www.micropowerdirect.com MicroPower Direct

292 Page Street

Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com Key Features:  50W Output Power  4:1 Input Voltage Range  1,500 VDC Isolation  Very High Effi ciency  Compact 1 x 2 Inch Case  Ten Standard Models  Remote ON/OFF Control  Industry Standard Pin-Out MB5000RU Compact, 1 x 2 Inch 50W, 4:1 Input Range DC/DC Con vert ers Series Electrical Specifi cations Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice. Input Parameter Conditions Min. Typ. Max. Units Input Start Voltage 24 VDC Input 9.0 VDC48 VDC Input 18.0 Input Shutdown Voltage 24 VDC Input 7.5 VDC48 VDC Input 16.0 Start-Up Time, See Note 1 Nominal VIN, Constant Resistive Load 30 mS Input Filter LC Filter Output Parameter Conditions Min. Typ. Max. Units Output Voltage Accuracy ±1.0 % Line Regulation VIN = Min to Max ±0.5 % Load Regulation, See Note 2 ±0.5 % Ripple & Noise, See Note 3 3.3 & 5.0 VOUT Models 100 mV P - P12, 15 & 24 VOUT Models 150 Transient Recovery Time, See Note 4 25% Load Step Change 250 µSec Transient Response Deviation ±3.0 ±5.0 % Temperature Coeffi cient ±0.02 %/°C Output Power Protection Hiccup Mode 150 % Over Temperature Protection Shutdown Temperature +110 °C Output Short Circuit, See Note 5 Continuous (Autorecovery) General Parameter Conditions Min. Typ. Max. Units Isolation Voltage 60 Seconds 1,500 VDC Isolation Resistance 500 VDC 1,000 M/H9024 Isolation Capacitance 100 kHz, 1V 2,200 pF Switching Frequency 285 kHz Environmental Parameter Conditions Min. Typ. Max. Units Operating Temperature Range, Ambient Without Heatsink

3.3 VOUT Models

-40 +25 +61 °C12, & 15 VOUT Models +53 5.0 & 24 VOUT Models +46 Operating Temperature Range, Ambient With Heatsink -40 +25 +69 °C12, & 15 VOUT Models +62 5.0 & 24 VOUT Models +57 Operating Temperature Range Case +105 °C Storage Temperature Range -50 +125 °C Cooling Free Air Convection Humidity RH, Non-condensing 95 % Physical Case Material Metal with Non-Conductive Base Weight 1.20 Oz (34g) Reliability Specifi cations Parameter Conditions Min. Typ. Max. Units MTBF MIL HDBK 217F , 25°C, Gnd Benign 233.5 kHours Absolute Maximum Ratings Parameter Conditions Min. Typ. Max. Units Input Voltage Surge (1 Sec) 24 VDC Input -0.7 50.0 VDC48 VDC Input -0.7 100.0 Lead Temperature 1.5 mm From Case For 10 Sec 260.0 °C Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.

292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com www.micropowerdirect.comModel Selection Guide Notes: 1. Start up time is measured at nominal input and with a constant resistive load. 2. Load regulation is specifi ed for a load change of minimum load to full load. 3. When measuring output ripple, it is recommended that an external 1 µF capacitor and 10 µF capacitor be connected in parallel from the +V OUT to the -VOUT pins. 4. Transient recovery is measured to within a 1% error band for a load step change of 25%. 5. Short circuit protection is provided by a “hiccup mode” circuit. 6. Operation at no-load will not damage the unit. 7. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selec- tion table above for the correct rating. An external resister may be added to adjust the converter output. To adjust the output UP , connect a 5%, 3W resistor between the minus output pin (5) and the Vout trim pin (6). To adjust the output DOWN, connect a 5%, 3W resistor between the plus output pin (4) and the Vout trim pin (6). The trim table at right gives suggested resistor values for this adjustment. External Trim Remote On/Off MB50xxS-03RU Trim Down Trim Up Vout V MB50xxS-05RU Trim Down Trim Up Vout V MB50xxS-12RU Trim Down Trim Up MB50xxS-15RU Trim Down Trim Up Vout V MB50xxS-24RU Trim Down Trim Up Vout V Applying a signal to pin 3 will turn the unit ON/OFF . If the pin is left open, the unit operates. If grounded, the unit will shut off. The specifi cations for the ON/OFF function are: Parameter Min Typ Max Units Supply On 3.5 12.0 VDC Supply Off 0.0 1.2 VDC Standby Input Current 2.5 mA Control Common Referenced to Negative Input (pin 2) Control Input Current (ON) 0.5 mA Control Input Current (OFF) -0.5 mA Model Number Input Refl ected Ripple Current (mA, Typ) Output Over Voltage Protection (VDC) Effi ciency (%, Typ) Capacitive Load (µF Max) Fuse Rating Slow-Blow (A) Voltage (VDC) Current (mA) Voltage (VDC) Current (mA, Max) Current (mA, Min)Nominal Range Full-Load No-Load For heatsink option, add suffi x “H” to model number (i.e. MB5024S-03RU-H)

MicroPower Direct • 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com www.micropowerdirect.com MB50xxS-03RU Without Heatsink MB50xxS-03RU With Heatsink MB50xxS-12RU, -15RU Without Heatsink MB50xxS-12RU, -15RU With Heatsink MB50xxS-05RU, -24RU Without Heatsink MB50xxS-05RU, -24RU With Heatsink Derating Curves www.micropower direct.com www.micropowerdirect.com External Component Connection EMC Specifi cations Parameter Standard Radiated Emissions EN 55022 Class A/B Conducted Emissions EN 55022 Class A/B ESD EN 61000-4-2 Criteria B; ±8 kV Air, ±6 kV Contact RS EN 61000-4-3 Criteria A; 10V/m EFT, See Notes EN 61000-4-4 Criteria A; ±2 kV Surge, See Notes EN 61000-4-5 Criteria A; ±1 kV CS EN 61000-4-6 Criteria A; 10 V/m Notes: All units should meet EN 55022 (CE/RE) class A/B with the simple external circuit shown at right. To meet the requirements of EN 61000-4-4 and EN 61000-4-5, the value of C 1 should be changed to 220 µF/100V. Contact the factory for more information. Standard Model C1 C2 L1 L2 C3 C4 C5 EN55022 Class A MB5024S-xxRU 10 µF/50V 1210 X7S --- 1.5 µH --- --- --- 1,000 pF/2kV 1206 MLCC MB5048S-xxRU 3.3 µF/100V 1210 X7S --- 6.8 µH --- --- --- 1,000 pF/2kV 1206 MLCC EN55022 Class B MB5024S-xxRU 3.3 µF/100V 1210/X7S 3.3 µF/100V 1210/X7S --- 1 mH 3.3 µF/100V 1210/X7S 1,200 pF/2kV 1808 X7R 1,200 pF/2kV 1808 X7R MB5048S-xxRU 3.3 µF/100V 1210/X7S 3.3 µF/100V 1210/X7S --- 1 mH 3.3 µF/100V 1210/X7S 1,200 pF/2kV 1808 X7R 1,200 pF/2kV 1808 X7R

We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com www.micropowerdirect.com MicroPower Direct We Power Your Success - For Less !We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com Notes:

  • All dimensions are typical in inches (mm)
  • Tolerance x.xx = ±0.02 (±0.50)
  • Heatsink is black, anodized aluminum Mechanical Dimensions Mechanical Dimensions: With Optional Heatsink Pin Single Output 1+ V i n 2- V i n

3 Remote On/Off

6 Trim

For the heatsink option, add suffi x “H” to the model number (i.e. MB5048S-24RU-H)