P3S3FE3 XPPOWER | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 10

Technical content

  • Configurable for Fast Time to Market
  • Industrial/IT & Medical Approvals
  • All Outputs Isolated
  • Low Profile 1U Applications
  • Wide Voltage Adjustment Range
  • SEMI F47 Certified
  • Rugged Compact Design LP & LP-MD Series Input Input Voltage • 90-264 VAC Input Frequency • 47-63 Hz Inrush Current • 20 A pk max Power Factor • Compliant with EN61000-3-2 Output Output Voltage • See module table Output Voltage Trim • ±10 % min all modules. See module table for extended adjustment range Hold Up Time • 20 ms min Line Regulation • Typically 0.1%, maximum 0.3% Load Regulation • 1% max for single output modules & V1 of dual & triple output modules 2% max for V2 & V3 of dual & triple output modules A 10% load must be applied to output 1 of the high current dual module (U) & triple module (T) to achieve this figure Ripple & Noise • 50 mV or 1% pk-pk, whichever is greater,

20 MHz bandwidth

Overvoltage Protection • 120-130% Vnom for single output & output 1 of high current dual modules (U) & triple modules (T) Overload Protection • <140% of nominal rating Short Circuit Protection • Foldback Temperature • 0.03%/°C Coefficient Remote Sense • Compensates for up to 0.5 V drop on single (S) output modules & output 1 of dual (U) & triple (T) output modules Current Share • Single wire parallel current share. See signals & controls page xppower.com General Efficiency • 75% typical at nominal input Isolation • 4000 VAC Input to Output

1500 VAC Input to Ground

50 VAC Output to Ground

Signals & Controls • AC OK, DC OK, Global & Module Inhibit. See signals & controls page MTBF • 890 kHrs demonstrated Environmental Operating Temperature • 0 °C to +70 °C, derate linearly from 100% at +50 °C to 50% at +70 °C for fan versions. See airflow curves for U-channel versions. Storage Temperature • -40 °C to +85 °C Operating Altitude • 3000 m with no derating EMC & Safety Emissions • LP models P3-P5: EN55022, level B conducted LP-MD models, M3-M5: EN55011, level A conducted with FE(x) cover, level B conducted with ME(x) cover ESD Immunity • EN61000-4-2, level 3 Perf Criteria A Radiated Immunity • EN61000-4-3, level 3 Perf Criteria A EFT/Burst • EN61000-4-4, level 3 Perf Criteria A Surge • EN61000-4-5, level 3 Perf Criteria A Conducted Immunity • EN61000-4-6, level 3 Perf Criteria A Dips & Interruptions • EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Criteria A, B, B Safety Approvals • LP models: EN60950, UL60950, CSA22.2 No 950, CE Mark LVD, SEMI F47 compliant (highline only) LP-MD models: EN60601-1, CSA22.2-601, UL60601-1, CE Mark LVD

LP & LP-MDModel Configuration STEP 1 In order to configure a model number for your LP (industrial) or LP-MD (medical) series power supply, first select the appropriate chassis based on your application’s continuous, maximum output power requirements. Select ‘P’ for industrial or ‘M’ for medical. STEP 2 From the ratings below, select the output modules that suit your output voltage and current requirements. Modules can be positioned as denoted by the and sequence shown below. STEP 3 Form the model number as shown on the next page, ensuring you have selected a cooling method. P3 & M3 (250 W) Model P4 & M4 (350 W) Model P5 & M5 (450 W) Model 1. R modules do not have signals or control facilities. 2. Output V2 & V3 of U & T modules can supply up to 5 A in certain applications dependent on other rail loadings. Contact sales f or details. 3. Also available from Farnell and Newark. OUTPUT 1 OUTPUT 2 OUTPUT 3 MODULE CODE MODULE SIZE 2.5 V (2.25-2.75 V) @ 50 A S1 3.3 V (3.25-3.50 V) @ 50 A S2 5.0 V (4.50-5.50 V) @ 50 A S3 8.0 V (7.20-8.80 V) @ 31 A SF 10.0 V (9.00-11.00 V) @ 25 A SG 12.0 V (11.00-13.00 V) @ 20 A S4 15.0 V (14.00-16.00 V) @ 17 A S5 24.0 V (21.00-26.00 V) @ 10 A S6 28.0 V (25.00-31.00 V) @ 9 A S7 36.0 V (32.00-40.00 V) @ 7 A S8 48.0 V (43.00-53.00 V) @ 5 A S9 Module Position 2 1Module Position 2 1Module Position 2 1 None None None None None None Output Modules Voltage (Adjustment) & Current Ratings

