DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

Key Features:  40W Output Power  4:1 Input Voltage Range  1,500 VDC Isolation  Single & Dual Outputs  Effi ciency to 91%  Compact 1 x 2 Inch Case  Wide Temp Operation  Industry Standard Pin-Out  Low Cost MB4000RU Compact, 1 x 2 Inch 40W, 4:1 Input Range DC/DC Con vert ers Input Parameter Conditions Min. Typ. Max. Units Input Start Voltage 24 VDC Input 9.0 VDC48 VDC Input 18.0 Under Voltage Shutdown 24 VDC Input 8.3 VDC48 VDC Input 16.5 Input Filter LC Filter Start-Up Time See Note 1 30 mS Output Parameter Conditions Min. Typ. Max. Units Output Voltage Accuracy ±1.0 % Output Voltage Balance Dual Outputs, Balanced Loads ±2.0 % Output Trim Range ±10 % Line Regulation VIN = Min to Max ±0.5 % Load Regulation, See Note 2 Single Output ±0.5 %Dual Output ±1.0 Cross Regulation See Note 3 ±5.0 % Ripple & Noise (20 MHz), See note 4 3.3 & 5 VOUT Models 100 mV P - P12, 15 & 24 VOUT Models 150 Dual Output Models 150 Transient Recovery Time, See Note 5 25% Load Step Change 250 µSec Transient Response Deviation ±3.0 ±5.0 % Temperature Coeffi cient ±0.02 %/°C Over Temperature Protection Shutdown Temperature 110 °C Output Power Protection 150 % Output Short Circuit, See Note 6 Continuous (Autorecovery) General Parameter Conditions Min. Typ. Max. Units Isolation Voltage 60 Seconds 1,500 VDC Isolation Resistance 500 VDC 1,000 M Isolation Capacitance 100 kHz/1.0V 1,500 pF Switching Frequency See Note 7 320 kHz Environmental Parameter Conditions Min. Typ Max. Units Operating Temperature Range, Ambient Without Heatsink MB40xxS-03RU -40 +25 +66 MB40xxS-05RU, MB4048S-12RU, -15RU +51 MB4024S-12RU, MB4024S-15RU +45 MB40xxS-24RU +57 MB40xxD-xxRU +40 Operating Temperature Range, Ambient With Heatsink MB40xxS-03RU -40 +25 +73 MB40xxS-05RU, MB4048S-12RU, -15RU +61 MB4024S-12RU, MB4024S-15RU +57 MB40xxS-24RU +66 MB40xxD-xxRU +52 Operating Temperature Range Case +105 °C Storage Temperature Range -50 +125 °C Humidity RH, Non-condensing 95 % Physical Case Material Aluminum Alloy With Non-Conductive Base (UL94-V0) Weight 1.06 Oz (30g) Reliability Specifi cations Parameter Conditions Min. Typ. Max. Units MTBF MIL HDBK 217F , 25°C, Gnd Benign 328 kHours Absolute Maximum Ratings Parameter Conditions Min. Typ. Max. Units Input Voltage Surge (1 Sec) 24 VDC Input -0.7 50.0 VDC48 VDC Input -0.7 100.0 Lead Temperature 1.5 mm From Case for 10 Sec 260 °C Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. Electrical Specifi cations Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice. www.micropowerdirect.com MicroPower Direct

