MODEL: M2BD M2BD SPECIFICATIONS ES-5002 Rev.10 Page 1/7 http://www.m-system.co.jp/ Super-mini Signal Conditioners Mini-M Series COMMUNICATION CONTROLLER (DeviceNet) Functions & Features
- Receiving up to 16 Mini-M modules
- Enabling interfacing analog I/Os to DeviceNet
- Power supplied through printed wiring on the base SPANSPAN Model SPAN ZERO Model SPAN ZERO Model SPAN ZERO Model SPAN ZERO Model SPAN ZERO Model ZERO Model ZERO Model SPAN ZERO Model SPAN ZERO Model SPAN ZERO Model SPAN ZERO Model SPAN ZERO Model SPAN ZERO Model SPAN ZERO Model SPAN ZERO Model SPAN ZERO MODEL: M2BD–[1][2]-[3][4]
ORDERING INFORMATION
- Code number: M2BD-[1][2]-[3][4] Specify a code from below for each of [1] through [4]. (e.g. M2BD-161-R/UL) Power input specification for each I/O modules must be the same as that of the base. [1] CAPACITY 04: 4 positions 08: 8 positions 16: 16 positions [2] I/O TYPE 1: Input 2: Output [3] POWER INPUT AC Power K: 85 – 132 V AC (Operational voltage range 85 – 132 V, 47 – 66 Hz) (CE or UL not available) DC Power R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) [4] OPTIONS Standards & Approvals blank: Without UL or CE /UL: UL approval, CE marking
RELATED PRODUCTS
- Programming Unit (model: PU-2x) GENERAL SPECIFICATIONS Capacity: 4, 8 or 16 positions Connection DeviceNet: Euro type connector terminal (applicable wire size: 0.2 to 2.5 mm2, stripped length 7 mm) I/O: M3 screw terminals (torque 0.8 N·m) Power input: M3 screw terminals (torque 0.8 N·m) Screw terminal: Nickel-plated steel Isolation: I/O to DeviceNet to power to FG1 Power indicator: Green LED turns on with power supplied. DeviceNet COMMUNICATION Transmission cable: Approved for DeviceNet Node address setting: DIP switch; 00 – 63 Baud rate setting: DIP switch 125 kbps (factory default), 250 kbps, 500 kbps MS (Module Status) indicator: Bi-color (green/red) LED indicates device status. NS (Network Status) indicator: Bi-color (green/red) LED indicates status of the communication link. INPUT SPECIFICATIONS Input modules: Mini-M series; output 1 – 5 V DC; (Each input must be isolated by signal conditioners. Non- isolated modules such as M2BW is not usable.) ■ Analog Input Input range: See each I/O module spec. Voltage at the field I/O terminals limited within 30 V DC for UL. Isolation: transformer (by Mini-M module) A/D conversion output: 16-bit binary Signal range 0 – 100 % is converted into hexadecimal 0000 – 1770 (0 – 6000). -15 to 0 % is represented by 2’s complements. Overall range is represented by hexadecimal FC7C – 1AF4 Note: In the firmware version 3.00 or later, analog input range 0 – 100% can be converted into hexadecimal 0000 – 2710 (0 – 10000). In addition, negative values of analog input range -15 to 0% can be converted into signed absolute values. Refer to the instruction manual for details. OUTPUT SPECIFICATIONS Output modules: Model M2VS; input 1 – 5 V DC ■ Analog Output Output range: See model M2VS spec.
