MN08 CHAUVINARNOUX | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 16
Technical content
Serie MN Pinces ampèremetriques pour courant AC Non-contractual document 906131102B - Ed 1 2.00 (1/2) MN seriesCurrent clamps for AC current MN SERIES These ergonomic mini-clamps are designed to make light work of measuring low and medium currents from 0.01 A to 240 A AC. The shape of the jaws makes ‘hooking’ onto cables easy, even in areas of restrictive access. The jaws can grip conductors up to 20/uni00A0mm in diameter. Depending on the particular model, they have one or two calibres. The output is via either jack sockets or a lead with 4/uni00A0mm Ø/uni00A0plugs, hence these clamps are compatible with all multimeters and testers on the market. There are two types of MN series clamps available. The fi rst kind operates as a current transformer (ratio 1,000/1) and gives a current output (mA) for use with any tester with current calibres. The second type gives a voltage output (DC or AC depending on the model) proportional to the measured current (1, 10, 100 or 1,000/uni00A0mV/A). This voltage output means that, even with testers without any current calibres, it is possible to measure currents by means of the DC or AC voltage calibres. There are specifi c models in the MN series that have been designed with particular applications in mind such as measurement on current transformer outputs, on oscilloscopes and even of leakage currents.
Serie MN Pinces ampèremetriques pour courant AC Non-contractual document 906131102B - Ed 1 2.00 (2/2) MN seriesCurrent clamps for AC current 18.5 mm 34.5 mm 135 mm 57 mm 21 mm 65mm
Serie MN Pinces ampèremetriques pour courant AC Non-contractual document 906131102B - Ed 1 2.01 (1/1) MN seriesCurrent clamps for AC current Models MN08 and MN09 ELECTRICAL SPECIFICATIONS
- Current range: 0.5 A AC .. 240 A AC
- Current transformation ratio:
- Output signal: 1 mA/uni00A0AC / A AC (240 mA for 240 A)
- Accuracy and phase shift (1): Phase shift not specified ≤/uni00A05 ° ≤/uni00A03° ≤/uni00A02.5 °
- Bandwidth: 40 Hz .. 10 kHz
- Crest factor: 3 for a current of 200 A RMS
- Maximum currents:
200 A continuous for a frequency ≤/uni00A0 3 kHz
(limitation proportional to the inverse of one third of frequency beyond)
- Load impedance: ≤/uni00A010 /uni03A9
- Operating voltage: 600/uni00A0VRMS
- Common mode voltage: 600/uni00A0V category/uni00A0III and pollution degree 2
- Infl uence of adjacent conductor: ≤/uni00A015 mA / A at 50 Hz
- Infl uence of conductor position in jaws: ≤/uni00A00.5/uni00A0% of output signal at 50/60 Hz
- Load infl uence: 0.2 .. 10 Ω </uni00A00.5/uni00A0% on measurement </uni00A00.5 ° on phase
- Infl uence of frequency (2): </uni00A03/uni00A0% of output signal from 40/uni00A0Hz .. 1/uni00A0kHz </uni00A012/uni00A0% of output signal from 1 kHz .. 10 kHz
- Infl uence of crest factor: </uni00A04/uni00A0% of output signal for a crest factor of 3 and current 200 of A RMS MECHANICAL SPECIFICATIONS
- Operating temperature: -10 °C to +55 °C
- Storage temperature: -40 °C to +70 °C
- Infl uence of temperature: ≤/uni00A00.15/uni00A0% of output signal per 10 °K
- Relative humidity for operation: 0 to 85/uni00A0% RH decreasing linearly above 35/uni00A0°C
- Infl uence of relative humidity: </uni00A00.2/uni00A0% of output signal from 10/uni00A0% to 85/uni00A0% RH
- Operating altitude: 0 to 2,000 m
- Max. jaw opening: 20/uni00A0mm
- Clamping capacity: Cable: Ø max 20/uni00A0mm Busbar: 1 busbar of 20 x 5/uni00A0mm
- Casing protection rating: IP40 (IEC/uni00A0529)
- Drop test: 1/uni00A0m (IEC/uni00A068-2-32)
- Shock resistance: 100 g (IEC/uni00A068-2-27)
- Vibration resistance: 10 / 55/10 Hz, 0.15/uni00A0mm (IEC/uni00A068-2-6)
- Self-extinguishing capability: Casing: UL94 V2 Jaws: UL94 V0
- Dimensions: 135 x 51 x 30/uni00A0mm
- Weight: 180 g
- Colours: Dark grey case with red jaws
- Output: MN08: Safety sockets (4/uni00A0mm) MN09: 1.5 m two-wire lead with double or reinforced insulation terminated by 2 elbowed male safety plugs (4/uni00A0mm) SAFETY SPECIFICATIONS
- Electrical safety: Instrument with double insulation or reinforced insulation between the primary, the secondary and the grippable part located under the guard as per IEC/uni00A01010-1 & IEC/uni00A01010-2-032. - 600/uni00A0V category/uni00A0III, pollution degree 2 - 300/uni00A0V category IV, pollution degree 2
- Electromagnetic compatibility (EMC): EN/uni00A050081-1: class B EN/uni00A050082-2: - Electrostatic discharge: IEC/uni00A01000-4-2 - Radiated field: IEC/uni00A01000-4-3 - Fast transients: IEC/uni00A01000-4-4 - Magnetic field at 50/60/uni00A0Hz: IEC/uni00A01000-4-8 (1) Conditions of reference: 23 °C ± 3 °K, 20 to 70 % RH, sinusoidal signal with frequency of 48/uni00A0Hz to 65/uni00A0Hz, external magnetic fi eld </uni00A040/uni00A0A/m, no DC components, no external conductor with circulating current, conductor centred for measurement, 1 Ω load. (2) Out of reference domain. Current 200 A/uni00A0AC Ratio 1000 / 1 Output 1 mA / A To order Reference AC current clamp model MN08 with operating manual P01120401 AC current clamp model MN09 with operating manual P01120402
906131102B - Ed 1 2.02 (1/1) MN series (1) Conditions of reference: 23 °C ± 3 °K, 20 to 70 % RH, sinusoidal signal with frequency of 48/uni00A0Hz to 65/uni00A0Hz, external magnetic fi eld </uni00A040/uni00A0A/m, no DC components, no external conductor with circulating current, conductor centred for measurement, 1 Ω load. (2) Out of reference domain.
- Bandwidth: 40 Hz .. 10 kHz
- Crest factor: 3 for a current of 200 ARMS
- Maximum currents:
(limitation proportional to the inverse of one third of frequency beyond)
- Load impedance: ≤/uni00A010 /uni03A9
- Maximum output voltage (secondary open): Limited to 8 V peak max.
