www.micropowerdirect.com MicroPower Direct
292 Page Street
Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com Input Parameter Conditions Min. Typ. Max. Units Input Voltage Range 85 305 VAC 100 430 VDC Input Frequency 47 63 Hz Input Current See Model Selection Guide Inrush Current 115 VAC 10.0 A Pk230 VAC 15.0 Leakage Current 230 VAC/50 Hz 0.3 mA rms Output Parameter Conditions Min. Typ. Max. Units Output Voltage See Model Selection Guide Output Current See Model Selection Guide Minimum Load 0 % Output Voltage Accuracy ±2.0 % Line Regulation VIN = Min to Max ±0.5 % Load Regulation See Note 2 ±1.0 % Ripple & Noise (20 MHz) See Note 3 50 100 mV Pk - Pk Hold-Up Time 115 VAC 15 mSec230 VAC 80 Temperature Coeffi cient ±0.02 %/°C Short Circuit Protection Continuous (Autorecovery) Overload Protection Autorecovery 110 % General Parameter Conditions Min. Typ. Max. Units Isolation Voltage Input to Output, 60S 3,000 VACInput to FG, 60S 2,000 Switching Frequency 100 kHz Environmental Parameter Conditions Min. Typ. Max. Units Operating Temperature Range Ambient -40 +25 +70 °C Storage Temperature Range -40 +105 °C Cooling Free Air Convection (See Derating Curve) Humidity RH, Non-condensing 95 % Physical Case Size See Mechanical Diagram On Page 4 Case Material Non-Conductive Black Plastic (UL94-V0) Weight 2.64 Oz (75g) Reliability Specifi cations Parameter Conditions Min. Typ. Max. Units MTBF MIL HDBK 217F , 25°C, Gnd Benign 300 kHours Lead Temperature, See Note 4 Wave Solder 260 °CHand Solder 360 Safety Standards UL 60950, EN 60950 Safety Class Class I 85 to 305 VAC Input, 10W Miniature PC Mount AC/DC Power Supplies Key Features:
- 10W Output Power
- Universal 85-305 VAC Input
- EN 60950 Approved
- Six Single Output Models
- Meets EN 55022 B
- >300 kHour MTBF
- Compact PC Mount Case MPM-10SVSeries Electrical Specifi cations Specifi cations typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice.
292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com www.micropowerdirect.com Model Selection Guide Model Number Input Output Over Volt. Protection (VDC) Capacitive Load (µF , Max) Effi ciency (%, Typ)Current (A) Voltage (VDC) Current (A Max.) Power (W)115 VAC 230 VAC Derating Curve Typical Connection 1. It is recommended that an external fuse and NTC be used. The recommended fuse is a 1.0A/300 VAC slow blow. 2. All units are rated for EN 55022 (CE/RE) class B without external components. 3. All units are rated for EN 61000-4-4 ( ±2 kV) with the addition of the MOV shown in the typical connection above. They will meet EN 61000-4-4 (±4 kV) with the additional input components shown in the typical connection diagram shown on page 3. 4. All units are rated for EN 61000-4-5 (±1 kV/±2 kV) with the addi- tion of the MOV shown in the typical connection above. They will Notes: 1. Operation at no load will not damage the units, however, they may not meet all specifi cations. 2. Load regulation is measured for an output change of 10% to 100% at nominal input line. 3. When measuring output ripple, it is recommended that an external 0.1 µF high frequency ceramic capacitor be placed in parallel with a 47 µF high frequency electrolytic capacitor from the +V OUT pin to the -VOUT pin. 4. The max lead temp for wave soldering is ±5% for a time period of 5 to 10S. For hand soldering, it is ±10% for 3 to 5S. Input Voltage Vs Load The diagram above illustrates a typical application connection of the MPM-10SV series. Notes on this circuit (starting with the input circuit) are: MPD offers a wide variety of input protection and fi ltering modules for use with our AC & DC power modules. The MACFM-02A may be used with the MPM-10SV, as shown on page. Full data- sheets for all our input modules are available on our website, or call the factory for a more help. 5. All units are rated for EN 55022 (CE/RE) class B without external components. 6. All units are rated for EN 61000-4-4 (±2 kV) with the addi- tion of the MOV shown in the typical connection below. They will meet EN 61000-4-4 (±4 kV) with the additional input components shown in the typical connection diagram shown on page 3. 7. All units are rated for EN 61000-4-5 (±1 kV/±2 kV) with the addi- tion of the MOV shown in the typical connection below. They will meet EN 61000-4-5 (±2 kV /±4 kV) with the input components shown in the typical connection diagram on page 3. 8. It is recommended that a fuse be used on the input of a power supply for protection. For the MPM-10SV-xx series, a 2.0A/300 VAC slow blow should be used. meet EN 61000-4-5 (±2 kV /±4 kV) with the input components shown in the typical connection diagram on page 3. 5. If output noise levels lower than the specifi ed limits are required, the addition of C 1 and C2 should be suffi cient for most applications. The recommended values are shown in the table at right. The output fi ltering capacitor C2 is a high frequency, low resistance electrolytic capacitor. Capacitor C1 is ceramic. Voltage derating of capacitors should be 80% or above. 6. The TVS is added to protect circuits being powered from damage if the module fails. Model C1 C 2 TVS MPM-10SV-03 1.0 µ F/50V 470 µ F/10V SMBJ7.0A MPM-10SV-05 1.0 µ F/50V 330 µ F/10V SMBJ7.0A MPM-10SV-09 1.0 µ F/50V 120 µ F/25V SMBJ12A MPM-10SV-12 1.0 µ F/50V 120 µ F/25V SMBJ20A MPM-10SV-15 1.0 µ F/50V 120 µ F/25V SMBJ20A MPM-10SV-24 1.0 µ F/50V 68 µ F/35V SMBJ30A
