XA-SERIES IDEC | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 64
Technical content
Emergency Stop Switches (Selection Guide) Series Emergency Stop Switch Name ø16mm X6 Series Pushlock Pull / Turn Reset (Unibody) ø16mm XA Series Pushlock Pull / Turn Reset (Unibody) ø16mm XA Series Pushlock Pull / Turn Reset (with Removable Contact Block) ø22mm XW Series Pushlock Pull / Turn Reset ø22mm HW Series Pushlock Turn Reset (Unibody) (Plastic/Flush Bezel) Shape Safety Category 4 4 4 4 4 Applicable Standards EN60947-5-5 UL508 CSA C22.2 No.14 GB14048.5 EN60947-5-5 UL508 CSA C22.2 No.14 GB14048.5 EN60947-5-5 UL508 UL991 NFPA79 CSA C22.2 No.14 GB14048.5 EN60947-5-5 UL508 UL991 NFPA79 CSA C22.2 No.14 GB14048.5 EN60947-5-5 UL508 CSA C22.2 No.14 GB14048.5 Mark Page 8 13 15 21 32 Series Emergency Stop Switch Name ø22mm HW Series Pushlock Turn Reset (with Removable Contact Block) ø22mm HW Series Pushlock Key Reset ø22mm HW Series Push-Pull ø22mm YW Series Pushlock Pull / Turn Reset Shape Safety Category 4 4 4 4 Applicable Standards EN60947-5-5 UL508 CSA C22.2 No.14 GB14048.5 EN60947-5-5 UL508 CSA C22.2 No.14 GB14048.5 EN60947-5-5 UL508 CSA C22.2 No.14 GB14048.5 EN60947-5-5 UL508 CSA C22.2 No.14 GB14048.5 Mark Page 34 35 35 40 Series Emergency Stop Switch Name ø30mm XN Series Pushlock Pull / Turn Reset (Plastic/Flush Bezel) ø30mm XN Series Pushlock Turn Reset (Padlockable) ø30mm HN Series Pushlock Turn Reset (Unibody) Shape Safety Category 4 4 4 Applicable Standards EN60947-5-5 UL508 UL991 NFPA79 CSA C22.2 No.14 GB14048.5 EN60947-5-5 UL508 UL991 NFPA79 CSA C22.2 No.14 GB14048.5 EN60947-5-5 UL508 CSA C22.2 No.14 GB14048.5 Mark Page 48 50 55
Emergency Stop Switches (Selection Guide) Series SEMI Emergency Off (EMO) Switch Name ø16mm XA Series EMO Switch Pushlock Pull / Turn Reset ø22mm XW Series EMO Switch Pushlock Pull / Turn Reset ø22 HW Series EMO Switch Pushlock Turn Reset Switch Guard for ø16mm XA Series ø22mm HW/XW Series Shape Safety Category 4 4 4 — Applicable Standards EN60947-5-5 UL508 CSA C22.2 No.14 GB14048.5 EN60947-5-5 UL508 CSA C22.2 No.14 GB14048.5 EN60947-5-5 UL508 CSA C22.2 No.14 GB14048.5 SEMI S2 0706 Mark — Page 58 58 58 60 Series Stop Switch Name ø16mm XA Series Pushlock Pull / Turn Reset (with Removable Contact Block) ø16mm XA Series Pushlock Pull / Turn Reset (Unibody) ø22 XW Series Pushlock Pull / Turn Reset ø22 HW Series Pushlock Turn Reset Pushlock Pull White Switch Guard for ø22mm HW/XW Series Shape Safety Category — Applicable Standards EN60947-5-1 UL508 CSA C22.2 No.14 GB14048.5 EN60947-5-1 UL508 CSA C22.2 No.14 GB14048.5 EN60947-5-1 UL508 CSA C22.2 No.14 GB14048.5 UL508 CSA C22.2 No.14 EN60947-5-5 GB14048.5 Mark — Page 62 62 63 63 64
Emergency Stop Switches Selection Diagram Pushlock Pull or Turn Reset Pushlock Pull or Turn Reset Pushlock Pull or Turn Reset Pushlock Pull or Turn Reset Pushlock Pull or Turn Reset Detachable Contact Block Detachable Contact Block Detachable Contact Block Detachable Contact Block ø40mm Button ø40mm Button ø40mm Button ø29mm Button ø40mm Button Unibody ø40mm Button ø29mm Button ø29mm Button Reverse Energy Structure Safe Break Action Reverse Energy Structure Safe Break Action ø22mm Mount Hole ø16mm Mount Hole Non illuminated Non illuminated Illuminated Illuminated ø60mm Button ISO 13850 4.4.1 mushroom-type push-buttons ISO 13850 4.4.4 The command shall be maintained by engagement (latching-in) of the actuating means. ISO 13850 4.4.4 The actuator of the emergency stop device shall be colored red. IEC 60947-5-5 5. Electrical requirements
5.2 All normally
(positive opening action, according to annex K of IEC 60947-5-1. ISO 13850 4.4.6 As far as a background exists behind the actuator and as far as is practicable, it shall be colored yellow. Emergency Stop Switch Continued on Next Page (no safe break action) Model Applicable Standards Mark Page XA1E-BV3 (Solder, PC Board Terminal) EN60947-5-5 UL508/UL991 NFPA79 CSA C22.2 No.14 GB14048.5 XA1E-BV4 (Solder, PC Board Terminal) EN60947-5-5 UL508/UL991 NFPA79 CSA C22.2 No.14 GB14048.5 AB6E-3BV (Solder Terminal) EN60947-5-5 UL508 CSA C22.2 No.14 GB14048.5 XA1E-BV3U (Solder, Solder/ Tab #110 Terminal) EN60947-5-5 UL508 CSA C22.2 No.14 GB14048.5 AB6E-4BV (Solder Terminal) EN60947-5-5 UL508 CSA C22.2 No.14 GB14048.5 XA1E-BV4U (Solder, Solder/ Tab #110 Terminal) EN60947-5-5 UL508 CSA C22.2 No.14 GB14048.5 XA1E-LV3 (Solder, PC Board Terminal) EN60947-5-5 UL508/UL991 NFPA79 CSA C22.2 No.14 GB14048.5 XA1E-LV4 (Solder, PC Board Terminal) EN60947-5-5 UL508/UL991 NFPA79 CSA C22.2 No.14 GB14048.5 XW1E-BV4 (Screw Terminal) EN60947-5-5 UL508/UL991 NFPA79 CSA C22.2 No.14 GB14048.5 XW1E-BV4 (Solder, PC Board Terminal) EN60947-5-5 UL508/UL991 NFPA79 CSA C22.2 No.14 GB14048.5 XW1E-BV4 (Connector) EN60947-5-5 UL508 XW1E-BV5 (Screw Terminal) EN60947-5-5 UL508/UL991 NFPA79 CSA C22.2 No.14 GB14048.5 XW1E-LV4 (Screw Terminal) EN60947-5-5 UL508/UL991 NFPA79 CSA C22.2 No.14 GB14048.5 XW1E-LV4 (Solder, PC Board Terminal) EN60947-5-5 UL508/UL991 NFPA79 CSA C22.2 No.14 GB14048.5 ISO / IEC Standards and Emergency Stop Switches
Emergency Stop Switches Selection Diagram Pushlock Pull or Turn Reset Detachable Contact Block Detachable Contact Block Detachable Contact Block Pushlock Pull or Turn Reset Pushlock Pull or Turn Reset Pushlock Turn Reset Pushlock Turn Reset Pushlock Turn Reset ø30mm Mount Hole Padlock- able Padlock- able Padlock- able ø40mm Button ø40mm Button ø44mm Button ø40mm Button ø44mm Button Plastic Bezel Flush Bezel Plastic Bezel Flush Bezel Plastic Bezel Flush Bezel ø60mm Button ø44mm Button Non illuminated Push-ON Illuminated Continued on Next Page Pushlock Pull or Turn Reset Detachable Contact Block ø40mm ButtonPush-ON Reverse Energy Structure Safe Break Action Model Applicable Standards Mark Page XW1E-TV4 (Screw Terminal) EN60947-5-5 UL508/UL991 NFPA79 CSA C22.2 No.14 GB14048.5 XW1E-TV4 (Connector) EN60947-5-5 UL508 23 XN1E-BV4 (Plastic Bezel) EN60947-5-5 UL508/UL991 NFPA79 CSA C22.2 No.14 GB14048.5 XN5E-BV4 (Flush Bezel) EN60947-5-5 UL508/UL991 NFPA79 CSA C22.2 No.14 GB14048.5 XN1E-BV5 (Plastic Bezel) EN60947-5-5 UL508/UL991 NFPA79 CSA C22.2 No.14 GB14048.5 XN4E-BL4 (Padlockable) EN60947-5-5 UL508/UL991 NFPA79 CSA C22.2 No.14 GB14048.5 XN1E-LV4 (Plastic Bezel) EN60947-5-5 UL508/UL991 NFPA79 CSA C22.2 No.14 GB14048.5 XN5E-LV4 (Flush Bezel) EN60947-5-5 UL508/UL991 NFPA79 CSA C22.2 No.14 GB14048.5 XN4E-LL4 (Padlockable) EN60947-5-5 UL508/UL991 NFPA79 CSA C22.2 No.14 GB14048.5 XN1E-TV4 (Plastic Bezel) EN60947-5-5 UL508/UL991 NFPA79 CSA C22.2 No.14 GB14048.5 XN5E-TV4 (Flush Bezel) EN60947-5-5 UL508/UL991 NFPA79 CSA C22.2 No.14 GB14048.5 XN4E-TL4 (Padlockable) EN60947-5-5 UL508/UL991 NFPA79 CSA C22.2 No.14 GB14048.5
Emergency Stop Switches Selection Diagram Accessories ø16mm Mount Hole ø22mm Mount Hole ø30mm Mount Hole Emergency Stop Nameplate Pushlock Pull or Turn Reset Pushlock Turn Reset Pushlock Turn Reset Pushlock Turn Reset Pushlock Turn Reset Pushlock Key ResetPushlock Pull Reset ø29mm Button ø40mm Button ø40mm Buttonø40mm Buttonø40mm Button Pushlock Turn Reset ø40mm Button Pushlock Turn Reset ø40mm Button ø40mm Button ø40mm Button ø40mm Button ø60mm Button ø22mm Mount Hole Detachable Contact Block Unibody Unibody Unibody Unibody ø30mm Mount Hole Non illuminated Non illuminated Illuminated Illuminated Detachable Contact Block Model Applicable Standards Mark Page YW1B-V4 EN60947-5-5 UL508 CSA C22.2 No.14 GB14048.5 HW1B-V3 EN60947-5-5 UL508 CSA C22.2 No.14 GB14048.5 HW1B-V4 EN60947-5-5 UL508 CSA C22.2 No.14 GB14048.5 HW1B-V5 EN60947-5-5 UL508 CSA C22.2 No.14 GB14048.5 HW1B-X4 EN60947-5-5 UL508 CSA C22.2 No.14 GB14048.5 HW1B-Y2 EN60947-5-5 UL508 CSA C22.2 No.14 GB14048.5 HW1E-BV4 EN60947-5-5 UL508 CSA C22.2 No.14 GB14048.5 YW1L-V4 EN60947-5-5 UL508 CSA C22.2 No.14 GB14048.5 HW1E-LV4 EN60947-5-5 UL508 CSA C22.2 No.14 GB14048.5 HN1E-BV4 EN60947-5-5 UL508 CSA C22.2 No.14 GB14048.5 HN1E-LV4 EN60947-5-5 UL508 CSA C22.2 No.14 GB14048.5 HAAV IEC 60947-5-5 IEC 60204-1 HWAV HNAV
ø16mm mounting hole Red button ø22mm mounting hole ø30mm mounting hole Switch and Background Color Selection Chart (IEC/SEMI/SEMATECH) Switch Applicable Nameplate (Note 1) Applicable Switch Guard XA1E HA1E HA1B-V HAAV-0, HAAV-27 HAAV4-0 HAAV4-27 N/A XW1E HW1E HW1B-V, HW1B-X HW1B-Y HWAV-0-Y , HWAV-27-Y HWAV5-0 HWAV5-27 HWAV5F-27 N/A XN1E XN4E XN5E HN1E HNAV-0 HNAV-27 N/A Switch Applicable Nameplate (Note 1) / EMO label Applicable Switch Guard SEMI SEMATECH XA1E-BV4∗∗RH-EMO HAAV4-0 XA9Z-KG1 (Note 2) XW1E-BV4∗∗RH-EMO HW1B-V4∗∗R-EMO HWAV-0-Y HW9Z-KG1 (Note 2) HW9Z-KG2 (Note 2) HW9Z-KG3 (Note 2) HW9Z-KG4 (Note 2) HW9Z-KG5 HW9Z-KG2 (Note 2) HW9Z-KG4 (Note 2) HW9Z-KG5 XW1E-BV4∗∗RH-EMO HW1B-V4∗∗R-EMO HWAV-0-Y HW9Z-KG5-W HW9Z-KG5-W XA1E HA1E HA1B-V HAAV-0, HAAV4-0 in combination with HW9Z-EMO-NPP XA9Z-KG1 (Note 2) XW1E HW1E HW1B-V (Note 4) HW1B-X HW1B-Y HWAV-74-Y , HWAV-0-Y in combination with HW9Z-EMO-NPP HW9Z-KG1 (Note 2) HW9Z-KG2 (Note 2) HW9Z-KG3 (Note 2) HW9Z-KG4 (Note 2) HW9Z-KG5 (Note 3) HW9Z-KG2 (Note 2) HW9Z-KG4 (Note 2) HW9Z-KG5 (Note 3) XW1E HW1E HW1B-V (Note 4) HW1B-X HW1B-Y HWAV-74-Y , HWAV-0-Y in combination with HW9Z-EMO-NPP HW9Z-KG5-W (Note 3) HW9Z-KG5-W (Note 3) XN1E XN4E XN5E HN1E HNAV-0 in combination with HW9Z-EMO-NPP Emergency Stop IEC 60947-5-5 IEC 60204-1 ISO 13850
