Key Features: 50W Output Power 2:1 Input Voltage Range 1,500 VDC Isolation 15 Standard Models Effi ciency to 92% Compact 1 x 2 Inch Case Wide Temp Operation Industry Standard Pin-Out Low Cost MB5000RW Compact, 1 x 2 Inch 50W, 2:1 Input Range DC/DC Con vert ers Electrical Specifi cations Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice. www.micropowerdirect.com MicroPower Direct
292 Page Street
Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com Series Input Parameter Conditions Min. Typ. Max. Units Input Start Voltage 12 VDC Input 9.0 VDC24 VDC Input 18.0 48 VDC Input 36.0 Input Shutdown Voltage 12 VDC Input 8.3 VDC24 VDC Input 16.5 48 VDC Input 33.0 Input Filter LC Filter Start-Up Time See Note 1 30 mS Output Parameter Conditions Min. Typ. Max. Units Output Voltage Accuracy ±1.0 % Line Regulation VIN = Min to Max ±0.5 % Load Regulation Min Load to Full Load ±0.5 % Ripple & Noise, See Note 2 3.3 & 5.0 Vout Models 100 mV P - P 12, 15 & 24 Vout Models 150 mV P - P Transient Recovery Time, See Note 3 25% Load Step Change 250 µSec Transient Response Deviation ±3.0 ±5.0 % Temperature Coeffi cient ±0.02 %/°C Over Temperature Protection Shutdown Temperature 110 °C Output Power Protection 150 % Output Short Circuit, See Note 4 Continuous (Autorecovery) General Parameter Conditions Min. Typ. Max. Units Isolation Voltage 60 Seconds 1,500 VDC Isolation Resistance 500 VDC 1,000 M/H9024 Isolation Capacitance 100 kHz, 1V 2,200 pF Switching Frequency See Note 5 320 kHz Environmental Parameter Conditions Min. Typ. Max. Units Operating Temperature Range, Ambient Without Heatsink MB50xxS-03RW -40 +25 +56 MB5024S-05RW, -12RW, -15RW MB5048S-05RW, -12RW, -15RW +53 MB5012S-12RW, -15RW, -24RW MB5024S-24RW, MB5048S-24RW +46 MB5012S-05RW +38 Operating Temperature Range, Ambient With Heatsink MB50xxS-03RW -40 +25 +64 MB5024S-05RW, -12RW, -15RW MB5048S-05RW, -12RW, -15RW +62 MB5012S-12RW, -15RW, -24RW MB5024S-24RW, MB5048S-24RW +56 MB5012S-05RW +49 Operating Temperature Range Case +105 °C Storage Temperature Range -50 +125 °C Cooling Free Air Convection Humidity RH, Non-condensing 95 % Physical Case Material Metal with Non-Conductive Base Weight 1.06 Oz (30g) Reliability Specifi cations Parameter Conditions Min. Typ. Max. Units MTBF MIL HDBK 217F , 25°C, Gnd Benign 224.7 kHours Absolute Maximum Ratings Parameter Conditions Min. Typ. Max. Units Input Voltage Surge (1 Sec) 12 VDC Input -0.7 25.0 VDC24 VDC Input -0.7 50.0 48 VDC Input -0.7 100.0 Lead Temperature 1.5 mm From Case For 10 Sec 260.0 °C Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com www.micropowerdirect.com Notes: 1. Start up time is measured at nominal input and with a constant resistive load. 2. When measuring output ripple, it is recommended that an external 1 µF capacitor and 10 µF capacitor be connected in parallel from the +V OUT to the -VOUT pins. 3. Transient recovery is measured to within a 1% error band for a load step change of 25%. 4. Short circuit protection is provided by a “hiccup mode” circuit. 5. The switching frequency for 24 VDC output models is 285 kHz. 6. Operation at no-load will not damage these units. 7. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection table above for the correct rating. An external resister may be added to adjust the converter output. To adjust the output UP , connect a 5%, 3W resistor between the minus output pin (5) and the Vout trim pin (6). To adjust the output DOWN, connect a 5%, 3W resistor between the plus output pin (4) and the Vout trim pin (6). The trim table at right gives suggested resistor values for this adjustment. External Trim For heatsink option, add suffi x “H” to model number (i.e. MB5012S-05RW-H) Model Number Input Output Effi ciency (%, Typ) Over Voltage Protection (VDC) Capacitive Load (µF Max) Fuse Rating Slow-Blow (A) Voltage (VDC) Current (mA) Voltage (VDC) Current (mA, Max) Current (mA, Min)Nominal Range Full-Load No-Load MB50xxS-03RW Trim Down Trim Up Vout V MB50xxS-05RW Trim Down Trim Up Vout V MB50xxS-12RW Trim Down Trim Up Vout V MB50xxS-15RW Trim Down Trim Up Vout V MB50xxS-24RW Trim Down Trim Up Vout V
MicroPower Direct • 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com MB50xxS-03RW Without Heatsink MB50xxS-03RW With Heatsink MB5024/48S-05RW, -12RW, -15RW Without Heatsink MB5024/48S-05RW, -12RW, -15RW With Heatsink MB5012S-12RW, 15RW & MB50xxS-24RW Without Heatsink MB5012S-12RW, 15RW & MB50xxS-24RW With Heatsink MB5012S-05RW Without Heatsink MB5012S-05RW With Heatsink Derating Curves www.micropowerdirect.com Parameter Standard Radiated Emissions EN 55022 Class A/B Conducted Emissions EN 55022 Class A/B ESD EN 61000-4-2 Criteria B; ±8 kV Air, ±6 kV Contact RS EN 61000-4-3 Criteria A; 10V/m EFT, See Notes EN 61000-4-4 Criteria A; ±2 kV Surge, See Notes EN 61000-4-5 Criteria A; ±1 kV CS EN 61000-4-6 Criteria A; 10 V/m All units should meet EN 55022 (CE/RE) class A/B with the simple external circuit shown; using the component values given in the table. To meet the requirements of EN 61000-4-4 and EN 61000-4-5, the value of C 1 should be changed to 330 µ F/200V. Contact the factory for more information. Standard Model C1 C2 L1 C3 C4 EN55022 Class A MB5012x-xxRW 22 µF/25V 1210 MLCC --- --- --- --- MB5024x-xxRW 3.3 µF/50V 1210 MLCC --- --- --- --- MB5048x-xxRW 2.2 µF/100V 1210 MLCC --- --- --- --- EN55022 Class B MB50xxS-xxRW 3.3 µF/100V 1210/X7S 3.3 µF/100V 1210/X7S 1 mH 1,000 pF/2kV 1808 X7R 1,000 pF/2kV 1808 X7R EMC Specifi cations
We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com www.micropowerdirect.com Notes:
- All dimensions are typical in inches (mm)
- Tolerance x.xx = ±0.02 (±0.50)
- Heatsink is black, anodized aluminum Mechanical Dimensions Not Mechanical Dimensions: With Optional Heatsink Pin Function 1+ V i n 2- V i n
3 Remote On/Off
6 Trim
For the heatsink option, add suffi x “H” to the model number (i.e. MB5048S-12RW-H) Parameter Min Typ Max Units Supply On 3.5 12.0 VDC Supply Off 0.0 1.2 VDC Standby Input Current 2.5 mA Control Common Referenced to Negative Input (pin 2) Control Input Current (ON) 0.5 mA Contr ol Input Current (OFF) -0.5 mA Remote On/Off Applying a signal to pin 3 will turn the unit ON/OFF. If the pin is left open, the unit operates. If grounded, the unit will shut off. The specifi cations for the ON/OFF function are given in the table at left.