292 Page Street
Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com Input Parameter Conditions Min. Typ. Max. Units Input Voltage Range Universal 90 264 VAC 127 370 VDC Input Frequency 47 63 Hz Input Current See Model Selection Guide Inrush Current Cold Start, 115 VAC 20.0 A PkCold Start, 230 VAC 40.0 Safety Ground Leakage Current 115 VAC 0.35 mA240 VAC 0.5 Output Parameter Conditions Min. Typ. Max. Units Output Voltage See Model Selection Guide Output Current See Model Selection Guide Output Voltage Adjustment See Model Selection Guide Output Voltage Tolerance, See Note 1 See Model Selection Guide Ripple & Noise (20 MHz), See Note 2 See Model Selection Guide Hold-Up Time 115 VAC 15 mSec230 VAC 60 Set-Up Time 230 VAC 800 mSec Rise Time 230 VAC 20 mSec Temperature Coeffi cient ±0.02 %/°C Short Circuit Protection Continuous (Autorecovery) Over Voltage Protection See Note 3 115 135 % Overload Protection See Note 4 112 160 % General Parameter Conditions Min. Typ. Max. Units Isolation Voltage Input to Output 3,000 VACInput to Ground 1,500 Output to Ground 500 Isolation resistance 500 VDC 100 MΩ EMI/RFI Conducted EN 55022; EN 61000-3-2, -3 EMC Compliance Electrostatic Discharge (ESD) IEC/EN 61000-4-2, -6, -8, -11 RF Field Susceptibility IEC/EN61000-4-3 Electrical Fast Transients/Bursts On Mains IEC/EN 61000-4-4 Surge IEC/EN 61000-4-5 Switching Frequency Fixed 65 kHz Environmental Parameter Conditions Min. Typ. Max. Units Operating Temperature Range Ambient -10 +25 +60 °C Storage Temperature Range -20 +85 °C Cooling Free Air Convection (See Derating Curve) Humidity RH, Non-condensing 95 % Physical Weight 7.4 Oz (0.21 kg) Reliability Specifi cations Parameter Conditions Min. Typ. Max. Units MTBF MIL HDBK 217F, 25°C, Gnd Benign 300 kHours Safety Standards IEN 60950, IEC 60950 Vibration 10~500 Hz, 2G 10 min/1 Cycle. Period of 60 min each along X, Y &Z Axis Single Output, 65W Compact, Open Frame AC/DC Power Supplies Key Features:
- 65W Output Power
- Universal 90-264 AC Input
- EN 60950 Compliant
- Low Leakage Current
- Nine Single Output Models
- Meets EN55022
- >300 kHour MTBF
- Only 5” x 3” x 1.6” Si l O 6 MPO-65S Series RoHS Compliant Electrical Specifi cations Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice.
Pin Connections: CN2 (Molex 5273-06 or equiv.) Pin Connections: CN1 (Molex 5277-02 or equiv.) Model Selection Guide Mechanical Dimensions Pin Function Mating Housing Terminal
1 AC-Neutral Molex 5195
or Equiv. Molex 5194 or Equiv.2 AC-Line MicroPower Direct www.micropowerdirect.com 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com Model Number Input Output Output Tolerance (%) Ripple & Noise (mV p-p) Effi ciency (%, Typ) Current (A) Voltage (VDC) Current (A)
115 VAC 230 VAC Rated Adjust Rated Range
Output Derating vs Input Voltage Notes: 1. Output voltage tolerance includes the the effects of set point accuracy, line regulation and load regulation. 2. Ripple and noise is measured at 20 MHz bandwidth using a 12 inch twisted pair wire to connect to the power supply terminals. A 0.1 µF and a 47 µF capacitor are connected in parallel as close to the power supply terminals as possible. 3. Overvoltage protection is provided by a “hiccup mode” circuit. The unit recovers automatically when the fault condition is removed. 4. Overload protection is provided by a “hiccup mode” circuit. The unit recovers automatically when the fault condition is removed. For the 3.3V output model, overload protection is set to operate between 36 to 55W. 5. Mounting holes M1 and M2 should be grounded for EMI purposes. 6. It is recommended that a fuse be used on the input of a power supply for protection. See the mechanical diagram for the correct rating. Pin Function Mating Housing Terminal 1, 2, 3 +Vout Molex 5195 or Equiv. Molex 5194 or Equiv.4, 5, 6 -Vout Notes:
- All dimensions are typical in inches (mm)
- Tolerance x.xx = ±0.01 (±0.25)