Oct.2000.Rev.0.3 MITSUBISHI ELECTRIC 2.5" Flash Drive Connector Type IDE ATA 44-pin MF6128M-02BJxx MF6256M-02BJxx MF6512M-02BJxx MF6640M-02BJxx MF601G2-02BJxx
DESCRIPTION
Mitsubishi’s Flash Drives provide large memory capacities on a device approximately the size of a 2.5 ” IDE Type Hard Disk (101.85mm(L) × 69.85mm (W) × 8.47mm (T)). Available in 128MB, 256MB, 512MB, 640MB and 1.2GB capacities.
FEATURES
- 2.5”, IDE ATA 44-pin
- Single 5V Supply
- Up to 1.2GB maximum
- Nonvolatile, No Batteries Required
- High reliability based on internal ECC function
- Fast read/write performance Read: 5MB/s(max.) Write: 128MB card = 2.0MB/s(max.) The others = 3.0MB/ s(max.)
- Multiword DMA commands supported.
- 100,000 program/erase cycles
APPLICATIONS
- Computers
- Data Communication
- Office Automation
- Industrial
- Consumer PRODUCT LIST Memory capacity (Bytes) Data Bus width(bits) Memory Cylinder Head Sector Out line MF6128M-02AJxx 128,057,344 256Mbit Flash x 4 977 8 32 MF6256M-02AJxx 257,163,264 256Mbit Flash x 8 981 16 32 2.5" MF6512M-02AJxx 515,579,904 8/16 256Mbit Flash x 16 999 16 63 IDE MF6640M-02AJxx 640,475,136 256Mbit Flash x 20 1241 16 63 MF601G2-02AJxx 1,219,534,848 256Mbit Flash x 40 2363 16 63
Oct.2000. Rev. 0.3 MITSUBISHI ELECTRIC PIN ASSIGNMENT Pin Signal I/O Pin Signal I/O
1 RESET# I 2 GND -
3 DD7 I/O 4 DD8 I/O
5 DD6 I/O 6 DD9 I/O
7 DD5 I/O 8 DD10 I/O
9 DD4 I/O 10 DD11 I/O
11 DD3 I/O 12 DD12 I/O
13 DD2 I/O 14 DD13 I/O
15 DD1 I/O 16 DD14 I/O
17 DD0 I/O 18 DD15 I/O
19 GND - 20 (keypin) -
21 DMARQ O 22 GND -
23 DIOW# I 24 GND -
25 RIOR# I 26 GND -
27 IORDY O 28 CSEL I
29 DMACK# I 30 GND -
31 INTRQ O 32 IOCS16# O
33 DA1 I 34 PDIAG# I/O
35 DA0 I 36 DA2 I
37 CS0# I 38 CS1# I
39 DASP# I/O 40 GND -
41 VDD - 42 VDD -
43 GND - 44 GND -
Oct.2000. Rev. 0.3 MITSUBISHI ELECTRIC Master/Slave/Cable Select Configuration (1) Master(or single) [Default] If all of pins A, B, C, D are Open, the drive is a Master. 43 1 C A 44 20 2 D B (2) Slave If pins C, D are open and jumper position A-B is used, the drive is a Slave. 43 1 C A 44 20 2 D B (3) Cable Select [Default] If jumper position D-B is used and pins C, A is open, Master/Slave setting is determined by the condition of CSEL signal from the host. 43 1 C A 44 20 2 D B
Oct.2000. Rev. 0.3 MITSUBISHI ELECTRIC Signal Description Signal Name I/O Pin No. Description Address bus[DA2-DA0] I 36, 33, 35 Signals DA2-DA0 are address bus. DA2 is the MSB and DA0 is the LSB. Data bus[D15-D0] I/O 18, 16, 14, 12, 10, 8, 6, 4, 3, 5, 7, 9, 11, 13, 15, Signals DD15-DD0 are data bus. Chip select[CS0#, CS1#] I 37, 38 CS0# is used to select the Command Block Registers. CS1# is used to select the Control Block Registers. Drive I/O read[DIOR#] I 25 DIOR# is used to read data from the Drive’s I/O space. Drive I/O write[DIOW#] I 23 DIOW# is used to write data to the Drive’s I/O space. DMA acknowledge[DMACK#] I 29 This signal shall be used by the host in response to DMARQ to either acknowledge that data has been accepted, or that data is available. DMA request[DMARQ] O 21 This signal, used for DMA data transfer between host and drive, shall be asserted by the drive when it is ready to transfer data to or from the host. Drive interrupt[INTRQ] O 31 This signal is active high interrupt request to the host. Drive 16-bit I/O[IOCS16#] O 32 This output signal is asserted when the I/O port address is capable of 16-bit access. Drive active/drive1 present[DASP#] I/O 39 This signal is the DISK Active/Slave Present signal in the Master/Slave handshake protocol. Drive reset[RESET#] I 1 This input pin is the active low hardware reset from the host. I/O channel ready[IORDY] O 27 This signal is asserted to delay completion of the memory or I/O access cycle. Passed diagnostics[PDIAG#] I/O 34 This signal is the Pass Diagnostic signal in the Master/Slave handshake protocol. Cable select[CSEL] I 28 This signal is used to configure this Drive as a Master or a Slave. When this signal is grounded, this Drive is configured as a Master. When this signal is Open, this Drive is configure as a Slave. VDD - 41, 42 5V power. GND - 2, 19, 22, 24, 26, 30, 40, 43, Ground.
