DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

Parameter Conditions Min. Typ. Max. Units Input Voltage Range 85 264 VAC 100 400 VDC Input Frequency 47 63 Hz Input Current 115 VAC 0.15 A230 VAC 0.20 Inrush Current 115 VAC 20.0 A Pk230 VAC 30.0 Leakage Current 5.0 mA Output Parameter Conditions Min. Typ. Max. Units Output Voltage See Model Selection Guide Output Current See Model Selection Guide Output Voltage Accuracy See Model Selection Guide Line Regulation VIN = Min to Max ±0.5 % Load Regulation IOUT = 10% to 100% ±1.5 % Ripple & Noise (20 MHz) 3.3V, 24V Models 50 150 mV P-P All Other Models 50 120 Hold-Up Time 115 VAC 20 mSec230 VAC 80 Temperature Coeffi cient ±0.15 %/°C Short Circuit Protection Continuous (Autorecovery) General Parameter Conditions Min. Typ. Max. Units Isolation Voltage Input to Output 3,000 VAC Switching Frequency 100 kHz EMI Characteristics Parameter Standard Min. Typ. Max. Units Radiated Emissions See Note 2 EN 55022 Class A Conducted Emissions See Note 2 EN 55022 Class A ESD EN 61000-4-2 Criteria B; ±4 kV Contact RS EN 61000-4-3 Criteria A; 10V/m EFT See Note 3 EN 61000-4-4 Criteria B; ±2 kV Surge See Note 4 EN 61000-4-5 Criteria B; ±2 kV /±4 kV CS EN 61000-4-6 Criteria A; 3 Vrms PFMF EN 61000-4-8 Criteria A; 10A/m Voltage Dips EN 61000-4-11 Criteria B; 0% - 70% Environmental Parameter Conditions Min. Typ. Max. Units Operating Temperature Range Ambient -25 +25 +85 °C Operating Temperature Range Case +100 °C Storage Temperature Range -40 +105 °C Cooling Free Air Convection (See Derating Curve) Humidity RH, Non-condensing 85 % Physical Case Material Non-Conductive Epoxy (UL94-V0) Weight 0.35 Oz (10g) Reliability Specifi cations Parameter Conditions Min. Typ. Max. Units MTBF MIL HDBK 217F , 25°C, Gnd Benign 300 kHours Safety Standards EN 60950 Safety Class IEC 61140 Class II Single Output, 5W Ultra-Miniature SIP AC/DC Power Supplies Key Features:

  • 5W Output Power
  • Universal 85-264 VAC Input
  • EN 60950 Approved (UL)
  • Meets IEC Safety Class II
  • Single Regulated Output
  • Meets EN 55022 Class A
  • >300 kHour MTBF
  • Ultra-Miniature “SIP” Case MPL-05SESeries Electrical Specifi cations Specifi cations typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice. MicroPower Direct

292 Page Street

Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com www.micropowerdirect.com

Notes:

  • All dimensions are typical in inches (mm)
  • Tolerance x.xx = ±0.02 (±0.50) Pin Function Pin Function

1 AC-Neutral 7 -V CAP

3 AC-Line 12 -V OUT

(%) Max Capacitive Load (µF) Effi ciency (%, Typ)Voltage (VDC) Current (mA Max.) MPL-05S-03E 3.3 1,000 ±2.0 1,000 65 MPL-05S-05E 5.0 1,000 ±1.0 1,500 70 MPL-05S-09E 9.0 560 ±1.0 630 72 MPL-05S-12E 12.0 420 ±1.0 470 74 MPL-05S-15E 15.0 340 ±1.0 330 75 MPL-05S-24E 24.0 210 ±1.0 100 75 Derating Curve Mechanical Dimensions MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com www.micropowerdirect.com Typical Connection 1. It is recommended that an external fuse and NTC be used. The recommended fuse is a 1.0A/250V slow blow and for the NTC, a 5D-9. 2. An external MOV is recommended on the input to protect the unit in the event of a surge. A 561KD14 or equivalent is recommended. 3. The fi lter capacitor C1 is required for specifi ed operation. The recommended value is 33 µF/400V. 4. The safety capacitors (Cx1 and CY0) provide EMI/RFI suppresion. Recommended values are 0.22 µF/275 VAC (Cx1) and 1 nF/400 VAC (CY0). 5. Recommended values for other components are: Output C2 L1 C3 C4 TVS 3.3V 470 µF/16V 0.47 µ H 150 µ F/35V 100 nF/50V SMBJ7.0A 5.0V 470 µF/16V 0.47 µ H 150 µ F/35V 100 nF/50V SMBJ7.0A 9.0V 330 µF/35V 1.0 µH 150 µ F/35V 100 nF/50V SMBJ12A 12V 330 µF/35V 1.0 µ H 150 µ F/35V 100 nF/50V SMBJ20A 15V 330 µF/35V 1.0 µ H 150 µ F/35V 100 nF/50V SMBJ20A 24V 100 µF/35V 4.7 µ H 47 µ F/35V 100 nF/50V SMBJ30A The output fi ltering capacitors (C2,C3) are high frequency, low resistance electro- lytic capacitors. Capacitor (C4) is ceramic. Voltage derating of capacitors should be 80% or above. 6. Input noise and surge suppression modules are available for a number of MPD AC/DC power supplies. An MPL-05SE connection with the ACFM-01 is illustrated in the diagram at left. For pricing or full technical information on these modules (ACFM-01 and ACFM-02) please contact the factory. Notes: 1. Operation at no load will not damage the units, however, they may not meet all specifi cations. 2. All units are rated for EN 55022 (CE/RE) class A with the addition of external components such as the typical circuit shown below. They will meet class B with the addition of the ACFM-01 (or a similar discrete fi lter circuit). Contact the factory for more information. 3. To meet the requirements of EN 61000-4-4 (±4 kV), external components are needed. This can be done discretely, or with the addition of the ACFM-01. Contact the factory for more information. 4. To meet the requirements of EN 61000-4-5 (±4 kV/±4 kV), external components are needed. This can be done discretely, or with the addition of the ACFM-01. Contact the factory for more information. 5. It is recommended that a fuse be used on the input of a power supply for protection. For the MPL-05SE series, a 1.0A/250 VAC slow blow should be used. Input Voltage Vs Load The diagram below illustrates a typical application connection of the MPL-05SE series. Notes on this circuit (starting with the input circuit) are: Typical Board Layout: With ACFM-01 Input Module (See note 6)