MODEL: M2BD M2BD SPECIFICATIONS ES-5002 Rev.10 Page 2/7 http://www.m-system.co.jp/ Isolation: Transformer D/A conversion output: 16-bit binary Signal range 0 – 100 % is converted into hexadecimal 0000 – 1770 (0 – 6000). -15 to 0 % is represented by 2’s complements. Overall range is represented by hexadecimal FC7C – 1AF4 (- Note: In the firmware version 3.00 or later, analog output range 0 – 100% can be converted into hexadecimal 0000 – 2710 (0 – 10000). In addition, negative values of analog output range -15 to 0% can be converted into signed absolute values. Refer to the instruction manual for details. INSTALLATION Power Consumption:
- AC: approx. 6 VA without I/O module approx. 30 VA with 4 modules (M2DY) approx. 50 VA with 8 modules (M2DY) approx. 90 VA with 16 modules (M2DY) Current consumption:
- DC approx. 0.25 A without I/O module approx. 1 A with 4 modules (M2DY) approx. 1.5 A with 8 modules (M2DY) approx. 2.5 A with 16 modules (M2DY) Supply voltage to network: 11 – 25 V DC supplied through the network terminal block Supply current to network: 60 mA max. @ 24 V Operating temperature: -5 to +55°C (23 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Atmosphere: No corrosive gas or heavy dust Mounting: Surface Weight: Without I/O module M2BD-04 1.2 kg (2.6 lb) M2BD-08 1.5 kg (3.3 lb) M2BD-16 2 kg (4.4 lb) PERFORMANCE in percentage of span A/D conversion: Accuracy of input module ±0.1% D/A conversion: Accuracy of M2VS ±0.1 % Permissible power failure duration: ≤ 10 msec. Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 1000 V AC @1 minute (power to I/O module to DeviceNet module to FG1) STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 Low Voltage Directive EN 61010-1 Measurement Category II (input) Pollution Degree 2 Input or output to power: Reinforced insulation (300 V) Input to output: Basic insulation (300 V) RoHS Directive EN 50581 Approval: UL/C-UL nonincendive Class I, Division 2, Groups A, B, C, and D (ANSI/ISA-12.12.01, CAN/CSA-C22.2 No.213) UL/C-UL general safety requirements (UL 3111-1, CAN/CSA-C22.2 No.1010-1)
MODEL: M2BD M2BD SPECIFICATIONS ES-5002 Rev.10 Page 3/7 http://www.m-system.co.jp/ COMM. MODULE FRONT PANEL PWR MS NS NA1 NA0 NA2 NA3 NA4 NA5 DR0 DR1 ON Node Address Setting Baud Rate Setting NS Indicator LED Euro Type Connector Terminal for DeviceNet MS Indicator LED Power LED PU-2x Modular Jack Refer to the instruction manual for detailed procedures. EXTERNAL DIMENSIONS unit: mm (inch) ■ M2BD-041 (INPUT BASE) 1 2 3 4 5 8 1 4 5 8 1 4 5 8 1 4 5 8 1 4 FG1 13 14 CH4CH1 130 (5.12) 100 (3.94) 6 (.24) 170 (6.69) 190 (7.48) 210 (8.27) 27 (1.06) 2–M3 POWER TERMINALS CT PROTECTOR (CTM2) 16–M3 INPUT TERMINALS 125 (4.92) * 130 (5.12) * 165 (6.50) required for pneumatic tubing for M2PV. ** Attached to M2CA and M2CE.
MODEL: M2BD M2BD SPECIFICATIONS ES-5002 Rev.10 Page 4/7 http://www.m-system.co.jp/ ■ M2BD-042 (OUTPUT BASE) FG1 13 14 1 2 3 4 CH1 CH2 CH3 CH4 9 12 9 12 9 12 9 12 6 (.24) 8–M3 OUTPUT TERMINALS 2–M3 POWER TERMINALS 125 (4.92) 100 (3.94) 170 (6.69) 190 (7.48) 210 (8.27) ■ M2BD-081 (INPUT BASE) 1 2 3 4 5 6 7 8 5 8 1 4 5 8 1 4 5 8 1 4 5 8 1 4 5 8 1 4 5 5 8 8 1 4 1 4 CH7CH1 5 8 1 4 FG1 13 14 CH8 130 (5.12) 100 (3.94) 6 (.24) 260 (10.24) 280 (11.02) 300 (11.81) 27 (1.06) 2–M3 POWER TERMINALS 32–M3 INPUT TERMINALS 125 (4.92) * 130 (5.12) CT PROTECTOR (CTM2)** * 165 (6.50) required for pneumatic tubing for M2PV. ** Attached to M2CA and M2CE.
