DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

Parameter Conditions Min. Typ. Max. Units Input Voltage Range Universal 90 264 VAC 127 373 VDC Input Frequency 47 63 Hz Input Filter Meets EN 55022 Class B; FCC Class B Input Current See Model Selection Guide Inrush Current Cold Start, 115 VAC 29.0 A PkCold Start, 230 VAC 50.0 Safety Ground Leakage Current 264 VAC 3.5 mA Output Parameter Conditions Min. Typ. Max. Units Output Voltage/Current See Model Selection Guide Output Voltage Tolerance, See Note 1 Output 1, 3 ±3.0 %Output 2 ±4.0 Line Regulation, See Note 2 Output 1, 3 ±0.5 %Output 2 ±2.0 Load Regulation, See Note 3 Output 1 ±3.0 %Output 2 ±5.0 Output 3 ±1.0 Ripple & Noise (20 MHz), See Note 4 See Model Selection Guide Hold-Up Time 115 VAC 8 mSec230 VAC 20 Temperature Coeffi cient ±0.05 %/°C Short Circuit Protection Continuous (Autorecovery) Over Voltage Protection 130 % Overload Protection See Note 3 150 % General Parameter Conditions Min. Typ. Max. Units Isolation Voltage Input to Output 3,000 VAC Isolation Resistance 500 VDC 1,000 M/H9024 Isolation Capacitance 2,200 pF EMI/RFI Conducted EN 55022; EN 61000-3-2, -3 EMC Compliance Electrostatic Discharge (ESD) IEC/EN 61000-4-2, -6, -8, -11 RF Field Susceptibility IEC/EN 61000-4-3 Electrical Fast Transients/Bursts On Mains IEC/EN 61000-4-4 Surge IEC/EN 61000-4-5 Switching Frequency Fixed 66 kHz Environmental Parameter Conditions Min. Typ. Max. Units Operating Temperature Range Ambient 0 +25 +45 °C Storage Temperature Range -20 +85 °C Cooling Free Air Convection (See Derating Curve) Humidity RH, Non-condensing 93 % Physical Weight 5.99 Oz (0.170 kg) Reliability Specifi cations Parameter Conditions Min. Typ. Max. Units MTBF MIL HDBK 217F , 25°C, Gnd Benign 200 kHours Safety Standards UL 60950, EN 60950 Vibration Sinusoidal 50~500 Hz, 3.0 Grms, Period of 30 min each along X, Y & Z Axis Triple Output, 40W Compact, Open Frame AC/DC Power Supplies Key Features:

  • 40W Output Power
  • Triple Outputs
  • Universal 90-264 AC Input
  • EN 60950 Approved (UL)
  • Compact 2 x 4 In Package
  • Eight Standard Models
  • Meets EN 55022 B
  • >200 kHour MTBF MPO-40TSeries Electrical Specifi cations Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice. www.micropowerdirect.com MicroPower Direct

292 Page Street

Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com

Derating Curve (Models 01 thru 06) Notes: 1. Output voltage tolerance is measured at nominal input and 60% load. 2. Line regulation is measured at nom- inal load over a range of 100 to 240 VAC. 3. Load regulation is specifi ed for a load change of 60% ± 40% (of full load). 4. Output ripple is measured at 20 MHz bandwidth using 0.1 µF and 10 µ F capacitors connected in parallel as close to the power supply terminals as possible. 5. The maximum output current is given for each individual output. The maxi- mum output power rating for the unit should not be exceeded. By adding 30 CFM of airfl ow (see derating curves) all models may be used at higher power levels. Contact the factory for more information. 6. Each unit includes an input fuse (250V/2A). Since this fuse is not fi eld replaceable, it is recommended that an external fuse of the same size be used on the input of the power supply for protection. Notes:

  • All dimensions are typical in inches (mm)
  • Tolerance x.xx = ±0.02 (±0.50) MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com www.micropowerdirect.com Input Connector (CN1):
  • Molex 5273-03A or equivalent (one pin removed)
  • Mating Housing: Molex 5195-03 or equivalent
  • Mating Terminal: Molex 5293 or equivalent Pin Function

1 AC-Neutral

2 Removed

3 AC-Line

Safety Ground: The mounting holes marked “Use metal standoffs” should be connected to the system earth ground via metal spacers or a cable. The input side mounting hole marked “FG” provides the safety earth ground for the unit. This connection should be locked to prevent possible loosening. Connecting the output side mounting hole improves EMI. Output Connector (CN2):

  • Molex 5273-06A or equivalent
  • Mating Housing: Molex 5195-06 or equivalent
  • Mating Terminal: Molex 5293 or equivalent Pin Function 1V OUT 2 2V OUT 1 3V OUT 1

4 Common

5 Common

(W) Output Ripple & Noise (mV P-P) Max Output Cap. (µF) Effi ciency (%, Typ) Current (A) No. Voltage (VDC) Current (A) 115 VAC 230 VAC Rated Min. Max. MPO-40T-01 0.75 0.46 1 +5.0 3.0 0.4 5.0 40 ±1% 1,400 782 +12.0 2.0 0.2 2.5 3 -5.0 0.3 0.0 0.5 MPO-40T-02 0.75 0.46 1 +5.0 3.0 0.4 5.0 40 ±1% 1,400 782 +12.0 2.0 0.2 2.5 MPO-40T-03 0.75 0.46 1 +5.0 3.0 0.4 5.0 40 ±1% 1,400 782 +15.0 1.5 0.2 2.3 MPO-40T-04 0.75 0.46 1 +5.0 3.0 0.4 5.0 40 ±1% 1,400 782 +24.0 1.0 0.2 1.0 MPO-40T-05 0.75 0.45 1 +5.0 3.0 0.4 5.0 40 ±1% 1,400 782 +24.0 1.0 0.2 1.5 3 -5.0 0.3 0.0 0.5 MPO-40T-06 0.75 0.47 1 +5.0 3.0 0.4 5.0 40 ±1% 1,400 782 +24.0 1.0 0.2 1.5 MPO-40T-07 0.75 0.38 1 +3.3 5.0 0.4 7.0 ±3% Derating Curve (Model 07)