- Red colored
- Mushroom
- Yellow background
- Shall be positioned for easy access Switch Applicable Nameplate Applicable Switch Guard XA1E-BV∗∗∗Y HA1E-V2S∗Y HAAV-0-W HAAV4-0-W XW1E-BV4∗∗Y HW1B-V∗∗∗Y HW1B-Y2∗∗Y HWAV-0-W HWAV5-0-W HW9Z-KG4-W (Note 2) HW9Z-KG5-W (Note 3) Note 1: Marking plate legend -0 (blank), -27 (EMERGENCY STOP), -74 (EMERGENCY OFF) Note 2: Cannot be used with a nameplate. Note 3: Cannot be used with HWAV5-∗. Note 4: HW1B-V5 switch cannot be used with a switch guard. Emergency Off (EMO) SEMI S2-0706
- Red and mushroom shaped button
- Yellow background
- EMO or Emergency Off labeled Local/Partial Shut Down SEMI S26-0308
- Should not use the combination of red button with yellow background
- Should not be la- beled as "EMO" or "Emergency Off," or the equivalent. Emergency Off (EMO) SEMATECH Applica- tion Guide for SEMI S2-93 Red and mushroom shaped button
- Yellow background
- EMO or Emergency Off labeled When installing a guard
- Guard diameter ø75mm minimum
- Button recessed from the guard no more than 3mm ø16mm mount- ing hole ø16mm mount- ing hole ø16mm mount- ing hole Yellow guard Yellow Button White guard ø22mm mount- ing hole ø22mm mount- ing hole ø22mm mount- ing hole ø30mm mounting hole Red button (EMO marking) Red button Note: Stop switch (yellow but- ton) should not be labeled as “EMS” or “Emergency Stop.”
Third-generation emergency stop switch with Reverse Energy Structure Smallest in its class
- Two button sizes—ø30mm and ø40mm
- Two button colors—red for emergency stop switch and yellow for stop switch
- Two ways of resetting —pulling and turning.
- UL, c-UL recognized, EN compliant.
- Safety lock mechanism (IEC 60947-5-5; 6.2)
- Direct opening action (IEC 60947-5-5; 5.2, IEC 60947-5- 1, Annex K)
- Degree of protection: IP65 (IEC60529) Specifications Applicable Standards IEC 60947-5-1, EN 60947-5-1 IEC 60947-5-5 (Note), EN 60947-5-5 (Note) JIS C8201-5-1, JIS C8201-5-5, UL508, CSA C22.2 No.14, GB14048.5 Operating Temperature –25 to +60°C (no freezing) Storage Temperature –45 to +80°C (no freezing) Operating Humidity 45 to 85% RH (no condensation) Operating Force Push to lock: 10.5N Pull to reset: 8.8N Turn to reset: 0.17 N·m Minimum Force Required for Direct Opening Action 40N Minimum Operator Stroke Required for Direct Opening Action 4.5 mm Maximum Operator Stroke 4.5 mm Contact Resistance 50 mΩ maximum (initial value) Insulation Resistance 100 MΩ minimum (500V DC megger) Overvoltage Category II Impulse Withstand Voltage 2.5 kV Pollution Degree 3 Operation Frequency 900 operations/hour Shock Resistance Operation extremes: 150 m/s Damage limits: 1000 m/s2 Vibration Resistance Operation extremes: 10 to 500 Hz amplitude 0.35 mm, acceleration 50 m/s Damage limits: 10 to 500 Hz, amplitude 0.35 mm, acceleration 50 m/s Mechanical Life 100,000 operations minimum Electrical Life 100,000 operations minimum Degree of Protection IP65 (IEC 60529) Short-circuit Protection 250V/10A fuse (Type aM IEC 60269-1/IEC 60269-2) Conditional Short-circuit Current 1000A Terminal Style Solder terminal Recommended Tightening Torque for Locking Ring
0.88 N·m
Applicable Wire Size 1.25 mm 2 maximum Terminal Soldering Condition 310 to 350°C, within 3 seconds Weight (approx.) ø30mm button: 13g ø40mm button: 16g Note: Except for stop switch (yellow button) Standards Applicable Standards Mark File No. or Organization UL508 CSA C22.2 No.14 UL/c-UL Recognition File No.E68961 EN60947-5-1 EN60947-5-5 (note) TÜV SÜD EU low voltage directive GB14048.5 CCC No. 2012010305525957 (Stop switch: CCC No. 2012010305525958)
- Stop switch (yellow button) is EN60947-5-1. Contact Ratings Rated Insulation Voltage (Ui) 250V Rated Thermal Current (Ith) 5A Rated Operating Voltage (Ue) 30V 125V 250V Rated Operating Current (Note) Main Contacts AC 50/60 Hz Resistive Load (AC-12) – 5A 3A Inductive Load (AC-15) – 1.5A 0.75A DC Resistive Load (DC-12) 2A 0.4A 0.2A Inductive Load (DC-13) 1A 0.22A 0.1A
- Minimum applicable load: 5V AC/DC, 1 mA (reference value) (May vary depending on the operating conditions and load)
- Operational current represents the classification by making and breaking currents (IEC 60947-5-1). Note: TÜV/CCC rating: AC-15 0.75A/250V, DC-13 1A/30V UL rating: Standard Duty AC 0.75A/250V Standard Duty DC 1A/30V X6 Series Emergency Stop Switches (Unibody)ø16
Pushlock Pull/Turn Reset Switch (Solder Terminal) Package quantity: 1 Shape Main Contact (NC) Part No. ø30mm Mushroom 1NC AB6E-3BV01PRH 2NC AB6E-3BV02PRH ø40mm Mushroom 1NC AB6E-4BV01PRH 2NC AB6E-4BV02PRH
- Pushlock pull/turn reset switches are locked when pressed, and reset when pulled or turned clockwise. Arrow Marked Pushlock Pull/Turn Reset Switch (Solder Terminal) Package quantity: 1 Shape Main Contact (NC) Part No. ø30mm Mushroom 1NC AB6E-3BV01PRM 2NC AB6E-3BV02PRM ø40mm Mushroom 1NC AB6E-4BV01PRM 2NC AB6E-4BV02PRM
- Pushlock pull/turn reset switches are locked when pressed, and reset when pulled or turned clockwise. X6 Series Emergency Stop Switches (Unibody) ø16
The values shown on the left are the minimum dimensions for mounting with other ø16 mm pushbuttons. For other control units of different sizes and styles, determine the values according to dimensions, operation, and wiring. X Y ø30 mm Button 40 mm min. 40mm min. ø40 mm Button 50 mm min. 50mm min. ø16.2 +0.2 X Y Dimensions ø40.0 Unmarked Arrow Marked Unmarked Arrow Marked ø30mm Button ø40mm Button ø40.0 3.6 Solder terminal (Depth behind the panel: 19.5 mm) Mounting Hole Layout 17.9 1.7 +0.2 0.59.2 Panel thickness 0.8 to 4.5 15.9 +0.2 20.6 20.6 ø15.8 ø16.2+0.2 ø30.0 ø30.0 Terminal Arrangement (Bottom View) 1NC: Terminals located near the TOP marking TOP Accessories Shape Material Part No. Package Quantity Remarks Locking Ring Wrench Metal (nickel-plated brass) MT-001 1
- Used to tighten the locking ring when installing the X6 switch onto a panel. Locking Ring Polyamide XA9Z-LNPN10 10 • Black All dimensions in mm. ø16 X6 Series Emergency Stop Switches (Unibody)
Nameplate (for ø16 Emergency Stop Switches) Package quantity: Description Legend Part No. Material Background Color Legend Color For ø30mm Button Blank HAAV-0 Polyamide Yellow Black EMERGENCY STOP HAAV-27 For ø40mm Button Blank HAAV4-0 EMERGENCY STOP HAAV4-27
- Cannot be used with switch guard. ø43.5 ø16 1.7 0.3 Projection 0.51.7 ø60 ø16 Projection Nameplate for ø30mm Button HAAV-∗
- Remove the projection from the nameplate using pliers, otherwise the switch cannot be installed.
- Panel thickness when using a nameplate: 0.5 to 3 mm Dimensions Nameplate for ø40mm Button HAAV4-∗ SEMI S2 Compliant Switch Guard Package quantity: 1 Shape Material Part No. Remarks Switch Guard Polyamide (PA6) XA9Z-KG1
- IP65 degree of protection
- Color: yellow (Munsell 2.5Y8/10 or equiva- lent)
- Cannot be used with nameplate. Gasket ø16 23.1 ø50 ø57 (1.7) (0.2)
- Panel thickness when using a nameplate: 0.5 to 3 mm Switch Guard XA9Z-KG1 Note: Switch guards have been designed for applications in semiconductor manufacturing equipment only. Do not use the switch guards with emergency stop switches which are installed on other machines such as machine tools or food processing machines. Machinery Directive of the European Commission and IEC 60204-1 require that emergency stop switches be installed in a readily accessible area, and the usage of switch guards is not permitted. X6 Series Emergency Stop Switches (Unibody) ø16 Nameplates (white) Shape Description Part No. Material Plate Color Legend For ø16mm Series For ø29mm Mushroom HAAV-0-W Polyamide White (Munsell N9.5) Blank For ø49mm Mushroom HAAV4-0-W
ø16 X6 Series Emergency Stop Switches (Unibody) Instructions Panel Mounting Remove the locking ring from the operator and check that the rubber gasket is in place. Insert the operator from panel front into the panel hole. Face the side with the projection upward, and tighten the locking ring using the locking ring wrench MT-001. Projection Rubber Gasket Locking Ring Operator Notes for Panel Mounting Using the locking ring wrench MT-001, tighten the locking ring to a torque of 0.88 N·m. Do not use pliers. Do not apply excessive force, otherwise the locking ring will become damaged. Wiring 1. Applicable wire size is 1.25 mm2 maximum. 2. Solder the terminals using a soldering iron at 310 to 350°C for 3 seconds maximum. Do not use flow or dip soldering. SnAgCu type lead-free solder is recommended. Make sure that the soldering iron touches the terminals only, not plastic parts. Do not apply external force such as bending the terminals or applying tensile force on the wires. 3. Use a non-corrosive rosin flux. To prevent the flux from entering the switch while soldering, face the terminals downward. 4. Because the terminal spacing is narrow, use protective tubes or heat shrinkable tubes to avoid burning the wire sheath or short circuit. 5. Apply force on the terminals in the vertical direction to the panel only, otherwise the terminals will be damaged. Contact Bounce When the button is reset by pulling or turning, the NC contacts will bounce. When designing a control circuit, take the contact bounce time into consideration (reference value: 20 ms). Handling Do not expose the switch to excessive shock and vibrations, otherwise the switch may be deformed or damaged, causing malfunction or operation failure.
