www.micropowerdirect.com MicroPower Direct

292 Page Street

Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com Miniature 1 x 1 Inch 5W, Single Output AC/DC Power Supplies Key Features:  5W Output Power  Miniature 1 x 1 Inch Case  Universal 85-264 VAC Input  EN 60950 Approved  Chassis Mount Option  Meets EN 55022 B  Meets IEC Safety Class II  >1.20 MHour MTBF MPM-05MMSeries Electrical Specifi cations Specifi cations typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice. www.micropowerdirect.comwww.micropowerdirect.com Input Parameter Conditions Min. Typ. Max. Units Input Voltage Range 85 264 VAC 120 370 VDC Input Frequency 47 440 Hz Input Current See Model Selection Guide Inrush Current, See Note 1 115 VAC 20.0 A Pk230 VAC 40.0 No Load Power Consumption See Note 2 300 mW Output Parameter Conditions Min. Typ. Max. Units Output Voltage See Model Selection Guide Output Current See Model Selection Guide Output Voltage Accuracy ±2.0 % Line Regulation VIN = Min to Max ±1.0 % Load Regulation I OUT = 0% to 100% ±1.0 % Ripple & Noise, See Note 3 3.3 & 5 VDC Out Models 60 m V P-P All Other Models 1.0 % V P-P of VOUT Hold-Up Time 115 VAC 8.0 mS230 VAC 40 Temperature Coeffi cient ±0.05 %/°C Over Voltage Protection See Note 4 125 190 %V OUT Overshoot 5.0 %V OUT Short Circuit Protection, See Note 5 Continuous (Autorecovery) Overload Protection See Note 6 135 150 %W General Parameter Conditions Min. Typ. Max. Units Isolation Voltage Input to Output 3,000 VAC Isolation Resistance 500 VDC 100 M Switching Frequency 65 kHz EMI Characteristics Parameter Standard Criteria Level Radiated Emissions EN 55014, EN 55024 Class B Conducted Emissions EN 55022 Class B ESD EN 61000-4-2 A ±8 kV Air/±4 kV Contact RS EN 61000-4-3 A 10V/m EFT EN 61000-4-4 A ±2 kV Surge EN 61000-4-5 A ±1 kV CS EN 61000-4-6 A 10 Vrms PFM EN 61000-4-8 A 30A/m Voltage Dips EN 61000-4-11 A 30% 10 mS Interruptions EN 61000-4-11 B 95% 500 mS Environmental Parameter Conditions Min. Typ. Max. Units Operating Temperature Range Ambient -25 +25 +70 °C Storage Temperature Range -40 +85 °C Cooling Free Air Convection (See Derating Curve) Humidity RH, Non-condensing 95 % Physical Case Size See Mechanical Diagram (Page 2) Case Material Non-Conductive Black Plastic (UL94-V0) Weight Board Mount 0.69 Oz (19.7g) Chassis Mount 0.85 Oz (19.7g) Reliability Specifi cations Parameter Conditions Min. Typ. Max. Units MTBF MIL HDBK 217F , 25°C, Gnd Benign 1.20 MHours Safety Standards EN 60950 Safety Class IEC 60536 Class II

www.micropowerdirect.com MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com Model Selection Guide Mechanical Dimensions Notes:

  • All dimensions are typical in inches (mm)
  • Tolerance x.xx = ±0.02 (±0.25) Pin Function

1 AC-Neutral

2 AC-Line

3 No Connection

Notes: 1. Inrush current is given for a cold start at 25°C. 2. No load power consumption meets the standby power consumption limits in the European ERP Directive 2009/125/EC. 3. Ripple & Noise is specifi ed over a range of 0 - 20 MHz. It is measured with a 1 µF/50V MLCC connected from +V OUT to -VOUT. 4. Over voltage protection is provided by a zener diode clamp. 5. Output short circuit protection is provided by a “hiccup mode” circuit. The unit recovers automatically when the fault condition is removed. 6. Output overload protection is provided by a fold back current limiting circuit with auto-recovery. A long-term overload could damage the unit. 7. Operation at no-load will not damage these units. However, they may not meet all specifi cations. 8. Peak load is specifi ed as lasting <30s with a maximum duty cycle of 10% The average power should not exceed the maximum power rating. 9. It is recommended that an external slow blow fuse also be used on the input for protection. See the table above for the correct rating. Model Number Input Current (mA Typ) Output Effi ciency (%, Typ) Capacitive Load (µF Max) Fuse Rating Slow-Blow (mA) Voltage (VDC) Current (mA) 115 VAC Max. Min. Peak MPM-05S-03MM (C) 117 3.3 1,515 0.0 1,970 74 2,200 1,000 MPM-05S-05MM (C) 108 5.0 1,000 0.0 1,300 80 1,000 1,000 MPM-05S-09MM (C) 106 9.0 555 0.0 721 82 300 1,000 MPM-05S-12MM (C) 106 12.0 416 0.0 540 82 160 1,000 MPM-05S-15MM (C) 104 15.0 333 0.0 433 83 100 1,000 MPM-05S-24MM (C) 104 24.0 208 0.0 270 83 43 1,000 MPM-05S-48MM (C) 102 48.0 104 0.0 135 85 10 1,000 Derating Curve Other outputs may be available Contact the factory for details at: sales@micropowerdirect.com Chassis MountBoard Mount To order a chassis mount version, add a “C” to the model number (i.e. MPM-05S-15MMC)