- Operating voltage: 600/uni00A0VRMS
- Common mode voltage: 600/uni00A0V category/uni00A0III and pollution degree 2
- Infl uence of adjacent conductor: ≤/uni00A015 mA / A at 50 Hz
- Infl uence of conductor position in jaws: ≤/uni00A00.5/uni00A0% of output signal at 50/60 Hz
- Load infl uence: 0.2 .. 10 Ω </uni00A00.5/uni00A0% on measurement </uni00A00.5 ° on phase
- Infl uence of frequency (2): </uni00A03/uni00A0% of output signal from 40 Hz .. 1 kHz </uni00A012/uni00A0% of output signal from 1/uni00A0kHz .. 10 kHz
- Infl uence of crest factor: </uni00A04/uni00A0% of output signal for a crest factor of 3 and current of 200 A RMS MECHANICAL SPECIFICATIONS
- Operating temperature: -10/uni00A0°C to +55 °C
- Storage temperature: -40/uni00A0°C to +70 °C
- Infl uence of temperature: ≤/uni00A00.15/uni00A0% of output signal per 10 °K
- Relative humidity for operation: 0 to 85/uni00A0% RH decreasing linearly above 35/uni00A0°C
- Infl uence of relative humidity: </uni00A00.2/uni00A0% of output signal from 10/uni00A0% to 85/uni00A0% RH
- Operating altitude: 0 to 2,000 m
- Max. jaw opening: 20/uni00A0mm
- Clamping capacity: Cable: Ø max 20/uni00A0mm Busbar: 1 busbar of 20 x 5/uni00A0mm
- Casing protection rating: IP40 (IEC/uni00A0529)
- Drop test: 1 m (IEC/uni00A068-2-32)
- Shock resistance: 100 g (IEC/uni00A068-2-27)
- Vibration resistance: 10 / 55/10 Hz, 0.15/uni00A0mm (IEC/uni00A068-2-6)
- Self-extinguishing capability: Casing: UL94 V2 Jaws: UL94 V0
- Dimensions: 135 x 51 x 30/uni00A0mm
- Weight: 180 g
- Colours: Dark grey case with red jaws
- Output: MN10: Safety sockets (4/uni00A0mm) MN11: 1.5 m two-wire lead with double or reinforced insulation terminated by 2 elbowed male safety plugs (4/uni00A0mm) SAFETY SPECIFICATIONS
- Electrical safety: Instrument with double insulation or reinforced insulation between the primary, the secondary and the grippable part located under the guard as per IEC/uni00A01010-1 & IEC/uni00A01010-2-032 - 600/uni00A0V category/uni00A0III, pollution degree 2 - 300/uni00A0V category IV, pollution degree 2
- Electromagnetic compatibility (EMC): EN/uni00A050081-1: class B EN/uni00A050082-2: - Electrostatic discharge: IEC/uni00A01000-4-2 - Radiated field: IEC/uni00A01000-4-3 - Fast transients: IEC/uni00A01000-4-4 - Magnetic field at 50/60 Hz: IEC/uni00A01000-4-8
DESCRIPTION
An electronic voltage-limiting system protects output of clamp when operating, if the secondary circuit is opened. ELECTRICAL SPECIFICATIONS
- Current range: 0.5 A AC .. 240 A AC
- Current transformation ratio:
- Output signal: 1 mA/uni00A0AC / A AC (240 mA for 240 A)
- Accuracy and phase shift (1): Phase shift not specified ≤/uni00A05° ≤/uni00A03° ≤/uni00A02.5° ≤/uni00A02.5° ≤/uni00A02.5° Current 200 A/uni00A0AC Ratio 1000 / 1 Output 1 mA / A To order Reference AC current clamp model MN10 with operating manual P01120403 AC current clamp model MN11 with operating manual P01120404 Current clamps for AC current Models MN10 and MN11
906131102B - Ed 1 2.03 (1/1) MN series ELECTRICAL SPECIFICATIONS
- Current range: 0.5 A AC .. 240 A AC
- Output signal: 10 mV AC / A AC (2.4 V for 240 A)
- Accuracy and phase shift (1): % Accuracy of output signal ≤/uni00A03.5/uni00A0% + 5 mV ≤/uni00A02.5/uni00A0% + 5 mV ≤/uni00A02/uni00A0% + 5 mV ≤/uni00A01/uni00A0% + 5 mV Phase shift not specified ≤/uni00A05 ° ≤/uni00A03° ≤/uni00A02.5 °
- Bandwidth: 40 Hz .. 10 kHz
- Crest factor: 3 for a current of 200 ARMS
- Maximum currents:
200 A continuous for a frequency ≤/uni00A01 kHz (derating
proportional to the inverse of frequency beyond)
- Load impedance: > 1 M/uni03A9
- Operating voltage: 600/uni00A0VRMS
- Common mode voltage: 600/uni00A0V category/uni00A0III and pollution degree 2
- Infl uence of adjacent conductor: ≤/uni00A015 mA / A at 50 Hz
- Infl uence of conductor position in jaws: ≤/uni00A00.5/uni00A0% of output signal at 50/60 Hz
- Infl uence of frequency (2): </uni00A03/uni00A0% of output signal from 40/uni00A0Hz .. 1/uni00A0kHz </uni00A012/uni00A0% of output signal from 1/uni00A0kHz .. 10/uni00A0kHz
- Infl uence of crest factor: </uni00A03/uni00A0% of output signal for a crest factor of 3 and current of 200 A RMS MECHANICAL SPECIFICATIONS
- Operating temperature: -10/uni00A0°C to +55 °C
- Storage temperature: -40/uni00A0°C to +70 °C
- Infl uence of temperature: ≤/uni00A00.15/uni00A0% of output signal per 10 °K
- Relative humidity for operation : 0 to 85/uni00A0% RH decreasing linearly above 35/uni00A0°C
- Infl uence of relative humidity: </uni00A00.2/uni00A0% of output signal from 10/uni00A0% to 85/uni00A0% RH
- Operating altitude: 0 to 2,000 m
- Max. jaw opening: 20/uni00A0mm
- Clamping capacity: Cable: Ø max 20/uni00A0mm Busbar: 1 busbar of 20 x 5/uni00A0mm
- Casing protection rating: IP40 (IEC/uni00A0529)
- Drop test: 1 m (IEC/uni00A068-2-32)
- Shock resistance: 100 g (IEC/uni00A068-2-27)
- Vibration resistance: 10 / 55/10 Hz, 0.15/uni00A0mm (IEC/uni00A068-2-6)
- Self-extinguishing capability: Casing: UL94 V2 Jaws: UL94 V0
- Dimensions: 135 x 51 x 30/uni00A0mm
- Weight: 180 g
- Colours: Dark grey case with red jaws
