DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 6
Technical content
www.micropowerdirect.com MicroPower Direct
292 Page Street
Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com Key Features: 20W Output Power EN 60950 Approval (Pending) 2:1 Input Voltage Range 1,500 VDC Isolation Single & Dual Outputs Effi ciency to 90% Compact 1 x 2 Inch Case -40°C to +85°C Operation Industry Standard Pin-Out Low Cost MB2000ERW Low Cost, 1 x 2 Inch 20W, 2:1 Input Range DC/DC Con vert ers Input Parameter Conditions Min. Typ. Max. Units Input Start Voltage 12 VDC Input 18.0 VDC24 VDC Input 36.0 Input Filter /H9266 (Pi) Filter Start-Up Time See Note 2 10 mS Output Parameter Conditions Min. Typ. Max. Units Output Voltage Accuracy See Note 3 ±1.0 ±3.0 % Output Trim Range ±10 % Line Regulation, VIN = Min to Max Positive Output ±0.2 ±0.5 %Negative Output ±0.5 ±1.0 Load Regulation, IOUT = 5% to 100% Positive Output ±0.5 ±1.0 %Negative Output ±0.5 ±1.5 Cross Regulation See Note 4 ±5.0 % Ripple & Noise (20 MHz) See Note 5 50 100 mV P - P Transient Recovery Time, See Note 6 300 500 µS Temperature Coeffi cient ±0.03 %/°C Over Voltage Protection 110 160 % Output Power Protection 110 190 % Output Short Circuit, See Note 7 Continuous (Autorecovery) General Parameter Conditions Min. Typ. Max. Units Isolation Voltage 60 Seconds 1,500 VDC Isolation Resistance 500 VDC 1,000 M Isolation Capacitance, 100 kHz, 0.1V Model MB2024S-24ERW 2,050 pFAll Other Models 1,050 Switching Frequency 270 kHz Environmental Parameter Conditions Min. Typ. Max. Units Operating Temperature Range Ambient -40 +25 +85 °C Storage Temperature Range -55 +125 °C Cooling Free Air Convection Humidity RH, Non-condensing 95 % Physical Case Size See Mechanical Diagrams (Pages 4,5 & 6) Case Material Aluminum Alloy With Non-Conductive Base (UL94-V0) Weight See Mechanical Diagrams (Pages 4,5 & 6) Remote On/Off Parameter Conditions Min. Typ. Max. Units Unit On See Note 8 3.5 12.0 VDC Unit Off See Note 8 0 1.2 VDC Off Idle Current 4.0 7.0 mA Reliability Specifi cations Parameter Conditions Min. Typ. Max. Units MTBF MIL HDBK 217F , 25°C, Gnd Benign 1.0 MHours Vibration 10 - 55 Hz, 10G, 30 Min, on X, Y & Z Axis Safety Standards UL 60950, EN 60950 (Pending) Absolute Maximum Ratings Parameter Conditions Min. Typ. Max. Units Input Voltage Surge (1 Sec) 24 VDC Input 50.0 VDC48 VDC Input 100.0 Lead Temperature 1.5 mm From Case for 10 Sec 300 °C Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. Electrical Specifi cations Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice.