Oct.2000. Rev. 0.3 MITSUBISHI ELECTRIC BLOCK DIAGRAM VDD GND DA2-DA0 CS0# CS1# DIOR# DIOW# DMACK# DMARQ RESET# DD15-DD0 INTRQ IOCS16# PDIAG# DASP# IORDY CSEL Controller POR# RES# CE# OE# WE# CDE# SC I/O7-I/O0 R/B# XIN XOUT 64Mbit AND Flash Memory (x14) 256Mbit AND Flash Memory (x40) RESET Circuit Resonator Internal VDD
Oct.2000. Rev. 0.3 MITSUBISHI ELECTRIC IDE ATA Interface CS1# CS0# DA2-DA0 Register 1 0 0h Data Register(DD15-DD0) Data Register(DD15-DD0) 1 0 1h Error Register(DD7-DD0) Feature Register(DD7-DD0) 1 0 2h Sector Count Register(DD7-DD0) Sector Count Register(DD7-DD0) 1 0 3h Sector Number Register(DD7-DD0) Sector Number Register(DD7-DD0) 1 0 4h Cylinder Low Register(DD7-DD0) Cylinder Low Register(DD7-DD0) 1 0 5h Cylinder High Register(DD7-DD0) Cylinder High Register(DD7-DD0) 1 0 6h Drive Head Register(DD7-DD0) Drive Head Register(DD7-DD0) 1 0 7h Status Register(DD7-DD0) Command Register(DD7-DD0) 0 1 6h Alt. Status Register(DD7-DD0) Device Control Register(DD7-DD0) 0 1 7h Drive Address Register(DD7-DD0) invalid
Oct.2000. Rev. 0.3 MITSUBISHI ELECTRIC ATA Register Specifications Data Register This register is a 16 bit register which is used to transfer data blocks between the card data buffer and the host. Data may be transferred by either a series of word accesses to the Data register or a series of byte accesses to the Data register. DD15 DD1 DD1 DD1 DD1 DD1 DD9 DD8 Data Word Odd Data Byte DD7 DD6 DD5 DD4 DD3 DD2 DD1 DD0 Data Word Data Byte Error Register This register contains additional information about the source of an error which has occurred in processing of the preceding command. This register should be checked by the host when ERR bit in the Status register is set. The Error register is a read only register. DD7 DD6 DD5 DD4 DD3 DD2 DD1 DD0 BBK UNC 0 IDNF 0 ABRT 0 AMNF Field function BBK This bit is set when a Bad Block is detected in requested ID field. Host can not read/write on data area that is marked as a Bad Block. UNC This bit is set when Uncorrectable error is occurred at reading the card. IDNF The requested sector ID is in error or cannot be found. ABRT This bit is set if the command has been aborted because of the card status condition. (Not ready, Write fault, etc.) or when an invalid command has been issued. AMNF This bit is set in case of a general error. Feature Register This register is written by the host to provide command specific information to the drive regarding features of the drive which the host wish to utilize. The Feature register is a write only register. DD7 DD6 DD5 DD4 DD3 DD2 DD1 DD0 Feature byte Sector Count Register This register is written by the host with the number of sectors or blocks to be processed in the subsequent command. After the command is complete, the host may read this register to obtain the count of sectors left unprocessed by the command. DD7 DD6 DD5 DD4 DD3 DD2 DD1 DD0 Sector Count Sector Number Register This register is written by the host with the starting sector number to be used in the subsequent Cylinder-Head-Sector command. After the command is complete, the host may read the final sector number from this register. When logical block addressing is used, this register is written by the host with bit7 to 0 of the starting logical block number and contains bit7 to 0 of the final logical block number after the command is complete. DD7 DD6 DD5 DD4 DD3 DD2 DD1 DD0 Sector Number Logical Block Number bits A07-A00(LBA Addressing) Cylinder Low Register This register is written by the host with the low-order byte of the starting cylinder address to be used in the subsequent Cylinder-Head-Sector command. After the command is complete, the host may read the low-order byte of the final cylinder number from this register. When logical block addressing is used, this register is written by the host with bits15 to 8 of the starting logical block number and contains bits15 to 8 of the final logical block number after the command complete. DD7 DD6 DD5 DD4 DD3 DD2 DD1 