Key Features: 40W Output Power 2:1 Input Voltage Range 1,500 VDC Isolation Single & Dual Outputs Effi ciency to 91% Compact 1 x 2 Inch Case Wide Temp Operation Industry Standard Pin-Out Low Cost MB4000RW Compact, 1 x 2 Inch 40W, 2:1 Input Range DC/DC Con vert ers Electrical Specifi cations Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice. www.micropowerdirect.com MicroPower Direct
292 Page Street
Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com Series Input Parameter Conditions Min. Typ. Max. Units Input Start Voltage 12 VDC Input 9.0 VDC24 VDC Input 18.0 48 VDC Input 36.0 Input Shutdown Voltage 12 VDC Input 8.3 VDC24 VDC Input 16.5 48 VDC Input 33.0 Input Filter LC Filter Start-Up Time See Note 1 30 mS Output Parameter Conditions Min. Typ. Max. Units Output Voltage Accuracy ±1.0 % Output Voltage Balance Dual Output , Balanced Loads ±2.0 % Line Regulation VIN = Min to Max ±0.5 % Load Regulation, Min Load to Full Load Single Output Models ±0.5 %Dual Output Models ±1.0 Cross Regulation See Note 2 ±5.0 % Ripple & Noise, See Note 3 3.3 & 5.0 Vout Models 100 mV P - P 12, 15 & 24 Vout Models 150 mV P - P Dual Output Models 150 mV P - P Transient Recovery Time, See Note 4 25% Load Step Change 250 µSec Transient Response Deviation ±3.0 ±5.0 % Temperature Coeffi cient ±0.02 %/°C Over Temperature Protection Shutdown Temperature 110 °C Output Power Protection 150 % Output Short Circuit, See Note 5 Continuous (Autorecovery) General Parameter Conditions Min. Typ. Max. Units Isolation Voltage 60 Seconds 1,500 VDC Isolation Resistance 500 VDC 1,000 M/H9024 Isolation Capacitance 100 kHz, 1V 1,500 pF Switching Frequency See Note 6 320 kHz Environmental Parameter Conditions Min. Typ. Max. Units Operating Temperature Range, Ambient Without Heatsink MB40xxS-03RW -40 +25 +66 °CMB40xxS-05RW, -12RW, -15RW, -24RW +46 MB40xxD-xxRW +40 Operating Temperature Range, Ambient With Heatsink MB40xxS-03RW -40 +25 +73 °CMB40xxS-05RW, -12RW, -15RW, -24RW +57 MB40xxD-xxRW +52 Operating Temperature Range Case +105 °C Storage Temperature Range -50 +125 °C Cooling Free Air Convection Humidity RH, Non-condensing 95 % Physical Case Material Metal with Non-Conductive Base Weight 1.06 Oz (30g) Reliability Specifi cations Parameter Conditions Min. Typ. Max. Units MTBF MIL HDBK 217F , 25°C, Gnd Benign 328 kHours Absolute Maximum Ratings Parameter Conditions Min. Typ. Max. Units Input Voltage Surge (1 Sec) 12 VDC Input -0.7 25.0 VDC24 VDC Input -0.7 50.0 48 VDC Input -0.7 100.0 Lead Temperature 1.5 mm From Case For 10 Sec 260.0 °C Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com www.micropowerdirect.com Notes: 1. Start up time is measured at nominal input and with a constant resistive load. 2. Cross regulation is measured with the output being tested at 100% load. The second output is varied from 25% to 100% load. 3. When measuring output ripple, it is recommended that an external 1 µF capacitor and 10 µF capacitor be connected in parallel from the +V OUT to the -VOUT pins for single output units and from each output to common for dual output units. 4. Transient recovery is measured to within a 1% error band for a load step change of 25%. 5. Short circuit protection is provided by a “hiccup mode” circuit. 6. The switching frequency for 24 VDC output models is 285 kHz. 7. Operation at no-load will not damage these units. However, they may not meet all specifi cations if operated below the specifi ed minimum load. 8. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection table above for the correct rating. On single output units, an external resister may be added to adjust the converter output. To adjust the output UP , connect a 5%, 3W resistor between the minus output pin (5) and the Vout trim pin (6). To adjust the output DOWN, connect a 5%, 3W resistor between the plus output pin (4) and the Vout trim pin (6). The trim table at right gives suggested resistor values for this adjustment. External Trim For heatsink option, add suffi x “H” to model number (i.e. MB4012S-05RW-H) Model Number Input Output Effi ciency (%, Typ) Over Voltage Protection (VDC) Capacitive Load (µF Max) Fuse Rating Slow-Blow (A) Voltage (VDC) Current (mA) Voltage (VDC) Current (mA, Max) Current (mA, Min)Nominal Range Full-Load No-Load MB40xxS-03RW Trim Down Trim Up Vout V MB40xxS-05RW Trim Down Trim Up MB40xxS-12RW Trim Down Trim Up MB40xxS-15RW Trim Down Trim Up Vout V MB40xxS-24RW Trim Down Trim Up Vout V
MicroPower Direct • 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com MB40xxS-03RW Without Heatsink MB40xxS-03RW With Heatsink MB40xxS-05RW, -12RW, -15RW, -24RW Without Heatsink MB40xxS-05RW, -12RW, -15RW, -24RW With Heatsink MB40xxD-12RW, MB40xxD-15RW Without Heatsink MB40xxD-12RW, MB40xxD-15RW With Heatsink Derating Curves www.micropowerdirect.com External Component Connection EMC Specifi cations Parameter Standard Radiated Emissions EN 55022 Class A Conducted Emissions EN 55022 Class A ESD EN 61000-4-2 Criteria B; ±8 kV Air, ±6 kV Contact RS EN 61000-4-3 Criteria A; 10V/m EFT, See Notes EN 61000-4-4 Criteria A; ±2 kV Surge, See Notes EN 61000-4-5 Criteria B; ±1 kV CS EN 61000-4-6 Criteria A; 10 V/m Notes: All units should meet EN 55022 (CE/RE) class A/B with the simple external circuit shown at right. To meet the requirements of EN 61000-4-4 and EN 61000-4-5, the value of C 1 should be changed to 330 µF/200V. Contact the factory for more information. Standard Model C1 C2 L1 C3 C4 C5 C6 EN55022 Class A MB4012x-xxRW 10 µF/25V 1812 MLCC --- --- --- --- 1,000 pF/2kV 1808 MLCC 1,000 pF/2kV 1808 MLCC MB4024x-xxRW 4.7 µF/50V 1812 MLCC --- --- --- --- 1,000 pF/2kV 1808 MLCC 1,000 pF/2kV 1808 MLCC MB4048x-xxRW 2.2 µF/100V 1812 MLCC --- --- --- --- 1,000 pF/2kV 1808 MLCC 1,000 pF/2kV 1808 MLCC EN55022 Class B MB40xxS-xxRW 3.3 µF/100V 1210/X7S 3.3 µF/100V 1210/X7S 1 mH 3.3 µF/100V 1210/X7S 3.3 µF/100V 1210/X7S 1,000 pF/2kV 1808 X7R 1,000 pF/2kV 1808 X7R MB40xxD-xxRW 3.3 µF/100V 1210/X7S 3.3 µF/100V 1210/X7S 1 mH 3.3 µF/100V 1210/X7S 3.3 µF/100V 1210/X7S 1,000 pF/2kV 1808 X7R 1,000 pF/2kV 1808 X7R Parameter Min Typ Max Units Supply On 3.5 12.0 VDC Supply Off 0.0 1.2 VDC Standby Input Current 2.5 mA Control Common Referenced to Negative Input (pin 2) Control Input Current (ON) 0.5 mA Contr ol Input Current (OFF) -0.5 mA Remote On/Off Applying a signal to pin 3 will turn the unit ON/OFF. If the pin is left open, the unit operates. If grounded, the unit will shut off. The specifi cations for the ON/OFF function are given in the table at left.
We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com www.micropowerdirect.com Notes:
- All dimensions are typical in inches (mm)
- Tolerance x.xx = ±0.02 (±0.50)
- Heatsink is black, anodized aluminum Mechanical Dimensions Mechanical Dimensions: With Optional Heatsink Pin Single Output 1+ V i n 2- V i n
3 Remote On/Off
6 Trim
5 Common
For the heatsink option, add suffi x “H” to the model number (i.e. MB4048S-24RW-H)