Parameter Conditions Min. Typ. Max. Units Input Voltage Range Switch Selectable 88 115 132 VAC176 220 264 248 370 VDC Input Frequency 47 63 Hz Input Current See Model Selection Guide Inrush Current Cold Start, 115 VAC 20.0 A PkCold Start, 230 VAC 40.0 Safety Ground Leakage Current 115 VAC 2.0 mA230 VAC 3.5 Output Parameter Conditions Min. Typ. Max. Units Output Voltage See Model Selection Guide Output Current See Model Selection Guide Output Voltage Adjustment See Model Selection Guide Output Voltage Tolerance, See Note 1 See Model Selection Guide Ripple & Noise (20 MHz), See Note 2 See Model Selection Guide Hold-Up Time 115 VAC 20 mSec230 VAC 24 Set-Up Time 230 VAC 2,000 mSec Rise Time 230 VAC 20 mSec Temperature Coeffi cient ±0.02 %/°C Short Circuit Protection Continuous (Autorecovery) Over Voltage Protection See Note 3 115 135 % Overload Protection See Note 4 105 135 % Fan Control (Over Temp Control) Fan On, 5V - 15 Vout RT1 >65 °C Fan On, 24V - 48 Vout RT1 >70 °C Fan Off, 5V - 15 Vout RT1 <55 °C Fan Off, 24V - 48 Vout RT1 <65 °C Output Shutdown, 5V - 15Vout RT1 >70 °C Output Shutdown, 24V - 48Vout RT1 >80 °C General Parameter Conditions Min. Typ. Max. Units Isolation Voltage Input to Output 3,000 VACInput to Ground 1,500 Output to Ground 500 Isolation resistance 500 VDC 100 MΩ EMI/RFI Conducted EN 55022; EN 61000-3-2, -3 EMC Compliance Electrostatic Discharge (ESD) IEC/EN 61000-4-2, -6, -8, -11 RF Field Susceptibility IEC/EN61000-4-3 Electrical Fast Transients/Bursts On Mains IEC/EN 61000-4-4 Surge IEC/EN 61000-4-5 Switching Frequency 75 kHz Environmental Parameter Conditions Min. Typ. Max. Units Operating Temperature Range Ambient -10 +25 +60 °C Storage Temperature Range -20 +85 °C Cooling Internal Fan With Built In Control Humidity RH, Non-condensing 95 % Physical Case Material Vented Metal Enclosure Weight 38.1 Oz (1.08 kg) Reliability Specifi cations Parameter Conditions Min. Typ. Max. Units MTBF MIL HDBK 217F, 25°C, Gnd Benign 188 kHours Safety Standards IEN 60950, IEC 60950 Vibration 10~500 Hz, 2G 10 min/1 Cycle. Period of 60 min each along X, Y &Z Axis MicroPower Direct

292 Page Street

Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com Single Output, 320W Compact, Enclosed AC/DC Power Supplies Key Features:

  • 320W Output Power
  • Selectable 88-264 AC Input
  • EN 60950 Approved
  • Internal Fan With Control
  • Eight Single Output Models
  • Meets EN55022
  • >188 kHour MTBF
  • Compact Metal Enclosure Si l O 320 MPE-320SSeries RoHS Compliant Electrical Specifi cations Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice.

Notes:

  • All dimensions are typical in inches (mm)
  • Tolerance x.xx = ±0.01 (±0.25) Pin Function

1 AC-Line

2 AC-Neutral

3 AC-Ground

www.micropowerdirect.com 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com Model Number Input Output Output Tolerance (%) Ripple & Noise (mV p-p) Effi ciency (%, Typ) Current (A) Voltage (VDC) Current (A)

115 VAC 230 VAC Rated Adjust Rated Range

Notes: 1. Output voltage tolerance includes the the effects of set point accuracy, line regula- tion and load regulation. 2. Ripple and noise is measured at 20 MHz bandwidth using a 12 inch twisted pair wire to connect to the power supply terminals. A 0.1 µF and a 47 µF capacitor are connected in parallel as close to the power supply terminals as possible. 3. Overvoltage protection is provided by a “hiccup mode” circuit. The unit recovers automatically when the fault condition is removed. 4. Overload protection is provided by fold- back current limiting. The unit recovers automatically when the fault condition is removed. 5. It is recommended that a fuse be used on the input of a power supply for protec- tion. For the MPE-320S series, a 10A/250 VAC slow blow should be used.