- Output: MN12: Safety sockets (4/uni00A0mm) MN13: 1.5 m two-wire lead with double or reinforced insulation terminated by 2 elbowed male safety plugs (4/uni00A0mm) SAFETY SPECIFICATIONS
- Electrical safety: Instrument with double insulation or reinforced insulation between the primary, the secondary and the grippable part located under the guard as per IEC/uni00A01010-1 & IEC/uni00A01010-2-032 - 600/uni00A0V category/uni00A0III, pollution degree 2 - 300/uni00A0V category IV, pollution degree 2
- Electromagnetic compatibility (EMC): EN/uni00A050081-1: class B EN/uni00A050082-2: - Electrostatic discharge: IEC/uni00A01000-4-2 - Radiated field: IEC/uni00A01000-4-3 - Fast transients: IEC/uni00A01000-4-4 - Magnetic field at 50/60 Hz: IEC/uni00A01000-4-8 (1) Conditions of reference: 23 °C ± 3 °K, 20 to 70 % RH, sinusoidal signal with frequency of 48/uni00A0Hz to 65/uni00A0Hz, external magnetic fi eld </uni00A040/uni00A0A/m, no DC components, no external conductor with circulating current, conductor centred for measurement, load impedance > 1 MΩ. (2) Out of reference domain Current 200 A/uni00A0AC Output 10 mV / A To order Reference AC current clamp model MN12 with operating manual P01120405 AC current clamp model MN13 with operating manual P01120406 Current clamps for AC current Models MN12 and MN13
906131102B - Ed 1 2.04 (1/1) MN series ELECTRICAL SPECIFICATIONS
- Current range: 0.5 A AC .. 240 A AC
- Output signal: 1 mV AC / A AC (240 mV for 240 A)
- Accuracy and phase shift (1): % Accuracy of output signal ≤/uni00A03/uni00A0% + 5 mV ≤/uni00A02.5/uni00A0% + 5 mV ≤/uni00A02/uni00A0% + 5 mV ≤/uni00A01/uni00A0% + 5 mV Phase shift not specified ≤/uni00A05 ° ≤/uni00A03° ≤/uni00A02.5 °
- Bandwidth: 40 Hz .. 10 kHz
- Crest factor: 3 for a current of 200 ARMS
- Maximum currents:
200 A continuous for a frequency ≤/uni00A01 kHz (limitation
proportional to the inverse of frequency beyond)
- Load impedance: > 1 M/uni03A9
- Operating voltage: 600/uni00A0VRMS
- Common mode voltage: 600/uni00A0V category/uni00A0III and pollution degree 2
- Infl uence of adjacent conductor: ≤/uni00A015 mA / A at 50/60 Hz
- Infl uence of conductor position in jaws: ≤/uni00A00.5/uni00A0% of output signal at 50/60 Hz
- Infl uence of frequency (2): </uni00A03/uni00A0% of output signal from 40/uni00A0Hz .. 1/uni00A0kHz </uni00A012/uni00A0% of output signal from 1/uni00A0kHz .. 10/uni00A0kHz
- Infl uence of crest factor: </uni00A03/uni00A0% of output signal for a crest factor of 3 and current of 200 A RMS MECHANICAL SPECIFICATIONS
- Operating temperature: -10/uni00A0°C to +55 °C
- Storage temperature: -40/uni00A0°C to +70 °C
- Infl uence of temperature: ≤/uni00A00.15/uni00A0% of output signal per 10 °K
- Relative humidity for operation: 0 to 85/uni00A0% RH decreasing linearly above 35/uni00A0°C
- Infl uence of relative humidity: </uni00A00.2/uni00A0% of output signal of 10/uni00A0% at 90/uni00A0% RH
- Operating altitude: 0 to 2,000 m
- Max. jaw opening: 20/uni00A0mm
- Clamping capacity: Cable: Ø/uni00A0max 20/uni00A0mm Busbar: 1 busbar of 20 x 5/uni00A0mm
- Casing protection rating: IP40 (IEC/uni00A0529)
- Drop test: 1/uni00A0m (IEC/uni00A068-2-32)
- Shock resistance: 100 g (IEC/uni00A068-2-27)
- Vibration resistance: 10 / 55/10 Hz, 0.15/uni00A0mm (IEC/uni00A068-2-6)
- Self-extinguishing capability: Casing: UL94 V2 Jaws: UL94 V0
- Dimensions: 135 x 51 x 30/uni00A0mm
- Weight: 180 g
- Colours: Dark grey case with red jaws
- Output: MN14: Safety sockets (4/uni00A0mm) MN15: 1.5 m two-wire lead with double or reinforced insulation terminated by 2 elbowed male safety plugs (4/uni00A0mm) SAFETY SPECIFICATIONS
- Electrical safety: Instrument with double insulation or reinforced insulation between the primary, the secondary and the grippable part located under the guard as per IEC/uni00A01010-1 & IEC/uni00A01010-2-032 - 600/uni00A0V category/uni00A0III, pollution degree 2 - 300/uni00A0V category IV, pollution degree 2
- Electromagnetic compatibility (EMC): EN/uni00A050081-1: class B EN/uni00A050082-2: - Electrostatic discharge:/uni00A0IEC/uni00A01000-4-2 - Radiated field: IEC/uni00A01000-4-3 - Fast transients: IEC/uni00A01000-4-4 - Magnetic field at 50 Hz: IEC/uni00A01000-4-8 (1) Conditions of reference: 23 °C ± 3 °K, 20 to 70 % RH, sinusoidal signal with frequency of 48/uni00A0Hz to 65/uni00A0Hz, external magnetic fi eld </uni00A040/uni00A0A/m, no DC components, no external conductor with circulating current, conductor centred for measurement, load impedance > 1 MΩ. (2) Out of reference domain Current 200 A/uni00A0AC Output 1 mV / A To order Reference AC current clamp model MN14 with operating manual P01120416 AC current clamp model MN15 with operating manual P01120417 Current clamps for AC current Models MN14 and MN15
906131102B - Ed 1 2.05 (1/1) MN seriesCurrent clamp for AC current Model MN21
- Bandwidth: 40 Hz .. 10 kHz
- Crest factor: 5 for a current of 280 A peak
- Maximum currents:
(limitation proportional to the inverse of one third of frequency beyond)
- Load impedance: ≤/uni00A010 /uni03A9
- Maximum output voltage (secondary open): Limited to 8 V peak max.
