Note: Due to continuous process improvement, specifications are subject to change without notice. This document is cleared for public release. Wilcoxon Sensing Technologies 8435 Progress Drive Frederick, MD 21701 USAAn Amphenol Company buy.wilcoxon.com www.wilcoxon.com Tel: +1 (301) 330-8811 Fax: +1 (301) 330-8873 info@wilcoxon.com SPECIFICATIONS MAC200 Handheld vibration meter Accessories supplied: MAC002 protective boot with magnets; MAC003 carrying case with insert; extended stinger Key features

  • Versatile meter for walkaround monitoring programs
  • Built-in ISO alarms
  • 100 and 800 line FFT spectrum
  • BDU reading
  • High performance accelerometer with stinger
  • Manufactured in ISO 9001 facility Size 7.95 x 2.36 x 1” (20 x 6 x 2.6 cm) Weight (excluding magnet) 280 grams (9.8 oz) Environmental: Water Operating temperature Storage temperature IP67 waterproof 0° to +50°C –20° to +70°C Power supply 2x AA batteries Battery life 50 hours normal use Frequency ranges: ISO BDU

2 Hz - 1 kHz

1 Hz - 15 kHz

Max frequency resolution 1.25 Hz at 800 lines FFT setting Displayed amplitude units: Acceleration Bearing damage Velocity g BDU in/sec or mm/sec Displayed frequency units Hz or CPM Input range ± 50 g Dynamic range, 0.01 g resolution 72 dB VA bands Auto set-up Accelerometer connection internal sensor Display OLED full color, high contrast Selectable languages English (default), Spanish, Portuguese, French, Italian, Turkish, Chinese, Japanese and Korean 99193 Rev.B.1 09/18