MPM-05 MPD | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

292 Page Street

Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com Input Parameter Conditions Min. Typ. Max. Units Input Voltage Range 85 264 VAC 120 370 VDC Input Frequency 47 63 Hz Input Current See Model Selection Guide Inrush Current 115 VAC 10.0 A Pk230 VAC 20.0 EMI Meets CISPR Pub. 22/FCC Class B Safety Ground Leakage Current 115 VAC 0.1 mA230 VAC 0.3 Output Parameter Conditions Min. Typ. Max. Units Output Voltage See Model Selection Guide Output Current See Model Selection Guide Output Voltage Accuracy ±2.0 % Line Regulation ±0.5 Load Regulation See Model Selection Guide Ripple & Noise (20 MHz) 50 mV Pk - Pk Hold-Up Time 115 VAC 20 mSec230 VAC 80 Temperature Coeffi cient ±0.02 %/°C Short Circuit Protection Continuous (Autorecovery) Overload Protection Typ. 110% of Output Power General Parameter Conditions Min. Typ. Max. Units Isolation Voltage Input to Output 3,000 VACInput to Ground 1,500 Output to Ground 500 EMI/RFI Conducted EN 55022 Level B EMC Compliance Electrostatic Discharge (ESD) IEC/EN 61000-4-2 Level 3 RF Field Susceptibility IEC/EN61000-4-3 Electrical Fast Transients/Bursts On Mains IEC/EN 61000-4-4 Level 3 2 kV Surge IEC/EN 61000-4-5 Level 3 1kV/2 kV Switching Frequency 150 kHz Environmental Parameter Conditions Min. Typ. Max. Units Operating Temperature Range Ambient -20 +25 +70 °C Case +90 °C Storage Temperature Range -25 +105 °C Cooling Free Air Convection (See Derating Curve) Humidity RH, Non-condensing 85 % Physical Case Material Non-Conductive Black Plastic (UL94-V0) Weight 3.77 Oz (107g) Reliability Specifi cations Parameter Conditions Min. Typ. Max. Units MTBF MIL HDBK 217F, 25°C, Gnd Benign 200 kHours Safety Standards IEN 60950, IEC 60950 Safety Approvals, See Note 3 IEN 60950, IEC 60950 Compact, 5W PC Mount Single, Dual & Triple Out AC/DC Power Supplies Key Features:

  • 5W Output Power
  • Universal 85-264 VAC Input
  • EN 60950 Approved
  • Single, Dual & Triple Outputs
  • Meets EN55022 B
  • >200 kHour MTBF
  • Compact PC Mount Case MPM-05Series Electrical Specifi cations Specifi cations typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice.

Notes:

  • All dimensions are typical in inches (mm)
  • Tolerance x.xx = ±0.01 (±0.25) Pin Single Dual Triple

1 AC-Ground AC-Ground AC-Ground

2 AC-Neutral AC-Neutral AC-Neutral

3 AC-Line AC-Line AC-Line

5 No Pin No Pin +Vo 1

6 No Pin Common -Vo 2

7 No Pin No Pin Common

www.micropowerdirect.com 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com Notes: 1. Load regulation is measured for an output change of 10% to 90% at nominal input line. For multiple output models, the loads are balanced. 2. The MPM-05 series is specifi ed for operation over the wide operating temperature range of -20°C to +55°C without derating. For operation over +55°C, derate the power linearly by 3.75%/°C from +55°C to +70°C. 3. Single output models are approved to EN60950. Approval for other models is pending. 4. It is recommended that a fuse be used on the input of a power supply for protection. For the MPM-05 series, a 1A/250 VAC slow blow should be used. Model Number Input Output 1 (Vout 1) Output 2 (Vout 2) Output 3 (Vout 3) Effi ciency (%, Typ) Current (A) Voltage (VDC) Current (A) Over Volt. Protection (VDC) Voltage (VDC) Current (A) Over Volt. Protection (VDC) Voltage (VDC) Current (A) 115 VAC 230 VAC Typ. Load Reg. Typ. Load Reg. Typ. Load Reg. Typical Connection Vout C1, C3, C5 C2, C4, C6 Fuse TVS 3.3 330 ~ 1,000 µF/16V 0.1 µF/50V Ceramic 1A/

250 VAC

P6KE6.8A 5.0 330 ~ 1,000 µF/16V P6KE6.8A 12.0 220 µF/25V P6KE16A 15.0 220 µF/25V P6KE20A 24.0 120 µF/35V P6KE33A Typical Component Values Notes: 1. C1, C3 and C5 are high frequency, low resistance electrolytic capacitors. Refer to the suppliers specifi cations for capacitance/current ratings. 2. Voltage derating on all capacitors should be 80% or higher. 3. C2, C4 and C6 eliminate high frequency noise. 4. The TVS is recommended to protect load circuitry in the event of a module failure.