DD0 Cylinder Low Byte Logical Block Number bits A15-A08(LBA Addressing) Cylinder High Register This register is written by the host with the high-order byte of the starting cylinder address to be used in the subsequent Cylinder-Head-Sector command. After the command is complete, the host may read the high-order byte of the final cylinder number from this register. When logical block addressing is used, this register is written by the host with bits 23 to 16 of the starting logical block number and contains bits23 to 16 of the final logical block number after the command is complete. DD7 DD6 DD5 DD4 DD3 DD2 DD1 DD0 Cylinder High Byte Logical Block Number bits A23-A16(LBA Addressing)
Oct.2000. Rev. 0.3 MITSUBISHI ELECTRIC Drive/Head Register The Drive/Head register is used to specify the selected drive of a pair of drives sharing a set of registers. DD7 DD6 DD5 DD4 DD3 DD2 DD1 DD0 X LBA X DRV HS3 HS2 HS1 HS0 LBA27 LBA26 LBA25 LBA2 Field function X Undefined . “0” or “1”. LBA This bit is “0” for CHS addressing and “1” for Logical Block addressing. DRV This bit is number of the drive which the host has selected. When DRV is cleared, Drive0 is selected. When DRV is set, Drive1 is selected. The card is selected to be Drive0 or to be Drive1 using the “Copy” field of the PC Card Socket Copy Register. HS3-0 LBA27-24 HS3-0 of the head number in CHS addressing or LBA27-24 of the Logical Block Number in LBA addressing. Status and Alternate Status Registers The Status register and the Alternate Status register return the card status when read by the host. Reading the Status register clears a pending interrupt request while reading the Alternate Status register does not. The Status register and the Alternate Status register are read only registers. DD7 DD6 DD5 DD4 DD3 DD2 DD1 DD0 BSY DRDY DWF DSC DRQ CORR IDX ERR Field function BSY This bit is set when the card internal operation is executing. When this bit is set to “1”, other bits in this register are invalid. DRDY DRDY indicates whether the card is capable of performing card operations. DWF This bit, if set, indicates a write fault has occurred. DSC This bit is set when the drive seek complete. DRQ This bit is set when the information can be transferred between the host and Data register. CORR This bit is set when a correctable data error has been occurred and the data has been corrected. IDX This bit is always set to “0”. ERR This bit is set when the previous command has ended in some type of error. The error information is set in the other Status register bits or Error register. This bit is cleared by the next command. Command Register The Command register contains the command code being sent to the device. Command execution begins immediately after this register is written. The Command register is a write only register. DD7 DD6 DD5 DD4 DD3 DD2 DD1 DD0 Command Device Control Register This register is used to control the card interrupt request and to issue a soft reset to the card. The Device Control register is a write only register. DD7 DD6 DD5 DD4 DD3 DD2 DD1 DD0 X X X X 1 SRST nIEN 0 Field function X don’t care. 1 This bit is set to “1”. SRST This bit is set to “1” in order to force the card to perform a Command Block Reset operation. This does not change the Card Configuration registers as a Hardware Reset does. The card remains in Reset until this bit is reset to “0”. nIEN This bit is used for enabling IREQ#. When this bit is set to “0”, IREQ# is enabled. When this bit is set to “1”, IREQ# is disabled. 0 This bit is set to “0”. Drive Address Register This register is provided for compatibility with the AT disk drive interface. DD7 DD6 DD5 DD4 DD3 DD2 DD1 DD0 X nWTG nHS3-0 nDS1 nDS0 Field function X This bit is unknown. nWTG This bit is set to “0” when a Flash write operation is in progress, otherwise it is set to “1”. nHS3-0 These bits is the negative value of Head Select bits in Drive/Head register. nDS1 This bit is set to “0” when Slave drive is active and selected. nDS0 This bit is set to “0” when Master drive is active and selected.
