Technical content
Key Features: 6W Output Power 4:1 Input Voltage Range 3,000 VDC Isolation Eight Standard Models Effi ciency to 88% Compact DIP Case -40°C to +85°C Operation Industry Standard Pin-Out Low Cost MA600ERUI Wide 4:1 Input, 6W, High Isolation, DIP DC/DC Con vert ers Input Parameter Conditions Min. Typ. Max. Units Input Start Voltage 24 VDC Input 9.0 VDC48 VDC Input 18.0 Input Filter /H9266 (Pi) Filter No Load Input Power 0.2 0.5 W Output Parameter Conditions Min. Typ. Max. Units Output Voltage Accuracy IOUT = 5% to 100% ±1.0 ±2.0 % Line Regulation V IN = Min to Max ±0.2 ±0.5 % Load Regulation I OUT = 5% to 100% ±0.5 ±1.0 % Ripple (20 MHz) See Note 1 15 30 mV P - P Noise (20 MHz), See Note 1 24 VDC Input 65 100 mV P - P48 VDC Input 85 150 Transient Recovery Time, See Note 2 25% Load Step Change 300 500 µSec Transient Response Deviation ±3.0 ±5.0 % Temperature Coeffi cient ±0.03 %/°C Output Over Voltage Protection 110 120 140 % Output Short Circuit, See Note 3 Continuous (Autorecovery) General Parameter Conditions Min. Typ. Max. Units Isolation Voltage 60 Seconds 3,000 VDC Isolation Resistance 500 VDC 1,000 M Isolation Capacitance 100 kHz/0.1V 120 pF Switching Frequency 330 kHz EMI Characteristics Parameter Standard Level Radiated Emissions See Note 4 EN 55022 Class A Conducted Emissions See Note 4 EN 55022 Class A ESD EN 61000-4-2 Criteria B; ±4 kV Contact RS EN 61000-4-3 Criteria A; 10V/m EFT See Note 5 EN 61000-4-4 Criteria B; ±2 kV See Note 5 EN 61000-4-4 Criteria B; ±4 kV Surge See Note 6 EN 61000-4-5 Criteria B; ±2 kV CS EN 61000-4-6 Criteria A; 3 Vrms Voltage Dips EN 61000-4-29 Criteria B; 0% - 70% Environmental Parameter Conditions Min. Typ. Max. Units Operating Temperature Range Ambient -40 +25 +85 °C Operating Temperature Range Case +105 °C Storage Temperature Range -55 +125 °C Cooling Free Air Convection Humidity RH, Non-condensing 95 % Physical Case Material Non-Conductive Black Plastic (UL94-V0) Weight 0.46 Oz (13g) Reliability Specifi cations Parameter Conditions Min. Typ. Max. Units MTBF MIL HDBK 217F , 25°C, Gnd Benign 1.0 MHours Absolute Maximum Ratings Parameter Conditions Min. Typ. Max. Units Input Voltage Surge (1 Sec) 24 VDC Input -0.7 50.0 VDC48 VDC Input -0.7 100.0 Lead Temperature 1.5 mm From Case for 10 Sec 300 °C Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. Electrical Specifi cations Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice. www.micropowerdirect.com MicroPower Direct
292 Page Street
Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com Series
www.micropowerdirect.com Notes: 1. When measuring output ripple & noise, it is recommended that an external capacitor (1 µF to 10 µF) be placed from the +VOUT to the -VOUT pins. 2. Transient recovery is measured to within a 1% error band for a load step change of 25%. 3. Short circuit protection is provided by a “hiccup mode” circuit. 4. All units are rated for EN 55022 (CE/RE) class A without external components. They will meet class B with the addition of the DCFM-0x (or a similar discrete fi lter circuit as shown on page 3). Contact the factory for more information. 5. To meet the requirements of EN 61000-4-4 (±2 kV), external components are needed, as shown on page 3. With the addition of the DCFM-0x, EN 61000-4-4 (±4 kV) can be achieved. Contact the factory for more information. 6. To meet the requirements of EN 61000-4-5 (±2 kV), external components are needed. This can be done discretely (as shown on page 3), or with the addition of the DCFM-0x. Contact the factory for more information. 7. These units should not be operated with a load under 5% of full load. Operation at no-load will not damage the unit, but they may not meet all specifi cations. 9. