MODEL: MAH http://www.m-system.co.jp/ MAH SPECIFICATIONS ES-8180 Rev.3 Page 1/4 Lightning Surge Protectors for Electronics Equipment M-RESTER LIGHTNING SURGE PROTECTOR FOR POWER SUPPLY USE (20 A) Functions & Features

  • Designed specifically for power requirements of medium capacities (20 amps)
  • Protecting electronic equipment from lightning surges that enter through power supply circuits
  • Discharge current capacity 10000 A
  • Surge absorber failure indicated with LED
  • Detaching the discharge elements from the power supply circuits when fuses are blown Typical Applications
  • Computers and other electronic devices
  • Control and telemetering systems 80 (3.15) 95 (3.74) 250 (9.84) NN JODI MODEL: MAH–[1]

ORDERING INFORMATION

  • Code number: MAH–[1] Specify a code from below for [1]. (e.g. MAH-223) [1] OPERATIONAL VOLTAGE 121: Single phase 2-wire, 100 V / 110 V / 120 V AC 221: Single phase 2-wire, 200 V / 220 V / 240 V AC 123: Single phase 3-wire, 100 V / 110 V / 120 V AC (Phase voltage (line-neutrality)) 223: Three phase 3-wire, 200 V / 220 V / 240 V AC GENERAL SPECIFICATIONS Construction: Stand-alone; terminal access at the front Connection: M4 screw terminals (torque 1.6 N·m) Screw terminal: Nickel-plated brass Housing material: Steel plate t = 1.6 (black) Alarm indicator LED: Red lights turn ON with power supplied; OFF at error INSTALLATION Operating temperature: -5 to +55°C (23 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Surface Weight: 2 kg (4.4 lbs) PERFORMANCE Response time: ≤ 0.1 μsec. Discharge current capacity: 10000 A (8/ 20 μsec.) Maximum load current: 20 A Voltage drop: ≤ 1 V (50/60 Hz) BETWEEN LINES LINE TO GND MAH-121 (MAH-123 line-neutrality) MAH-221, 223 (MAH-123 1-3) Discharge volt. (peak volt.) 190V min. 380V min. 380V min. Max. surge voltage * 350V max. 700V max. 700V max. Leakage current ≤40mA @110V AC ≤40mA @220V AC ≤1mA @220V AC * The maximum voltage that could pass through M-REST- ER. Protected equipment must be able to withstand this voltage for very short time period. ** Including the current consumed at the LEDs.

MODEL: MAH http://www.m-system.co.jp/ MAH SPECIFICATIONS ES-8180 Rev.3 Page 2/4 CONNECTION EXAMPLES 4 G U V V BAC SOURCE M-RESTER BREAKER Be sure to install the breaker. PROTECTED EQUIPMENT 4 G 1 U W BAC SOURCE M-RESTER BREAKER Be sure to install the breaker. PROTECTED EQUIPMENT ■ Single phase 2-wire ■ Three phase 3-wire ■ Single phase 3-wire N 4 G 1 U V BAC SOURCE M-RESTER BREAKER Be sure to install the breaker. PROTECTED EQUIPMENT GROUNDING M-RESTER PROTECTED EQUIPMENT GG CROSSOVER WIRE GROUNDING (100 ohms or less) A crossover wire between M-RESTER ground and ground or metallic housing of equipment is required for protection. If the protected equipment has no ground terminal, ground the M-RESTER only.

MODEL: MAH http://www.m-system.co.jp/ MAH SPECIFICATIONS ES-8180 Rev.3 Page 3/4 EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENT mm (inch) 5 6 7 8 1 2 3 4 LINE LOAD GND ALARM 5 6 7 8 1 2 3 4 LINE LOAD GND ALARM 80 (3.15) 10 (.39) 10 (.39) 6 (.24) 250 (9.84) 8–M4 SCREW TERMINAL 10 (.39) ALARM INDICATOR LED (four) ■ 3-WIRE 80 (3.15) 10 (.39) 10 (.39) 6 (.24) 250 (9.84) 8–M4 SCREW TERMINAL 10 (.39) ALARM INDICATOR LED (two) ■ 2-WIRE MOUNTING REQUIREMENTS unit: mm (inch) 230 (9.06) 40 (1.57) 4±M5 SCREWS

MODEL: MAH http://www.m-system.co.jp/ MAH SPECIFICATIONS ES-8180 Rev.3 Page 4/4 SCHEMATIC CIRCUITRY TO EQUIP- MENT TO CABLE ALARM 2 Surge Absorber ALARM 1 Surge Absorber ■ Single phase 2-wire 3 7 TO EQUIP- MENT TO CABLE Surge Absorber ALARM 3 ALARM 1 ALARM 4 ALARM 2 Surge Absorber ■ Three phase 3-wire 2 6 TO EQUIP- MENT TO CABLE Surge Absorber ALARM 3 ALARM 1 ALARM 4 ALARM 2 Surge Absorber ■ Single phase 3-wire 2 6Neutral Neutral Specifications are subject to change without notice.