Oct.2000. Rev. 0.3 MITSUBISHI ELECTRIC ATA Command Specifications This table summarizes the ATA command set with the paragraphs. Following shows the support commands and command codes which are written in command registers. Command Code FR SC SN CY DR HD Check Power Mode 98h, E5h y Execute Drive Diagnostic 90h y Erase Sector(s) C0h y y y y y Format Track 50h y y y y Identify Drive ECh y Idle 97h, E3h y y Idle Immediate 95h, E1h y Initialize Drive Parameters 91h y y y Read Buffer E4h y Read DMA C8h,C9h y y y y y Read Long Sector 22h, 23h y y y y Read Multiple C4h y y y y y Read Sector(s) 20h, 21h y y y y y Read Verify Sector(s) 40h, 41h y y y y y Recalibrate 1xh y Request Sense 03h y Seek 7xh y y y y Set Features EFh y y y Set Multiple mode C6h y y Set Sleep Mode 99h, E6h y Standby 96h, E2h y Standby Immediate 94h, E0h y Translate Sector 87h y y y y y Wear Level F5h y Write Buffer E8h y Write DMA CAh,CBh y y y y y Write Long Sector 32h, 33h y y y y Write Multiple C5h y y y y y Write Multiple without Erase CDh y y y y y Write Sector(s) 30h, 31h y y y y y Write Sector without Erase 38h y y y y y Write Verify 3Ch y y y y y FR : Feature Register, SC : Sector Count Register, SN : Sector Number Register, CY : Cylinder Low/High Register, DR Drive bit of Drive/Head Register, HD : Head No. of Drive/Head Register,
Oct.2000. Rev. 0.3 MITSUBISHI ELECTRIC Check Power Mode(98h, E5h) This command checks the power mode. Execute Drive Diagnostic(90h) This command performs the internal diagnostic tests implemented by the card. Erase Sector(s)(C0h) This command is used to pre-erase and condition data sectors in advance of a Write without Erase or Write Multiple without Erase command. Format Track(50h) This command writes the desired head and cylinder of the selected drive with a FFh pattern. Identify Drive(ECh) This command enables the host to receive parameter information from the card. (Refer to the Identify Drive Information table.) Idle(97h, E3h) This command causes the card to set BSY, enter the Idle mode, clear BSY and generate an interrupt. If the sector count is non-zero, the automatic power down mode is enabled. If the sector count is zero, the automatic power down mode is disabled. Idle Immediate(95h, E1h) This command causes the card to set BSY, enter the idle mode, clear BSY and generate an interrupt. Initialize Drive Parameters(91h) This command allows the host to alter the number of sectors per track and the number of heads per cylinder. Read Buffer(E4h) This command enables the host to read the current contents of the card’s sector buffer. Read DMA(C8h,C9h) This command enables the host to read the sector data by the Multiword DMA protocol. Read Long Sector(22h, 23h) This command is similar to the Read Sector(s) command except the contents of the Sector Count register are ignored and only one sector is read. The 512 data bytes and 4 ECC bytes are read into the buffer(with no ECC correction) and then transferred to the host. Read Multiple(C4h) This command performs similarly to the Read Sector(s) command. Interrupt are not generated on each sector, but on the transfer of a block which contains the number of sectors defined by a Set Multiple command. Read Sector(s)(20h, 21h) This command transfers data from the card to the host. Data transfer starts at the sector specified by the Cylinder, Head, and Sector Number registers, and proceeds for the number of sectors specified in the Sector Count register. Read