LPPreconfigured Models - Industrial Output Power Max Output 1 Output 2 Output 3 Output 4 Industrial Version Model Number 250 W

5.0 V @ 50 A P3S3FE3

12.0 V @ 20 A P3S4FE3

24.0 V @ 10 A P3S6FE3

48.0 V @ 5 A P3S9FE3

5.0 V @ 50 A 5.0 V @ 50 A P4S3S3FE4 12.0 V @ 20 A 12.0 V @ 20 A P4S4S4FE4 450 W 12.0 V @ 20 A 12.0 V @ 20 A P5S4S4FE5 Model Number Example - Industrial (P) Versions P3 S3 T1 FE3 01 Chassis Power Module Position 2 Module Position 1 Fan Assembly Style Parallel Option Choose the chassis code first: P3 = 250 W Chassis P4 = 350 W Chassis P5 = 450 W Chassis Add any or module e.g. S3 = Single 5 V Add any or module e.g. T1 = Triple 5 V/12 V/12 V Add fan cover assembly. e.g. FE3 = End fan assembly for 250 W chassis Leave blank for open U-channel Add parallel option if required 2 x S module 1.8-15 V = 01 2 x S module 24-48 V = 02 Leave blank if not required P3 Model FE(x) End Fan Screw terminal AC connections NOTE: Model number format and module position may change dependent on module configuration chosen. Connector kits available. Order part number LP CONN KIT. Fan Assemblies Alternative fan assemblies are available. Consult sales for details. FTx Top Fan. Molex header AC connections End Fan. IEC AC connections

LP-MDPreconfigured Models - Medical 1. Medical versions shown include EMC class B fan assembly. Notes Model Number Example - Medical (M) Versions M3 S3 T1 ME3 01 Chassis Power Module Position 2 Module Position 1 Fan Assembly Style Parallel Option Choose the chassis code first: M3 = 250 W Chassis M4 = 350 W Chassis M5 = 450 W Chassis Add any or module e.g. S3 = Single 5 V Add any or module e.g. T1 = Triple 5 V/12 V/12 V Add fan cover assembly. e.g. ME3 = End fan assembly for 250 W chassis Leave blank for open U-channel Add parallel option if required 2 x S module 1.8-15 V = 01 2 x S module 24-48 V = 02 Leave blank if not required M3 Model FE(x) End Fan Screw terminal AC connections Class A NOTE: Model number format and module position may change dependent on module configuration chosen. Connector kits available. Order part number LP CONN KIT. Fan Assemblies Alternative fan assemblies are available. Consult sales for details. Top Fan. Molex header AC connectionsEnd Fan. IEC AC connections. Class A Output Power Max Output 1 Output 2 Output 3 Output 4 Medical Version Model Number 250 W

5.0 V @ 50 A M3S3ME3

12.0 V @ 20 A M3S4ME3

24.0 V @ 10 A M3S6ME3

48.0 V @ 5 A M3S9ME3

5.0 V @ 50 A 5.0 V @ 50 A M4S3S3ME4 12.0 V @ 20 A 12.0 V @ 20 A M4S4S4ME4 450 W 12.0 V @ 20 A 12.0 V @ 20 A M5S4S4ME5 End Fan. IEC Dual-fused and switched AC connections. Class B ME(x) End Fan Screw terminal AC connections Class B