- Operating voltage: 600/uni00A0VRMS
- Common mode voltage: 600/uni00A0V category/uni00A0III and pollution degree 2
- Infl uence of adjacent conductor: ≤/uni00A015 mA / A at 50 Hz
- Infl uence of conductor position in jaws: ≤/uni00A00.5/uni00A0% of output signal at 50/60 Hz
- Load infl uence: 0.1 .. 5 /uni03A9 </uni00A00.5/uni00A0% on measurement </uni00A00.5 ° on phase
- Infl uence of frequency Ip </uni00A0150 A (2): </uni00A05/uni00A0% of output signal from 40 Hz .. 1 kHz </uni00A015/uni00A0% of output signal from 1 kHz .. 10 kHz add 5/uni00A0% error if 150 A </uni00A0Ip </uni00A0200 A
- Infl uence of crest factor: </uni00A0 3/uni00A0 % of output signal for crest factor </uni00A0 5 with current </uni00A0280 A peak (50 A RMS) MECHANICAL SPECIFICATIONS
- Operating temperature: -10 °C to +55 °C
- Storage temperature: -40 °C to +70 °C
- Infl uence of temperature: ≤/uni00A00.20/uni00A0% of output signal per 10 °K
- Relative humidity for operation: 0 to 85/uni00A0% RH decreasing linearly above 35/uni00A0°C
- Infl uence of relative humidity: </uni00A00.2/uni00A0% of output signal from 10/uni00A0% to 85/uni00A0% RH
- Operating altitude: 0 to 2,000 m
- Max. jaw opening: 20/uni00A0mm
- Clamping capacity: Cable: Ø/uni00A0max 20/uni00A0mm Busbar: 1 busbar of 20 x 5/uni00A0mm
- Casing protection rating: IP40 (IEC/uni00A0529)
- Drop test: 1/uni00A0m (IEC/uni00A068-2-32)
- Shock resistance: 100 g (IEC/uni00A068-2-27)
- Vibration resistance: 10 / 55/10 Hz, 0.15/uni00A0mm (IEC/uni00A068-2-6)
- Self-extinguishing capability: Casing: UL94 V2 Jaws: UL94 V0
- Dimensions: 135 x 51 x 30/uni00A0mm
- Weight: 180 g
- Colours: Dark grey case with red jaws
- Output: 1.5 m two-wire lead with double or reinforced insulation terminated by 2 elbowed male safety plugs (4/uni00A0mm) SAFETY SPECIFICATIONS
- Electrical safety: Instrument with double insulation or reinforced insulation between the primary, the secondary and the grippable part located under the guard as per IEC/uni00A01010-1 & IEC/uni00A01010-2-032 - 600/uni00A0V category/uni00A0III, pollution degree 2 - 300/uni00A0V category IV, pollution degree 2
- Electromagnetic compatibility (EMC): EN/uni00A050081-1: class B EN/uni00A050082-2: - Electrostatic discharge: IEC/uni00A01000-4-2 - Radiated field: IEC/uni00A01000-4-3 - Fast transients: IEC/uni00A01000-4-4 - Magnetic field at 50 Hz: IEC/uni00A01000-4-8 (1) Conditions of reference: 23 °C ± 3 °K, 20 to 70 % RH, sinusoidal signal with frequency of 48/uni00A0Hz to 65/uni00A0Hz, external magnetic fi eld </uni00A040/uni00A0A/m, no DC components, no external conductor with circulating current, conductor centred for measurement, 1 Ω load. (2) Out of reference domain
An electronic voltage-limiting system protects output of clamp when operating, if the secondary circuit is opened. ELECTRICAL SPECIFICATIONS
- Current range: 0.1 A AC .. 240 A AC
- Current transformation ratio:
- Output signal: 1 mA/uni00A0AC / A AC (240 mA for 240 A)
- Accuracy and phase shift (1): % Accuracy of output signal ≤/uni00A02/uni00A0% + 20 µA ≤/uni00A01/uni00A0% + 20 µA ≤/uni00A01/uni00A0% ≤/uni00A02/uni00A0% ≤/uni00A04 % Phase shift not specified ≤/uni00A02° ≤/uni00A01.5 ° ≤/uni00A01.5 ° ≤/uni00A02° Current 200 A/uni00A0AC Ratio 1000 / 1 Output 1 mA / A To order Reference AC current clamp model MN21 with operating manual P01120418
906131102B - Ed 1 2.06 (1/1) MN seriesCurrent clamp for AC current Model MN23 ELECTRICAL SPECIFICATIONS
- Current range: 0.1 A/uni00A0AC .. 240 A/uni00A0AC
- Output signal: 10 mV AC / A/uni00A0AC (2.4 V for 240 A)
- Accuracy and phase shift (1): % Accuracy of output signal ≤/uni00A03 % + 200 µA ≤/uni00A02 % + 200 µA ≤/uni00A01 % ≤/uni00A04 % ≤/uni00A010 % Phase shift not specified ≤/uni00A03° ≤/uni00A02°≤/uni00A02.5 °≤/uni00A03.5 °
- Bandwidth: 40 Hz .. 10 kHz
- Crest factor: 5 for a current of 280 A peak
- Maximum currents:
proportional to the inverse of frequency beyond)
- Load impedance: > 1 M/uni03A9
- Operating voltage: 600/uni00A0VRMS
- Common mode voltage: 600/uni00A0V category/uni00A0III and pollution degree 2
- Infl uence of adjacent conductor: ≤/uni00A015 mA / A at 50 Hz
- Infl uence of conductor position in jaws: ≤/uni00A00.5/uni00A0% of output signal at 50/60 Hz
- Infl uence of frequency at IP </uni00A0100 A (2): < 5/uni00A0% of output signal from 40 Hz .. 1 kHz < 15/uni00A0% of output signal from 1 kHz .. 10 kHz Add 10/uni00A0% error if 100 </uni00A0IP </uni00A0200 A
- Infl uence of crest factor: </uni00A03 % of output signal for a crest factor </uni00A05 to a current </uni00A0280 A peak (50 A RMS) MECHANICAL SPECIFICATIONS
- Operating temperature: -10 °C to +55 °C
- Storage temperature: -40 °C to +70 °C
- Infl uence of temperature: ≤/uni00A00.20 % of output signal per 10 °K
- Relative humidity for operation: 0 to 85/uni00A0% RH decreasing linearly above 35 °C
- Infl uence of relative humidity: </uni00A00.2 % of output signal from 10/uni00A0% to 85/uni00A0% RH
- Operating altitude: 0 to 2,000 m
- Max. jaw opening: 20/uni00A0mm
- Clamping capacity: Cable: Ø/uni00A0max 20/uni00A0mm Busbar: 1 busbar of 20 x 5/uni00A0mm
- Casing protection rating: IP40 (IEC/uni00A0529)
- Drop test: 1/uni00A0m (IEC/uni00A068-2-32)
- Shock resistance: 100 g (IEC/uni00A068-2-27)
- Vibration resistance: 10 / 55/10 Hz, 0.15/uni00A0mm (IEC/uni00A068-2-6)
- Self-extinguishing capability: Casing: UL94 V2 Jaws: UL94 V0
- Dimensions: 135 x 51 x 30/uni00A0mm
- Weight: 180 g