MicroPower Direct • 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com www.micropowerdirect.com Typical Connection: With Input Protection/Filtering Components The diagram above illustrates a typical connection of the MPM-10SV series. The input components are required to meet the more stringent EFT/Surge levels of EN 61000-4 (see notes for EMC Characteristics table above). Some notes on these components are: 1. It is recommended that an external fuse be used. The recommended fuse size is a 2.0A/300 VAC slow blow. 2. An external MOV is recommended on the input to protect the unit in the event of a surge. A recommended value is given in the table at right. 3. The output fi ltering capacitors (C 1 & C2) will reduce the output noise below specifi ed levels. Recommended values are given in the table on page 2. 4. The TVS is added to protect circuits being powered from damage if the module fails. A recommended value for each model is given in the table on page 2. Notes: 1. To meet the requirements of EN 61000- 4-4 (±4 kV), external components are needed. This can be done discretely (as shown below), or with the addition of the MACFM-02A. Contact the factory for more information. 2. To meet the requirements of EN 61000-4-5 (±2 kV/ ±4 kV ), external components are needed. This can be done discretely (as shown below), or with the addition of the MACFM-02A. Contact the factory for more information. Typical Board Layout: With External Filter Module 5. Suggested component values are: Component MPM10SV-03 MPM10SV-05 MPM10SV-09 MPM10SV-12 MPM10SV-15 MPM10SV-24 MOV S14K350 S14K350 S14K350 S14K350 S14K350 S14K350 LCM 10 mH 10 mH 10 mH 10 mH 10 mH 10 mH CY1/CY2 1,000 pF/400VAC 1,000 pF/400VAC 1,000 pF/400VAC 1,000 pF/400VAC 1,000 pF/400VAC 1,000 pF/400VAC 6. Input protection and fi ltering modules are available for a number of MPD AC/DC power supplies. For use with the MPM-10SV product series, the MACFM-02A fi lter module is recommended. A typical connection diagram and board layout with this module is shown in the fi gures below. For pricing or full technical information on the MACFM-02A (or any of our other modules) please contact the factory. Typical Board Layout: With External Filter Module Parameter Conditions Criteria Level Radiated Emissions EN 55022 Class B Conducted Emissions EN 55022 Class B ESD EN 61000-4-2 B ±8 kV Air ±6 kV Contact RS EN 61000-4-3 A 10V/m EFT EN 61000-4-4 B ±2 kV See Note 1 B ±4 kV Surge EN 61000-4-5 B ±1 kV/±2 kV See Note 2 B ±2 kV/±4 kV CS EN 61000-4-6 A 10V rms PFM EN 61000-4-8 A 10A/m Voltage Dips, Short, Interruptions EN 61000-4-11 B 0% - 70% EMI Characteristics 1. The width of circuit traces should be a minimum of 3 mm. 2. The distance between traces should be a minimum of 6 mm. 3. The distance between a trace and ground should be a minimum of 6 mm.
We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com www.micropowerdirect.com Notes:
- All dimensions are typical in inches (mm)
- Tolerance x.xx = ±0.02 (±0.50) Mechanical Dimensions Pin Function
1 AC-Ground
2 AC-Neutral
3 AC-Line
The MPM-10SV family is part of a series of products that range from 5W to 25W. The chart at left gives a summary of the other models in this series. Full data on all products is available on the MPD website. Contact the factory for more information. Other Power Ranges Series Input Output Voltage Output Current Module Dimensions MPM-05SV 85 - 305 VAC 3.3 VDC 1.250A 2.16 x 1.77 x 0.83 (55.0 x 45.0 x 21.0) 5.0 VDC 1.000A 9.0 VDC 0.550A 12.0 VDC 0.420A 15.0 VDC 0.330A 24.0 VDC 0.230A MPM-15SV 85 - 305 VAC 3.3 VDC 3.000A 2.44 x 1.77 x 0.88 (62.0 x 45.0 x 22.5) 5.0 VDC 2.800A 9.0 VDC 1.600A 12.0 VDC 1.250A 15.0 VDC 1.000A 24.0 VDC 0.625A 48.0 VDC 0.320A MPM-20SV 85 - 305 VAC 3.3 VDC 3.500A 2.75 x 1.88 x 0.92 (70.0 x 48.0 x 23.5) 5.0 VDC 3.500A 9.0 VDC 2.100A 12.0 VDC 1.600A 15.0 VDC 1.300A 24.0 VDC 0.850A MPM-25SV 85 - 305 VAC 3.3 VDC 4.100A 2.75 x 1.88 x 0.92 (70.0 x 48.0 x 23.5) 5.0 VDC 4.100A 9.0 VDC 2.500A 12.0 VDC 2.100A 15.0 VDC 1.600A 24.0 VDC 1.100A 48.0 VDC 0.500A