  1. (R) module does not have these signal facilities. LP & LP-MDSignals & Controls AC OK/Power Fail When fitted in module position 2 of the chassis, pins 10 and 2 provide a minimum of 5 ms warning of loss of output regulation. Current Share Connecting pins 4 & 2 of like part number modules (3 maximum) within the same chassis or separate chassis will force the modules to current share the outputs. DC OK Pins 8 and 2 provide notification that the output voltage is within regulation via a logic 1. (Reverse logic option available, i.e. high for DC NOT OK). Global Inhibit Inhibiting the module fitted in position 2 will inhibit all outputs of other modules (fans remain running if fitted). If individual inhibit is required on the module fitted in chassis postion 2 alternative configurations are available. Please consult our application engineering team. Inhibit Pins 6 and 2 (return) provide on/off control of the module. Applying a logic ‘0’ between these pins turns the outputs off. (Reverse logic option available, i.e. high for outputs off or low for outputs on). Modules in Parallel Single output modules with the same part number and V1 of dual and triple output modules can be paralleled to obtain increased output current. These modules can either be fitted in the same chassis or a different chassis with their outputs connected directly together and current share connections made, see Current Share. Modules in Series Single output modules can be connected in series to obtain alternate output voltages not available from a single module. For example a 10 V (SG module) can be connected in series with a 12 V (S4 module) to obtain an output voltage of 22 V. Remote Sense Pins 1 (+ve) and 2 (-ve) provide compensation for voltage drops in application wiring up to a maximum of 0.5 V. Remote Sense is not fitted to (R) modules and V2 & V3 of (U) and (T) modules. Housekeeping A 5 V standby voltage rated at 1 A is fitted to each chassis. AC OK (HIGH) AC NOT OK (LOW) 5 V 330Ω PIN 10 PIN 2 INTERNAL TO PSU (Open Collector) Module 1 Module 2 Module 3 Pin 4 Pin 4 Pin 2Pin 4Pin 2 Pin 2 DC OK (HIGH) DC NOT OK (LOW) 5 V 330Ω PIN 8 PIN 2 INTERNAL TO PSU (Open Collector) OUTPUTS ON OUTPUTS OFF 0 V PIN 6 PIN 2 5 V OR FLOATING

LP & LP-MDMechanical Details 250 Watt P3 & M3 Models See Airflow Curves U Channel FE3 Fan Assembly -+ -+ + - OUTPUT TERMINAL BLOCK M3.5 HARDWARE, 0.375 CENTRES A A 8.00 (203.2) OUTPUT HARDWARE 5.00 (127.0) 1.50 (38.1) 5.50 (139.7)1.50 (38.1) 0.75 (19.1) LOGIC CONNECTOR AMP PN 102617-3 6-32 UNC THD OUTPUT HARDWARE 0.75 (19.1) 5.50 (139.7)1.50 (38.1) 3.50 (88.9) 4X M4-0.7 THD 0.15 (3.8) MAX SCREW PENETRATION 2X M4-0.7 THD 0.15 (3.8) MAX SCREW PENETRATION AC INPUT CONNECTOR MOLEX PN 26-60-4050 CONTACT: MATING PLUG: MOLEX PN 09-50-3051 18-20AWG, MOLEX PN 08-52-0072 VIEW A-A 1.50 (39.7) .75 (19.1) 3.50 (88.9) 1.50 0.75 (19.1) AC INPUT

3 POSITION TERMINAL BLOCK

5.00 (127.0) 2X M4-0.7 THD 0.15 (3.8) MAX. SCREW PENETRATION 4X M4-0.7 THD 0.15 (3.8) MAX. SCREW PENETRATION L N GND 8.30 (210.8) 2.50 (63.5) M3-0.5 THD ADDITIONAL MTG. HOLE IF REQUIRED 0.15 (3.8) MAX. SCREW PENETRATION POWER SUPPLY OUTPUT TERMINATION AREA AIR FLOW 9.50 (241.3) Notes 1. Supplies are SEMI F47 at highline input (180-264) at 100% rated output power. Certification details available on request. 2. Mating connector kit available. Order part number LP CONN KIT. 3. Dimensions in inches (mm). Weight: 1.40 lb (0.64 kg) approx Weight: 1.90 lb (0.86 kg) approx

