www.micropowerdirect.com MicroPower Direct
292 Page Street
Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com Key Features: 20W Output Power 4:1 Input Range Miniature 1” x 1” Case Effi ciency To 90% 1,500 VDC Isolation >1 MHour MTBF Chassis Mount Available DIN Rail Mount Available MI2000ERU Wide 4:1 Input, 20W Miniature 1” x 1” DC/DC Con vert ers Series Input Parameter Conditions Min. Typ. Max. Units Input Start-up Threshold 24 VDC Input 9.0 VDC48 VDC Input 18.0 Under Voltage Shutdown 24 VDC Input 6.0 VDC48 VDC Input 15.0 Refl ected Ripple Current 30 mA Input Filter Pi (/H9266) Filter Output Parameter Conditions Min. Typ. Max. Units Output Voltage Accuracy ±1.0 ±3.0 % Line Regulation VIN = Min to Max ±0.2 ±0.5 % Load Regulation I OUT = 5% to 100% ±0.5 ±1.0 % Ripple & Noise (20 MHz) See Note 1 50 120 mV P - P Transient Recovery Time , See Note 2 25% Load Step Change 300 500 µSec Transient Response Deviation ±3.0 ±5.0 % Temperature Coeffi cient ±0.02 %/ºC Over Temperature Protection 110 ºC Output Over Load Protection 150 %I OUT Output Short Circuit Continuous (Autorecovery) General Parameter Conditions Min. Typ. Max. Units Isolation Voltage 60 Seconds 1,500 VDC Isolation Resistance 500 VDC 1,000 M Isolation Capacitance 100 kHz, 0.1V 1,000 pF Switching Frequency 320 kHz Environmental Parameter Conditions Min. Typ. Max. Units Operating Temperature Range Ambient -40 +85 ºC Storage Temperature Range -55 +125 ºC Cooling Free Air Convection Humidity RH, Non-condensing 95 % Physical Case Size See Mechanical Diagrams (Page 4) Case Material Aluminum (UL94-V0) Weight See Mechanical Diagrams (Pages 4,5,6) Remote On/Off Parameter Conditions Min. Typ. Max. Units Unit On See Note 3 2.5 12.0 VDC Unit Off See Note 3 0 1.2 VDC Off Idle Current 5.0 mA Reliability Specifi cations Parameter Conditions Min. Typ. Max. Units MTBF MIL HDBK 217F , 25ºC, Gnd Benign 1.0 MHours Absolute Maximum Ratings Parameter Conditions Min. Typ. Max. Units Input Voltage Surge (1 Sec) 24 VDC Input 50.0 VDC48 VDC Input 100.0 Lead Temperature 1.5 mm From Case For 10 Sec 300 ºC Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. Electrical Specifi cations Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice. Cost Cutter
www.micropowerdirect.com MicroPower Direct • 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com Model Number Input Output Capacitive Load (µF Max) Effi ciency (%, Typ) Fuse Rating Slow-Blow (mA) Voltage (VDC) Current (mA) Voltage (VDC) Current (mA, Max) Current (mA, Min)Nominal Range Full-Load No-Load MI2024S-03ERU-xxxx 24 9.0 - 36.0 790 60 3.3 5,000 250 10,300 87 4,000 MI2024S-12ERU-xxxx 24 9.0 - 36.0 926 60 12.0 1,667 84 1,200 90 5,000 MI2024S-15ERU-xxxx 24 9.0 - 36.0 926 60 15.0 1,333 67 750 90 5,000 MI2048S-03ERU-xxxx 48 18.0 - 75.0 391 30 3.3 5,000 250 10,300 88 2,000 MI2048S-05ERU-xxxx 48 18.0 - 75.0 462 30 5.0 4,000 200 5,400 90 2,500 MI2048S-15ERU-xxxx 48 18.0 - 75.0 463 30 15.0 1,333 67 750 90 2,500 Model Selection Guide Derating Curve, <5 VOUT Notes: 1. When measuring output ripple & noise, it is recommended that external capaci- tors (10 µF & 1 µF) be connected in parallel from the +VOUT to the -VOUT pins. 2. Transient recovery is measured to within a 1% error band for a load step change of 25%. 3. The voltage at the Remote On/Off pin (Pin 6) is referenced to the -VIN input (Pin 2). If the on/off pin is left open, the unit operates. If it is grounded, the unit will shut off. 4. Operation at no-load will not damage these units. However, they may not meet all specifi cations. The recommended minimum load is given in the model selection table above. 5. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection table above for the correct rating. Derating Curve, >5 VOUT For the heatsink option, add suffi x “H” to the model number (i.e. MI2024S-12ERU-H) For the chassis mount adapter board option, add suffi x “A2S” to the model number (i.e. MI2024S-12ERU-A2S) For the DIN rail mount adapter board option, add suffi x “A4S” to the model number (i.e. MI2024S-12ERU-A4S) External Trim Parameter Output Voltage (VDC) 3.3 5.0 12 15 R1 (k/H9024) 4.841 15.000 10.000 15.000 R2 (k/H9024) 2.870 15.000 2.609 3.000 R3 (k/H9024) 12.400 15.000 15.000 20.000 VREF (V) 1.24 2.50 2.50 2.50 External Trim Notes: An external resistor can be used to adjust the converter output up/down by about 10%. The connection is shown in the diagram at left. The required resistor value is calculated by the formulas: Where R TRIM = The value of the external trim resistor V TRIM = The amount of voltage adjustment required The value of R1, R2, R3 and VREF are given in the table below. If not used, the Trim pin (pin 4) should be left open. Trim Up = R TRIM = A x R2 -R3 Where: A = VREF x R1 R2 - A VTRIM - VREF Trim Down = R TRIM = A x R1 -R3 Where: A = VTRIM - VREF x R2 R1 - A VREF
