Key Features: 6W Output Power 4 kVAC rms Isolation Reinforced Insulation 2 µA Leakage Current Max Wide 2:1 Input Range Compact DIP Case Single & Dual Outputs Meets EN55022 700 kH MTBF EN 60950 Approved EN 60601 Approved MA600MHI High Isolation, 6W Medical Approved DC/DC Con vert ers Series Input Parameter Conditions Min. Typ. Max. Units Input Start Voltage 12 VDC Input 7.0 8.0 9.0 VDC24 VDC Input 13.0 15.0 18.0 48 VDC Input 30.0 33.0 36.0 Under Voltage Shutdown 12 VDC Input 8.5 VDC24 VDC Input 16.0 48 VDC Input 34.0 Input Filter /H9266 (Pi) Filter (Complies with EN55022 Class A) Leakage Current 240 VAC, 60 Hz 2 µA Short Circuit Input Power 3,000 mW Output Parameter Conditions Min. Typ. Max. Units Output Voltage Accuracy ±0.5 ±1.0 % Output Voltage Balance Dual Output , Balanced Loads ±0.5 ±2.0 % Line Regulation Vin = Min to Max ±0.3 ±0.5 % Load Regulation Iout = 25% to 100% ±0.5 ±1.0 % Ripple & Noise (20 MHz), See Note 1 5V Output 75 100 mV P - PAll Other Outputs 100 150 Ripple & Noise (20 MHz) Over Line, Load & Temp. 180 mV P - P Ripple & Noise (20 MHz) 25 mV rms Output Power Protection 120 % Transient Recovery Time, See Note 2 25% Load Step Change 300 500 µSec Transient Response Deviation ±3.0 ±6.0 % Temperature Coeffi cient ±0.02 ±0.05 %/ºC Output Short Circuit Continuous (Autorecovery) General Parameter Conditions Min. Typ. Max. Units Isolation Voltage, Rated 60 Seconds 4,000 VAC rms Isolation Test Voltage Flash Tested For 1 Sec 6,000 VPk Reinforced Insulation Working Voltage 300 VAC Isolation Resistance 500 VDC 1,000 M/H9024 Isolation Capacitance 100 kHz, 1V 7 13 pF Switching Frequency 150 kHz Environmental Parameter Conditions Min. Typ. Max. Units Operating Temperature Range Ambient -40 +75 ºC Operating Temperature Range Case -40 +95 ºC Storage Temperature Range -50 +125 ºC Cooling Free Air Convection Humidity RH, Non-condensing 95 % Physical Case Material Non-Conductive Black Plastic (UL94-V0) Weight 0.63 Oz (18.0g) Reliability Specifi cations Parameter Conditions Min. Typ. Max. Units MTBF MIL HDBK 217F , 25ºC, Gnd Benign 700 kHours Safety Approvals UL 60601, UL 60950, EN 60601, EN 60950 Absolute Maximum Ratings Parameter Conditions Min. Typ. Max. Units Input Voltage Surge (1 Sec) 12 VDC Input -0.7 25.0 VDC24 VDC Input -0.7 50.0 48 VDC Input -0.7 100.0 Lead Temperature 1.5 mm From Case For 10 Sec 260 ºC Internal Power Dissipation All Models 2,500 mW Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. www.micropowerdirect.com Electrical Specifi cations Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice. MicroPower Direct
292 Page Street
Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com
Input Refl ected Ripple Current (mA, Typ) Output Capacitive Load (µF, Max) Effi ciency (%, Typ) Fuse Rating Slow-Blow (mA) Voltage (VDC) Current (mA) Voltage (VDC) Current (mA, Max) Current (mA, Min)Nominal Range Full-Load No-Load MA612MS-05HI 12 9.0 - 18.0 570 30 60 5.0 1,000 200.0 1,000 75 1,200 MA612MS-12HI 12 9.0 - 18.0 641 30 60 12.0 500 100.0 470 78 1,200 MA612MD-12HI 12 9.0 - 18.0 641 30 60 ±12.0 ±250 ±50.0 ±220 78 1,200 MA612MD-15HI 12 9.0 - 18.0 641 30 60 ±15.0 ±200 ±40.0 ±220 78 1,200 MA624MS-05HI 24 18.0 - 36.0 278 20 30 5.0 1,000 200.0 1,000 77 600 MA624MS-12HI 24 18.0 - 36.0 313 20 30 12.0 500 100.0 470 80 600 MA624MD-12HI 24 18.0 - 36.0 313 20 30 ±12.0 ±250 ±50.0 ±220 80 600 MA624MD-15HI 24 18.0 - 36.0 313 20 30 ±15.0 ±200 ±40.0 ±220 80 600 MA648MS-05HI 48 36.0 - 75.0 139 10 15 5.0 1,000 200.0 1,000 77 300 MA648MS-12HI 48 36.0 - 75.0 156 10 15 12.0 500 100.0 470 80 300 MA648MD-12HI 48 36.0 - 75.0 156 10 15 ±12.0 ±250 ±50.0 ±220 80 300 MA648MD-15HI 48 36.0 - 75.0 156 10 15 ±15.0 ±200 ±40.0 ±220 80 300 Pin Single Dual 1+ V IN +VIN
11 No Pin Common
15 No Pin +V OUT
Mechanical Notes:
- All dimensions are typical in inch es (mm)
- Tolerance x.xx = ±0.01 (±0.25) Notes: 1. When measuring output ripple, it is recommended that an external 0.47 µ F ceramic capacitor be placed from the +Vout pin to the -Vout pin for single output units and from each output to common for dual output units. For noise sensitive applications, the use of 3.3 µF capacitors will reduce the output ripple. 2. Transient recovery is measured to within a 1% error band for a load step change of 75% to 100%. 3. Dual output units may be connected to provide a 24 VDC or 30 VDC output. To do this, connect the load across the positive (+Vout) and negative (-Vout) outputs and fl oat the output common. 4. The converter should be connected to a low ac-impedance source. An input source with a highly inductive impedance may affect the stability of the converter. In applications where the converter output loading is high and input power is supplied over long lines, it may be necessary to use a capacitor on the input to insure start-up. In this case, it is recommended that a low ESR (ESR <1.0/H9024 at 100 kHz) capacitor be mounted close to the converter. For 12V input units a 10.0 µF is recommended, for 24V a 4.7 µF and for 48V units a 2.2 µ F. 5. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the correct rating. Pin Connections MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 TEL: (781) 344-8226 FAX: (781) 344-8481 E-Mail: sales@micropowerdirect.com www.micropowerdirect.com Derating Curve