DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

Parameter Conditions Min. Typ. Max. Units Input Voltage Range 90 305 VAC 120 430 VDC Input Frequency 47 440 Hz Input Current See Model Selection Guide Inrush Current 115 VAC 25.0 A Pk230 VAC 45.0 Leakage Current 0.25 mA EMI Meets CISPR Pub. 22/FCC Class B EMC Meets EN 55024 Output Parameter Conditions Min. Typ. Max. Units Output Voltage See Model Selection Guide Output Current See Model Selection Guide Output Voltage Accuracy See Note 1 ±2.0 % Line Regulation, See Note 2 V IN = Min to Max ±0.2 % Load Regulation, See Note 3 See Model Selection Guide Ripple (20 MHz), See Note 4 3.3, 5, 9 12, 15 Vout Models 100 mV P - P24 Vout Models 150 Dual Output Models 100 Noise 3.3, 5, 9 12, 15 Vout Models 150 mV P - P24 Vout Models 200 Dual Output Models 150 Hold-Up Time 115 VAC 10 mSec230 VAC 75 Temperature Coeffi cient ±0.02 %/°C Over Voltage Protection Zener Diode Clamp 120 % of VO Short Circuit Protection, See Note 5 Continuous (Autorecovery) Overload Protection 115 150 % of I O General Parameter Conditions Min. Typ. Max. Units Isolation Voltage Input to Output 3,000 VAC Isolation Resistance 500 VDC 100 M/H9024 EMI/RFI Conducted EN 55022 Level B EMC Compliance Electrostatic Discharge (ESD) EN 61000-4-2 Level B RF Field Susceptibility EN 61000-4-3 Electrical Fast Transients/Bursts On Mains EN 61000-4-4 Level 3 2 kV Surge EN 61000-4-5 Level 3 1kV/2 kV Switching Frequency 132 kHz Environmental Parameter Conditions Min. Typ. Max. Units Operating Temperature Range, Ambient 5.0/3.3 Vout Model -25 +25 +70 °CAll Other Models -40 +25 +70 Storage Temperature Range -40 +125 °C Cooling Free Air Convection (See Derating Curves) Humidity RH, Non-condensing 95 % Physical Case Material Non-Conductive Plastic & Fiberglass (UL94-V0) Weight 1.58 Oz (45g) Reliability Specifi cations Parameter Conditions Min. Typ. Max. Units MTBF MIL HDBK 217F , 25°C, Gnd Benign 350 kHours Vibration 10~55 Hz, 20G 1 min/1 Cycle. Period of 3 min each along X, Y &Z Axis Safety Approvals UL, cUL; File No. E245422 Safety Class IEC 61140 Class II Single & Dual Output, 8W Miniature “Power Brick” AC/DC Power Supplies MPM-08MBSeries Electrical Specifi cations Specifi cations typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice. Key Features:

  • 8W Output Power
  • Miniature Case
  • Wide 90-305 VAC Input
  • EN 60950 Approved (UL)
  • Meets IEC Safety Class II
  • Meets EN 55022 B
  • Eight Standard Models
  • >350 kHour MTBF MicroPower Direct

292 Page Street

Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com www.micropowerdirect.com

(% Max) Maximum Capacitive Load (µF) Maximum Output Power (W) Effi ciency (%, Typ)Current (A) Voltage (VDC) Current 115 VAC 230 VAC Max. (A) Min. (%) Mechanical Dimensions MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com www.micropowerdirect.com Notes: 1. The output voltage accuracy of the V 2 output (pin 5) on dual outputs is ±15% for the MPM-08D- 0503MB, and ±10% for the MPM-08D-1205MB. 2. The line regulation of the dual output models is ±2.0% for the V 1 output (pin 4), and ±3% for the V2 output (pin 5). 3. Load regulation is measured from 10% load to 100% load. 4. Ripple and noise are measured at 20 Mhz bandwidth with a 0.1 µF and a 47 µ F capacitor con- nected in parallel as close to the unit output terminals as possible. 5. Output short circuit protection is provided by a “hiccup mode” circuit. The unit recovers automatically when the fault condition is removed. 6. Operation under no load conditions will not damage single output units. For dual output units, minimum load requirements are given in the table above. 7. It is recommended that a fuse be used on the input of a power supply for protection. For the MPM-08MB series, a 2A/250 VAC slow blow should be used. Notes:

  • All dimensions are typical in inches (mm)
  • Tolerance x.xx = ±0.01 (±0.25) Pin Single Dual

1 AC-Line

2 AC-Neutral

5 NC Vout 2

NC = No Connection Pin Connections Derating Curve - Single Output Models Derating Curve - Dual Output Models