- Turn off power to the X6 series units before installation, removal, wiring, maintenance, and inspection. Failure to turn power off may cause electrical shocks or fire hazard.
- For wiring, use wires of proper size to meet the voltage and current requirements and solder properly. Improper soldering may cause overheating and create fire hazards. Correct Incorrect Safety Precautions
Small, unibody emergency stop switches suitable for equipment with small mounting space. Requires only ø16mm × 19.5mm for installation.
- ø29mm and ø40mm mushroom operators
- Degree of protection IP65 and IP40 (IEC 60529)
- Dark red (Munsell 5R4/12) and bright red (Munsell 7.5R4.5/14) colors for operators of emergency stop switches, and yellow/gray for stop switch operators.
- Gold-plated crossbar contacts
- Push-to-lock, pull or turn-to-reset operator
- UL, c-UL recognized. EN compliant.
- Safety lock mechanism (IEC 60947-5-5, 6.2)
- Direct opening action mechanism (IEC 60947-5-5, 5.2, IEC60947-5-1, Annex K) Standards Applicable Standards Mark File No. or Organization UL508 CSA C22.2 No.14 UL/c-UL Recognition File No.E68961 EN60947-5-1 EN60947-5-5 (note) TÜV SÜD EU Low Voltage Directive GB14048.5 CCC No. 2008010305286343 Note: Except for stop switch (yellow and gray button) Contact Ratings Rated Insulation Voltage (Ui) 250V Thermal Current (Ith) 5A Rated Operating Voltage (Ue) 30V 125V 250V Rated Operating Current AC 50/60Hz Resistive Load (AC-12) — 5A 3A Inductive Load (AC-15) — 3A 1.5A DC Resistive Load (DC-12) 2A 0.4A 0.2A Inductive Load (DC-13) 1A 0.22A 0.1A
- Minimum applicable load: 5V AC/DC, 1 mA (reference value) (May vary depending on the operating conditions and load.)
- The rated operating currents are measured at resistive/inductive loads as specified in IEC 60947-5-1. Specifications Applicable Standards IEC 60947-5-1, EN 60947-5-1 IEC 60947-5-5 (Note), EN 60947-5-5 (Note) JIS C8201-5-1, UL508, CSA C22.2 No.14 GB14048.5 Operating Temperature −25 to +60°C (no freezing) Storage Temperature −45 to +80°C (no freezing) Operating Humidity 45 to 85% RH (no condensation) Operating Force Push-to-lock: 10.5N Pull to reset: 10N Turn to reset: 0.16 N·m Minimum Force Required for Direct Opening Action 40N Minimum Operator Stroke Required for Direct Opening Action 4.0 mm Maximum Operator Stroke 4.5 mm Contact Resistance 50 mΩ maximum (initial value) Insulation Resistance 100 MΩ minimum (500V DC megger) Overvoltage Category II Impulse Withstand Voltage 2.5 kV Pollution Degree 3 Operating Frequency 900 operations/hour Shock Resistance Operating extremes: 150 m/s Damage limits: 1000 m/s Vibration Resistance Operating extremes: 10 to 500 Hz, amplitude 0.35mm, acceleration 50 m/s Damage limits: 10 to 500 Hz, amplitude 0.35 mm, acceleration 50 m/s Durability Mechanical: 250,000 Electrical: 100,000 250,000 (24V AC/DC, 100mA) Degree of Protection IP65, IP40 (IEC 60529) Short-circuit Protection 250V/10A fuse (Type aM IEC 60269-1/IEC 60269-2) Conditional Short-circuit Current 1000A Terminal Style Solder terminal, Solder/tab #110 terminal Recommended Tightening Torque for Locking Ring
Applicable Wire Size 1.25 mm maximum (AWG16 maximum) Terminal Soldering Condition 310 to 350°C, within 3 seconds Weight (approx.) ø29mm mushroom: 14g ø40mm mushroom: 17g Note: Except for stop switches (operator color: yellow and gray) Solder Terminal IP65 (body color: yellow) Solder/tab #110 Solder Terminal IP40 (body color: black) XA Series Emergency Stop Switches (Unibody)ø16 XA
Pushlock Pull/Turn Reset (Solder Terminal) Shape Contact Part No. Operator Color CodeIP40 (contact part: black) IP65 (contact part: yellow) ø29mm Mushroom 1NC XA1E-BV3U01K XA1E-BV3U01 R: red RH: bright red 2NC XA1E-BV3U02K XA1E-BV3U02 ø40mm Mushroom 1NC XA1E-BV4U01K XA1E-BV4U01 2NC XA1E-BV4U02K XA1E-BV4U02
- Solder/tab #110 terminal is also available. Specify “T” before in the Ordering No. XA1E-BV3U02KR → XA1E-BV3U02KTR Dimensions 20.6 ø40 Solder Terminal (Behind the panel: 19.5) ø29 mm Mushroom ø40 mm Mushroom Solder/Tab Terminal #110 (Behind the panel: 23.9) +0. ø16. +0.2 1.7 +0.2 17.9 ø29. 20.6 ø15.8 Panel Thickness 0.8 to 4.5 Mounting Hole 10.2 0.5 0.510.2 15.93.615.98.0 Terminal Arrangement (Bottom View) TOP 1NC: Termimals on top Mounting Hole Layout ø16.2 +0.2 X Y X Y ø29mm Mushroom 40 mm minimum ø40mm Mushroom 50 mm minimum
- The values shown on the left are the minimum dimensions for mounting with other ø16 mm pushbuttons. For other control units of different sizes and styles, determine the values according to the dimensions, operation, and wiring. All dimensions in mm. ø16 XA Series Emergency Stop Switches (Unibody)
The World’s First ø16 mm, 4-contact Emergency Stop Switch. Compact size - only 27.9 mm deep behind the panel. Reliable “Safe break action.”
- The depth behind the panel is only 27.9 mm for 1 to 4 con tacts, both on illuminated and non-illuminated.
- IDEC’s original “Safe break action” ensures that the contacts open when the contact block is detached from the operator.
- 1 to 4NC main contacts and 1NO monitor contact
- Push-to-lock, Pull or Turn-to-reset operator
- Direct opening action mechanism (IEC 60947-5-5, 5.2, IEC60947-5-1, Annex K)
- Safety lock mechanism (IEC 60947-5-5, 6.2)
- Degree of protection IP65 (IEC 60529)
- Two operator sizes: ø29 and ø40 mm
- Dark red (Munsell 5R4/12) or bright red (Munsell 7.5R4.5/14) colors are available for the operator of non- illuminated emer gency stop switches, and gray for stop switch operators.
- UL, c-UL recognized. EN compliant Standards Applicable Standards Mark File No. or Organization UL508 CSA C22.2 No. 14 UL/c-UL Recognized, File No. E68961 IEC60947-5-5 (Note) UL991 (Note) NFPA79 (Note) — UL File No. E305148 EN60947-5-1 EN60947-5-5 (Note) TÜV SÜD EU Low Voltage Directive GB14048.5 CCC No. 2005010305150899 (Stop switch: CCC No. 2005010305150894) Note: Except for stop switches (button color: gray). Contact Ratings NC main contacts (black) /NO monitor contact (blue) Rated Insulation Voltage (Ui) 300V (illuminated part: 60V) Rated Thermal Current (Ith) 5A Rated Operating Voltage (Ue) 30V 125V 250V Rated Operating Current Main Contacts AC Hz Resistive Load (AC-12) – 3A 3A Inductive Load DC Resistive Load (DC-12) 2A 0.4A 0.2A Inductive Load (DC-13) 1A 0.22A 0.1A Monitor Contacts AC Hz Resistive Load Inductive Load DC Resistive Load (DC-12) 2A 0.4A 0.2A Inductive Load (DC-13) 1A 0.22A 0.1A
- Minimum applicable load: 5V AC/DC, 1 mA (reference value) (Operating area may vary according to the operating conditions and load types.)
- The rated operating currents are measured at resistive/inductive load types specified in IEC 60947-5-1. Illumination Ratings Rated Voltage Operating Voltage Rated Current 24V AC/DC 24V AC/DC ±10% 11 mA Specifications Applicable Standards IEC60947-5-1, EN60947-5-1 IEC60947-5-5 (Note), EN60947-5-5 (Note), JIS C8201-5-1, UL991 (Note), NFPA79 (Note), UL508, CSA C22.2 No.14, GB14048.5 Operating Temperature –25 to +60°C (no freezing) Illuminated: –25 to +55°C (no freezing) Storage Temperature –45 to +80°C Operating Humidity 45 to 85% RH (no condensation) Operating Force Push to lock: 10.5N Pull to reset: 10N Turn to reset: 0.16 N·m Minimum Force Required for Direct Opening Action 60N Minimum Operator Stroke Required for Direct Opening Action 4.0 mm Maximum Operator Stroke 4.5 mm Contact Resistance 50 mΩ maximum (initial value) Insulation Resistance 100 MΩ minimum (500V DC megger) Overvoltage Category II Impulse Withstand Voltage 2.5 kV Pollution Degree 3 (inside LED unit: 2) Operation Frequency 900 operations/hour Shock Resistance Operating extremes: 150 m/s Damage limits: 1000 m/s2 Vibration Resistance Operating extremes: 10 to 500 Hz, amplitude 0.35 mm acceleration 50 m/s2 Damage limits: 10 to 500 Hz, amplitude 0.35 mm acceleration 50 m/s2 Mechanical Life 250,000 operations minimum Electrical Life 100,000 operations min 250,000 operations min (24V AC/DC, 100 mA) Degree of Protection IP65 (IEC60529) Short-circuit Protection 250V/10A fuse (Type aM, IEC60269-1/IEC60269-2) Conditional Short-circuit Current 1000A Terminal Style Solder terminal, PC board terminal Recommended Tightening Torque for Locking Ring
Connectable Wire 1.25 mm 2 maximum (AWG16 maximum) Soldering Conditions 310 to 350°C, 3 seconds maximum Weight ø29 mm: 23g, ø40 mm: 28g Note: Except for stop switches (operator color: gray). Direct Opening Action XA Series Emergency Stop Switches (w/Removable Contact Block)ø16 XA
Pushlock Pull/Turn Reset (Solder Terminal/PC Board Terminal) Shape NC Main Contact NO Monitor Contact Part No. Operator Color CodeSolder Terminal PC Board Terminal ø29mm Mushroom 1NC — XA1E-BV301➀ XA1E-BV301V➀ R: Dark red RH: Bright red 2NC — XA1E-BV302➀ XA1E-BV302V➀ 3NC — XA1E-BV303➀ XA1E-BV303V➀ 4NC — XA1E-BV304➀ XA1E-BV304V➀ 1NC 1NO XA1E-BV311➀ XA1E-BV311V➀ 2NC 1NO XA1E-BV312➀ XA1E-BV312V➀ 3NC 1NO XA1E-BV313➀ XA1E-BV313V➀ ø40mm Mushroom 1NC — XA1E-BV401➀ XA1E-BV401V➀ 2NC — XA1E-BV402➀ XA1E-BV402V➀ 3NC — XA1E-BV403➀ XA1E-BV403V➀ 4NC — XA1E-BV404➀ XA1E-BV404V➀ 1NC 1NO XA1E-BV411➀ XA1E-BV411V➀ 2NC 1NO XA1E-BV412➀ XA1E-BV412V➀ 3NC 1NO XA1E-BV413➀ XA1E-BV413V➀
- Specify a color code in place of ➀ in the Part No.