www.micropowerdirect.com MicroPower Direct • 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com Model Selection Guide www.micropower direct.co mwww.micropowerdirect.com Notes: 1. The specifi ed maximum capacitive load is for each output. 2. Start up time is measured at nominal input and with a constant resistive load. 3. For ± 5 and ±9 V OUT models, the output accuracy is specifi ed as ±5%. 4. Cross regulation is measured with the main output set at 50% load. The second output is varied from 10% to 100% load. 5. When measuring output ripple, it is recommended that an external ceramic capacitor (approx 10 µF) be placed from the +VOUT to the -VOUT pins. 6. Transient recovery is measured to within a 1% error band for a load step change of 25%. 7. Short circuit protection is provided by a “hiccup mode” circuit. 8. The control input (pin 6) is referenced to the -V IN (pin 2) input. If it is grounded, the unit will shut off. 9. Operation at no-load will not damage the unit, but they may not meet all specifi cations. 10. These units should not be operated over +85°C. Exceeding +85°C may damage the unit. 11. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection table above for the correct rating. Model Number Input Output Effi ciency (%, Typ) Capacitive Load (µF , Max) Fuse Rating Slow-Blow (mA) Voltage (VDC) Current (mA) Voltage (VDC) Current (mA, Max) Current (mA, Min)Nominal Range Full-Load No-Load MB2024S-03ERW 24 18.0 - 36.0 799 40 3.3 5,000 0.0 86 10,000 2,000 MB2024S-05ERW 24 18.0 - 36.0 969 40 5.0 4,000 0.0 90 10,000 2,000 MB2024S-09ERW 24 18.0 - 36.0 947 6 9.0 2,222 0.0 89 4,700 2,000 MB2024S-12ERW 24 18.0 - 36.0 947 6 12.0 1,667 0.0 89 1,600 2,000 MB2024S-15ERW 24 18.0 - 36.0 947 6 15.0 1,333 0.0 90 1,000 2,000 MB2024S-24ERW 24 18.0 - 36.0 947 6 24.0 834 0.0 90 500 2,000 MB2024D-05ERW 24 18.0 - 36.0 969 40 ±5.0 ±2,000 ±0.0 86 4,800 2,000 MB2024D-09ERW 24 18.0 - 36.0 947 6 ±9.0 ±1,111 ±0.0 88 1,000 2,000 MB2024D-12ERW 24 18.0 - 36.0 947 6 ±12.0 ±834 ±0.0 88 800 2,000 MB2024D-15ERW 24 18.0 - 36.0 947 6 ±15.0 ±667 ±0.0 88 625 2,000 MB2048S-03ERW 48 36.0 - 75.0 400 25 3.3 5,000 0.0 86 10,000 1,000 MB2048S-05ERW 48 36.0 - 75.0 485 25 5.0 4,000 0.0 90 10,000 1,000 MB2048S-09ERW 48 36.0 - 75.0 474 9 9.0 2,222 0.0 89 4,700 1,000 MB2048S-12ERW 48 36.0 - 75.0 474 9 12.0 1,667 0.0 89 1,600 1,000 MB2048S-15ERW 48 36.0 - 75.0 474 9 15.0 1,333 0.0 90 1,000 1,000 MB2048S-24ERW 48 36.0 - 75.0 474 9 24.0 834 0.0 90 500 1,000 MB2048D-05ERW 48 36.0 - 75.0 485 25 ±5.0 ±2,000 ±0.0 86 4,800 1,000 MB2048D-12ERW 48 36.0 - 75.0 474 9 ±12.0 ±834 ±0.0 88 800 1,000 MB2048D-15ERW 48 36.0 - 75.0 474 9 ±15.0 ±667 ±0.0 89 625 1,000 Derating Curve External Trim External Trim Notes: On single output units, an external resistor can be used to adjust the converter output up/down by about 10%. The connection is shown in the diagram at left. The required resistor value is calculated by the formulas: Where R TRIM = The value of the external trim resistor V TRIM = The amount of voltage adjustment required The value of R1, R2, R3 and VREF are given in the table below. Trim Down= RTRIM = R1 - A A $ R1 - R3 Where A = VREF VTRIM - VREF $ R2 Trim UP= RTRIM = R2 - A A $ R2 - R3 Where A = VTRIM - VREF VREF $ R1 Parameter Output Voltage (VDC) 3.3 5.0 9.0 12 15 24 If not used, the Trim pin (pin 4) should be left open. Please contact the factory for more information.