MicroPower Direct • 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com www.micropowerdirect.com Parameter Standard Criteria Level Radiated Emissions, See Note 1 EN 55022 Class A Conducted Emissions, See Note 1 EN 55022 Class A ESD EN 61000-4-2 B ±4 kV Contact RS EN 61000-4-3 A 10V/m EFT, See Note 2 EN 61000-4-4 B ±2 kV Surge, See Note 3 EN 61000-4-5 B ±2 kV CS EN 61000-4-6 A 3 Vrms Voltage Dips EN 61000-4-29 B 0% - 70% EMC Specifi cations Notes: 1. All units will meet class A with the addition of the capacitors shown in the “Simple Connection” diagram. To meet the requirements of Class B, refer to the “Typical Connection” circuit. Contact the factory for more information. 2. To meet the requirements of EN 61000-4-4 (±2 kV), external components are needed, as shown in the “Typical Connection” diagram. Contact the factory for more information. 3. To meet the requirements of EN 61000-4-5 (±2 kV ), external components are needed, as shown in the “Typical Connection” diagram. Contact the factory for more information. Typical Connection Typical Board Layout: With Filtering Components Simple Connection The diagram at left illustrates a typical connection of the MI20xxS-xxERU series. Capacitors C 1 and C2 are fi ltering components. They are required to meet the EN 55022 requirements for Class A. The recommended component values are given in the table below. VOUT C1 (µF) C 3 (µF) 3.3/5 VDC 100 470 12/15 VDC 100 220 The diagram above illustrates a typical connection of the MI20xxSERU series. for an application that requires compliance to with input surge and EMC standards EN 55022 and EN 61000 (as specifi ed above). Some notes on these components are: 1. It is recommended that an external fuse be used. The recommended fuse is shown in the model chart on page 2. 2. An external MOV is recommended on the input to protect the unit in the event of a surge. A recommended value is given in the table at right. 3. The output fi ltering capacitor (C 3) is a high frequency, low resistance electrolytic capacitor. Care must be taken in choosing this capacitor not to exceed the capacitive load specifi cation for the unit. Voltage derating of capacitors should be 80% or above. 4. Suggested component values are: Component VIN: 24V V IN: 48V MOV S14K35 S14K60 C1 330µF/50V 330µF/100V C2 1 µF/50V 1 µF/100V C3 Refer to the values for the “Simple Connection” LDM1 4.7 µH 4.7 µH CY1, CY2 1 nF/2 kV 1 nF/2 kV 5. In many applications, simply adding input/output capacitors will en- hance the input surge protection & and reduce output ripple suf- fi ciently. In this case, capacitors C 1 and C3 could be connected as shown above, without the other fi lter components. Recommended capacitor values are given in the table above. The diagram at left shows a typical PC board layout for the MI20xxSERU with the input surge and fi lter components shown above. The minimum distance between the bonding pads for capacitors C Y1 and C Y2 must be > 2mm,
www.micropowerdirect.com MicroPower Direct • 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com Notes:
- All dimensions are typical in inches (mm)
- Tolerance x.xx = ±0.02 (±0.50) Mechanical Dimensions Mechanical Dimensions: With Optional Heatsink Pin Single Output 1- V IN 2+ V IN 3+ V OUT
4 Trim
6 Remote On/Off
For the heatsink option, add suffi x “H” to the model number (i.e. MI2024S-12ERU-H) Pin Single Output 1- V IN 2+ V IN 3+ V OUT Weight: 0.53 Oz (15g) Weight: 0.707 Oz (20g)
MicroPower Direct • 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com www.micropowerdirect.com Mechanical Dimensions: With A2S Adapter Board Mechanical Dimensions: With A4S Adapter Board For the A2S adapter board option, add suffi x “A2S” to the model number (i.e. MI2024S-12ERU-A2S) For the A4S adapter board option, add suffi x “A4S” to the model number (i.e. MI2024S-12ERU-A4S) Pin Function
1 Control
2 GND
5 Trim
Weight: 1.237 Oz (35g) Weight: 1.903 Oz (54g) Notes:
- All dimensions are typical in inches (mm)
- Wire Range: 24 - 12 AWG
- Tolerance x.xx = ±0.02 (±0.50)
We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com www.micropowerdirect.com Mechanical Dimensions: With Heatsink & A2S Adapter Board Mechanical Dimensions: With Heatsink & A4S Adapter Board Pin Function For the A2S adapter board option, add suffi x “A2S” to the model number (i.e. MI2024S-12ERU-HA2S) For the A4S adapter board option, add suffi x “A4S” to the model number (i.e. MI2024S-12ERU-HA4S) Pin Function Weight: 1.414 Oz (40g) Weight: 2.086 Oz (59g) Notes:
- All dimensions are typical in inches (mm)
- Wire Range: 24 - 12 AWG
- Tolerance x.xx = ±0.02 (±0.50)