DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
www.micropowerdirect.com MicroPower Direct
292 Page Street
Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com Key Features: 0.5W Output Power Ultra-Miniature SIP Case 35 Standard Models 3,000 VDC Isolation >1.1 MHour MTBF -40°C to +85°C Operation ME05SI High Isolation, 0.5W Ultra-Miniature SIP DC/DC Con vert ers Input Parameter Conditions Min. Typ. Max. Units Input Voltage Range 3.3 VDC Input 2.97 3.3 3.63 VDC 5 VDC Input 4.50 5.0 5.50 12 VDC Input 10.80 12.0 13.20 24 VDC Input 21.60 24.0 26.40 48 VDC Input 43.20 48.0 52.80 Input Refl ected Ripple Current 20 mA P - P Input Filter Internal Capacitor Output Parameter Conditions Min. Typ. Max. Units Output Voltage Accuracy ±3.0 % Line Regulation For VIN Change of 1% ±1.2 % Load Regulation, See Note 1 See Model Selection Guide Ripple & Noise (20 MHz) 100 mV P - P Temperature Coeffi cient ±0.02 %/°C Output Short Circuit Momentary (0.5 Sec.) General Parameter Conditions Min. Typ. Max. Units Isolation Voltage 60 Seconds 3,000 VDC Isolation Resistance 1,000 M Isolation Capacitance 60 pF Switching Frequency 80 kHz EMI Characteristics Parameter Standard Criteria Level Radiated Emissions EN 55022 Class B Conducted Emissions See Note 3 EN 55022 Class B ESD EN 61000-4-2 A ±8 kV/±6 kV RS EN 61000-4-3 A 10V/m EFT See Note 3 EN 61000-4-4 A ±2 kV Surge See Note 3 EN 61000-4-5 A ±0.5 kV CS EN 61000-4-6 A 10 Vrms PFMF EN 61000-4-8 A 1A/m Environmental Parameter Conditions Min. Typ. Max. Units Operating Temperature Range Ambient -40 +25 +85 °CCase +100 Storage Temperature Range -40 +125 °C Cooling Free Air Convection Humidity RH, Non-condensing 95 % Physical Case Size See Mechanical Diagram (Page 2) Case Material Non-Conductive Black Plastic (UL-94V0) Weight 0.05 Oz (1.5g) Reliability Specifi cations Parameter Conditions Min. Typ. Max. Units MTBF MIL HDBK 217F , 25°C, Gnd Benign 1.121 MHours Absolute Maximum Ratings Parameter Conditions Min. Typ. Max. Units Input Voltage Surge (1 Sec) 3.3 VDC Input 6.0 VDC 5 VDC Input 7.0 12 VDC Input 15.0 24 VDC Input 28.0 48 VDC Input 54.0 Lead Temperature 1.5 mm From Case For 10 Sec 260 °C Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. Series www.micropowerdirect.comwww.micropowerdirect.com Electrical Specifi cations Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice.
www.micropowerdirect.com MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com Model Selection Guide Notes: All dimensions are typical in inches (mm) Tolerance x.xx = ±0.02 (±0.50) Pin 1 is marked by a “dot” or indentation on the front of the unit Model Number Input Output Load Regulation (% Typ) Effi ciency (%, Typ) Capacitive Load (µF, Max) Fuse Rating Slow-Blow (mA) Voltage (VDC) Current (mA) Voltage (VDC) Current (mA, Max)Nominal Range Full-Load No-Load ME0512S-03I 12 10.8 - 13.2 58 15 3.3 152.0 ±20 72 100 150 ME0512S-05I 12 10.8 - 13.2 54 10 5.0 100.0 ±10 78 100 150 ME0512S-09I 12 10.8 - 13.2 57 15 9.0 56.0 ±10 73 100 150 ME0512S-12I 12 10.8 - 13.2 58 20 12.0 42.0 ±10 72 100 150 ME0512S-15I 12 10.8 - 13.2 61 20 15.0 33.0 ±10 69 100 150 ME0512S-18I 12 10.8 - 13.2 61 15 18.0 28.0 ±10 68 100 150 ME0512S-24I 12 10.8 - 13.2 59 15 24.0 21.0 ±10 71 100 150 ME0524S-03I 24 21.6 - 26.4 31 8 3.3 152.0 ±20 69 100 75 ME0524S-05I 24 21.6 - 26.4 29 8 5.0 100.0 ±10 73 100 75 ME0524S-09I 24 21.6 - 26.4 30 10 9.0 56.0 ±10 71 100 75 ME0524S-12I 24 21.6 - 26.4 30 8 12.0 42.0 ±10 71 100 75 ME0524S-15I 24 21.6 - 26.4 29 10 15.0 33.0 ±10 73 100 75 ME0524S-18I 24 21.6 - 26.4 29 10 18.0 28.0 ±10 73 100 75 ME0524S-24I 24 21.6 - 26.4 29 10 24.0 21.0 ±10 72 100 75 ME0548S-03I 48 43.2 - 52.8 17 6 3.3 152.0 ±20 60 100 50 ME0548S-05I 48 43.2 - 52.8 16 6 5.0 100.0 ±10 66 100 50 ME0548S-09I 48 43.2 - 52.8 17 6 9.0 56.0 ±10 62 100 50 ME0548S-12I 48 43.2 - 52.8 17 6 12.0 42.0 ±10 64 100 50 ME0548S-15I 48 43.2 - 52.8 17 6 15.0 33.0 ±10 62 100 50 ME0548S-18I 48 43.2 - 52.8 17 6 18.0 28.0 ±10 62 100 50 ME0548S-24I 48 43.2 - 52.8 18 10 24.0 21.0 ±10 61 100 50 Notes: 1. Output load regulation is specifi ed for a load change of 20% to 100%. 2. Operation at no-load will not damage these units. However, they may not meet all specifi cations. 3. These converters will operate without external components. However, to meet the specifi ed EMI limits, a simple external input fi lter is required. See the input fi lter note below for more information. 4. All units are rated for operation at full output power to +85° C. Operation over +85°C without airfl ow is not recommended. Output power should be derated linearly from 100% at 85° C to 0% at 100°C. 5. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection table above for the correct rating. VIN (VDC) (µF) (µH) (µF) (pF) 3.3 2.2 18.0 5.0 2.2 18.0 12 2.2 18.0 24 2.2 18.0 2.2 470 48 10.0 18.0 2.2 470 Mechanical Dimensions Pin Description 1- V IN 2+ V IN 3- V OUT 4+ V OUT Pin Connections Input Filter For 48VDC input models the width of the unit is 0.29 (7.5) and the pins are set 0.08 (2.0) from the edge of the case. These dimensions are identifi ed with an “*” on the mechanical drawing The filter (C 1, C 2, C3 & L 1) shown in the figure above is required to meet EN 55022 level B. Recommended component values are shown in the table at right. Capacitor C 1 is a 1210, 100V/ceramic, except for the 48V input which is a 100V/electrolytic. Capacitor C 2 is a 1210 100V/ceramic. Capacitor C3 is a 1206 2 kV/ceramic. To meet the requirements of EN 61000-4-4 and EN 61000-4-5, the value of capacitor C1 should be changed to 470 µF/100V. All components should be mounted as close to the unit as possible.