M2PP MSYSTEM | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

MODEL: M2PP M2PP SPECIFICATIONS ES-5061 Rev.22 Page 1/4 http://www.m-system.co.jp/ Super-mini Signal Conditioners Mini-M Series PULSE ISOLATOR Functions & Features

  • Galvanically isolates pulse rate signals
  • Input frequency = output frequency
  • Various outputs (open collector, voltage pulses and dry contact AC/DC switch) Typical Applications
  • Isolating field pulse signals in order to reduce noises
  • Changing e.g. dry contact signal to e.g. 5 V signals Model 23 (.91) (2.99) 124 (4.88) mm (inch) MODEL: M2PP–[1][2][3]–[4][5]

ORDERING INFORMATION

  • Code number: M2PP-[1][2][3]-[4][5] Specify a code from below for each of [1] through [5]. (e.g. M2PP-33N-M2/CE/Q)
  • Specify the specification for option code /Q (e.g. /C01/S01) [1] INPUT 1: Mechanical contact (max. 30 Hz) 2: Open collector (max. 10 kHz) 3: Voltage pulse (max. 10 kHz) 9: Clamp-on pulse sensor CLSP (‘/UL’ is not selectable for ‘Standards & Approvals’ code.) [2] OUTPUT 1: Low frequency open collector (max. 30 Hz) 2: High frequency open collector (max. 10 kHz) 3: 5 V pulse (max. 10 kHz) 4: 12 V pulse (max. 10 kHz) 5: 24 V pulse (max. 10 kHz) 7: Dry contact AC/DC switch (max. frequency 30 Hz) (‘/UL’ is not selectable for ‘Standards & Approvals’ code.) [3] OUTPUT LOGIC N: The same as the input R: Inverted [4] POWER INPUT AC Power M: 85 – 264 V AC (Operational voltage range 85 – 264 V, 47 – 66 Hz) (Select ‘/N’ for ‘Standards & Approvals’ code.) M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 47 – 66 Hz) (‘/UL’ is not selectable for ‘Standards & Approvals’ code.) DC Power R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) R2: 11 – 27 V DC (Operational voltage range 11 – 27 V, ripple 10 %p-p max.) (Select ‘/N’ for ‘Standards & Approvals’ code.) P: 110 V DC (Operational voltage range 85 – 150 V, ripple 10 %p-p max.) (‘/UL’ is not selectable for ‘Standards & Approvals’ code.) [5] OPTIONS (multiple selections) Standards & Approvals (must be specified) /N: Without CE or UL /CE: CE marking /UL: UL approval, CE marking Other Options blank: none /Q: Option other than the above (specify the specification) SPECIFICATIONS OF OPTION: Q (multiple selections) COATING (For the detail, refer to M-System's web site.) /C01: Silicone coating /C02: Polyurethane coating /C03: Rubber coating (UL not available) TERMINAL SCREW MATERIAL /S01: Stainless steel (UL not available)

RELATED PRODUCTS

  • Clamp-on pulse sensor (model: CLSP)

MODEL: M2PP M2PP SPECIFICATIONS ES-5061 Rev.22 Page 2/4 http://www.m-system.co.jp/ GENERAL SPECIFICATIONS Construction: Plug-in Connection: M3 screw terminals (torque 0.8 N·m) Screw terminal: Chromated steel (standard) or stainless steel Housing material: Flame-resistant resin (black) Isolation: Input to output to power Frequency range: Input and output are the same. Chattering protection: Filter provided for mechanical contact input Input pulse sensing: DC coupled INPUT SPECIFICATIONS Excitation: 12 V DC @30 mA; shortcircuit protection ■ Open Collector Maximum frequency: 10 kHz Pulse width time requirement: 10 μsec. min. for ON and OFF Sensing: Approx. 12 V DC @3 mA ON/OFF level: ≤ 600 Ω / 1.8 V for ON, ≥ 100 kΩ / 3.5 V for OFF ■ Mechanical Contact Maximum frequency: 30 Hz Pulse width time requirement: 10 msec. min. for ON and OFF Sensing: Approx. 12 V DC @3 mA ON/OFF level: ≤ 200 Ω / 0.6 V for ON, ≥ 100 kΩ / 2.5 V for OFF ■ Voltage Pulse Maximum frequency: 10 kHz Pulse width time requirement: 10 μsec. min. for high and low levels Waveforms: Square or sine Hi/Lo level: 2 – 50 V for high level; ≤1 V for low level Input impedance: 10 kΩ min. ■ Clamp-on Pulse Sensor CLSP Maximum frequency: 50 000 pulses/hour ON/OFF level: ≤ 400 Ω / 1.3 V for ON, ≥ 200 kΩ / 12 V for OFF OUTPUT SPECIFICATIONS ■ Low Frequency Open Collector:

50 V DC @100 mA (resistive load)

Maximum frequency: 30 Hz Timer: Limits ≥ 75 msec. within 75 ±25 msec. ON time for output logic non-inverted OFF time for output logic inverted Saturation voltage: 0.5 V DC ■ High Frequency Open Collector: Maximum frequency: 10 kHz Saturation voltage: 0.5 V DC ■ Voltage Pulse Maximum frequency: 10 kHz High level: Rating (5, 12 or 24 V) ±10 % Low level: ≤ 0.5V Load resistance: ≥ 250 Ω for 5 V ≥ 600 Ω for 12 V ≥ 1200 Ω for 24 V ■ Dry Contact AC/DC Switch

132 V AC @200 mA (cos ø = 1)

30 V DC @200 mA (resistive load)

Maximum frequency: 30 Hz Timer: Limits within 75 ±25 msec. for wider than 75 msec. pulses ON time for output logic non-inverted OFF time for output logic inverted Saturation voltage: 3 V DC INSTALLATION Power Consumption

  • AC: Approx. 3 VA at 100 V Approx. 4 VA at 200 V Approx. 5 VA at 264 V
  • DC: Approx. 3 W Operating temperature: -5 to +55°C (23 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Surface or DIN rail Weight: 150 g (0.33 lb) PERFORMANCE Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @1 minute (input to output to power to ground) STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4

MODEL: M2PP M2PP SPECIFICATIONS ES-5061 Rev.22 Page 3/4 http://www.m-system.co.jp/ EMS EN 61000-6-2 Low Voltage Directive EN 61010-1 Measurement Category II (output) Installation Category II (power) Pollution Degree 2 Input or output to power: Reinforced insulation (300 V) Input to output: Basic insulation (300 V) RoHS Directive EN 50581 Approval: UL/C-UL nonincendive Class I, Division 2, Groups A, B, C, and D (ANSI/ISA-12.12.01, CAN/CSA-C22.2 No.213) UL/C-UL general safety requirements (UL 61010-1, CAN/CSA-C22.2 No.61010-1) OUTPUT LOGIC OFF OFF HH H H OFF ON OFF ON H L H L OFF ON OFF ON ON LL L L ON INPUT TYPE Voltage Pulse Mechanical Contact Open Collector Clamp-on Pulse Sensor CLSP PULSE LOGIC Non Inverted Inverted Non Inverted Inverted INPUT VOLTAGE PULSE OUTPUT OPEN COLLECTOR DRY CONTACT AC/DC SWITCH EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch) 21.5 (.85) 70.5 (2.78) 6 (.23) 59 (2.32) DIN RAIL 35mm wide [4 (.16)] 8–M3 SCREW 72 (2.83) 23 (.91) 2–4.2x5 (.17x.20) MTG HOLE 6 (.24) deep 114 (4.49)

  • When mounting, no extra space is needed between units. 14 13 4 (.16)

MODEL: M2PP M2PP SPECIFICATIONS ES-5061 Rev.22 Page 4/4 http://www.m-system.co.jp/ SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM 4kΩ ■ Mechanical Contact, Open Collector or Clamp-on Pulse Sensor CLSP Input Connection Examples +12V ■ Voltage Pulse +12V ■ Open Collector Output Connection Examples ■ Voltage Pulse PWR PWR + 5 + 5 Isolation Base Socket Waveform Shaper Output Driver OUTPUT U(+) V(–) POWER 12V Supply INPUT SENSOR EXCITATION Timer * Low freq. open collector and dry contact AC/DC switch output only. U ■ Dry Contact AC/DC Switch

  • AC Powered LOAD Relay or Counter Coil Varistor or Spark Quenching Circuit
  • DC Powered LOAD Relay or Counter Coil Spark Quenching Diode Specifications are subject to change without notice.