292 Page Street

Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com Series

292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com www.micropowerdirect.com Notes: 1. Start up time is measured at nominal input and with a constant resistive load. 2. Load regulation is specifi ed for a load change of minimum load to full load. 3. Cross regulation is measured with the output being tested at 100% load. The second output is varied from 25% to 100% load. 4. When measuring output ripple, it is recommended that an external 1 µF capacitor and 10 µF capacitor be connected in parallel from the +V OUT to the -VOUT pins for single output units and from each output to common for dual output units. 5. Transient recovery is measured to within a 1% error band for a load step change of 25%. 6. Short circuit protection is provided by a “hiccup mode” circuit. 7. The switching frequency for 24 VDC output models is 285 kHz. 8. Operation at no-load will not damage these units. However, they may not meet all specifi cations if operated below the specifi ed minimum load. 9. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection table above for the correct rating. Model Number Input Output Effi ciency (%, Typ) Over Voltage Protection (VDC Typ) Capacitive Load (µF , Max) Fuse Rating Slow-Blow (A) Voltage (VDC) Current (mA) Voltage (VDC) Current (mA, Max) Current (mA, Min)Nominal Range Full-Load No-Load On single output units, an external resister may be added to adjust the converter output. To adjust the output UP , connect a 5%, 3W resistor between the minus output pin (5) and the Vout trim pin (6). To adjust the output DOWN, connect a 5%, 3W resistor between the plus output pin (4) and the Vout trim pin (6). The trim table at right gives suggested resistor values for this adjustment. External Trim Remote On/Off MB40xxS-03RU Trim Down Trim Up Vout V MB40xxS-05RU Trim Down Trim Up Vout V MB40xxS-12RU Trim Down Trim Up MB40xxS-15RU Trim Down Trim Up MB40xxS-24RU Trim Down Trim Up Vout V Applying a signal to pin 3 will turn the unit ON/OFF . If the pin is left open, the unit operates. If grounded, the unit will shut off. The specifi cations for the ON/OFF function are: Parameter Min Typ Max Units Supply On 3.5 12.0 VDC Supply Off 0.0 1.2 VDC Standby Input Current 2.5 mA Control Common Referenced to Negative Input (pin 2) Control Input Current (ON) 0.5 mA Control Input Current (OFF) -0.5 mA For heatsink option, add suffi x “H” to model number (i.e. MB4024S-15RU-H)

MicroPower Direct • 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com MB40xxS-03RU Without Heatsink MB40xxS-03RU With Heatsink MB40xxS-05RU, MB4048S-12RU MB4048S-15RU Without Heatsink MB40xxS-05RU, MB4048S-12RU MB4048S-15RU With Heatsink MB4024S-12RU, MB4024S-15RU Without Heatsink MB4024S-12RU, MB4024S-15RU With Heatsink MB40xxD-12RU, MB40xxD-15RU Without Heatsink MB40xxD-12RU, MB40xxD-15RU With Heatsink MB40xxS-24RU Without Heatsink MB40xxS-24RU With Heatsink Derating Curves www.micropowerdirect.com

We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com www.micropowerdirect.com Notes:

  • All dimensions are typical in inches (mm)
  • Tolerance x.xx = ±0.02 (±0.50)
  • Heatsink is black, anodized aluminum Mechanical Dimensions Mechanical Dimensions: With Optional Heatsink Pin Single Output 1+ V i n 2- V i n

3 Remote On/Off

6 Trim

5 Common

For the heatsink option, add suffi x “H” to the model number (i.e. MB4048D-12RU-H) Parameter Standard Radiated Emissions EN 55022 Class A Conducted Emissions EN 55022 Class A ESD EN 61000-4-2 Criteria B; ±8 kV Air, ±6 kV Contact RS EN 61000-4-3 Criteria A; 10V/m EFT, See Notes EN 61000-4-4 Criteria A; ±2 kV Surge, See Notes EN 61000-4-5 Criteria B; ±1 kV CS EN 61000-4-6 Criteria A; 10 V/m All units should meet EN 55022 (CE/RE) class A/B with the simple external circuit shown; using the component values given in the table. To meet the requirements of EN 61000-4-4 and EN 61000-4-5, the value of C 1 should be changed to 330 µ F/200V. Contact the factory for more information. Standard Model C1 C2 L1 C3 C4 EN55022 Class A MB4024x-xxRU 4.7 µF/50V 1812 MLCC --- --- 1,000 pF/2kV 1808 MLCC 1,000 pF/2kV 1808 MLCC MB4048x-xxRU 2.2 µF/100V 1812 MLCC --- --- 1,000 pF/2kV 1808 MLCC 1,000 pF/2kV 1808 MLCC EN55022 Class B MB40xxx-xxRU 3.3 µF/100V 1210/X7S 3.3 µF/100V 1812 MLCC 700 µH 680 pF/2kV 1808 X7R 680 pF/2kV 1808 X7R MB40xxx-24RU 4.7 µF/100V 1210/X7S 3.3 µF/100V 1812 MLCC 700 µH 1,000 pF/2kV 1808 X7R 1,000 pF/2kV 1808 X7R EMC Specifi cations