- Terminal cover (XA9Z-VL2) is ordered separately.
- For EMO Switches, see page 58. Illuminated Pushlock Pull/Turn Reset (Solder Terminal/PC Board Terminal) Shape NC Main Contact NO Monitor Contact Part No. Operator ColorSolder Terminal PC Board Terminal ø29mm Mushroom 1NC — XA1E-LV301Q4R XA1E-LV301Q4VR Dark red only 2NC — XA1E-LV302Q4R XA1E-LV302Q4VR 3NC — XA1E-LV303Q4R XA1E-LV303Q4VR 4NC — XA1E-LV304Q4R XA1E-LV304Q4VR 1NC 1NO XA1E-LV311Q4R XA1E-LV311Q4VR 2NC 1NO XA1E-LV312Q4R XA1E-LV312Q4VR 3NC 1NO XA1E-LV313Q4R XA1E-LV313Q4VR ø40mm Mushroom 1NC — XA1E-LV401Q4R XA1E-LV401Q4VR 2NC — XA1E-LV402Q4R XA1E-LV402Q4VR 3NC — XA1E-LV403Q4R XA1E-LV403Q4VR 4NC — XA1E-LV404Q4R XA1E-LV404Q4VR 1NC 1NO XA1E-LV411Q4R XA1E-LV411Q4VR 2NC 1NO XA1E-LV412Q4R XA1E-LV412Q4VR 3NC 1NO XA1E-LV413Q4R XA1E-LV413Q4VR
- Terminal cover (XA9Z-VL2) is ordered separately. ø16 XA Series Emergency Stop Switches (w/Removable Contact Block)
ø29mm Mushroom ø40mm Mushroom PC Board Terminal 3.1 Locking Ring Rubber Gasket Mounting Panel Thickness: 0.8 to 3.7 XA9Z-VL2 Terminal Cover 19.8 8.7 2.1 27.2 25.8 20.6 30.429.4 30.4 ø29.8 25.8 20.630.4 ø40 ø29 Illuminated ø29mm Mushroom Solder Terminal 27.2 19.8 8.7 4.5 Mounting Panel Thickness: 0.8 to 3.7 2.1 25.8 20.6 30.4 PC Board Terminal 3.129.4 30.4 ø29.8 Locking Ring Rubber Gasket XA9Z-VL2 Terminal Cover 25.8 20.630.4 ø40mm Mushroom ø40 ø29 PC Board Layout (Bottom View) Panel Cut-out Non-Illuminated Illuminated +0.2ø16.2 +0.2 1.7 +0.2 17.9 8.7 19.8 8.7 19.8 10-ø1.2 holes 6.5 11.2 4.5 3-ø1.7 holes All dimensions in mm.3-ø1.7 holes 8.7 19.8 8.7 19.8 10-ø1.2 holes 6.5 11.2 Mounting Hole Layout LED Unit Internal Circuit X Y ø29mm Mushroom 40 mm minimum ø40mm Mushroom 50 mm minimum
- The values shown above are the minimum dimensions for mounting with other ø16 mm pushbuttons. For other control units of different sizes and styles, determine the values according to the dimensions, opera tion, and wiring convenience. ø16.2 +0.2 X Y X1 R1 R2 LED LED chip Protection diode Resistor XA Series Emergency Stop Switches (w/Removable Contact Block) ø16 XA
Terminal Arrangement (Bottom View) Nameplates (for ø16 Emergency Stop Switches) Description Legend Part No. Material Plate Color Legend Color For ø29mm Operator (blank) HAAV-0 Polyamide Yellow BlackEMERGENCY STOP HAAV-27 For ø40mm Operator (blank) HAAV4-0 EMERGENCY STOP HAAV4-27 Accessories and Replacement Parts Description & Shape Material Part No. Ordering No. Package Quantity Remarks Metal (nickel-plated brass) MT-001 MT-001 1
- Used to tighten the locking ring when installing the XA emer gency stop switch onto a panel. Polyamide XA9Z-LN XA9Z-LNPN10 10 • Black PBT XA9Z-VL2 XA9Z-VL2PN02 2
- White
- Used for solder terminals.
- Also applicable to the XW series. For Solder Terminal XA9Z-LED2R XA9Z-LED2R
- Replacement LED unit for illumi nated (for XA series only).For PC Board Terminal XA9Z-LED2VR XA9Z-LED2VR Stainless Steel MT-101 MT-101 • Used for removing the LED unit. TOP LeftR ight TOP LeftR ight With NO monitor contacts (blue) NC main contacts (black): Terminals 1-2 NO monitor contacts (blue): Terminals 3-4 NC main contacts (black) only NC main contacts (black): Terminals 1-2 1NC: Terminals on right 2NC: Terminals on right and left 3NC: Terminals on right, left, and top 1NC: Terminals on top 2NC: Terminals on right and left Non-illuminated Illuminated LeftR ight TOP X1 X2 TOP LeftR ight X1 X2 LEDLED With NO monitor contacts (blue) NC main contacts (black): Terminals 1-2 NO monitor contacts (blue): Terminals 3-4 NC main contacts only (black) NC main contacts(black): Terminals 1-2 1NC: Terminals on right 2NC: Terminals on right and left 3NC: Terminals on right, left, and top 1NC: Terminals on top 2NC: Terminals on right and left For ø29mm Operator For ø40mm Operator ø43.5 ø16 1.70 .3 0.51.7 ø60 ø16
- Panel thickness when using the nameplate: 0.5 to 2 mm
- Panel thickness when using the nameplate: 0.5 to 2 mm All dimensions in mm. Ring Wrench Locking Ring Terminal Cover LED Unit LED Unit Removal Tool ø16 XA Series Emergency Stop Switches (w/Removable Contact Block)
Removing the Contact Block First unlock the operator button. While pushing up the white bayonet ring, using a small screwdriver (width: 2.5 to 3 mm) if necessary, turn the contact block counterclockwise and pull out. Do not exert excessive force when using a screwdriver, otherwise the bayonet ring may be dam aged. Bayonet Ring ➀ Push ➁ Turn counterclockwise Notes for Removing the Contact Block 1. When the contact block is removed, the monitor contact (NO contact) is closed. 2. While removing the contact block, do not exert excessive force, otherwise the switch may be damaged. Panel Mounting Remove the locking ring from the operator and check that the rubber gasket is in place. Insert the operator from panel front into the panel hole. Face the side with the anti- rotation protrusion on the operator upward, and tighten the locking ring. Operator Unit Locking Ring Anti-rotation Protrusion Rubber Gasket Notes for Panel Mounting To mount the XA emergency stop switches onto a panel, tighten the locking ring to a tightening torque of 0.88 N·m maximum using ring wrench MT-001. Do not use pliers. Do not exert excessive force, otherwise the locking ring may be damaged. Installing the Contact Block First turn the bayonet ring to the unlocked position. Bayonet Ring Unlocked Locked Align the small ▲ marking on the edge of the operator base with the TOP marking on the contact block. Press the con tact block onto the operator and turn the contact block clock wise until the bayonet ring clicks. TOP marking ▲ marking TOP marking (contact block) ➀ Press ➁ Turn Notes for Installing the Contact Block Check that the contact block is securely installed on the opera tor. When the emergency stop switch is properly assembled, the bayonet ring is in place as shown below. Removing the LED Unit (Contact Block) Pull out the LED unit while squeezing the latches on the LED unit using the LED unit removal tool (MT-101). TOP side Latches Squeeze the LED unit on the latches and pull out. Contact BlockUnibody XA Series Emergency Stop Switches (w/Removable Contact Block) ø16 Safety Precautions
- Turn off power to the XA series emergency stop switch before starting installation, removal, wiring, maintenance, and inspection of the relays. Failure to turn power off may cause electrical shock or fire hazard.
- Use the LED unit removal tool when replacing the LED unit to avoid burn on your hands.
- Use wires of the proper size to meet the voltage and cur rent requirements, and solder the wires correctly. If solder ing is incomplete, the wire may heat during opera- tion, causing fire hazard. XA
Installing the LED Unit (with Removable Contact Block) Align the to of the LED unit with the TOP marking on the contact block. Push the LED unit into the contact block. Wiring 1. The applicable wire size is 1.25 mm2 maximum. 2. Solder the terminal at a temperature of 310 to 350°C within 3 seconds using a soldering iron. Sn-Ag-Cu type is recommended when using lead-free solder. When solder- ing, do not touch the enabling switch with the soldering iron. Also ensure that no tensile force is applied to the ter- minal. Do not bend the terminal or apply excessive force to the terminal. 3. Use a non-corrosive rosin flux. 4. Because the terminal spacing is narrow, use protective tubes or heat shrinkable tubes to avoid burning of wire coating or short circuit. Solder/Tab Terminal #110 1. Use #110 receptacles for 0.5mm-thick tabs. 2. Because the terminal spacing is narrow, use protective tubes or heat shrinkable tubes of 0.5mm minimum in thickness. 3. Do not apply force on the terminals in the direction other than vertical to the mounting panel, otherwise the terminals will be damaged. PC Board Terminal 1. When mounting a contact block on a PC board, provide sufficient rotating space for the PC board when installing and removing the contact block. 2. When mounting an XA emergency stop switch on a PC board, make sure that the operator is securely installed. About PC Board and Circuit Design 1. Use PC boards made of glass epoxy copper-clad lami nated sheets of 1.6 mm in thickness, with double-sided through hole. 2. PC boards and circuits must withstand rated voltage and current, including the instantaneous current and voltage at switching. 3. The minimum applicable load is 5V AC/DC, 1 mA. This value may vary according to the operating environment and load. 4. Within the 2.8∗ mm areas shown in the figure below, ter minals touch the PC board, resulting in possible short cir cuit on the printed circuit. When designing a PC board pattern, take this possibility into consideration. Installing Insulation Terminal Cover To install the terminal cover (XA9Z-VL2), align the TOP marking on the terminal cover with TOP marking on the con tact block, and press the terminal cover toward the contact block. Note: For wiring, insert the wires into the holes in the terminal cover before soldering. Contact Bounce When the button is reset by pulling or turning, the NC main contacts will bounce. When pressing the button, the NO monitor contacts will bounce. When designing a control circuit, take the contact bounce time into consideration (reference value: 20 ms). Nameplate When anti-rotation is not required, remove the projection from the nameplate using pliers. Projection Nameplate Handling Do not expose the switch to excessive shock and vibration, otherwise the switch may be deformed or damaged, causing malfunction or operation failure. TOP side 19.8 8.7 19.8 2.8∗ 2.8∗ (0.5) 10-ø1.2 holes Solder Surface Surface for installing components 2.8∗ 2.8∗ Solder Surface Surface for installing components 8.7 All dimensions in mm. ø16 XA Series Emergency Stop Switches (w/Removable Contact Block)
ø22 mm, 4-contact Emergency Stop Switch. Compact size—only 37.1 mm deep behind the panel (screw terminal style 48.7 mm with terminal cover). Reliable “Safe break action.”
- The depth behind the panel is only 37.1 mm for 1 to 4 contacts (screw terminal style 48.7 mm with terminal cover).
- The same depth behind the panel for illuminated and non-illuminated switches.
- IDEC’s original “Safe break action” ensures that the contacts open when the contact block is detached from the operator.
- 1 to 4NC main contacts and 1 or 2NO monitor contact
- Push-to-lock, Pull or Turn-to-reset operator
- Direct opening action mechanism (IEC60947-5-5, 5.2, IEC60947-5-1, Annex K)
- Safety lock mechanism (IEC60947-5-5, 6.2)
- Degree of protection IP65 (IEC60529)
- Screw terminal style is finger-safe (IP20).
