DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 3
Technical content
www.micropowerdirect.com MicroPower Direct
292 Page Street
Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com Key Features: 15W Output Power 4:1 Input Voltage Range Compact DIP Case 1,600 VDC I/O Isolation Meets EN 55032 “A” Single & Dual Outputs Remote On/Off Control Wide Temperature Operation Industry Standard Pin-Out MA1500RU 4:1 Input Range, 15W Single & Dual Output DC/DC Con vert ers Series Electrical Specifi cations Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice. Input Parameter Conditions Min. Typ. Max. Units Start Up Time Nominal VIN & Constant Resistive Load 20 mS Input Filter /H9266 (Pi) Filter Input Refl ected Ripple Current 20.0 mA P - P Output Parameter Conditions Min. Typ. Max. Units Output Voltage Accuracy ±1.0 % Line Regulation, VIN = Min to Max Single Output ±0.2 Dual Output ±0.5 % Load Regulation, See Note 2 Single Output ±0.5 %Dual Output ±1.0 Cross Regulation, Dual Output See Note 3 ±5.0 % Ripple & Noise (20 MHz) See Note 4 60 mV P - P Transient Recovery Time, See Note 5 25% Load Step Change 250 µSec Transient Response Deviation ±3.0 % Output Power Protection 150 % I OUT Temperature Coeffi cient ±0.02 %/ºC Output Short Circuit Protection Continuous (Autorecovery) General Parameter Conditions Min. Typ. Max. Units Isolation Voltage Input/Output, 60 Seconds 1,600 VDCCase/Input, Output, 60 Seconds 1,600 Isolation Resistance 500 VDC 1,000 M/H9024 Isolation Capacitance 100 kHz/1V 2,000 pF Switching Frequency 280 kHz Remote On/Off (See Page 2) Parameter Conditions Min. Typ. Max. Units Supply On See Note On Page 3 3.0 12 VDC Supply Off 0.0 1.2 VDC Standby Input Current 5.0 mA Control Common Referenced to -Input (Pins 2, 3) Environmental Parameter Conditions Min. Typ. Max. Units Operating Temperature Range Ambient -40 +85 ºC Case +105 ºC Storage Temperature Range -40 +125 ºC Cooling Free Air Convection Humidity RH, Non-condensing 95 % Physical Case Size See Mechanical Diagram (Page 3) Case Material Copper With Nickel Coating (UL94V-0) Weight 0.705 Oz (18g) Reliability Specifi cations Parameter Conditions Min. Typ. Max. Units MTBF MIL HDBK 217F , 25ºC, Gnd Benign 410 kHours Absolute Maximum Ratings Parameter Conditions Min. Typ. Max. Units Input Voltage Surge (1 Sec) 24 VDC Input 50.0 VDC48 VDC Input 100.0 Lead Temperature 1.5 mm From Case For 10 Sec 260 ºC Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com Page 2 We Power Your Success - For Less Model Selection Guide Notes: 1. The specifi ed maximum capacitive load is for each output. 2. Load regulation is specifi ed for a load change of 0% to 100%. Load regulation for 3.3V output models is ±1.0% max for a load change of 0% to 100%. 3. When measuring cross regulation, the load on one output is varied from 25% to 100% while the other output is held at 100%. 4. Output ripple is measured with a 1.0 µF capacitor connected from the +V OUT to the -VOUT pins for single output units and from each output to common for dual output models. See the typical connection diagram & notes on page 3. 5. Transient recovery is measured to within a 1% error band for a load step change of 75% to 50% to 25%. 6. Operation at no-load will not damage these units. However, they may not meet all specifi cations. 7. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the correct rating. Temperature Derating Curve Model Number Input Output Over Voltage Protection (VDC) Max Capacitive Load (µF Max) Effi ciency (%, Typ) Fuse Rating Slow-Blow (mA) Voltage (VDC) Current (mA) Voltage (VDC) Current (mA, Max) Current (mA, Min)Nominal Range Full-Load No-Load Typical Connection EMI Characteristics Parameter Standard Criteria/Level Radiated Emissions EN 55032 Class A Conducted Emissions EN 55032 Class A ESD EN 61000-4-2 B RS EN 61000-4-3 A EFT EN 61000-4-4 B Surge EN 61000-4-5 B CS EN 61000-4-6 A PFM EN 61000-4-8 A To meet the requirements of EN 61000-4-4 & EN 61000-4-5, the external fi lter capaci- tors (C 1 & C2) in the diagram above) are required. The recommended value for C1 & C2 is 330 µF/100V. A single 680 µF/100V capacitor may also be used. When measuring output ripple, it is recommended that an external 1.0 µF ceramic capacitor be placed from the +V OUT pin to the -V OUT pin for single output units and from each output to common for dual output units. For noise sensitive applications, the use of 3.3 µF capacitors will reduce the output ripple. The Remote On/Off circuit is referenced to the minus input of the unit (pins 2 & 3). If the On/Off input (pin 1) is connected to the minus input, the unit is shut off. If pin 1 is left open, the unit operates normally.
www.micropowerdirect.com MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 TEL: (781) 344-8226 FAX: (781) 344-8481 E-Mail: sales@micropowerdirect.com Mechanical Dimensions Mechanical Notes:
- All dimensions are typical in inch es (mm)
- Tolerance x.xx = ±0.02 (±0.50) Mechanical Notes: All dimensions are typical in inch es (mm) Tolerance x.xx = ±0.02 (±0.50) Pin Single Dual
1 Remote On/Off Remote On/Off
9 No Pin Common
11 NC -V OUT
NC: No Connection Pin Connections Effi ciency vs Output Load: 48 VIN Models Effi ciency vs Output Load: 24 VIN Models MPD offers a wide range of DC/DC converters in the standard 24 pin DIP package. Models range from 1W to 15W and offer wide input ranges, high isolation & tight regulation. Many are approved to EN 60950. For full in- formation, go to our website or contact the factory.