MODEL: M2XR2 M2XR2 SPECIFICATIONS ES-5087 Rev.11 Page 1/4 http://www.m-system.co.jp/ Super-mini Signal Conditioners Mini-M Series RTD TRANSMITTER (PC programmable) Functions & Features

  • Accepts direct input from an RTD and provides a standard process signal
  • PC programmable
  • User’s temperature table can be used
  • Leadwire resistance compensation Typical Applications
  • Long distance transmission between the RTD and the transmitter
  • Combination with intrinsic safety barriers Model 23 (.91) (2.99) mm (inch) 124 (4.88) MODEL: M2XR2–[1][2]–[3][4]

ORDERING INFORMATION

  • Code number: M2XR2-[1][2]-[3][4] Specify a code from below for each [1] through [4]. (e.g. M2XR2-4Z1-R/BL/CE/Q) Input Code 4: Pt 100 (JIS ’97, IEC) setting will be used if the input code is not specified.
  • Temperature range (e.g. 0 – 500°C)
  • Output range (e.g. 4 – 20 mA DC)
  • Specify the specification for option code /Q (e.g. /C01/S01) [1] INPUT RTD (2- or 3-wire) 1: JPt 100 (JIS'89) 3: Pt 100 (JIS'89) 4: Pt 100 (JIS'97, IEC) 5: Pt 50 Ω (JIS'81) 6: Ni 508.4 Ω 7: Pt 1000 8: Ni 100 9: Cu 10 @25°C 0: Specify (Please provide a resistance table.) Note: Consult M-System for 2-wire RTD (Configurator software is used to change input type and temperature range.) [2] OUTPUT Current Z1: Range 0 – 20 mA DC Voltage V1: Range -2.5 – +2.5 V DC V2: Range -10 – +10 V DC (Configurator software is used to change output over the described range of the selected suffix code. For changing out of this range, set the Output Range Selectors inside the unit before software adjustment.) [3] POWER INPUT AC Power M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 47 – 66 Hz) (90 – 264 V for UL) DC Power R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) P: 110 V DC (Operational voltage range 85 – 150 V, ripple 10 %p-p max.) (110 V ±10 % for UL) [4] OPTIONS (multiple selections) Burnout blank: Upscale burnout /BL: Downscale burnout (UL not available) /BN: No burnout (UL not available) Standards & Approvals (must be specified) /N: Without CE or UL /CE: CE marking /UL: UL approval, CE marking Other Options blank: none /Q: Option other than the above (specify the specification) SPECIFICATIONS OF OPTION: Q (multiple selections) COATING (For the detail, refer to M-System's web site.) /C01: Silicone coating /C02: Polyurethane coating /C03: Rubber coating (UL not available) TERMINAL SCREW MATERIAL /S01: Stainless steel (UL not available)

MODEL: M2XR2 M2XR2 SPECIFICATIONS ES-5087 Rev.11 Page 2/4 http://www.m-system.co.jp/

RELATED PRODUCTS

  • PC configurator software (model: JXCON) Downloadable at M-System’s web site. A dedicated cable is required to connect the module to the PC. Please refer to the internet software download site or the users manual for the PC configurator for applicable cable types. GENERAL SPECIFICATIONS Construction: Plug-in Connection: M3 screw terminals (torque 0.8 N·m) Screw terminal: Chromated steel (standard) or stainless steel Housing material: Flame-resistant resin (black) Isolation: Input to output to power Overrange output: Approx. -15 to +115 % (Negative current output is not provided.) Manual zero adjustments: -5 to +5 % (factory setting: 0 %) Manual span adjustments: 95 to 105 % (factory setting: 100 %) Programming: Downloaded from PC; input type and range, output range, zero and span, simulating output, etc. Burnout: Upscale standard; downscale or no burnout optional by programming Linearization: Standard Status indicator LED: Blinking patterns indicate different operating status of the transmitter. Configurator connection: 2.5 dia. miniature jack; RS-232-C level INPUT SPECIFICATIONS Maximum leadwire resistance: 20 Ω per wire (3-wire) Sensing current: ≤ 1.0 mA Temperature range: See Table 1. If not specified, the input range is shown below. 1: JPt 100 (JIS '89) 0 – 100°C 3: Pt 100 (JIS '89) 0 – 100°C 4: Pt 100 (JIS '97, IEC) 0 – 100°C 5: Pt 50 Ω (JIS '81) 0 – 200°C 6:Ni 508.4 Ω 0 – 100°C 7: Pt 1000 0 – 100°C 8: Ni 100 0 – 100°C 9 :Cu 10 @25°C 0 – 100°C OUTPUT SPECIFICATIONS ■ DC Current Operational range: 0 – 24 mA DC Output range: 0 – 20 mA DC Minimum span: 1 mA Offset: Lower range can be any specific value within the output range provided that the minimum span is maintained. Load resistance: Output drive 15 V max. (e.g. 4 – 20 mA: 750 Ω [15 V ÷ 20 mA]) If not specified, the output range is 4 – 20 mA DC. ■ DC Voltage Code V1 (narrow spans) Operational range: -3 – +3 V DC Output range: -2.5 – +2.5 V DC Minimum span: 250 mV Code V2 (wide spans) Operational range: -11.5 – +11.5 V DC Output range: -10 – +10 V DC Minimum span: 1 V Offset: Lower range can be any specific value within the output range provided that the minimum span is maintained. Load resistance: Output drive 1 mA max. If not specified, the output range is shown below. V1: 0 – 1 V DC V2: 1 – 5 V DC INSTALLATION Power Consumption
  • AC: Approx. 3 VA at 100 V Approx. 4 VA at 200 V Approx. 5 VA at 264 V
  • DC: Approx. 2 W Operating temperature: -30 to +60°C (-22 to +140°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Surface or DIN rail Weight: 120 g (0.26 lb) PERFORMANCE Accuracy: Table 1 value or ±0.1 % of span, whichever is greater. Add 0.2 % when the output span equals 1/10 or narrower of the max. span. Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) of max. span at -5 to +55°C [23 to 131°F] Response time: ≤ 0.9 sec. (0 – 90 %) Burnout response: ≤ 10 sec. Line voltage effect: ±0.1 % over voltage range Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @1 minute (input to output to power to ground)