LP & LP-MDMechanical Details 350 Watt P4 & M4 Models See Airflow Curves U-Channel Notes FE4 Fan Assembly + - -+ + - OUTPUT TERMINAL BLOCK M3.5 HARDWARE, 0.375 CENTRES A A 6.00 (152.4) 9.00 (228.6) 6.00 (152.4) 5.00 (127.0) 1.50 (38.1) 1.50 (38.1) 0.75 (19.1) 0.75 (19.1) 1.50 (38.1) AMP PN 102617-3 LOGIC CONNECTOR OUTPUT HARDWARE 6-32 UNC THD 3.50 (88.9) 4X M4-0.7 THD 0.15 (3.8) MAX SCREW PENETRATION 0.15 (3.8) MAX SCREW PENETRATION 2X M4-0.7 THD L N GND MOLEX PN 26-60-4050 AC INPUT CONNECTOR CONTACT: MATING PLUG: MOLEX PN 09-50-3051 18-20AWG, MOLEX PN 08-52-0072 VIEW A-A 1.50 1.56 (39.7) 0.75 (19.1) 3.50 (88.9) 1.50 0.75 (19.1) AC INPUT 5.00 (127.0) 2X M4-0.7 THD 0.15 (3.8) MAX. SCREW PENETRATION 4X M4-0.7 THD 0.15 (3.8) MAX. SCREW PENETRATION L N GND 10.50 (266.7) 9.30 (236.2) 2.50 (63.5) M3-0.5 THD ADDITIONAL MTG. HOLE IF REQUIRED 0.15 (3.8) MAX. SCREW PENETRATION AIRFLOW 1. Supplies are SEMI F47 at highline input (180-264) at 100% rated output power. Certification details available on request. 2. Mating connector kit available. Order part number LP CONN KIT. 3. Dimensions in inches (mm). Weight: 1.50 lb (0.68 kg) approx Weight: 2.00 lb (0.91 kg) approx

ME4 Fan Assembly (M Models Only) 1.50 (38.1) 6.00 (152.4) 1.56 (39.7) 0.75 (19.1) 3.50 (88.9) 2.50 (63.5) 1.50 (38.1) 6.00 (152.4) 0.75 (19.1) AC INPUT 11.25 (285.8) 5.00 (127.0) 2X M4-0.7 THD 0.15 (3.8) MAX. SCREW PENETRATION 4X M4-0.7 THD 0.15 (3.8) MAX. SCREW PENETRATION M3-0.5 THD ADDITIONAL MTG. HOLE IF REQUIRED L N GND AIRFLOW LP & LP-MDMechanical Details 250/350 Watt M3 & M4 Notes 1. Supplies are SEMI F47 at highline input (180-264) at 100% rated output power. Certification details available on request. 2. Mating connector kit available. Order part number LP CONN KIT. 3. Dimensions in inches (mm). ME3 Fan Assembly (M Models Only) 1.50 1.56 (39.7) 0.75 (19.1) 3.50 (88.9) 2.50 (63.5) 1.50 0.75 (19.1) AC INPUT 10.25 (260.4) 5.00 (127.0) 2X M4-0.7 THD 0.15 (3.8) MAX. SCREW PENETRATION 4X M4-0.7 THD 0.15 (3.8) MAX. SCREW PENETRATION M3-0.5 THD ADDITIONAL MTG. HOLE IF REQUIRED 0.15 (3.8) MAX. SCREW PENETRATION 8.30 (210.8) L N GND AIRFLOW Weight: 2.00 lb (0.91 kg) approx Weight: 2.16 lb (0.98 kg) approx

LP & LP-MDMechanical Details 450 Watt P5 & M5 Models 450 Watts - P5 and M5 models are always shipped with a fan cover to ensure adequate cooling. ME5 Fan Assembly (M Models Only) 1.50 (38.1) 6.00 (152.4) 1.68 (42.5) 0.75 (19.1) 3.50 (88.9) 1.50 0.75 (19.1) AC INPUT