- Two operator sizes: ø40 and ø60 mm
- Dark red (Munsell 5R4/12) or bright red (Munsell 7.5R4.5/14) colors are available for the non-illuminated operator.
- Push-ON illumination available (operator size: ø60)
- Connector style available to reduce wiring time and wiring mistakes.
- UL c-UL listed. EN compliant Direct Opening Action Standards Applicable Standards Mark File No. or Organization UL508 CSA C22.2 No.14 UL/c-UL Recognition File No. E68961 (solder terminal, PC board terminal) UL/c-UL Listing File No. E68961 (screw terminal) UL508 UL Recognition File No. E68961 (connector style) IEC60947-5-5 (Note) UL991 NFPA79 — UL File No. E305148 (solder terminal, PC board terminal) UL Listing File No. E305148 (screw terminal) EN60947-5-1 EN60947-5-5 (Note) TÜV SÜD EU low voltage directive GB14048.5 CCC No. 2005010305150897 (except connector style) Note: Except for stop switch (yellow button) Contact Ratings (NC main contacts/NO monitor contact) Rated Insulation Voltage (Ui) Screw Terminal 250V Solder Terminal 300VPC Board Terminal Connector 125V Rated Thermal Current (Ith) 5A (connector style: 2.5A) Rated Operating Voltage (Ue) 30V 125V 250V (Note 3) Rated Operating Current Main Contacts AC Hz Resistive Load (AC-12) – 5A (Note 1) 3A Inductive Load (AC-15) – 3A (Note 2) 1.5A DC Resistive Load (DC-12) 2A 0.4A 0.2A Inductive Load (DC-13) 1A 0.22A 0.1A Monitor Contacts AC Hz Resistive Load (AC-12) – 1.2A 0.6A Inductive Load (AC-14) – 0.6A 0.3A DC Resistive Load (DC-12) 2A 0.4A 0.2A Inductive Load (DC-13) 1A 0.22A 0.1A
- Minimum applicable load: 5V AC/DC, 1 mA (reference value) (Operating area depends on the operating conditions and load types.)
- The rated operating currents are measured at resistive/inductive load types specified in JIS C8201-5-1. Note 1: Solder terminal/PC board terminal: 3A, Connector: 2.5A Note 2: Solder terminal/PC board terminal: 1.5A Note 3: Except for connector style. Illumination Ratings Rated Voltage Operating Voltage Rated Current 24V AC/DC 24V AC/DC ±10% 15 mA Note: An LED lamp is built into the contact block and cannot be replaced. Specifications Applicable Standards IEC60947-5-1, EN60947-5-1 IEC60947-5-5 (Note), EN60947-5-5 JIS C8201-5-1, UL508, UL991, NFPA79, CSA C22.2 No. 14, GB14048.5 Operating Temperature Non-illuminated: –25 to +60°C (no freezing) LED illuminated: –25 to +55°C (no freezing) Storage Temperature –45 to +80°C Operating Humidity 45 to 85% RH (no condensation) Operating Force Push to lock: 32N Pull to reset: 21N Turn to reset: 0.27 N·m Minimum Force Required for Direct Opening Action 80N Minimum Operator Stroke Required for Direct Opening Action 4.0 mm Maximum Operator Stroke 4.5 mm Contact Resistance 50 mΩ maximum (initial value) Connector style: 30 mΩ (Note) Insulation Resistance 100 MΩ minimum (500V DC megger) Overvoltage Category II Impulse Withstand Voltage 2.5 kV Pollution Degree 3 (connector style: 2) Operation Frequency 900 operations/hour Shock Resistance Operating extremes: 150 m/s Damage limits: 1000 m/s2 Vibration Resistance Operating extremes: 10 to 500 Hz, amplitude 0.35 mm, acceleration 50 m/s2 Damage limits: 10 to 500 Hz, amplitude 0.35 mm, acceleration 50 m/s2 Mechanical Life 250,000 operations minimum Electrical Life 100,000 operations minimum 250,000 operations minimum (24V AC/DC, 100 mA) Degree of Protection Panel front: IP65 (IEC 60529) Terminal Protection: IP20 (screw terminal, when using XW9Z-VL2MF) Short-circuit Protection 250V/10A fuse (Type aM, IEC60269-1/IEC60269-2) Conditional Short-circuit Current 1000A Terminal Style Solder terminal, PC board terminal, M3 screw terminal, Connector Recommended Tightening Torque for Locking Ring
2.0 N·m
Screw terminal: 0.75 to 1.25 mm 2 (AWG18 to 16) Solder terminal / PC board terminal: 1.25 mm2 maximum (AWG16 maximum) Connector style: 0.3 to 0.85 mm2 (AWG22 to 18) Soldering Conditions 310 to 350°C, 3 seconds maximum Recommended Tightening Torque for Terminal Screw 0.6 to 1.0 N·m Weight ø40 mm: 72g ø60 mm: 81g Note: When connecting the applicable connector to a 1m wire of 0.33 mm2 (AWG22). XW Series Emergency Stop Switchesø22 XW
Non-illuminated Pushlock Pull / Turn Reset (Screw Terminal) Shape NC Main Contact NO Monitor Contact Part No. ➀Operator Color CodeIP20 w/Terminal Cover ø40mm Mushroom 1NC — XW1E-BV401MF➀ XW1E-BV401M➀ R: Dark red RH: Bright red 2NC — XW1E-BV402MF➀ XW1E-BV402M➀ 3NC — XW1E-BV403MF➀ XW1E-BV403M➀ 4NC — XW1E-BV404MF➀ XW1E-BV404M➀ 1NC 1NO XW1E-BV411MF➀ XW1E-BV411M➀ 2NC 1NO XW1E-BV412MF➀ XW1E-BV412M➀ 3NC 1NO XW1E-BV413MF➀ XW1E-BV413M➀ 2NC 2NO XW1E-BV422MF➀ XW1E-BV422M➀ ø60mm Mushroom 1NC — XW1E-BV501MF➀ XW1E-BV501M➀ 2NC — XW1E-BV502MF➀ XW1E-BV502M➀ 3NC — XW1E-BV503MF➀ XW1E-BV503M➀ 4NC — XW1E-BV504MF➀ XW1E-BV504M➀ 1NC 1NO XW1E-BV511MF➀ XW1E-BV511M➀ 2NC 1NO XW1E-BV512MF➀ XW1E-BV512M➀ 3NC 1NO XW1E-BV513MF➀ XW1E-BV513M➀ 2NC 2NO XW1E-BV522MF➀ XW1E-BV522M➀
- Specify a color code in place of ➀ in the Part No.
- IP20 types can be connected to solid wires only.
- For EMO Switches, see page 58. Non-illuminated Pushlock Pull/Turn Reset (Solder Terminal/PC Board Terminal) Shape NC Main Contact NO Monitor Contact Part No. ➀Operator Color CodeSolder Terminal PC Board Terminal ø40mm Mushroom 1NC — XW1E-BV401➀ XW1E-BV401V➀ R: Dark red RH: Bright red 2NC — XW1E-BV402 ➀ XW1E-BV402V➀ 3NC — XW1E-BV403➀ XW1E-BV403V➀ 4NC — XW1E-BV404➀ XW1E-BV404V➀ 1NC 1NO XW1E-BV411➀ XW1E-BV411V➀ 2NC 1NO XW1E-BV412➀ XW1E-BV412V➀ 3NC 1NO XW1E-BV413➀ XW1E-BV413V➀ 2NC 2NO XW1E-BV422➀ —
- Specify a color code in place of ➀ in the Part No.
- Terminal cover (XA9Z-VL2) is ordered separately. Pushlock Pull/Turn Reset (Connector) Shape NC Main Contact NO Monitor Contact Part No. ➀Operator Color Code ø40mm Mushroom 3NC — XW1E-BV403V➀-BC R: Dark red RH: Bright red
- Specify a color code in place of ➀ in the Part No.
- Applying for UL/c-UL listing. The switch unit (XW1E-BV) is UL/c-UL listed.
- See page 30 for applicable connectors. ø22 XW Series Emergency Stop Switches
LED Illuminated Pushlock Pull/Turn Reset (Screw Terminal) Shape Illumination Rated Voltage NC Main Contact NO Monitor Contact Part No. IP20 w/Terminal Cover ø40mm Mushroom LED 24V AC/DC 1NC — XW1E-LV401Q4MFR XW1E-LV401Q4MR 2NC — XW1E-LV402Q4MFR XW1E-LV402Q4MR 3NC — XW1E-LV403Q4MFR XW1E-LV403Q4MR 4NC — XW1E-LV404Q4MFR XW1E-LV404Q4MR 1NC 1NO XW1E-LV411Q4MFR XW1E-LV411Q4MR 2NC 1NO XW1E-LV412Q4MFR XW1E-LV412Q4MR 3NC 1NO XW1E-LV413Q4MFR XW1E-LV413Q4MR 2NC 2NO XW1E-LV422Q4MFR XW1E-LV422Q4MR
- The operator color is red only.
- IP20 types can be connected to solid wires only. LED Illuminated Pushlock Pull/Turn Reset (Solder Terminal/PC Board Terminal) Shape Illumination Rated Voltage NC Main Contact NO Monitor Contact Part No. Solder Terminal PC Board Terminal ø40mm Mushroom LED 24V AC/DC 1NC — XW1E-LV401Q4R XW1E-LV401Q4VR 2NC — XW1E-LV402Q4R XW1E-LV402Q4VR 3NC — XW1E-LV403Q4R XW1E-LV403Q4VR 4NC — XW1E-LV404Q4R XW1E-LV404Q4VR 1NC 1NO XW1E-LV411Q4R XW1E-LV411Q4VR 2NC 1NO XW1E-LV412Q4R XW1E-LV412Q4VR 3NC 1NO XW1E-LV413Q4R XW1E-LV413Q4VR 2NC 2NO XW1E-LV422Q4R —
- The operator color is red only.
- Terminal cover (XA9Z-VL2) is ordered separately. Push-ON LED Illuminated Pushlock Pull/Turn Reset (Screw Terminal) Shape Illumination Rated Voltage NC Main Contact NO Monitor Contact Part No. IP20 w/Terminal Cover ø40mm Mushroom LED 24V AC/DC 3NC — XW1E-TV403Q4MFR XW1E-TV403Q4MR 2NC 1NO XW1E-TV412Q4MFR XW1E-TV412Q4MR
- The operator color is red only.
- Push-ON is illuminated when the operator is latched, and turns off when reset.
- IP20 types can be connected to solid wires only. Push-ON LED Illuminated Pushlock Pull/Turn Reset (Connector) Shape Illumination Rated Voltage NC Main Contact NO Monitor Contact Part No. ø40mm Mushroom LED 24V AC/DC 3NC — XW1E-TV403Q4VR-BC
- The operator color is red only.