MODEL: M2XR2 M2XR2 SPECIFICATIONS ES-5087 Rev.11 Page 3/4 http://www.m-system.co.jp/ CALCULATION EXAMPLES OF OVERALL ACCURACY [Example 1] Input: Pt 100 (JIS ’97, IEC), 0 – 500°C Output: 4 – 20 mA DC 1) ±0.15°C referred from Table 1, is converted into % by the following equation: 0.15°C ÷ 500°C = 0.03%. 3) Output span 16 mA (= 20 mA – 4 mA) Max. span 20 mA Output span ≥ 1/10 of max. span ➠ No need of adding 0.2%. 4) Overall accuracy equals ±0.1% of span [Example 2] Input: Pt 100 (JIS ’97, IEC), 0 – 100°C Output: 2.0 – 2.5 V DC 1) ±0.15°C referred from Table 1, is converted into % by the following equation: 0.15°C ÷ 100°C = 0.15%. 3) Output span 0.5 V (= 2.5 V – 2.0 V) Max. span 5 V Output span ≤ 1/10 of max. span ➠ Add 0.2%. 4) Overall accuracy equals ±0.35% of span (0.15 + 0.2) Table 1. RTD MIN. SPAN ACCURACYUSABLE RANGE JPt 100 (JIS’89) Pt 100 (JIS’97 , IEC) Pt 100 (JIS’89) Pt 50Ω (JIS’81) Ni 508.4Ω Pt 1000 Ni 100 Cu 10 @25°C -200 to +500 -328 to +932 -200 to +850 -328 to +1562 -200 to +850 -328 to +1562 -200 to +649 -328 to +1200 -50 to +200 -58 to +392 -200 to +200 -328 to +392 -50 to +200 -58 to +392 -50 to +200 -58 to +392 ±0.15 ±0.27 ±0.15 ±0.27 ±0.15 ±0.27 ±0.15 ±0.27 ±0.15 ±0.27 ±0.15 ±0.27 ±0.15 ±0.27 ±0.50 ±0.90 STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 Low Voltage Directive EN 61010-1 Installation Category II Pollution Degree 2 Input or output to power: Reinforced insulation (300 V) Input to output: Basic insulation (300 V) RoHS Directive EN 50581 Approval: UL/C-UL nonincendive Class I, Division 2, Groups A, B, C, and D (ANSI/ISA-12.12.01, CAN/CSA-C22.2 No.213) UL/C-UL general safety requirements (UL 61010-1, CAN/CSA-C22.2 No.61010-1)

MODEL: M2XR2 M2XR2 SPECIFICATIONS ES-5087 Rev.11 Page 4/4 http://www.m-system.co.jp/ EXTERNAL VIEW UP/DOWN Switches The front cover cannot be turned open by 180 deg. when there is no extra space between units. Configurator Jack ■ FRONT VIEW (with cover open)Status Indicator LED Zero/Span Selector Top: SPAN Middle: OFF Bottom: ZERO ■ LEFT SIDE VIEW (with cover removed) Output Range Selectors [e.g.] Output code V1 O N 2 O SW2 ATT SW3 SW6 SW4 SW7 IV I V Refer to the instruction manual for detailed procedures. EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch) 21.5 (.85) 70.5 (2.78) 6 (.23) 59 (2.32) DIN RAIL 35mm wide [4 (.16)] 8–M3 SCREW 72 (2.83) 23 (.91) 2–4.2x5 (.17x.20) MTG HOLE 6 (.24) deep 116.7 (4.59)

  • When mounting, no extra space is needed between units. 14 13 4 (.16) SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM Isolation Base Socket Low Drift Amplifier & Burnout Output Driver OUTPUT Digital Computation ZERO/SPAN SELECTOR UP/DOWN SWITCHES CONFIGURATOR JACK U(+) V(–) POWER STATUS A B B RTD OUTPUT RANGE SELECTORS Specifications are subject to change without notice.