector: DG28S-B-03P: M3 Screws 3 terminals, 7.62 mm Centers Suitable Wire = 22 - 14 AWG Term. Function
Output Connector (CN2):
- Barrier Strip Terminal Block: Anytek Connector: DG28S-B-04P: M3 Screws 4 terminals, 7.62 mm Centers Suitable Wire = 22 - 14 AWG Notes: All dimensions are typical in inches (mm)
- Tolerance x.xx = ±0.02 (±0.50) Notes: All dimensions are typical in inches (mm)
- Tolerance x.xx = ±0.02 (±0.50)
www.micropowerdirect.com MicroPower Direct • 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com OPTIONAL CONNECTOR - “MOLEX” TYPE OPTIONAL CONNECTOR - Clamp TYPE Output Connector (CN 2):
- “Molex” type connector: Alex Connector: 8673W-080020 8 pins Mating Connector: 8639 type or equiv. Pin Function Pin Function 4+ V OUT 8- V OUT 5+ V OUT 9- V OUT 6+ V OUT 10 -V OUT 7+ V OUT 11 -V OUT Input Connector (CN 1):
- “Molex” type connector: Alex Connector: 8673W-050220 5 pins, 2 Removed Mating Connector: 8639 type or equiv. Pin Function
Output Connector (CN 2):
- Clamp type connector: Anytek Connector: TI04245 4 terminals, 7.5 mm Centers Suitable Wire = 22 - 14 AWG Term. Function 4+ V OUT 5+ V OUT 6- V OUT 7- V OUT Input Connector (CN 1):
- Clamp type connector: Anytek Connector: TI03245 3 terminals, 7.5 mm Centers Suitable Wire = 22 - 14 AWG Term. Function
www.micropowerdirect.com MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com OPTIONAL DIN Rail Mount: 5V Output Model OPTIONAL DIN Rail Mount: All Other Models A DIN Rail Mounting kit is available from MPD, for use with MPU-120”C” models. The kit contains a mounting clip and three screws. The clip is attached to the bottom of the unit using the three threaded holes marked “A” on the mechanical diagrams. Screws should not be inserted over 2 mm into the threaded inserts, To order the kit, ask for part no: MPU-120S-DRK DIN Rail Mounting Kit