- Push-ON is illuminated when the operator is latched, and turns off when reset. See page 30 for applicable connectors. XW Series Emergency Stop Switches ø22 XW
Dimensions (Non-Illuminated) Screw Terminal (w/terminal cover) Gasket Panel Thickness 0.8 to 6 IP20 Protection Cover XW9Z-VL2MF Locking Ring M3 Terminal Screw 0.5 48.7 18.5 20.1 Panel Cut-out +0.2 3.2 +0.4 24.1 R0.8 max +0.4 ø22.3 ø40 ø60 R Screw Terminal (IP20) Solder Terminal and PC Board Terminal ø40mm Operator ø40mm Operator ø60mm Operator All dimensions in mm. ø40mm Operator ø60mm Operator ø22.3 ø60 ø40 18.5 20.1 Panel Cut-out +0.2 3.2 +0.4 24.1 R0.8 max. +0.4 Panel Thickness 0.8 to 6 Gasket Terminal Cover XW9Z-VL2M M3 Terminal Screw Locking Ring 0.5 48.7 47.2 R 17.4 20.1 24.1 +0.4 R0.8 max. 3.2 +0.2 0ø22.3 +0.4 ø40 Panel Cut-out 19.8 8.7 19.8 8.7 6.5 11.2 PC Board Layout (Bottom View) 3-ø1.7 holes 8-ø1.2 holes 8.7 19.8 33.6 3.1 PC Board Terminal 19.8 8.733.6 2.1 0.5 39.6 Locking Ring Gasket Panel Thickness 0.8 to 6 XA9Z-VL2 Terminal Cover Solder Terminal R ø22 XW Series Emergency Stop Switches
Dimensions (Illuminated) Screw Terminal (IP20) LED Illuminated Screw Terminal (w/terminal cover) PC Board Terminal 19.8 20.117.4 PC Board Layout (Bottom View) 3-ø1.7 holes 11.2 6.5 8.7 19.8 8.7 19.8 10-ø1.2 holes 5.7 8.7 19.8 33.6 3.1 Solder Terminal Terminal Cover XA9Z-VL2 8.7 2.1 5.7 Panel Thickness 0.8 to 6 0.5 39.6 Gasket Locking Ring Panel Cut-out +0.2 3.2 +0.424.1 +0.4 ø22.3 R0.8 max. ø40 R ø40mm Operator Solder Terminal and PC Board Terminal LED Illuminated ø40mm Operator Panel Cut-out +0.2 3.2 +0.4 24.1 +0.4 ø22.3 R0.8 max. ø40 48.7 Panel Thickness 0.8 to 6 Gasket IP20 Protection Cover XW9Z-VL2MF Locking Ring M3 Terminal Screw 0.5 XW9Z-VL2M M3 Terminal Screw Panel Thickness 0.8 to 6 Gasket Terminal Cover Locking Ring 0.5 47.2 48.7 18.5 20.1 LED Push-ON 18.5 20.1 R R LED Illuminated ø40mm Operator Dimensions (Connector Style) Non-illuminated / LED Push-ON 53.0 33.6 Panel Thickness 0.8 to 6.0 55.5 32 17.420.1 Applicable Connector Connector 15.3 10.7 31.4 36.1 (when unlocked) ø40 R Panel Cut-out +0.2 3.2 +0.2 24.1 +0.4 ø22. R0.8 max ø40mm Operator All dimensions in mm. For applicable connectors, see page 30. XW Series Emergency Stop Switches ø22 XW
Mounting Hole Layout LED Internal Circuit Terminal Arrangement (Bottom View) ø22.3 +0.4 X Y R LED LED chip Protection Diode Resistor X Y Screw Terminal 70 mm minimum Solder/PC Board Terminal 50 mm minimum Connector Style 50 mm minimum 70 mm minimum
- The values shown above are the minimum dimensions for mounting with other ø22mm pushbuttons. For other control units of different sizes and styles, determine the values accord ing to the dimensions, operation, and wiring convenience.All dimensions in mm. TOP Left Right TOP Left Right TOP Left Right *1 *2 *1 *2 *2 *1 *1 *2 *4 *3 *3 *4 *4 *3 *1 *2 *2 *1 *1 *2 *2 *1 *2 *1 TOP LED Left Right TOP LED Left Right TOP LED Left Right *1 *2 *4 *3 *1 *2 *2 *1 *3 *4 *4 *3 *1 *2 *2 *1 *1 *2 *1 *2 *2 *1 *2 *1 LED TOP X1 X2 Left Right ∗1 ∗2 ∗1 ∗2 ∗2 ∗1 LED TOP X1 X2 Left Right ∗3 ∗4 ∗1 ∗2 ∗2 ∗1
- Contact
- Contact Number (1-4) TOP (Example: 1NO-3NC contact) Left Right 11 12 34 33 21 22 42 411-2: NC main contact 3-4: NO monitor contact Starting with the contact of TOP side, in a counterclockwise direction. NC main contacts only NC main contacts Terminals 1-2 With 1NO monitor contacts NC main contacts: Terminals 1-2 NO monitor contacts: Terminals 3-4 With 2NO monitor contacts NC main contacts: Terminals 1-2 NO monitor contacts: Terminals 3-4 1NC: Terminals on right 2NC: Terminals on right and left 3NC: Terminals on right, left, and top 1NC: Terminals on top 2NC: Terminals on right and left NC main contacts only NC main contacts: Terminals 1-2 With 1NO monitor contacts NC main contacts Terminals 1-2 NO monitor contacts: Terminals 3-4 With 2NO monitor contacts NC main contacts: Terminals 1-2 NO monitor contacts: Terminals 3-4 1NC: Terminals on right 2NC: Terminals on right and left 3NC: Terminals on right, left, and top 1NC: Terminals on top 2NC: Terminals on right and left NC main contacts only NC main contacts: Terminals 1-2 With 1NO monitor contacts NC main contacts: Terminals 1-2 NO monitor contacts: Terminals 3-4 Screw Terminal Non-illuminated Screw Terminal Illuminated Screw Terminal Illuminated Push-ON Terminal Marking Development
- On solder terminal and PC board terminal, the contact block is marked with contact codes (NC main contact 1-2: black, NO monitor contact 3-4: blue). Connector 11 1 22 2 A B B A A B B A Connector 222 111 A B B A A B B ALED Connector Style Non-illuminated Connector Style Push-ON 1212 TOP Left Right TOP Left Right TOP Left Right Solder Terminal / PC Board Terminal Non-illuminated Solder Terminal / PC Board Terminal Illuminated NC main contacts only NC main contacts: Terminals 1-2 With 1NO monitor contacts NC main contacts: Terminals 1-2 NO monitor contacts: Terminals 3-4 With 2NO monitor contacts NC main contacts: Terminals 1-2 NO monitor contacts: Terminals 3-4 1NC: Terminals on right 2NC: Terminals on right and left 3NC: Terminals on right, left, and top 1NC: Terminals on top 2NC: Terminals on right and left Solder Terminal only NC main contacts only NC main contacts: Terminals 1-2 With 1NO monitor contacts NC main contacts: Terminals 1-2 NO monitor contacts: Terminals 3-4 With 2NO monitor contacts NC main contacts: Terminals 1-2 NO monitor contacts: Terminals 3-4 1NC: Terminals on right 2NC: Terminals on right and left 3NC: Terminals on right, left, and top 1NC: Terminals on top 2NC: Terminals on right and left Solder Terminal only RightLeft TOP X1 X2 LED RightLeft TOP X1 X2 LED RightLeft LED X2X1 TOP ø22 XW Series Emergency Stop Switches
Description & Shape Material Part No. Ordering No. Package Quantity Remarks Ring Wrench Metal (nickel-plated brass) (weight: approx. 150g) MW9Z-T1 MW9Z-T1 1
- Used to tighten the locking ring when installing the XW emergency stop switch onto a panel. ø28110 Anti-rotation Ring Ring: Polyamide Gasket: Nitryl rubber HW9Z-RL HW9Z-RLPN10 10
- The anti-rotation ring is used for preventing the operator from turning. Terminal Cover PBT XA9Z-VL2 XA9Z-VL2PN02 2
- White
- Used for solder terminals. Terminal Cover PPE XW9Z-VL2M XW9Z-VL2MPN02 2
- Black
- Used for screw terminals.
- Attached to IP20 protection cover units. IP20 Protection Cover Polyamide XW9Z-VL2MF XW9Z-VL2MFPN02 2
- Black
- Used on terminals for IP20 finger protection.
- Only solid wires can be used.
- The IP20 protection cover cannot be removed once installed. Ring Adapter Rubber on metal base XW9Z-A30E XW9Z-A30EPN02 2
- Yellow panel surface
- Used for installing XW1E emergency stop switches in ø30mm mounting hole.
- Can be used for XW1E emergency stop switch- es only.
- IP65 protection.
- Cannot be used with nameplates. Panel thick- ness when mounted: 0.8 to 3.0 mm
- Panel Mounting Notes:
- XW emergency stop switches of screw terminal are provided with a terminal cover.
- All dimensions in mm. TOP ø22 ø29 1.5 Adapter Gasket Adaper Washer ∗ (∗: A or B) Note 1: Adapter washer thickness (t) A = 1.2 mm B = 0.8 mm Operator XW1E Gasket Adapter Washer A Adapter Washer B Locking Ring Adapter GasketPanel Note 2: The recess is for preventing rotation and is not necessary for this product. Panel Cut-out ø21.8ø38 0.5 1.5 ø22.3 t (Note 1) 3 (Note 2) +0.5 +0.5 +0.2 4.8R0.8 max. ø30.5 (color: yellow) Adapter Gasket Adaper Washer ∗ (∗: A or B) Note 1: Adapter washer thickness (t) A = 1.2 mm B = 0.8 mm Operator XW1E Gasket Adapter Washer A Adapter Washer B Locking Ring Adapter GasketPanel Note 2: The recess is for preventing rotation and is not necessary for this product. Panel Cut-out ø21.8ø38 0.5 1.5 ø22.3 t (Note 1) 3 (Note 2) +0.5 +0.5 +0.2 4.8R0.8 max. ø30.5 (color: yellow) XW Series Emergency Stop Switches ø22 XW
Nameplate (for ø22 Emergency Stop Switches) Description Legend Part No. Ordering No. Package Quantity Material Plate Color Legend Color For ø40mm Operator (blank) HWAV-0-Y HWAV-0-Y Polyamide Yellow Black EMERGENCY STOP HWAV-27-Y HWAV-27-Y For ø60mm Operator (blank) HWAV5-0 HWAV5-0 PBTEMERGENCY STOP HWAV5-27 HWAV5-27 EMERGENCY STOP HWAV5F-27 HWAV5F-27PN10 10 PET film sticker
- EMERGENCY OFF and white nameplates (blank) also available. See page 61 and 64 for details. Maintenance Parts Description & Shape Material Part No. Ordering No. Package Quantity Remarks Locking Ring Polyamide HW9Z-LN HW9Z-LNPN05 5 • Black Washer Nitryl rubber HW9Z-WM HW9Z-WMPN10 10 • Black For ø40mm Operator For ø60mm Operator ø60 ø22 0.91.5 EMERGENCY STOP 2.3 0.6 ø22 ø80 ø80 2.7
- Panel thickness when using the nameplate: 0.8 to 4.5 mm Sticker Nameplate for ø60mm Operator
- Panel thickness when using the nameplate: 0.8 to 4 mm ø22 XW Series Emergency Stop Switches
- Turn off power to the XW series emergency stop switch before starting installation, removal, wiring, maintenance, and inspection of the relays. Failure to turn power off may cause electrical shock or fire hazard.