- Colours: Dark grey case with red jaws
- Output: 1.5 m two-wire lead with double or reinforced insulation terminated by 2 elbowed male safety plugs (4/uni00A0mm) SAFETY SPECIFICATIONS
- Electrical safety: Instrument with double insulation or reinforced insulation between the primary, the secondary and the grippable part located under the guard as per IEC/uni00A01010-1 & IEC/uni00A01010-2-032 - 606.5/uni00A0V category III, pollution degree 2 - 306.5/uni00A0V category IV, pollution degree 2
- Electromagnetic compatibility (EMC): EN/uni00A050081-1: class/uni00A0B EN/uni00A050082-2: - Electrostatic discharge: IEC/uni00A01000-4-2 - Radiated field: IEC/uni00A01000-4-3 - Fast transients: IEC/uni00A01000-4-4 - Magnetic field at 50 Hz: IEC/uni00A01000-4-8 (1) Conditions of reference: 23 °C ± 3 °K, 20 to 70 % RH, sinusoidal signal with frequency of 48/uni00A0Hz to 65/uni00A0Hz, external magnetic fi eld </uni00A040/uni00A0A/m, no DC components, no external conductor with circulating current, conductor centred for measurement, load impedance > 1 MΩ. (2) Out of reference domain. Current 200 A/uni00A0AC Output 10 mV / A To order Reference AC current clamp model MN23 with operating manual P01120419
906131102B - Ed 1 2.07 (1/1) MN series (1) Conditions of reference: 23 °C ± 3 °K, 20 to 70 % RH, sinusoidal signal with frequency of 48 Hz to 65 Hz, external magnetic fi eld < 40 A/m, no DC components, no external conductor with circulating current, conductor centred for measurement, load impedance > 1 M/uni03A9. (2) Out of reference domain ELECTRICAL SPECIFICATIONS
- Current range: 0.1 A/uni00A0AC .. 24 A/uni00A0AC 0.5 A/uni00A0AC .. 240 A/uni00A0AC
- Output signal: 100 mV AC / A/uni00A0AC (2.4 V for 24 A) 10 mV AC / A/uni00A0AC (2.4 V for 240 A)
- Accuracy and phase shift (1): Calibre 20 A 200 A % Accuracy of output signal ≤/uni00A01 % + 50 mV ≤/uni00A03 % + 5 mV ≤/uni00A02.5 % + 5 mV ≤/uni00A02 % + 5 mV≤/uni00A01 % + 5 mV Phase shift not specified not specified ≤/uni00A05 ° ≤/uni00A03° ≤/uni00A02.5 °
- Bandwidth: 40 Hz .. 10 kHz
- Crest factor: 3 for a current of 200 ARMS
- Maximum currents:
200 A continuous for a frequency ≤ 1 kHz (limitation
proportional to the inverse of frequency beyond)
- Load impedance: > 1 M/uni03A9
- Operating voltage: 600/uni00A0VRMS
- Common mode voltage:
600 V category III and pollution degree 2
- Infl uence of adjacent conductor: ≤/uni00A015 mA / A at 50 Hz
- Infl uence of conductor position in jaws: ≤/uni00A00.5 % of output signal at 50/60 Hz
- Infl uence of frequency (2): I 20 A calibre: </uni00A05 % of output signal from 40 Hz .. 1 kHz </uni00A015 % of output signal from 1 kHz .. 10/uni00A0kHz I 200 A calibre: </uni00A03 % of output signal from 40 Hz .. 1 kHz </uni00A012 % of output signal from 1/uni00A0kHz .. 10/uni00A0kHz
- Infl uence of crest factor: </uni00A03 % of output signal for a crest factor of 3 and current of 200 A RMS MECHANICAL SPECIFICATIONS
- Operating temperature: -10 °C to +55 °C
- Storage temperature: -40 °C to +70 °C
- Infl uence of temperature: ≤/uni00A00.15 % of output signal per 10 °K
- Relative humidity for operation: 0 to 85/uni00A0% RH decreasing linearly above 35 °C
- Infl uence of relative humidity: </uni00A00.2 % of output signal from 10/uni00A0% to 85/uni00A0% RH
- Operating altitude: 0 to 2,000 m
- Max. jaw opening: 20/uni00A0mm
- Clamping capacity: Cable: Ø/uni00A0max 20/uni00A0mm Busbar: 1 busbar of 20/uni00A0mm x 5/uni00A0mm
- Casing protection rating: IP40 (IEC/uni00A0529)
- Drop test: 1/uni00A0m (IEC/uni00A068-2-32)
- Shock resistance: 100 g (IEC/uni00A068-2-27)
- Vibration resistance: 10 / 55/10 Hz, 0.15/uni00A0mm (IEC/uni00A068-2-6)
- Self-extinguishing capability: Casing: UL94 V2 Jaws: UL94 V0
- Dimensions: 135 x 51 x 30/uni00A0mm
- Weight: 180 g
- Colours: Dark grey case with red jaws
- Output: MN38: Safety jacks (4/uni00A0mm) MN39: 1.5 m two-wire lead with double or reinforced insulation terminated by 2 elbowed male safety plugs (4 mm) SAFETY SPECIFICATIONS
- Electrical safety: Instrument with double insulation or reinforced insulation between the primary the secondary and the grippable part located under the guard as per IEC/uni00A01010-1 & IEC/uni00A01010-2-032 - 600/uni00A0V category III, pollution degree 2 - 300/uni00A0V category IV, pollution degree 2
- Electromagnetic compatibility (EMC): EN/uni00A050081-1: class/uni00A0B EN/uni00A050082-2: - Electrostatic discharge: IEC/uni00A01000-4-2 - Radiated field: IEC/uni00A01000-4-3 - Fast transients: IEC/uni00A01000-4-4 - Magnetic field at 50/60 Hz: IEC/uni00A01000-4-8 Current 20 A/uni00A0AC 200 A/uni00A0AC Output 100 mV / A 10 mV / A To order Reference AC current clamp model MN38 with operating manual P01120407 AC current clamp model MN39 with operating manual P01120408 Current clamps for AC current Models MN38 and MN39
906131102B - Ed 1 2.08 (1/4) MN seriesOscilloscope clamp for AC current Model MN60 (insulated AC current probe) This 200 A AC clamp enables easy display and measurement of “current” curves. It fi ts any oscilloscope since it has a coaxial lead with BNC plug. It produces a mV signal directly proportional to current. It offers 2 different sensitivities. ELECTRICAL SPECIFICATIONS
- Current range: 0.1 A/uni00A0AC .. 20 A/uni00A0AC (60 A peak) 0.5 A/uni00A0AC .. 200 A/uni00A0AC (600 A peak)
- Output signal: 100 mV AC / A/uni00A0AC (2 V for 20 A) 10 mV AC / A/uni00A0AC (2 V for 200 A)
