MPG-100 MPD | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

Parameter Conditions Min. Typ. Max. Units Input Voltage Range Universal 85 264 VAC 110 373 VDC Input Frequency 47 63 Hz Input Filter Meets EN 55022 Class B; FCC Class B Input Current See Model Selection Guide Inrush Current Cold Start, 115 VAC 30.0 A PkCold Start, 230 VAC 60.0 Power Factor Correction Meets EN 61000-3-2/3 Class A Leakage Current 0.25 mA No Load Power Consumption 0.5 W Output Parameter Conditions Min. Typ. Max. Units Output Voltage/Current See Model Selection Guide Output Voltage Tolerance See Note 1 ±1.0 % Line Regulation See Note 2 ±1.0 % Load Regulation See Note 3 ±1.0 % Ripple & Noise (20 MHz) See Note 4 ±1.0 % Hold-Up Time 230 VAC 40 mSec Temperature Coeffi cient ±0.05 %/°C Over Voltage Protection 140 % Short Circuit Protection Continuous (Autorecovery) General Parameter Conditions Min. Typ. Max. Units Isolation Voltage Input to Output 3,000 VAC Isolation Resistance 500 VDC 100 M/H9024 Isolation Capacitance 2,200 pF EMI Characteristics Parameter Standard Min. Typ. Max. Units Radiated Emissions, See Note 5 EN 55022 Class B Conducted Emissions , See Note 5 EN 55022 Class B ESD EN 61000-4-2 Criteria A; ±8 kV Air/±6 kV Contact RS EN 61000-4-3 Criteria A; 10V/m EFT EN 61000-4-4 Criteria A; ±2 kV Line & PE Surge EN 61000-4-5 Criteria A; L-N: ±1kV, L/N-PE: ±2kV CS EN 61000-4-6 Criteria A; 10 Vrms PFMF EN 61000-4-8 Criteria A; 10 Vrms Voltage Dips, See Note 6 EN 61000-4-11 Criteria A; Volt. Dips >95%, 0.5 Cycle Criteria A; Volt. Dips 30%, 25 Cycles Criteria A/B; Volt. Dips 60%, 5 Cycles Criteria C; Volt. Inter, >95%, 250 Cycles Switching Frequency Fixed 65 kHz Environmental Parameter Conditions Min. Typ. Max. Units Operating Temperature Range Ambient -20 +25 +70 °C Storage Temperature Range -40 +85 °C Cooling Free Air Convection (See Derating Curve) Humidity RH, Non-condensing 95 % Physical Weight 6.34 Oz (0.180 kg) Reliability Specifi cations Parameter Conditions Min. Typ. Max. Units MTBF MIL HDBK 217F , 25°C, Gnd Benign 400 kHours Safety Standards UL 60950, EN 60950 Single Output, 100W Green, Open Frame AC/DC Power Supplies Key Features:

  • 100W Output Power
  • 115W With Only 7 CFM
  • Universal 85-264 AC Input
  • EN 60950 Approved (UL)
  • Meets ErP Directive
  • Compact 2 x 4 Inch Size
  • PFC Meets EN 61000-3
  • Optional +5V SB Output
  • >400 kHour MTBF MPG-100SSeries Electrical Specifi cations Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice. www.micropowerdirect.com MicroPower Direct

292 Page Street

Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com

Derating CurveNotes: 1. Output voltage tolerance is measured at 110 VAC input and 60% load. 2. Line regulation is measured at a 115 VAC input with the rated load. The line is varied ±10%. 3. Load regulation is specifi ed for a load change of 60% ± 40% (of full load). 4. Output ripple is measured at 20 MHz bandwidth and rated load using 0.1 µF and 10 µF capacitors connected in parallel as close to the power supply terminals as possible. 5. To meet the EMI limits, the mounting holes must be connected together (by using metal standoffs). 6. The unit meets EN 61000-4-11 criteria A for voltage dips of 60% at 100 VAC input. At 240 VAC input, it meets criteria B. 7. These units will operate at no load without damage. However, they may not meet all specifi cations. 8. The optional remote on/off function is active low. Contact the factory for details. 9. Each unit includes an input fuse (250V/3.15A). Since this fuse is not fi eld replaceable, it is recommended that an external fuse of the same size be used on the input of the power supply for protection. Notes:

  • All dimensions are typical in inches (mm)
  • Tolerance x.xx = ±0.02 (±0.50) MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com www.micropowerdirect.com Model Number Input Output Max Output Power (W) Effi ciency (%, Typ) Current (A) No. Voltage (VDC) Current (A) 115 VAC 230 VAC Rated Max. (W/7 CFM) Min. Convection Cooled With 7CFM Air Flow Input Connector (CN1):
  • Molex 09-65-2038 or equivalent (one pin removed)
  • Mating Housing: Molex 09-50-1031 or equivalent Pin Function

1 AC-Neutral

2 Removed

3 AC-Line

Safety Ground: The mounting holes marked “Use metal standoffs” should be connected to the system earth ground via metal spacers or a cable. The input side mounting hole marked “FG” provides the safety earth ground for the unit. This connection should be locked to prevent possible loosening. Connecting the output side mounting hole improves EMI. Output Connector (CN2):

  • Molex 09-65-2048 or equivalent
  • Mating Housing: Molex 09-50-1041 or equivalent Pin Function 1+ V OUT 2+ V OUT 3- V OUT 4- V OUT Connector (CN3):
  • Molex 5045-03A or equivalent
  • Mating Housing: Molex 5043-03 or equivalent Pin Function

1 Remote On/Off

Connector CN3 is only installed on “SB” models Connections