MODEL: M2BD M2BD SPECIFICATIONS ES-5002 Rev.10 Page 5/7 http://www.m-system.co.jp/ ■ M2BD-082 (OUTPUT BASE) FG1 13 14 1 2 3 4 5 6 7 8 9 12 CH3 CH4 CH5 CH6 CH7 CH8 9 12 9 12 CH1 CH2 9 12 9 12 9 12 9 12 9 12 6 (.24) 16–M3 OUTPUT TERMINALS 130 (5.12) 100 (3.94) 260 (10.24) 280 (11.02) 300 (11.81) 125 (4.92) 130 (5.12) 2–M3 POWER TERMINALS ■ M2BD-161 (INPUT BASE) 5 8 1 4 5 8 1 4 5 8 1 4 5 8 1 4 5 8 1 4 5 8 CH5CH1 5 8 1 4 5 8 1 4 5 8 1 4 5 8 1 4 5 8 FG1 1 4 13 14 1 2 3 4 5 5 85 85 85 85 8 6 7 8 9 10 1 41 41 41 41 4 11 12 13 14 15 16 CH10CH6 CH16CH11 130 (5.12) 100 (3.94) 6 (.24) 440 (17.32) 460 (18.11) 480 (18.90) 27 (1.06) 2–M3 POWER TERMINALS 64–M3 INPUT TERMINALS 125 (4.92) * 130 (5.12) CT PROTECTOR (CTM2)** * 165 (6.50) required for pneumatic tubing for M2PV. ** Attached to M2CA and M2CE.
MODEL: M2BD M2BD SPECIFICATIONS ES-5002 Rev.10 Page 6/7 http://www.m-system.co.jp/ ■ M2BD-162 (OUTPUT BASE) FG1 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 9 12 CH11 CH12 CH13 CH14 CH15 CH16 9 12 9 12 9 12 9 12 9 12 9 12 CH6 CH7 CH8 CH9 CH10 9 12 9 12 9 12 9 12 9 12 CH1 CH2 CH3 CH4 CH5 9 12 9 12 9 12 9 12 6 (.24) 32–M3 OUTPUT TERMINALS 130 (5.12) 100 (3.94) 440 (17.32) 460 (18.11) 480 (18.90) 2–M3 POWER TERMINALS 125 (4.92) 130 (5.12) MOUNTING REQUIREMENTS unit: mm (inch) ■ M2BD-04 100 (3.94) 190 (7.48) 4–M5 SCREW ■ M2BD-08 100 (3.94) 280 (11.02) 4–M5 SCREW ■ M2BD-16 100 (3.94) 460 (18.11) 4–M5 SCREW
MODEL: M2BD M2BD SPECIFICATIONS ES-5002 Rev.10 Page 7/7 http://www.m-system.co.jp/ SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM Note: In order to improve EMC performance, bond the FG1 terminal to ground. Caution: FG1 terminal is NOT a protective conductor terminal. Ch.1 INPUT Ch.16 INPUT ISOLATION Ch.2 INPUT ISOLATION ISOLATION A / D or D / A Conv. I / O CPU Communication CPU SERIAL TRANSMISSION LINE MODULAR JACK DIP SW INDCATOR LEDV+ CAN_H Drain CAN_L U(+) V(–) POWER To Other DeviceNet Devices ■ INPUT BASE Ch.1 OUTPUT Ch.16 OUTPUT Ch.2 OUTPUT ■ OUTPUT BASE I/O MODULESCOMMUNICATION MODULE FG1 PU-2x Specifications are subject to change without notice.