DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

Parameter Conditions Min. Typ. Max. Units Input Voltage Range 85 264 VAC 120 370 VDC Input Frequency 47 63 Hz Input Current See Model Selection Guide Inrush Current 115 VAC 10.0 A Pk230 VAC 20.0 EMI Meets CISPR Pub. 22/FCC Class B Safety Ground Leakage Current 115 VAC 0.1 mA230 VAC 0.3 Output Parameter Conditions Min. Typ. Max. Units Output Voltage See Model Selection Guide Output Current See Model Selection Guide Output Voltage Accuracy ±2.0 % Line Regulation ±0.5 Load Regulation, See Note 1 See Model Selection Guide Ripple & Noise (20 MHz) 50 mV Pk - Pk Hold-Up Time 115 VAC 20 mSec230 VAC 80 Temperature Coeffi cient ±0.02 %/°C Short Circuit Protection Continuous (Autorecovery) Overload Protection Typ. 110% of Output Power General Parameter Conditions Min. Typ. Max. Units Isolation Voltage Input to Output 3,000 VACInput to Ground 1,500 Output to Ground 500 EMI/RFI Conducted EN 55022 Level B EMC Compliance Electrostatic Discharge (ESD) EN 61000-4-2 Level 3 6kV/8kV RF Field Susceptibility EN61000-4-3 Electrical Fast Transients/Bursts On Mains EN 61000-4-4 Level 3 2 kV Surge EN 61000-4-5 Level 3 1kV/2 kV Switching Frequency 150 kHz Environmental Parameter Conditions Min. Typ. Max. Units Operating Temperature Range Ambient -25 +25 +70 °C Case +90 °C Storage Temperature Range -25 +105 °C Cooling Free Air Convection (See Derating Curve) Humidity RH, Non-condensing 85 % Physical Case Material Non-Conductive Black Plastic (UL94-V0) Weight 4.23 Oz (120g) Reliability Specifi cations Parameter Conditions Min. Typ. Max. Units MTBF MIL HDBK 217F , 25°C, Gnd Benign 200 kHours Safety Standards UL 60950, EN 60950 Safety Approvals UL, cUL; File No. E245422 Compact, 10W PC Mount Single, Dual & Dual ISO Out AC/DC Power Supplies Key Features:

  • 10W Output Power
  • Universal 85-264 VAC Input
  • EN 60950 Approved (UL)
  • Single, Dual & Dual Iso Outputs
  • Meets EN 55022 B
  • >200 kHour MTBF
  • Compact PC Mount Case MPM-10Series Electrical Specifi cations Specifi cations typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice. MicroPower Direct

292 Page Street

Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com www.micropowerdirect.com

Input Output 1 (Vout 1) Output 2 (Vout 2) Output 3 (Vout 3) Effi ciency (%, Typ) Current (A) Voltage (VDC) Current (A) Over Volt. Protection (VDC) Voltage (VDC) Current (A) Over Volt. Protection (VDC) Voltage (VDC) Current (A)

115 VAC 230 VAC Rated Load

Reg. Rated Load Reg. Rated Load Reg. Typical Connection Mechanical Dimensions Notes:

  • All dimensions are typical in inches (mm)
  • Tolerance x.xx = ±0.01 (±0.25) Pin Single Dual Dual ISO

1 AC-Ground AC-Ground AC-Ground

2 AC-Neutral AC-Neutral AC-Neutral

3 AC-Line AC-Line AC-Line

5 No Pin No Pin +Vo 1

6 No Pin Common No Pin

7 No Pin No Pin -Vo 2

Notes: 1. Load regulation is measured for an output change of 10% to 90% at nominal input line. For multiple output models, the loads are balanced. 2. The MPM-10 series is specifi ed for operation over the wide oper- ating temperature range of -25°C to +55°C without derating. For operation over +55°C, derate the power linearly by 3.75%/°C from +55°C to +70°C. 3. Model numbers MPM-10ID-05xx are dual isolated units (Dual ISO). The outputs on these models are isolated from each other. 4. It is recommended that a fuse be used on the input of a power supply for protection. For the MPM-10 series, a 2A/250 VAC slow blow should be used. Vout C1, C3 C2, C4 Fuse TVS 3.3 330 ~ 1,000 µ F/16V 0.1 µF/50V Ceramic 2A/

250 VAC

P6KE6.8A 5.0 330 ~ 1,000 µ F/16V P6KE6.8A 12.0 220 µ F/25V P6KE16A 15.0 220 µ F/25V P6KE20A 24.0 120 µ F/35V P6KE33A Typical Component Values Notes: 1. C1 and C3 are high frequency, low resistance electrolytic capacitors. Refer to the suppliers specifi cations for capacitance/current ratings. 2. Voltage derating on all capacitors should be 80% or higher. 3. C2 and C4 eliminate high frequency noise. 4. The TVS is recommended to protect load circuitry in the event of a module failure. MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com www.micropowerdirect.com