Verify Sector(s)(40h, 41h) This command is identical to the Read Sector(s) command, except that DRQ is not asserted, and no data is transferred to the host. Recalibrate(1xh) Although this command is supported for backward compatibility, it has no actual function. The card will always return good status at the completion of this command. Request Sense(03h) This command requests extended error information for the previous command. Seek(7xh) This command is supported for backward compatibility. Although this command has no actual function, it does perform a range check of valid track, and posts an IDNF error if the Head or Cylinder specified are out of bounds. Set Features(EFh) This command is used by the host to establish or select certain features. Set Multiple Mode(C6h) This command enables the card to perform Read and Write Multiple operations and establishes the block count for these commands. This card supports 1 sector block size. Set Sleep Mode(99h, E6h) This command causes the card to set BSY, enter the Sleep mode, clear BSY and generate an interrupt.
Oct.2000. Rev. 0.3 MITSUBISHI ELECTRIC Standby(96h, E2h) This command causes the card to set BSY, enter the Standby mode, clear BSY and generate an interrupt. Standby Immediate(94h, E0h) This command causes the card to set BSY, enter the Standby mode, clear BSY and generate an interrupt. Translate Sector(87h) This command allows the host to know the number of times an user sector has been erased and programmed. This card doesn't support the Hot Count value. Wear Leveling(F5h) Although this command is supported for backward compatibility, it has no actual function. The card will always return good status at the completion of this command. Write Buffer(E8h) This command enables the host to overwrite contents of the card’s sector buffer with any data pattern desired. This command has the same protocol as the Write Sector(s) command and transfers 512 bytes. Write DMA(CAh, CBh) This command enables the host to write sector data by the Multiword DMA protocol. Write Long Sector(32h, 33h) This command is similar to the Write Sector(s) except the contents of the Sector Count register are ignored and only one sector is written. The 512 data bytes and 4 ECC bytes are transferred from the host and then written from the buffer to the flash. Write Multiple(C5h) This command is similar to the Write Sector(s) command. Interrupts are not presented on each sector, but on the transfer of a block which contains the number of sectors defined by Set Multiple command. Write Multiple without Erase(CDh) This command is similar to the Write Multiple command. The sectors should be pre-erased with the Erase Sector command before this command is issued. If the sector is not pre-erased, Write Multiple command operation will occur. Write Sector(s)(30h, 31h) This command transfers data from the host to the card. Data transfer starts at the sector specified by the Cylinder, Head, and Sector Number registers, and proceeds for the number of sectors specified in the Sector Count register. Write Sector without Erase(CDh) This command is similar to the Write Sector(s) command. The sectors should be pre-erased with the Erase Sector command before this command is issued. If the sector is not pre-erased, Write Sector command operation will occur. Write Verify(3Ch) This command is similar to the Write Sector(s) command, except each sector is verified immediately after being written.