- Use wires of the proper size to meet the voltage and cur rent requirements, and solder the wires correctly. If solder ing is incomplete, the wire may heat during opera- tion, causing fire hazard. Instructions Removing the Contact Block First unlock the operator button. Grab the bayonet ring ➀ and pull back the bayonet ring until the latch pin clicks ➁, then turn the contact block counterclockwise and pull out Bayonet Ring ➀ Grab ➁ Pull ➀ Grab ➂ Turn counterclockwise Notes for removing the contact block 1. When the contact block is removed, the monitor contact (NO contact) is closed. 2. While removing the contact block, do not exert excessive force, otherwise the switch may be damaged. 3. An LED lamp is built into the contact block for illuminated pushbuttons. When removing the contact block, pull the contact block straight to prevent damage to the LED lamp. If excessive force is exerted, the LED lamp may be dam aged and fail to light. Panel Mounting Remove the locking ring from the operator and check that the rubber gasket is in place. Insert the operator from panel front into the panel hole. Face the side without thread on the operator with TOP marking upward, and tighten the locking ring using ring wrench MW9Z-T1 to a torque of 2.0 N·m maximum. Locking Ring Rubber Gasket Operator without TOP marking thread Notes for Panel Mounting To prevent the XW emergency stop switch from rotating when resetting from the latched position, use of an anti- rota tion ring (HW9Z-RL) or a nameplate is recommended. Installing the Contact Block First unlock the operator button. Align the small ▼ marking on the edge of the operator with the small ▲ marking on the yellow bayonet ring. Hold the contact block, not the bayonet ring. Press the contact block onto the operator and turn the contact block clockwise until the bayonet ring clicks. ➁ Turn clockwise ▼ marking ▲ marking ➀ Push Notes for installing the contact block Make sure that the bayonet ring is in the locked position. Check that the two projections on the bayonet ring are securely in place. Projections Latched Unlatched Wiring Solder Terminal 1. The applicable wire size is 1.25 mm2 maximum. 2. Solder the terminal at a temperature of 310 to 350°C within 3 seconds using a soldering iron. Sn-Ag-Cu type is recommended when using lead-free solder. When solder- ing, do not touch the enabling switch with the soldering iron. Also ensure that no tensile force is applied to the ter minal. Do not bend the terminal or apply excessive force to the terminal. 3. Use a non-corrosive rosin flux. 4. Because the terminal spacing is narrow, use protective tubes or heat shrinkable tubes to avoid burning of wire coating or short circuit. PC Board Terminal 1. When mounting a contact block on a PC board, provide sufficient rotating space for the PC board when installing and removing the contact block. 2. When mounting an XW emergency stop switch on a PC board, make sure that the operator is securely installed. 3. Do not solder by flow soldering. Otherwise, damage may be caused. XW Series Emergency Stop Switches ø22 XW
About PC Board and Circuit Design 1. Use PC boards made of glass epoxy copper-clad lami- nated sheets of 1.6 mm in thickness, with double-sided through hole. 2. PC boards and circuits must withstand rated voltage and current, including the instantaneous current and voltage at switching. 3. The minimum applicable load is 5V AC/DC, 1 mA. This value may vary according to the operating environment and load. 4. Within the 2.8∗ mm areas shown in the figure below, ter minals touch the PC board, resulting in possible short cir cuit on the printed circuit. When designing a PC board pattern, take this possibility into consideration. 19.8 8.7 19.8 8.7 (0.5) (0.5)(0.5) 5.7 1.6 (PC Board) (0.5)(0.5) 2.8∗ 2.8∗ 2.8∗ (0.5) 2.8∗ 2.8∗ 10-ø1.2 holes Solder SurfaceSolder Surface Surface for installing components Surface for installing components Screw Terminal Applicable Crimping Terminals Solid Wire Wire Insulating Tube Crimping Terminal 4.7 to 5.9 6.0 max. 3.2 min. 4.7 to 5.93.0 max. ø3.2 min. Wire Insulating Tube Crimping Terminal 4.7 to 5.9 ø6.0 max. 4.7 min. 6.2 max. ø1.2 max. Ring Terminal Spade Terminal 1. Wire thickness: 0.75 to 1.25 mm2 (AWG18 to 16)
- Be sure to install an insulating tube on the crimping terminal. 2. Tighten the M3 terminal screw to a tightening torque of 0.6 to 1.0 N·m. Connector 1. Connector shape
- Tyco Electronics, D-2000 series Part No. 1376009-1 (tab header, board mount) 2. Applicable connectors (to be supplied by user)
- Tyco Electronics, D-2000 series Part No. 1-1318119-4 (receptacle housing)
- Tyco Electronics, D-2000 series Part No. 1318107-1 (receptacle contact) 3. To prepare correct receptacles for the connector, read the instruction sheet and catalog of Tyco Electronics and understand the installation and wiring method. 4. Fasten the cable so that the connector is not pulled. Otherwise the switch may be deformed and damaged, causing malfunction or operation failure. Installing & Removing Terminal Covers XA9Z-VL2 To install the terminal cover, align the TOP marking on the terminal cover with TOP marking on the contact block, and press the terminal cover toward the contact block. Note: For wiring, insert the wires into the holes in the terminal cover before soldering. XW9Z-VL2M To install the terminal cover, align the TOP marking on the terminal cover with the TOP marking on the contact block. Place the two projections on the bottom side of the contact block into the slots in the terminal cover. Press the terminal cover toward the contact block. TOP Marking ➀ Place the projections on the contact bock. ➁ Press the terminal cover To remove the terminal cover, pull out the two latches on the top side of the terminal cover. Do not exert excessive force to the latches, otherwise the latches may break. TOP Markings Pull out the latches. IP20 Protection Terminal Cover XW9Z-VL2MF To install the IP20 protection cover, align the TOP marking on the cover with the TOP marking on the contact block, and press the cover toward the contact block. TOP Marking TOP Marking (Press) Notes: 1. Once installed, the XW9Z-VL2MF cannot be removed. 2. The XW9Z-VL2MF cannot be installed after wiring. 3. With the XW9Z-VL2MF installed, crimping terminals cannot be used. Use solid wires. 4. Make sure that the XW9Z-VL2MF is securely installed. IP20 cannot be achieved when installed loosely, and electric shocks may occur. ø22 XW Series Emergency Stop Switches Only solid wires can be used for IP20 units.
When the button is reset by pulling or turning, the NC main contacts will bounce. When pressing the button, the NO monitor contacts will bounce. When designing a control circuit, take the contact bounce time into consideration (reference value: 20 ms). LED Illuminated Switches An LED lamp is built into the contact block and cannot be replaced. Installing the Anti-rotation Ring HW9Z-RL Align the side without thread on the operator with TOP mark ing, the small ▲ marking on the anti-rotation ring, and the recess on the mounting panel. TOP Marking ▲ marking on the anti-rotation ringWithout thread Anti-rotation Ring (HW9Z-RL) Installing the Nameplate Align the side without thread on the operator with TOP mark ing, the projection on the nameplate, and the recess on the mounting panel. Nameplate or Switch Guard When anti-rotation is not required, remove the projection from the nameplate or switch guard using pliers. Switch Guard Projections Nameplate Handling Do not expose the switch to excessive shocks and vibra- tions, otherwise the switch may be deformed or damaged, causing malfunction or operation failure. XW Series Emergency Stop Switches ø22 XW
–25 to +60°C (no freezing) Illuminated units: –25 to +55°C Storage Temperature –40 to +80°C (no freezing) Operating Humidity 45 to 85% RH (no condensation) Operating Force 50N Minimum Force Required for Direct Opening Action 5.5 mm Maximum Operator Stroke 10 mm Contact Resistance 50 mΩ maximum (initial value) Insulation Resistance 100 MΩ minimum (500V DC megger) Dielectric Strength Between live and dead metal parts: Contacts: 2,500V AC, 1 minute Illuminated parts: 1,000V AC, 1 minute Vibration Resistance Damage limits: 30 Hz, amplitude 1.5 mm Operating extremes: 5 to 55 Hz, amplitude 0.5 mm Shock Resistance Damage limits: 1,000 m/s Operating extremes: 100 m/s2 Operating Frequency 900 operations/h Life Mechanical: 250,000 operations minimum Electrical: 100,000 operations minimum (at 900 operations/h, duty ratio 40%) Degree of Protection IP65 Terminal Style M3.5 screw Weight 49g (HW1E-BV402R) 56g (HW1E-LV402Q4R) Contact Ratings Rated Insulation Voltage (Ui) 250V Rated Thermal Current (Ith) 10A Rated Operational Voltage (Ue) 24V 110V 220V Rated Operational Current AC Hz Resistive Load (AC-12) 6A 3A 3A Inductive Load (AC-15) 6A 3A 3A DC Resistive Load (DC-12) 6A 2A 1A Inductive Load (DC-13) 1 .5A 0.3A 0.15A
- Minimum applicable load (reference value): 3V AC/DC, 5 mA (Applicable range may vary with operating conditions and load types.)
- The operational current represents the classification by making and breaking currents (IEC 60947 -5-1). LED Lamp Ratings Rated Operating Voltage of Unit LED Lamp Part No. Rated Voltage Rated Current 6V AC/DC LSTD-6R 6V AC/DC ±10% 7 mA 12V AC/DC LSTD-1R 12V AC/DC ±10% 10 mA 24V AC/DC LSTD-2R 24V AC/DC ±10% 10 mA LED Internal Circuit Internal Circuit LED Chip Resistor Zener Diode Protection Diode HW Series Emergency Stop Switchesø22 Pushlock Turn Reset Switches (Unibody) Shape Contact Part No. Button Color ø40mm Mushroom Pushlock Turn Reset HW1E-BV4 1NO-1NC HW1E-BV411R Red only 2NC HW1E-BV402R
- When pressed, the button is held depressed. The button is released by turning clockwise. Illuminated Pushlock Turn Reset Switches (Unibody) Shape Contact Part No. Button Color ø40mm Mushroom Pushlock Turn Reset HW1E-LV4 1NO-1NC HW1E-LV411Q0R Red only 2NC HW1E-LV402Q0R
- When pressed, the button is held depressed. The button is released by turning clockwise.
- The illuminated pushlock turn reset switch does not contain a lamp. Order LED lamps separately. For lamps, see page 38. Standards Applicable Standards Mark File No. or Organization UL508 CSA C22.2 No. 14 UL/c-UL Listing File No. E55996 EN60947 -5-5 TÜV SÜD EU Low Voltage Directive GB14048.5 CCC No.2004010305132908 Emergency Stop Switches (Unibody) Specifications
R0.8 max. +0.4 +0.4 +0.2 ø22.3 3.2 24.1 Determine the minimum mounting hole centers in consideration of convenience for wiring. HW1E-BV4 Terminal Arrangement (Bottom View) HW1E-LV4 All dimensions in mm. HW Series Emergency Stop Switches ø22 Dimensions HW1E-BV4 HW1E-LV4 ø40 0.5 Panel Thickness 0.8 to 6 Gasket 11.5 M3.5 Terminal Screw Locking Ring Gasket ø40 23.5 Panel Thickness 0.8 to 6 0.5 Locking Ring Lamp Terminal M3.5 Terminal Screw M3.5 Terminal Screw 1NO-1NC TOP 22 (NC) 13 (NO) 14 (NO)21 (NC) 2NC TOP 22 (NC) 11 (NC) 12 (NC)21 (NC) 1NO-1NC 2NC LAMP TOP 22 (NC) 13 (NO) 14 (NO)21 (NC) LAMP TOP 22 (NC) 11 (NC) 12 (NC)21 (NC) HW
Rated Insulation Voltage 600V Rated Thermal Current 10A Contact Ratings by Utilization Category IEC 60947 -5-1 AC-15 (A600) DC-13 Characteristics Contact Ratings by Utilization Category Operational Voltage 24V 48V 50V 110V 220V 440V Operational Current AC Hz AC-12 Control of resistive loads and solid state loads 10A — 10A 10A 6A 2A AC-15 Control of electromagnetic loads (> 72 VA) 10A — 7A 5A 3A 1A DC DC-12 Control of resistive loads and solid state loads 8A 4A — 2.2A 1 .1A — DC-13 Control of electromagnets 4A 2A — 1 .1A 0.6A — Emergency Stop Switches (w/Removable Contact Block) Specifications Specifications Operating Temperature –25 to +60°C (no freezing) Storage Temperature –40 to +80°C Operating Humidity 45 to 85% RH (no condensation) Operating Force 50N Minimum Force Required for Direct Opening Action 5.5 mm Maximum Operator Stroke 10 mm Contact Resistance 50 mΩ maximum (initial value) Insulation Resistance 100 MΩ minimum (500V DC megger) Dielectric Strength Between live and dead metal parts Between terminals of different poles Between terminals of the same pole 2,500V AC, 1 minute Vibration Resistance Damage limits: 30 Hz, amplitude 1 .5 mm Operating extremes: 5 to 55 Hz, amplitude 0.5 mm Shock Resistance Damage limits: 1000 m/s Operating extremes: 100 m/s2 Operating Frequency 900 operations/h Life Mechanical: 500,000 operations minimum (push-pull: 250,000 operations) Electrical: 500,000 operations minimum (push-pull: 250,000 operations) (at 900 operations/h, duty ratio 40%) Degree of Protection IP65 (IEC 60529) Terminal Style M3.5 screw Weight 76g (HW1B-V322) 99g (HW1B-X422R) 54g (HW1B-Y202) 79g (HW1B-V422R-EMO) Pushlock Turn Reset Switches (with Removable Contact Block) Shape Contact Part No. Button Color ø29mm Mushroom Pushlock Turn Reset HW1B-V3 1NC HW1B-V301➀ Specify a button color code in place of ➀ in the Part No. R: red Y: yellow 1NO-1NC HW1B-V311➀ 2NC HW1B-V302➀ 2NO-2NC HW1B-V322➀ ø40mm Mushroom Pushlock Turn Reset HW1B-V4 1NC HW1B-V401➀ 1NO-1NC HW1B-V411➀ 2NC HW1B-V402➀ 2NO-2NC HW1B-V422➀ ø60mm Mushroom Pushlock Turn Reset HW1B-V5 1NC HW1B-V501➀ 1NO-1NC HW1B-V5➅1➀ 2NC HW1B-V502➀ 2NO-2NC HW1B-V522➀
- Y ellow buttons cannot be used as emergency stop switches in compliance with EN standards.