- Accuracy and phase shift (1): Calibre 20 A 200 A % Accuracy of output signal ≤/uni00A02 % + 50 mV ≤/uni00A03.5 % + 5 mV ≤/uni00A03 % + 5 mV ≤/uni00A02.5 % + 5 mV≤/uni00A01.5 % + 5 mV Phase shift not specified not specified ≤/uni00A06° ≤/uni00A04° ≤/uni00A03°
- Bandwidth: 40 Hz .. 40 kHz (-3 dB) (depending on current value)
- Rise/fall time from 10 % to 90 %: I 20 A calibre: 7.4 µs I 200 A calibre: 8.7 µs
- 10 % delay time: 0.1 µs
- Ampere second product: I 20 A calibre: 25 A.s I 200 A calibre: 2 A.s
- Insertion impedance (at 400 Hz / 10 kHz) I 20 A calibre: < 0.3 m/uni03A9 / < 7.2 m/uni03A9 I 200 A calibre: < 1 m/uni03A9 / < 26 m/uni03A9
- Maximum currents:
200 A continuous for a frequency ≤ 3 kHz
(limitation proportional to inverse of one third of frequency beyond)
- Infl uence of temperature: ≤ 150 ppm /k or 0.15 % of output signal per 10 °K
- Infl uence of relative humidity: < 0.2 % of output signal
- Infl uence of adjacent conductor: ≤/uni00A015 mA / A at 50 Hz
- Infl uence of DC current < 10 % of rated calibre superimposed on the rated current: I 20 A calibre: For I DC < 2 A: influence < 0.5 % I 200 A calibre: For I DC < 20 A: influence < 5 %
- Infl uence of conductor position in jaws: ≤/uni00A00.5 % of output signal at 50/60 Hz
- Infl uence of frequency (2): I 20 A calibre: </uni00A010 % of output signal from 40 Hz .. 1/uni00A0kHz </uni00A015 % of output signal from 1 kHz .. 10 kHz I 200 A calibre: </uni00A03 % of output signal from 40 Hz .. 1 kHz </uni00A012 % of output signal from 1 kHz .. 10 kHz
- Infl uence of crest factor: </uni00A03 % of output signal for a crest factor of 3 and current of 200 A RMS MECHANICAL SPECIFICATIONS
- Operating temperature: /uni00A0-10 °C to +55 °C
- Storage temperature: -40 °C to +70 °C
- Relative humidity for operation: 0 to 85/uni00A0% RH decreasing linearly above 35 °C
- Operating altitude: 0 to 2,000 m
- Max. jaw opening: 20/uni00A0mm
- Clamping capacity: Cable: Ø max 20/uni00A0mm Busbar: 1 busbar of 20 x 5/uni00A0mm
- Casing protection rating: IP40 (IEC/uni00A0529)
- Drop test: 1 m (IEC/uni00A068-2-32)
- Shock resistance: 100 g / 6 ms / half-periode (IEC/uni00A068-2-27)
- Protection against impacts: IK04 0.5 J (EN 50102)
- Vibration resistance: 10 / 55/10 Hz, 0.15/uni00A0mm (IEC/uni00A068-2-6)
- Self-extinguishing capability: Casing: UL94 V2 Jaws: UL94 V0
- Dimensions: 128 x 49 x 28/uni00A0mm
- Weight: 180 g
- Colours: Dark grey case with red jaws
- Output: Coaxial cable 2 m long, terminated by an insulated BNC connector SAFETY SPECIFICATIONS
- Electrical safety: Instrument with double insulation or reinforced insulation between the primary, the secondary and the grippable part located under the guard as per IEC 1010-1 & IEC 1010-2-032 - 600/uni00A0V category III, pollution degree 2 - 300/uni00A0V category IV, pollution degree 2
- Electromagnetic compatibility (EMC): EN/uni00A050081-1: class/uni00A0B EN/uni00A050082-2: - Electrostatic discharge: IEC/uni00A01000-4-2 4/uni00A0kV level 2 performance criterion B 8 kV in the air level 3 performance criterion B - Radiated field: IEC/uni00A01000-4-3
10 V/m performance criterion/uni00A0A
- Fast transients: IEC/uni00A01000-4-4 1 kV level 2 performance criterion B 2 kV level 3 performance criterion B - Magnetic field at 50/60 Hz: IEC/uni00A01000-4-8 field of 400 A/m at 50 Hz: < 1 A Current 60 A peak 600 A peak Output 100 mV / A 10 mV / A
906131102B - Ed 1 2.08 (2/4) MN seriesOscilloscope clamp for AC current Model MN60 (insulated AC current probe) CURVES AT 50 Hz
200 A calibre 20 A calibre
Primary current in A at 50 Hz Error on measurement in % -60.00 -50.00 -40.00 -30.00 -20.00 -10.00 0.00 10.00 Typical error FT limit Primary current in A at 50 Hz Error on measurement in % -100.00 -90.00 -80.00 -70.00 -60.00 -50.00 -40.00 -30.00 -20.00 -10.00 0.00 10.00 00.00100.0100.101.0 Typical error FT limit Phase shift Primary current in A at 50 Hz Phase shift in ° 0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 00.000100.00100.0100.1 Typical phase FT limite FREQUENCY RESPONSE Error on measurement in % -30.00 -25.00 -20.00 -15.00 -10.00 -5.00 0.00 5.00 E % at 10 A E % at 40 A Frequency in Hz Error on measurement in % -40.00 -30.00 -20.00 -10.00 0.00 10.00 E % at 1 A E % at 4 A Frequency in Hz Phase in ° -40.00 -30.00 -20.00 -10.00 0.00 10.00 20.00 30.00 40.00 50.00 Phase at 1 A Phase at 4 A
906131102B - Ed 1 2.08 (3/4) MN seriesOscilloscope clamp for AC current Model MN60 (insulated AC current probe) FREQUENCY RESPONSE (CONT.) Error on measurement in % -10.00 -8.00 -6.00 -4.00 -2.00 0.00 2.00 E % at 100 A E % at 200 A Frequency in Hz Error on measurement in % -30.00 -25.00 -20.00 -15.00 -10.00 -5.00 0.00 5.00 E % at 10 A E % at 20 A Frequency in Hz Phase in ° -25.00 -20.00 -15.00 -10.00 -5.00 0.00 5.00 10.00 15.00 Phase at 100 A Phase at 200 A Frequency in Hz Phase in ° -40.00 -30.00 -20.00 -10.00 0.00 10.00 20.00 30.00 40.00 Phase at 10 A Phase at 20 A RESPONSE TO A SQUARE SIGNAL
10 A at 10 Hz
10 A at 100 Hz
906131102B - Ed 1 2.08 (4/4) MN seriesOscilloscope clamp for AC current Model MN60 (insulated AC current probe) (1) Conditions of reference: 23 °C ± 3 °K, 20 % to 75 % RH, sinusoidal signal with frequency of 48 Hz at 1 kHz, external magnetic fi eld < 40 A/m, no DC components, no external conductor with circulating current, conductor centred for measurement, load impedance > 1 M/uni03A9 and < 100 pF. (2) Out of reference domain RESPONSE TO A SQUARE SIGNAL (CONT.)