Oct.2000. Rev. 0.3 MITSUBISHI ELECTRIC Identify Drive Information Word Address Data Description 0 848Ah General configuration bit-significant information 15 1 Non-rotating disk drive 14 0 Format speed tolerance gap not required 13 0 Track offset option not available 12 0 Data strobe offset option not available 11 0 Rotational speed tolerance is < 0.5% 10 1 Disk transfer rate > 10Mbs 9 0 10Mbs <= Disk transfer rate > 5Mbs 8 0 Disk transfer rate <= 5Mbs 7 1 Removable cartridge drive 6 0 Not a fixed drive 5 0 Spindle motor control option not implemented 4 0 Head switch time > 15us 3 1 Not MFM encoded 2 0 Not soft sectored 1 1 Hard sectored 0 0 Reserved 1 xxxxh Number of Cylinders 2 0000h Reserved 3 000xh Number of Heads 4 0000h Number of unformatted bytes per track 5 0200h Number of unformatted bytes per sector 6 0020h Number of sectors per track 7-8 xxxxh, xxxxh Number of sectors per card (word 7 = MSW, word 8 = LSW) 9 0000h Reserved 10-19 2020h Reserved 20 0001h Buffer type: Single ported, single-sector, w/o read cache 21 0001h Buffer size, in 512 byte increments 22 0004h ECC length used on Read and Write Long command 23-26 xxxxh Firmware revision, 8 ASCII characters 27-46 xxxxh Model number, 40 ASCII characters. 47 0001h Maximum Block Count=1 for Read/write Multiple commands 48 0000h Cannot perform doubleword I/O 49 0300h Capabilities 50 0000h Reserved 51 0200h PIO timing cycle timing mode 2 52 0000h Reserved 53 0003h Words 54-58 are valid(bit0), words 64-70 are valid(bit1). 54 xxxxh Number of Current Cylinders 55 xxxxh Number of Current Heads 56 xxxxh Number of Current Sectors per Track 57 xxxxh LSW of the Current Capacity in Sectors 58 xxxxh MSW of the Current Capacity in Sectors 59 010xh Current Setting for Block Count for R/W Multiple commands 60 xxxxh LSW of the total number of user addressable LBA mode 61 xxxxh MSW of the total number of user addressable LBA mode 62 0000h Reserved 63 0007h Multiword DMA mode2 supported 64 0003h Advanced PIO modes supported 65 0078h Minimum Multiword DMA transfer cycle time (120ns) 66 0078h Manufacturer’s recommended Multiword DMA transfer cycle (120ns) 67 00F0h Minimum PIO transfer cycle time with out flow control (240ns) 68 0078h Minimum PIO transfer cycle time with IORDY (120ns) 69-255 0000h Reserved
Oct.2000. Rev. 0.3 MITSUBISHI ELECTRIC ABSOLUTE MAXIMUM RATINGS Symbol Parameter Conditions Ratings Unit VDD Supply voltage -0.3~6.2 V Vi Input voltage With respect to GND -0.3~VDD+0.3 V Vo Output voltage -0.3~VDD+0.3 V Pd Power dissipation Ta = 25 °C 1.2 W Topr Operating temperature 0~60 °C Tstg Storage temperature -10~80 °C RECOMMENDED OPERATING CONDITIONS Limits Symbol Parameter Min. Typ. Max. Unit VDD(5V) VDD Supply voltage 4.5 5.0 5.5 V GND System ground 0 V VIH High input voltage 0.7VDD VDD V VIL Low input voltage 0 0.8 V DC ELECTRICAL CHARACTERISTICS (Ta=0~60°C, VDD=5V±10%, unless otherwise noted) Limits Symbol Parameter Test Condition Min. Typ. Max. Unit 4.5V 5.5V VOH High output voltage IOH=4mA(4.5V) INTRQ, INPACK#, DASP#, PDIAG# 0.8VDD - V IOH=8mA(4.5V) the other outputs VOL Low output voltage IOL=-4mA(4.5V) INTRQ, INPACK#, DASP#, PDIAG# - 0.4 V IOL=-8mA(4.5V) the other outputs IOZ Output current in off state CS0# = CS1# = VIH DD15-DD0 - ±10 µA ICCR Active supply current (Read) Output open 70 110 mA ICCW Active supply current (Write) 100 140 mA ICCS Standby current (Auto power down) CS0# = CS1# = VDD DD15-DD0 = GND Other inputs = VDD or GND 2.0 4.0 mA ICCD Sleep current (Sleep command) CS0# = CS1# = VDD DD15-DD0 = GND Other inputs = VDD or GND 500 800 µA
Oct.2000. Rev. 0.3 MITSUBISHI ELECTRIC DC ELECTRICAL CHARACTERISTICS(Continued) Limits Symbol Parameter Test Condition Min. Typ. Max. Unit 4.5V 5.5V IIH High input current VIN=VDD -10 +10 µA IIL Low input current VIN=GND CS0#, CS1#, DIOR#, DIOW#, DA2-DA0, DD15-DD0 -10 +10 RESET#, DASP#, PDIAG# -30 -100 µA CSEL -10 -50 CAPACITANCE Limits Symbol Parameter Test Condition Min. Typ. Max. Unit CI Input capacitance VI=GND, Vi=25mVrms, f=1 MHZ, Ta=25°C 45 pF CO Output capacitance VO=GND, Vo=25mVrms, f=1 MHZ, Ta=25°C 45 Note : These parameters are not 100% tested.