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection table above for the correct rating. Model Number Input Output Effi ciency (%, Typ) Refl ected Ripple Current (mA Typ) Capacitive Load (µF , Max) Fuse Rating Slow-Blow (mA) Voltage (VDC) Current (mA) Voltage (VDC) Current (mA, Max) Current (mA, Min)Nominal Range Full-Load No-Load MA624S-05ERUI 24 9.0 - 36.0 301 12 5.0 1,200 60 83 20.0 2,200 2,000 MA624S-12ERUI 24 9.0 - 36.0 287 12 12.0 500 25 87 20.0 680 2,000 MA624S-15ERUI 24 9.0 - 36.0 284 12 15.0 400 20 88 20.0 680 2,000 MA624S-24ERUI 24 9.0 - 36.0 287 12 24.0 250 12 87 20.0 680 2,000 MA648S-05ERUI 48 18.0 - 75.0 151 3 5.0 1,200 60 83 20.0 2,200 1,000 MA648S-12ERUI 48 18.0 - 75.0 143 3 12.0 500 25 87 20.0 680 1,000 MA648S-15ERUI 48 18.0 - 75.0 142 3 15.0 400 20 88 20.0 680 1,000 MA648S-24ERUI 48 18.0 - 75.0 143 3 24.0 250 12 87 20.0 680 1,000 Effi ciency vs Output Load 24 VDC Input Effi ciency vs Input Voltage 24 VDC Input Effi ciency vs Input Voltage 48 VDC Input Effi ciency vs Output Load 48 VDC Input Derating Curve 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com
www.micropowerdirect.com Typical Connection The diagram above illustrates a typical connection of the MA600ERUI series for applications that require meeting EMC standards. The units do not require external components to operate as specifi ed. Some notes on this diagram (starting with the input circuit) are: 1. It is recommended that an external fuse be used. The recommended fuse is shown in the model chart on page 2. 2. An external MOV is recommended on the input to protect the unit in the event of a surge. A recommended value is given in the table at right. 3. An external TVS is recommended on the input to protect the unit in the event of a voltage spike. A recommended value is given in the table at right. 4. The output fi ltering capacitor (C 4) is a low ESR electrolytic capacitor. Care must be taken in choosing this capacitor not to exceed the capacitive load specifi cation for the unit. Voltage derating of capacitors should be 80% or above. Typical Board Layout: With External Filter/Surge Components 5. Recommended values for components are: Component 24 VIN 48 VIN MOV S14K35 S14K60 LDM 56 µH 56 µ H TVS SMCJ48A SMCJ90A C1 330 µF/50V 330 µ F/100V C2, C3 2.2 µF/50V 2.2 µ F/100V LCM 2.2 mH 2.2 mH C4 10 µF 10 µ F Typical Connection: With DCFM-0x ISurge Suppression and Filter Module 6. The drawing below shows a suggested board layout for the EMC/EMI circuit shown above. Filtering capacitor (C4) is a low ESR resistance electrolytic capacitor. Care must be taken in choosing this capacitor not to exceed the capacitive load specifi cation for the unit. 7. In many applications simply adding input/output capaci- tors will enhance the input surge protection and reduce output ripple suffi ciently. T ypically, the value of the input capacitor should be > 330 µF. The output capacitor would be 10 µF. Input noise and surge suppression modules are available for a number of MPD DC/DC power supplies. An MA600ERUI connection with the DCFM-02 (noise suppression) module connected to the input is shown below. The recommended input capacitor (C 1) is a 330 µF/50V for 24 VDC input models and 330 µF/100V for 48 VDC input units. The output capacitor would be 10 µF. For pricing or full technical information on these modules (DCFM-01, DCFM-02 and DCFM-03) please contact the factory. MicroPower Direct • 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com
www.micropowerdirect.com Notes:
- All dimensions are typical in inches (mm)
- Tolerance x.xx = ±0.02 (±0.50)
- Pin 1 is marked by a “dot” or indentation on the top of the unit Notes: All dimensions are typical in inches (mm) Tolerance x.xx = 0.02 ( 0.50) Pin 1 is marked by a “dot” or indentation on the top of the unit Mechanical Dimensions Pin Single Output 2- V i n 3- V i n
11 No Connection
We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com Notes:
- Tube length equals 20.866 (530), unit quantity equals 15 pcs.
- Tube length equals 8.661 (220), unit quantity equals 6 pcs.
- All dimensions are typical in inches (mm)