10 A at 1 kHz
10 A at 10 kHz
AC current clamp model MN60 for oscilloscope with operating manual P01120409
906131102B - Ed 1 2.09 (1/1) MN seriesCurrent clamp for AC current Model MN71 ELECTRICAL SPECIFICATIONS
- Current range: 0.01 A/uni00A0AC .. 12 A/uni00A0AC
- Output signal: 100 mV AC / A/uni00A0AC (1.2 V for 12 A)
- Accuracy and phase shift (1): Accuracy in % of output signal ≤/uni00A03 % + 0.1 mV ≤/uni00A02.5 % ≤/uni00A01 % Phase shift not specified ≤/uni00A05 ° ≤/uni00A03° ≤/uni00A03°
- Bandwidth: 40 Hz .. 10 kHz
- Crest factor: 5 for a current of 40 A peak (8 ARMS)
- Maximum currents:
20 A continuous for a frequency ≤/uni00A010
kHz (limitation proportional to the inverse of one tenth of frequency beyond)
- Load impedance: > 1 M/uni03A9
- Operating voltage: 600/uni00A0VRMS
- Common mode voltage:
- Infl uence of adjacent conductor: </uni00A015 mA / A at 50 Hz
- Infl uence of conductor position in jaws: </uni00A00.5 % of output signal at 50/60 Hz
- Infl uence of frequency (2): </uni00A05 % of output signal from 20 Hz .. 1 kHz </uni00A010 % of output signal from/uni00A01 kHz .. 10 kHz
- Infl uence of crest factor: </uni00A0 3 % of output signal for crest factor </uni00A0 5 with current </uni00A040 A RMS MECHANICAL SPECIFICATIONS
- Operating temperature: -10 °C to +55 °C
- Storage temperature: -40 °C to +70 °C
- Infl uence of temperature: ≤/uni00A00.2 % of output signal per 10 °K
- Relative humidity for operation: 0 to 85/uni00A0% RH decreasing linearly above 35 °C
- Infl uence of relative humidity: </uni00A00.2 % of output signal from 10/uni00A0% to 85/uni00A0% RH
- Operating altitude: 0 to 2,000 m
- Max. jaw opening: 20/uni00A0mm
- Clamping capacity: Cable: Ø max 20/uni00A0mm Busbar: 1 busbar of 20 x 5/uni00A0mm
- Casing protection rating: IP40 (IEC/uni00A0529)
- Drop test: 1/uni00A0m (IEC/uni00A068-2-32)
- Shock resistance: 100 g (IEC/uni00A068-2-27)
- Vibration resistance: 10 / 55/10 Hz, 0.15/uni00A0mm (IEC/uni00A068-2-6)
- Self-extinguishing capability: Casing: UL94 V2 Jaws: UL94 V0
- Dimensions: 135 x 51 x 30/uni00A0mm
- Weight: 180 g
- Colours: Dark grey case with red jaws
- Output: 1.5 m two-wire lead with double or reinforced insulation terminated by 2/uni00A0 elbowed male safety plugs (4 mm) SAFETY SPECIFICATIONS:
- Electrical safety: Instrument with double insulation or reinforced insulation between the primary the secondary and the grippable part located under the guard as per IEC/uni00A01010-1 & IEC/uni00A01010-2-032 - 600/uni00A0V category III, pollution degree 2 - 300/uni00A0V category IV, pollution degree 2
- Electromagnetic compatibility (EMC): EN/uni00A050081-1: class/uni00A0B EN/uni00A050082-2: - Electrostatic discharge: IEC/uni00A01000-4-2 - Radiated field: IEC/uni00A01000-4-3 - Fast transients: IEC/uni00A01000-4-4 - Magnetic field at 50 Hz: IEC/uni00A01000-4-8 (1) Conditions of reference: 23 °C ± 3 °K, 20 % to 75 % RH, sinusoidal signal with frequency of 48 Hz to 65 Hz, external magnetic fi eld </uni00A040/uni00A0A/m, no DC components, no external conductor with circulating current, conductor centred for measurement, load impedance > 1 MΩ. (2) Out of reference domain
This clamp was specially designed to measure current on current transformer secondary circuits. Current 10 A/uni00A0AC Output 100 mV / A To order Reference AC current clamp model MN71 with operating manual P01120420
906131102B - Ed 1 2.10 (1/1) MN seriesCurrent clamp for AC current Model MN73 (1) Conditions of reference: 23 °C ± 3 °K, 20 % to 75 % RH, sinusoidal signal with frequency of 48 Hz to 65 Hz, external magnetic fi eld </uni00A040/uni00A0A/m, no DC components, no external conductor with circulating current, conductor centred for measurement, load impedance > 1 MΩ. (2) Out of reference domain ELECTRICAL SPECIFICATIONS
- Current calibres: 0.01 A/uni00A0AC .. 2.4 A/uni00A0AC 0.1 A/uni00A0AC .. 240 A/uni00A0AC
- Output signal: 1,000 mV AC / A/uni00A0AC (2 V for 2 A) 10 mV AC / A/uni00A0AC (2.4 V for 240 A)
- Accuracy and phase shift (1): Calibre 2 A 200 A % Accuracy of output signal ≤/uni00A05 % + 2 mV ≤/uni00A03 % + 1 mV ≤/uni00A01 %≤/uni00A01 %≤/uni00A03 % + 200 µV ≤/uni00A02 % + 200 µV ≤/uni00A01 % ≤/uni00A04 % ≤/uni00A010 % Phase shift not specified not specified ≤/uni00A03° ≤/uni00A02° ≤/uni00A03° ≤/uni00A04°
- Bandwidth: 40 Hz .. 10 kHz
- Crest factor: 5 for a current of 280 A peak (200/uni00A0ARMS)
- Maximum currents:
200 A continuous for a frequency ≤ /uni00A0 1/uni00A0 kHz
(limitation proportional to the inverse frequency beyond)
- Load impedance: > 1 M/uni03A9
- Operating voltage: 600/uni00A0VRMS
- Common mode voltage:
- Infl uence of adjacent conductor: ≤/uni00A015 mA / A at 50 Hz
- Infl uence of conductor position in jaws: ≤/uni00A00.5 % of output signal at 50/60 Hz
- Infl uence of frequency (2): I Calibre 2 A: </uni00A010 % of output signal from 40/uni00A0Hz .. 10 kHz I 200 A calibre: </uni00A05 % of output signal from 40 Hz .. 1 kHz </uni00A015 % of output signal from 1 kHz .. 10 kHz add 10 % error if 100 A </uni00A0I Primary </uni00A0200 A
- Infl uence of crest factor: </uni00A0 5 % of output signal for crest factor </uni00A0 5 with current </uni00A0280 A RMS MECHANICAL SPECIFICATIONS
- Operating temperature: -10 °C to +55 °C