Oct.2000. Rev. 0.3 MITSUBISHI ELECTRIC AC ELECTRICAL CHARACTERISTICS PIO READ /WRITE TIMING Limit Symbol Parameter Min Max Unit tsuA(DIOR / DIOW) Address Setup before DIOR# / DIOW# * 25 ns thA(DIOR / DIOW) Address Hold following DIOR# / DIOW# * 10 ns tw(DIOR / DIOW) DIOR# / DIOW# Width Time 70 ns td(DIOR) Data Delay after DIOR# 50 ns th(DIOR) Data Hold following DIOR# 5 ns tsu(DIOW) Data Setup before DIOW# 20 ns th(DIOW) Data Hold after DIOW# 10 ns tdfIOCS16(A) IOCS16# Delay Falling from Address * 35 ns tdrIOCS16(A) IOCS16# Delay Rising from Address * 35 ns The maximum load on IOCS16# are 1 LSTTL with 50 pF total load. * “Address” includes DA2-DA0 and CS0#, CS1#. I/O READ / WRITE TIMING DIAGRAM tsuA(DIOR/DIOW) tw(DIOR/DIOW) thA(DIOR/DIOW) tdr IOCS16(A) td (DIOR) tdf IOCS16(A) IOCS16# DA[2:0] CS0# / CS1# DIOR# / DIOW# READ D[15:0] th (DIOR) VALID tsu(DIOW) th(DIOW) WRITE D[15:0]
Oct.2000. Rev. 0.3 MITSUBISHI ELECTRIC Multiword DMA TIMING Limit Symbol Parameter Min Max Unit tsuCS(DIOR / DIOW) CS0#, CS1# Setup before DIOR# / DIOW# 25 ns thCS(DIOR / DIOW) CS0#, CS1# Hold following DIOR# / DIOW# 10 ns tw(DIOR / DIOW) DIOR# / DIOW# Width Time 70 ns tnw(DIOR / DIOW) DIOR# / DIOW# negate pulse Width Time 35 ns tcycle(DIOR / DIOW) DIOR# / DIOW# Cycle Time 120 ns td(DIOR) Data Delay after DIOR# 50 ns th(DIOR) Data Hold following DIOR# 5 ns tsu(DIOW) Data Setup before DIOW# 20 ns th(DIOW) Data Hold after DIOW# 10 ns tsuDMACK(DIOR / DIOW) DMACK# Setup Time before DIOR# / DIOW# 0 ns thDMACK(DIOR / DIOW) DMACK# Hold Time following DIOR# / DIOW# 5 ns tdDMARQ(DIOR / DIOW) DMARQ negate delay time from DIOR# / DIOW# 35 ns Multiword DMA TIMING DIAGRAM tdDMARQ(DIOR/DIOW) tsuDMACK(DIOR/DIOW) tsuCS(DIOR/DIOW) tw(DIOR/DIOW) thCS(DIOR/DIOW) td (DIOR) CS0# / CS1# DIOR# / DIOW# READ D[15:0] th (DIOR) VALID WRITE D[15:0] th (DIOW) tsu(DIOW) DMACK# DMARQ thDMACK(DIOR/DIOW)tnw(DIOR/DIOW) tcycle(DIOR/DIOW)
Oct.2000. Rev. 0.3 MITSUBISHI ELECTRIC RECOMMENDED POWER UP/DOWN CONDITIONS (Ta=0~60°C, unless otherwise noted) Limits Symbol Parameter Conditions Min. Typ. Max. Unit 0V≤ VDD <2V 0 VDD V Vi(CS) CS input voltage 2V≤ VDD <VIH VDD-0.1 VDD VDD+0.1 V VIH ≤ VDD VIH VDD+0.1 V tsu(VDD) CS setup time 20 ms tsu(RESET#) RESET# setup time 20 ms trec(VDD) CS recover time 1 µs tpr VDD rising time 10%à90% of VDD 0.1 100 ms tpf VDD falling time 90% of VDDà10% 3 300 ms tw(RESET#) RESET# width 10 µs th(Hi-zRESET#) 1 ms ts(Hi-zRESET#) 0 ms POWER UP/DOWN TIMING DIAGRAM th(Hi-z RESET#) tpr VDD @ 90% VIH tsu(VDD) tsu(RESET#) VDD @ 10% 2V tsu (RESET#) tw(RESET#) Hi-z tw(RESET#) Hi-z VDD VDD @ 10% VDD @ 90% VIH tpf CS0#, CS1# ts(Hi-z RESET#) RESET# VDD CS0#, CS1# trec(VDD) RESET#
Oct.2000. Rev. 0.3 MITSUBISHI ELECTRIC
- These materials are intended as a reference to assist our customers in the selection of the Mitsubishi semiconductor product best suited to the customer’s application; they do not convey any license under any intellectual property rights, or any other rights, belonging to Mitsubishi Electric Corporation or a third party.
- Mitsubishi Electric Corporation assumes no responsibility for any damage, or infringement of any third-party’s rights, originating in the use of any product data, diagrams, charts, programs, algorithms, or circuit application examples contained in these materials.
