www.micropowerdirect.com MicroPower Direct
292 Page Street
Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com Key Features: 6W Output Power 2:1 Input Voltage Range 3,000 VDC Isolation 24 Standard Models Single & Dual Outputs Compact DIP Case -40°C to +85°C Operation Industry Standard Pin-Out MA600RWI Wide 2:1 Input, 6W, High 3 kVDC Isolation DC/DC Con vert ers Input Parameter Conditions Min. Typ. Max. Units Input Start Voltage 12 VDC Input 7.0 8.0 9.0 VDC24 VDC Input 14.0 16.0 18.0 48 VDC Input 32.0 34.0 36.0 Under Voltage Shutdown 12 VDC Input 8.5 VDC24 VDC Input 16.0 48 VDC Input 35.0 Input Filter /H9266 (Pi) Filter Output Parameter Conditions Min. Typ. Max. Units Output Voltage Accuracy ±1.0 ±2.0 % Output Voltage Balance Dual Output, Balanced Loads ±1.0 ±2.0 % Line Regulation VIN = Min to Max ±0.1 ±0.5 % Load Regulation I OUT = 0% to 100% ±0.6 ±1.2 % Ripple & Noise (20 MHz) See Note 1 70 mV P - POver Line, Load & Temp. 100 Transient Recovery Time, See Note 2 25% Load Step Change 300 600 µSec Transient Response Deviation ±3.0 % Temperature Coeffi cient ±0.01 ±0.02 %/°C Output Overload Protection Foldback 110 145 % Output Short Circuit Continuous (Autorecovery) General Parameter Conditions Min. Typ. Max. Units Isolation Voltage 60 Seconds 3,000 VDC Isolation Resistance 500 VDC 1,000 M Isolation Capacitance 100 kHz/1.0V 1,000 pF Switching Frequency 330 kHz EMI Characteristics Parameter Standard Level Radiated Emissions EN 55022 Class A Conducted Emissions EN 55022 Class A ESD EN 61000-4-2 Criteria A; ±8 kV Air ±6 kV Contact RS EN 61000-4-3 Criteria A; 10V/m EFT See Note 3 EN 61000-4-4 Criteria A; ±2 kV Surge See Note 3 EN 61000-4-5 Criteria A; ±1 kV CS EN 61000-4-6 Criteria A; 10V/m Environmental Parameter Conditions Min. Typ. Max. Units Operating Temperature Range Ambient -40 +25 +85 °C Operating Temperature Range Case +100 °C Storage Temperature Range -50 +125 °C Cooling Free Air Convection Humidity RH, Non-condensing 95 % Physical Case Material Non-Conductive Black Plastic (UL94-V0) Weight 0.45 Oz (12.8g) Reliability Specifi cations Parameter Conditions Min. Typ. Max. Units MTBF MIL HDBK 217F , 25°C, Gnd Benign 1.0 MHours Absolute Maximum Ratings Parameter Conditions Min. Typ. Max. Units Input Voltage Surge (1 Sec) 12 VDC Input -0.7 25.0 VDC24 VDC Input -0.7 50.0 48 VDC Input -0.7 100.0 Lead Temperature 1.5 mm From Case for 10 Sec 260 °C Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. Electrical Specifi cations Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice. Series 4:1 Input Range Models Available 1.5 kV Isolation Models Available
We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com www.micropowerdirect.comModel Selection Guide Model Number Input Output Effi ciency (%, Typ) Refl ected Ripple Current (mA Typ) Capacitive Load (µF , Max) Fuse Rating Slow-Blow (mA) Voltage (VDC) Current (mA) Voltage (VDC) Current (mA, Max) Current (mA, Min)Nominal Range Full-Load No-Load For 1.5 kV Isolation, See MA600x-xxRW Series Datasheet For 4:1 Inputs, See MA600x-xxRU Series Datasheet Mechanical Notes:
- All dimensions are typical in inch es (mm)
- Tolerance x.x = ±0.02 (±0.50)
- Tolerance x.xx = ±0.01 (±0.25) Notes: 1. When measuring output ripple, it is recommended that an external 3.3 µ F ceramic capacitor be placed from the +VOUT pin to the -V OUT pin for single output units and from each output to common for dual output units. 2. Transient recovery is measured to within a 1% error band for a load step change of 75% to 100%. 3. Operation at no-load will not damage these units. 4. An external 220 µ F/100V capacitor connected across the input pins is required to meet EN61000-4-4 and EN61000-4-5. 5. Dual output units may be connected to provide a 10, 24 or 30 VDC output. To do this, connect the load across the positive (+V OUT) and negative (-V OUT) outputs and fl oat the output common. 6. The converter should be connected to a low ac-impedance source. An input source with a highly inductive impedance may affect the stability of the converter. In applications where the converter output loading is high and input power is supplied over long lines, it may be necessary to use a capacitor on the input to insure start-up. In this case, it is recommended that a low ESR (ESR <1.0/H9024 at 100 kHz) capacitor be mounted close to the converter. For 12V input units a 3.3 µF is recommended; and for 24V & 48V units a 2.2 µF. 7. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the correct rating. Pin Single Dual 2, 3 -V IN -VIN
9 No Pin Common
11 NC -V OUT
22, 23 +V IN +VIN NC: No Connection Pin Connections Mechanical Dimensions Pin Single Dual 2, 3 IN IN No Pin Common NC OUT V V OUT V V OUT V V OUT V V Common 22, 23 IN IN NC: No Connection Pin Connections Derating Curve