Parameter Conditions Min. Typ. Max. Units Input Voltage Range Universal 90 264 VAC 127 373 VDC Input Frequency 47 63 Hz Input Filter Meets EN 55022 Class B; FCC Class B Input Current See Model Selection Guide Inrush Current Cold Start, 115 VAC 36.0 A PkCold Start, 230 VAC 100.0 Safety Ground Leakage Current 264 VAC 3.5 mA Output Parameter Conditions Min. Typ. Max. Units Output Voltage/Current See Model Selection Guide Output Voltage Tolerance See Note 1 ±1.0 % Line Regulation Vin = Min to Max ±0.5 % Load Regulation Iout = 10% to 100% ±1.0 % Ripple & Noise (20 MHz) See Note 2 ±1.0 % Hold-Up Time See Note 3 10 mSec Temperature Coeffi cient ±0.05 %/°C Short Circuit Protection Continuous (Autorecovery) Over Voltage Protection See Note 3 130 % General Parameter Conditions Min. Typ. Max. Units Isolation Voltage Input to Output 3,000 VAC Isolation Resistance 500 VDC 1,000 M/H9024 Isolation Capacitance 5,845 pF EMI/RFI Conducted EN 55022; EN 61000-3-2, -3 EMC Compliance Electrostatic Discharge (ESD) IEC/EN 61000-4-2, -6, -8, -11 RF Field Susceptibility IEC/EN 61000-4-3 Electrical Fast Transients/Bursts On Mains IEC/EN 61000-4-4 Surge IEC/EN 61000-4-5 Switching Frequency Fixed 90 kHz Environmental Parameter Conditions Min. Typ. Max. Units Operating Temperature Range Ambient -20 +25 +80 °C Storage Temperature Range -20 +85 °C Cooling See Derating Curve Humidity RH, Non-condensing 93 % Physical Weight 14.10 Oz (0.400 kg) Reliability Specifi cations Parameter Conditions Min. Typ. Max. Units MTBF MIL HDBK 217F , 25°C, Gnd Benign 110 kHours Safety Standards UL 60950, EN 60950 Vibration Sinusoidal 50~500 Hz, 3.0 Grms, Period of 30 min each along X, Y & Z Axis Single Output, 200W Miniature, Open Frame AC/DC Power Supplies Key Features:

  • 200W Output Power
  • PFC to EN 61000-3-2,3 “D”
  • Universal 90-264 AC Input
  • EN 60950 Approved (UL)
  • Miniature 3 x 5 In Package
  • Meets EN 55022 B
  • Effi ciency To 92%
  • >110 kHour MTBF MPO-200SSeries Electrical Specifi cations Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice. www.micropowerdirect.com MicroPower Direct

292 Page Street

Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com

Input Connector (CN1):

  • TKP PVH1-3N2 or equivalent (one pin removed)
  • Mating Housing: JST VHR-3N or equivalent
  • Mating Terminal: SVH-21T-PH1 or equivalent Pin Function

1 AC-Line

2 Removed

3 AC-Neutral

Safety Ground: The unit should be mounted using metal standoffs. The input side mounting hole marked “FG” provides the safety earth ground for the unit. This point should be connected to the system earth ground via a metal spacer or a cable. This connection should be locked to prevent possible loosening. Connecting the output side mounting holes to earth ground improves EMI (this connection will also put the rear heatsink at ground potential). Output Connector (CN2):

  • TKP PVH1-08 or equivalent
  • Mating Housing: JST-VHR-8N or equivalent
  • Mating Terminal: SVH-21T-PH1 or equivalent Pin Function Pin Function 1+ V OUT 5- V OUT 2+ V OUT 6- V OUT 3+ V OUT 7- V OUT 4+ V OUT 8- V OUT Fan Drive Connector (CN3):
  • LCU P205DG-02 or equivalent
  • Mating Housing: Molex 5051-02 or equivalent
  • Mating Terminal: Molex 5159 or equivalent Pin Function 1 +Fan Out 2 -Fan Out T he fan drive provides 12VDC @ 300 mA. Remote Sense Connector (CN4):
  • LCU P205DG-02 or equivalent
  • Mating Housing: Molex 5051-02 or equivalent
  • Mating Terminal: Molex 5159 or equivalent Pin Function 1 +Rs 2 -Rs The remote sense outputs may be used to compensate for up to a 0.5V line drop. Connections Derating CurveNotes: 1. Output voltage tolerance is measured at nominal input and 60% load. 2. Output ripple is measured at 20 MHz bandwidth using 0.1 µF and 10 µF capacitors connected in parallel as close to the power supply terminals as possible. 3. Hold-up time is typical for 115 VAC and 230 VAC inputs. 4. These units will operate at no load without damage. For most applications however, MPD recommends that a minimum load always be used. Contact the factory for more information. 5. The remote sense outputs may be used to com- pensate for up to a 0.5V line drop. 6. The fan drive provides 12VDC @ 300 mA. 7. Each unit includes an input fuse (250V/5A). Since this fuse is not fi eld replaceable, it is recom- mended that an external fuse of the same size be used on the input of the power supply for protection. Notes:
  • All dimensions are typical in inches (mm)
  • Tolerance x.xx = ±0.02 (±0.50) MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com www.micropowerdirect.com Model Number Input Output Output Power (Max. W) Max Output Capacitance (µF) Effi ciency (%, Typ) Current (A) Voltage (VDC) Current (A) With 19 CFM Convection115 VAC 230 VAC Maximum (With 19 CFM) Maximum (Convection) % Min.