- All information contained in these materials, including product data, diagrams, charts, programs and algorithms represents information on products at the time of publication of these materials, and are subject to change by Mitsubishi Electric Corporation without notice due to product improvements or other reasons. It is therefore recommended that customers contact Mitsubishi Electric Corporation or an authorized Mitsubishi Semiconductor product distributor for the latest product information before purchasing a product listed herein. The information described here may contain technical inaccuracies or typographical errors. Mitsubishi Electric Corporation assumes no responsibility for any damage, liability, or other loss rising from these inaccuracies or errors. Please also pay attention to information published by Mitsubishi Electric Corporation by various means, including the Mitsubishi Semiconductor home page (http://www.mitsubishichips.com/).
- When using any or all of the information contained in these materials, including product data, diagrams, charts, programs, and algorithms, please be sure to evaluate all information as a total system before making a final decision on the applicability of the information and products. Mitsubishi Electric Corporation assumes no responsibility for any damage, liability or other loss resulting from the information contained herein.
- Mitsubishi Electric Corporation semiconductors are not designed or manufactured for use in a device or system that is used under circumstances in which human life is potentially at stake. Please contact Mitsubishi Electric Corporation or an authorized Mitsubishi Semiconductor product distributor when considering the use of a product contained herein for any specific purposes, such as apparatus or systems for transportation, vehicular, medical, aerospace, nuclear, or undersea repeater use.
- The prior written approval of Mitsubishi Electric Corporation is necessary to reprint or reproduce in whole or in part these materials.
- If these products or technologies are subject to the Japanese export control restrictions, they must be exported under a license from the Japanese government and cannot be imported into a country other than the approved destination. Any diversion or reexport contrary to the export control laws and regulations of Japan and/or the country of destination is prohibited.
- Please contact Mitsubishi Electric Corporation or an authorized Mitsubishi Semiconductor product distributor for further details on these materials or the products contained therein. Notes regarding these materials circuit designs!
- Mitsubishi Electric Corporation puts the maximum effort into making semiconductor products better and more reliable, but there is always the possibility that trouble may occur with them. Trouble with semiconductors may lead to personal injury, fire or property damage. Remember to give due consideration to safety when making your circuit designs, with appropriate measures such as (i) placement of substitutive, auxiliary circuits, (ii) use of non-flammable material or (iii) prevention against any malfunction or mishap. Keep safty first in your circuit designs!