DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
Parameter Conditions Min. Typ. Max. Units Input Voltage Range 85 265 VAC Input Frequency 47 440 Hz Input Current See Model Selection Guide Inrush Current 115 VAC 20.0 A Pk230 VAC 40.0 EMI Meets CISPR Pub. 22/FCC Class B Output Parameter Conditions Min. Typ. Max. Units Output Voltage See Model Selection Guide Output Current See Model Selection Guide Output Voltage Accuracy, Note 1 ±1.0 ±2.0 % Line Regulation V IN = Min to Max ±0.2 ±1.0 % Load Regulation, Single Output IO = Min to Max ±0.5 ±1.0 % Load Regulation, Dual Output IO = Min to Max ±2.5 ±5.0 % Load Regulation, Triple Output - Primary IO = Min to Max ±2.5 ±5.0 % Load Regulation, Triple Output - Aux. IO = Min to Max ±4.0 % Ripple & Noise (20 MHz) 3.3 & 5.0 VDC Output 1.5 1.8 %VP-P of VO All Other Outputs 1.0 1.3 Hold-Up Time 115 VAC, 60 Hz 20 mSec Temperature Coeffi cient ±0.02 %/°C Over Voltage Protection Zener Diode Clamp 120 % of VO Short Circuit Protection, Note 4 Continuous (Autorecovery) Overload Protection, Note 5 Typ. 120% to 180% of Output Power General Parameter Conditions Min. Typ. Max. Units Isolation Voltage Input to Output 3,000 VAC Isolation Test Voltage Input to Output, Flash Tested For 60S 4,700 VAC Isolation Resistance 500 VDC 100 M EMI/RFI Conducted EN 55022 Level B EMC Compliance Electrostatic Discharge (ESD) EN 61000-4-2 Level B RF Field Susceptibility EN 61000-4-3 Electrical Fast Transients/Bursts On Mains EN 61000-4-4 Level 3 2 kV Surge EN 61000-4-5 Level 3 1kV/2 kV Switching Frequency 100 kHz Environmental Parameter Conditions Min. Typ. Max. Units Operating Temperature Range Ambient -25 +25 +71 °C Storage Temperature Range -40 +85 °C Cooling Free Air Convection (See Derating Curve) Humidity RH, Non-condensing 95 % Physical Case Material Non-Conductive Plastic& Fiberglass (UL94-V0) Weight 6.72 Oz (191g) Reliability Specifi cations Parameter Conditions Min. Typ. Max. Units MTBF MIL HDBK 217F , 25°C, Gnd Benign 250 kHours Safety Standards UL 60950, EN 60950 Safety Approvals UL, cUL; File No. E245422 Safety Class IEC 61140 Class II Chassis Mount, 30W Single, Dual & Triple Out AC/DC Power Supplies MPM-30CMSeries Electrical Specifi cations Specifi cations typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice.Key Features:
- 30W Output Power
- Universal 85-265 VAC Input
- EN 60950 Approved (UL)
- Single, Dual & Triple Outputs
- Meets EN 55022 B
- Meets IEC Safety Class II
- Chassis Mount Case MicroPower Direct
292 Page Street
Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com www.micropowerdirect.com PCB Mount Models & DIN Rail Mount Option Available!
Mechanical Dimensions, Chassis Mount Notes:
- All dimensions are typical in inches (mm)
- Tolerance x.xx = ±0.01 (±0.25) Pin Single Dual Triple
1 AC-Neutral
2 AC-Line
7 NC -Vo +Vo 3
NC = No Connection Pin Connections Model Number Input Output 1 (Vout 1) Output 2 (Vout 2) Output 3 (Vout 3) Capacitive Load (µF, Max) Effi - ciency (%, Typ) Current (A) Voltage (VDC) Current (A) Voltage (VDC) Current (A) Voltage (VDC) Current (A) Derating Curve Notes: 1. For triple output models, the output voltage accuracy of the auxilliary outputs is typically ±4%. 2. Load regulation is measured for an output change of 0% to 100% at nominal input line. For multiple output models, the loads are balanced. 3. Operation at no-load will not damage these units. However, they may not meet all specifi cations. 4. Output short circuit protection is provided by a “hiccup mode” circuit. The unit recovers automati- cally when the fault condition is removed. 5. Output overload protection is provided by a fold back current limiting circuit. 6. For triple output models, the maximum capacitive load for 5 VDC and 3.3VDC outputs is 2,200 µF. For all other outputs it is ±1,500 µF. 7. The MPM-30CM series includes a built-in 3.5A/250 VAC fuse. It is recommended that an external 1.5A slow blow fuse also be used on the input for protection. Other output combinations are available Contact the factory for details at: sales@micropowerdirect.com A DIN Rail mounting kit is available Contact the factory for details at: sales@micropowerdirect.com www.micropowerdirect.com MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com Model Number