www.micropowerdirect.com MicroPower Direct • 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.comMicroPower Direct • 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com www.micropower direct.co mwww.micropowerdirect.comEMC Specifi cations Parameter Standard Radiated Emissions See Note 1 EN 55022 Class A Conducted Emissions See Note 1 EN 55022 Class A ESD EN 61000-4-2 Criteria B; ±4 kV Contact RS EN 61000-4-3 Criteria A; 10V/m EFT See Note 2 EN 61000-4-4 Criteria B; ±2 kV Surge See Note 3 EN 61000-4-5 Criteria B; ±2 kV CS EN 61000-4-6 Criteria A; 3 Vrms Voltage Dips EN 61000-4-29 Criteria B; 0% - 70% Typical Connection The diagram above illustrates a typical connection of the MB2000ERW series for applications that require meeting EMC standards. The units do not require external components to operate as specifi ed. Some notes on this diagram (starting with the input circuit) are: 1. It is recommended that an external fuse be used. The recommended fuse is shown in the model chart on page 2. 2. An external MOV is recommended on the input to protect the unit in the event of a surge. A recommended value is given in the table at right. 3. The output fi ltering capacitor (C 3) is a high frequency, low resistance electrolytic capacitor. Care must be taken in choosing this capacitor not to exceed the capacitive load specifi cation for the unit. The board layout illustration below shows a connection for dual output units. Voltage derating of capacitors should be 80% or above. Notes: 1. All units are rated for EN 55022 (CE/RE) class A without external components. They will meet class B with the addition of the MDCFM-xxW (or a similar discrete fi lter circuit). Contact the factory for more information. 2. To meet the requirements of EN 61000-4-4 (±2 kV), external components are needed. This can be done discretely, or with the addition of the MDCFM-xxW. Contact the factory for more information. 3. To meet the requirements of EN 61000-4-5 (±2 kV line to line), external components are needed. This can be done discretely, or with the addition of the MDCFM-xxW. Contact the factory for more information. 4. Recommended values for components are: Component 24 VIN 48 VIN MOV S20K30 S14K60 C1 330 µF/50V 330 µ F/100V C2 1.0 µF/50V 1.0 µ F/100V L1 4.7 µH 4.7 µ H CY1, CY2 1,000 pF/2 kV 1,000 pF/2 kV 5. Input noise and surge suppression modules are available for a number of MPD DC/DC power supplies. For pricing or full techni- cal information on these modules please contact the factory. 6. In many applications simply adding input/output capaci- tors will enhance the input surge protection and reduce output ripple suffi ciently. The input capacitor C 1 and output capacitor C3 shown in the typical connection diagram above illustrate their connec- tion. Recommended capacitor values are given in the table at right. Vin (VDC) Input Capacitor Vout (VDC) Output Capacitor 24 100 µF 3.3 470 µF 5.0 470 µF 48 100 µF 9.0 220 µF 12 220 µF 15 220 µF 24 100 µF ±5 ±220 µF ±9 ±100 µF ±12 ±100 µF ±15 ±100 µF Effi ciency vs Input Voltage: (FL, 24 VIN) Effi ciency vs Output Load: (24 VIN) Effi ciency vs Input Voltage: (FL, 48 VIN) Effi ciency vs Output Load: (48 VIN)
www.micropowerdirect.com MicroPower Direct • 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com Mechanical Dimensions Mechanical Dimensions: With Optional Heatsink Pin Single Output Pin Dual Output 1+ V IN 1+ V IN 2- V IN 2- V IN 3+ V OUT 3+ V OUT
4 Trim 4 Common
6 Remote On/Off 6 Remote On/Off
For the heatsink option, add suffi x “H” to the model number (i.e. MB2024S-05ERW-H) Notes:
- All dimensions are typical in inches (mm)
- Tolerance x.xx = ±0.02 (±0.50)
- Weight (Typ) = 0.92 Oz (26g) Notes:
- All dimensions are typical in inches (mm)
- Tolerance x.xx = ±0.02 (±0.50)
- Weight (Typ) = 1.20 Oz (34g)
www.micropowerdirect.com MicroPower Direct • 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com Mechanical Dimensions: A2 Chassis Mount Adapter Mechanical Dimensions: A4 DIN Rail Adapter For the chassis mount option, add suffi x “A2” to the model number (i.e. MB2024D-09ERW-A2) For the DIN rail mount option, add suffi x “A4” to the model number (i.e. MB2024D-09ERW-A4) Pin Single Output Dual Output
1 Remote On/Off
5 Trim ( •) Common
Notes:
- All dimensions are typical in inches (mm)
- Tolerance x.xx = ±0.02 (±0.50)
- Weight (Typ) = 1.69 Oz (48g) Notes:
- All dimensions are typical in inches (mm)
- Tolerance x.xx = ±0.02 (±0.50)
- Weight (Typ) = 2.40 Oz (68g)
www.micropowerdirect.com MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com icropowerdirect .com Mechanical Dimensions: A2 Chassis Mount Adapter Mechanical Dimensions: A4 DIN Rail Adapter For the chassis mount option, add suffi x “A2” to the model number (i.e. MB2048S-12ERW-A2 -H) For the DIN rail mount option, add suffi x “A4” to the model number (i.e. MB2048S-12ERW-A4-H) Pin Single Output Dual Output Notes:
- All dimensions are typical in inches (mm)
- Tolerance x.xx = ±0.02 (±0.50)
- Weight (Typ) = 1.98 Oz (56g) Notes:
- All dimensions are typical in inches (mm)
- Tolerance x.xx = ±0.02 (±0.50)
- Weight (Typ) = 2.68 Oz (76g)