3 POSITION TERMINAL BLOCK POWER SUPPLY

5.00 (127.0) 2X M4-0.7 THD 0.15 (3.8) MAX. SCREW PENETRATION 4X M4-0.7 THD 0.15 (3.8) MAX. SCREW PENETRATION AIR FLOW L N GND 10.50 (266.7) L N G 1.50 (42.5) 0.75 (19.1) 3.50 (88.9) 2.50 (63.5) 1.50 0.75 (19.1) AC INPUT 11.75 (298.5) 5.00 (127.0) 2X M4-0.7 THD 0.15 (3.8) MAX. SCREW PENETRATION 4X M4-0.7 THD 0.15 (3.8) MAX. SCREW PENETRATION M3-0.5 THD ADDITIONAL MTG. HOLE IF REQUIRED 0.15 (3.8) MAX. SCREW PENETRATION 9.80 (248.9) AIR FLOW L N GND Notes FE5 Fan Assembly 1. Supplies are SEMI F47 at highline input (180-264) at 100% rated output power. Certification details available on request. 2. Mating connector kit available. Order part number LP CONN KIT. 3. Dimensions in inches (mm). Weight: 2.50 lb (1.14 kg) approx Weight: 2.62 lb (1.19 kg) approx

LP & LP-MDAirflow Curves - U-Channel Models OUTPUT TERMINAL BLOCK 6-32 0.375 CENTERS MULTI-OUTPUT POWER CONNECTOR LOGIC CONNECTOR 10 2 19 13 + - OP 3 VOLTAGE ADJUST OP 1 VOLTAGE ADJUST (BEHIND) OP 2 VOLTAGE ADJUST Output Connector Molex 39-01-2060 Pin Function

1 Output RTN V2

3 Output RTN V3

4 Output 2+

6 Output 3+

Logic Connector AMP 87631-5 Pin Function 1 +sense (V1) 2 -sense (V1) 3 +sense (V1)

4 Current share

6 Inhibit

7 -sense (V1)

8 DC OK

10 Power fail

V1 OUTPUT TERMINAL BLOCK (EUROSTYLE 10.16mm) WIDE RANGE: 6 TO 18 AWG WIRE STRIP LENGTH: 0.25” (6.35mm) TIGHTENING TORQUE: 7 IN-lbs LOGIC CONNECTOR 10 2 + - VOLTAGE ADJUST (BEHIND) OUTPUT TERMINAL BLOCK 6-32 0.375 CENTERS OUTPUT 2 VOLTAGE ADJUST OUTPUT 1 + +- - M4-0.7 THD OUTPUT TERMINALS LOGIC CONNECTOR VOLTAGE ADJUST (BEHIND) 10 2 + - Single Output (S) Dual Output (R) Dual Output (U) Triple Output (T) Logic Connector AMP 87631-5 Pin Function 1 +sense (V1) 2 -sense (V1) 3 +sense (V1) 7 -sense (V1) Logic Connector AMP 87631-5 Pin Function 1 +sense (V1) 2 -sense (V1) 3 +sense (V1) 7 -sense (V1) M3.5 0.375 CENTERS LOGIC CONNECTOR VOLTAGE ADJUST 10 2 + - Formula for converting CFM to LFM: LFM = CFM x 144 (total cross section of airflow path (Inches 2)) Formula for converting LFM to CFM: CFM = LFM x (total cross section of airflow path (Inches 2)) 400 350 300 250 200 150 100 0 25 50 70 Temperature (ºC) Power (Watts) P3 & M3 Models P4 & M4 Models 300 250 200 150 100 0 25 50 70 Temperature (ºC) Power (Watts) The curves denote chassis derating. Output modules must be derated by the same proportion. Output Module Connection Details

300 LFM

225 LFM

150 LFM

Weight: 0.50 lb (227 g) approx Weight: 0.52 lb (236 g) approx Weight: 0.62 lb (282 g) approx Weight: 0.70 lb (318 g) approx