- Storage temperature: -40 °C to +70 °C
- Infl uence of temperature: ≤/uni00A00.20 % of output signal per 10 °K
- Relative humidity for operation: 0 to 85/uni00A0% RH decreasing linearly above 35 °C
- Infl uence of relative humidity: </uni00A00.2 % of output signal from 10/uni00A0% to 85/uni00A0% RH
- Operating altitude: 0 to 2,000 m
- Max. jaw opening: 20/uni00A0mm
- Clamping capacity: Cable: Ø max 20/uni00A0mm Busbar: 1 busbar of 20 x 5/uni00A0mm
- Casing protection rating: IP40 (IEC/uni00A0529)
- Drop test: 1 m (IEC/uni00A068-2-32)
- Shock resistance: 100 g (IEC/uni00A068-2-27)
- Vibration resistance: 10 / 55/10 Hz, 0.15/uni00A0mm (IEC/uni00A068-2-6)
- Self-extinguishing capability: Casing: UL94 V2 Jaws: UL94 V0
- Dimensions: 135 x 51 x 30/uni00A0mm
- Weight: 180 g
- Colours: Dark grey case with red jaws
- Output: 1.5 m two-wire lead with double or reinforced insulation terminated by 2 elbowed male safety plugs (4 mm) SAFETY SPECIFICATIONS
- Electrical safety: Instrument with double insulation or reinforced insulation between the primary the secondary and the grippable part located under the guard as per IEC/uni00A01010-1 & IEC/uni00A01010-2-032 - 600/uni00A0V category III, pollution degree 2 - 300/uni00A0V category IV, pollution degree 2
- Electromagnetic compatibility (EMC): EN/uni00A050081-1: class/uni00A0B EN/uni00A050082-2: - Electrostatic discharge: IEC/uni00A01000-4-2 - Radiated field: IEC/uni00A01000-4-3 - Fast transients: IEC/uni00A01000-4-4 - Magnetic field at 50 Hz: IEC/uni00A01000-4-8
This clamp has a wide measurement range (up to 200/uni00A0 A), and it can also measure very low currents. We call it the “universal” probe. Current 2 A/uni00A0AC 200 A/uni00A0AC Output 1,000 mV / A 10 mV / A To order Reference AC current clamp model MN73 with operating manual P01120421 Accessory: AN1 artificial neutral box (see capter 12) P01197201
906131102B - Ed 1 2.11 (1/1) MN seriesCurrent clamps for AC current ELECTRICAL SPECIFICATIONS
- Current range: 0.5 A/uni00A0AC .. 240 A/uni00A0AC
- Output signal: 100 mV DC / A (24 V for 240 A/uni00A0AC)
- Accuracy (1): % Accuracy of output signal ≤/uni00A05 % + 50 mV ≤/uni00A03 % + 50 mV≤/uni00A02 % + 50 mV≤/uni00A02 % (1) Conditions of reference: 23 °C ± 3 °K, 20 to 70 % RH, sinusoidal signal with frequency of 48 Hz to 65 Hz, external magnetic fi eld </uni00A040/uni00A0A/m, no DC components, no external conductor with circulating current, conductor centred for measurement, load impedance > 1 MΩ + fi lter RC 2s. (2) Out of reference domain
- Bandwidth: 40 Hz .. 10 kHz
- Crest factor: 3 for a current of 200 ARMS
- Maximum currents:
200 A continuous for a frequency ≤/uni00A01/uni00A0kHz (derating
proportional to the inverse of frequency beyond)
- Load impedance: > (1 M/uni03A9 + filter RC 2s)
- Operating voltage: 600/uni00A0VRMS
- Common mode voltage:
- Infl uence of adjacent conductor: ≤/uni00A015 mA / A at 50 Hz
- Infl uence of conductor position in jaws: ≤/uni00A00.5 % of output signal at 50 Hz
- Infl uence of frequency (2): </uni00A05 % of output signal from 40 Hz .. 1 kHz </uni00A012 % of output signal from 1 kHz .. 10 kHz
- Infl uence of crest factor </uni00A03 % of output signal for a crest factor of 3 and current of 200 A RMS MECHANICAL SPECIFICATIONS
- Operating temperature: -10 °C to +55 °C
- Storage temperature: -40 °C to +70 °C
- Infl uence of temperature: ≤/uni00A00.15 % of output signal per 10 °K
- Relative humidity for operation: 0 to 85/uni00A0% RH decreasing linearly above 35 °C
- Infl uence of relative humidity: </uni00A00.2 % of output signal from 10/uni00A0% to 85/uni00A0% RH
- Operating altitude: 0 to 2,000 m
- Max. jaw opening: 20/uni00A0mm
- Clamping capacity: Cable: Ø max 20/uni00A0mm Busbar: 1 busbar of 20 x 5/uni00A0mm
- Casing protection rating: IP40 (IEC/uni00A0529)
- Drop test: 1/uni00A0m (IEC/uni00A068-2-32)
- Shock resistance: 100 g (IEC/uni00A068-2-27)
- Vibration resistance: 10 / 55/10 Hz, 0.15/uni00A0mm (IEC/uni00A068-2-6)
- Self-extinguishing capability: Casing: UL94 V2 Jaws: UL94 V0
- Dimensions: 135 x 51 x 30/uni00A0mm
- Weight: 180 g
- Colours: Dark grey case with red jaws
- Output: MN88: Safety jacks (4/uni00A0mm) MN89: 1.5 m two-wire lead with double or reinforced insulation terminated by 2 elbowed male safety plugs (4 mm) SAFETY SPECIFICATIONS
- Electrical safety: Instrument with double insulation or reinforced insulation between the primary the secondary and the grippable part located under the guard as per IEC/uni00A01010-1 & IEC/uni00A01010-2-032 - 600/uni00A0V category III, pollution degree 2 - 300/uni00A0V category IV, pollution degree 2
- Electromagnetic compatibility (EMC): EN/uni00A050081-1: class/uni00A0B EN/uni00A050082-2: - Electrostatic discharge: IEC/uni00A01000-4-2 - Radiated field: IEC/uni00A01000-4-3 - Fast transients: IEC/uni00A01000-4-4 - Magnetic field at 50/60 Hz: IEC/uni00A01000-4-8
These clamps produce a DC voltage output which is very useful for multimeters whose sensitivity in V or A is too weak. Current 200 A/uni00A0AC Output 100 mV/uni00A0DC / A To order Reference AC current clamp model MN88 with operating manual P01120410 AC current clamp model MN89 with operating manual P01120415 Models MN88 and MN89