- When pressed, the button is held depressed. The button is released by turning clockwise.
- Pushlock turn reset switches with one or three contact blocks contain a dummy block.
- Safety lever lock HW9Z-LS is supplied with the switch.
- Other contact arrangements and gold-plated silver contacts are also available. See page 35. ø22 HW Series Emergency Stop Switches Standards Applicable Standards Mark File No. or Organization UL508 UL Listing File No. E68961 CSA C22.2 No. 14 File No. LR92374 EN60947 -5-5 TÜV Rheinland EU Low Voltage Directive GB14048.5 CCC No.2005103050145656
Pushlock Key Reset Switches (with Removable Contact Block) Shape Contact Part No. Button Color ø40mm Mushroom Pushlock Key Reset HW1B-X4 1NC HW1B-X401R Red only 1NO-1NC HW1B-X411R 2NC HW1B-X402R 2NO-2NC HW1B-X422R
- When pressed, the button is held depressed. The button is released by turning the key clockwise.
- Pushlock key reset switches with one or three contact blocks contain a dummy block.
- Two identical keys and safety lever lock HW9Z-LS are supplied with the switch.
- Safety lever lock HW9Z-LS is supplied with the switch.
- Other contact arrangements and gold-plated silver contacts are also available. See Part No. Development. Push-Pull Switches (with Removable Contact Block) Shape Contact Part No. Button Color ø40mm Mushroom Push-Pull (2-position) HW1B-Y2 1NC HW1B-Y201➀ Specify a button color code in place of ➀ in the Part No. R: red Y: yellow 1NO-1NC HW1B-Y211➀ 2NC HW1B-Y202➀
- The button is maintained at either pulled or depressed position.
- Push-pull switches are available with one or two contact blocks.
- Push-pull switches with one contact block contain a dummy block.
- Safety lever lock HW9Z-LS is supplied with the switch. Accessory Nameplate (for ø22 Emergency Stop Switches) Shape Name Part No. Legend Package Quantity Remarks EMERGENCY STOP ø60 ø22 0.91.5 Nameplate for Emergency Stop Switch (See page 36 for panel cut- out.) HWAV-0-Y (blank) Background: Y ellow Legend: Black Applicable panel thickness: 0.8 to 4.5 mm Material: Polyamide Not applicable for ø60 mm mushroom buttons. Legend "EMERGENCY STOP" is indicated outside a ø44mm circle. HWAV-27-Y EMERGENCY STOP
- EMERGENCY OFF and white nameplates (blank) also available. See page 61 and 64 for details. Emergency Stop Switches (w/Removable Contact Block) For emergency stop purposes, these switches must contain at least one NC contact block. HW1B-V4 11 R -MAU Optional contact MAU: Gold-plated silver contact Button/lens color code Contact arrangement code 01: 1NC 11: 1NO-1NC 02: 2NC 21: 2NO-1NC 12: 1NO-2NC 03: 3NC 31: 3NO-1NC 22: 2NO-2NC 13: 1NO-3NC 04: 4NC Note: Push-pull HW1B-Y2 can have a maximum of two contact blocks. Part No. Development HW Series Emergency Stop Switches ø22 HW
ø29mm Pushlock Turn Reset HW1B-V3 LOCK ø29 29.4 41.4 26.5 Terminal Screw M3.5 Panel Thickness 0.8 to 6 Locking Ring Safety Lever Lock Gasket 49.4 (1 or 2 blocks) 69.4 (4 blocks) 1 contact block 2 contact blocks 4 contact blocks ø40mm Pushlock Turn Reset HW1B-V4 LOCK 29.4 41.4 ø40 Safety Lever Lock 26.5 ø60mm Pushlock Turn Reset HW1B-V5 34.5 ø60 Safety Lever Lock ø40mm Pushlock Key Reset HW1B-X4 LOCK 29.4 41.4 ø40 49.4 Safety Lever Lock 26.5 ø40mm Push-Pull HW1B-Y2 LOCK 29.4 41.4 ø40 Safety Lever Lock 26.5 R0.8 max. +0.4 +0.4 +0.2 ø22.3 3.2 24.1 The minimum mounting centers shown below are applicable to emergency stop switches with one layer of contact blocks (two contact blocks). When two layers of contact blocks are mounted, determine the minimum mounting centers in consideration of convenience for wiring. Minimum Mounting Centers for Emergency Stop Switches Unit Vertical Spacing Horizontal Spacing HW1B-V3 HW1B-V4 HW1B-X4 HW1B-Y2 50 mm minimum 50 mm minimum HW1B-V5 60 mm minimum 60 mm minimum Note: When using the safety lever lock, determine the vertical spacing in consideration of convenience for installing and removing the safety lever lock. Recommended vertical spacing: 100 mm Panel Cut-Out All dimensions in mm. All dimensions in mm. ø22 HW Series Emergency Stop Switches
Shape Material Part No. Ordering No. Package Quantity Description & Dimensions (mm) Locking Ring Wrench Metal (weight: approx. 150g) MW9Z-T1 MW9Z-T1 1
- Used to tighten the locking ring when installing the HW switch onto a panel.
- Tighten the locking ring to a torque of 2.0 N·m. Lamp Holder Tool Rubber OR-55 OR-55 1
- Used to install and remove the LED lamps. Rubber Mounting Hole Plug Rubber (black) OB-31 OB-31PN05 5
- Used to plug the unused ø22.2mm mounting holes. Metallic Mounting Hole Plug Diecast Metal (locking ring: plastic) LW9Z-BM LW9Z-BM 1
- Used to plug the unused ø22.2mm mounting holes.
- Tighten the locking ring to a torque of 1 .2 N·m.
- IP66
- Mounting panel thickness: 0.8 to 6 mm Barrier Plastic HW-VG1 HW-VG1PN10 10 20 1.5
- Used to prevent con- tact between adjacent lead wires when units are mounted closely. Barriers should always be used in close mounting. Ring Adapter Rubber HW9Z-A25 HW9Z-A25PN05 5
- Used to install the HW/TW units into ø25 mounting holes.
- IP65
- Cannot be used with anti-rotation ring and nameplate.
- Mounting panel thickness: 1 .2 to 6.0 mm Ring Adapter Adapter: Plastic Washer: Metal HW9Z-A30 HW9Z-A30PN02 2
- Used to install the HW units into ø30 mounting holes (except for HW1E and HW1B-M5/V5).
- IP65
- Cannot be used with anti-rotation ring, name- plate, full-shroud illuminated pushbuttons, pushbutton selectors, and mono-lever switches.
- Mounting panel thickness: 1 .6 to 4.0 mm Ring Adapter Adapter: Rubber Washer: Metal HW9Z-A30E HW9Z-A30EPN02 2
- Used to install the HW1E units into ø30 mount- ing holes.
- IP65
- Cannot be used with anti-rotation ring and nameplate.
- Mounting panel thickness: 1 .6 to 3.8 mm 110 ø28 ø11.6 ø14 ø25 ø29 3.5 3.5 Gasket Locking Ring ø25.8 12 3 HW Series Emergency Stop Switches ø22 HW
Shape Material Part No. Ordering No. Package Quantity Description & Dimensions (mm) Safety Lever Lock Plastic HW9Z-LS HW9Z-LSPN10 10 • Y ellow
- 1 piece included as standard Locking Ring Polyamide HW9Z-LN HW9Z-LNPN05 5 • Black Gasket Nitryl rubber HW9Z-WM HW9Z-WMPN10 10 Spare Key Metal Brass, nickel- plated HW9Z-SK-231 HW9Z-SK-231PN02 2 • For pushlock key reset switches LED Lamps (LSTD) Shape Rated Operating Volt age Current Draw Part No. Ordering No. Package Quantity Base Dimensions (mm)AC DC 6V AC/DC 17 mA (A, R, W, Y) 8 mA (G, PW, S) 14 mA (A, R, W, Y) 5.5 mA (G, PW, S) LSTD-6R LSTD-6R 1 BA9S/13 (20.8) 18.42.4 Grommet (x1) Base (x2) BA9S/13 Voltage LSTD-6RPN10 10 12V AC/DC 11 mA 10 mA LSTD-1R LSTD-1R 1 LSTD-1RPN10 10 24V AC/DC 11 mA 10 mA LSTD-2R LSTD-2R 1 LSTD-2RPN10 10 Incandescent Lamps (LS) Shape Rated Operating Volt age Lamp Ratings Part No. Package Quantity Dimensions (mm) 6V AC/DC 1W (6.3V) LS-6 Base BA9S/13 ±1.522.5 ±1ø11 12V AC/DC 1W (18V) LS-8 18V AC/DC 1W (24V) LS-2 24V AC/DC 1W (30V) LS-3 ø22 HW Series Emergency Stop Switches
- Turn off the power to the HW series control units before starting installation, removal, wiring, maintenance, and inspection of the products. Failure to turn power off may cause electrical shocks or fire hazard.
- To avoid a burn on your hand, use the lamp holder tool when replacing lamps.
- For wiring, use wires of a proper size to meet the volt- age and current requirements. Tighten the M3.5 terminal screws to a tightening torque of 1 .0 to 1 .3 N·m. Failure to tighten terminal screws may cause overheat and fire. Instructions Panel Mounting Remove the contact block from the operator (for transformer pilot lights, remove the transformer from the illumination unit). Remove the locking ring from the operator. Insert the operator into the panel cut-out from the front, tighten the locking ring from the back, then install the contact block to the operator. Removing and Installing the Contact Block 1 . To remove the operator from the contact block, turn the locking lever in the direction of the arrow shown below. Then the operator can be pulled out. 2. To reinstall, place the TOP markings on the operator and the contact block mounting adapter in the same direction, and insert the operator into the contact block mounting adapter. Then turn the locking lever in the opposite direc- tion. Notes for Panel Mounting When mounting the operator onto a panel, use the optional locking ring wrench (MW9Z-T1) to tighten the locking ring. Tightening torque must not exceed 2.0 N·m. Do not use pliers. Excessive tightening will damage the locking ring. Safety Lever Lock IDEC strongly recommends using the safety lever lock (HW9Z-LS, yellow) to prevent heavy vibration or mainte- nance personnel from unlocking contacts. 1 . HW series can be mounted vertically with a minimum spacing of 50 mm (70 mm for mono-lever switches) but spacing should be determined to ensure easy operation. 2. Mount the control unit onto the panel, lock the lever, and strongly push in the safety lever lock to install. 3. When the spacing is narrower than the recommended value, with the lever unlocked, mount the safety lever lock and insert the contact unit to the operator. Then, lock the lever and strongly push in the safety lever lock to install. 4. To remove the safety lever lock, insert a flat screwdriver into the safety lever lock and push upwards. HW Series Emergency Stop Switches ø22 RemoveScrewdriver Safety Lever Lock Operator PanelContact Block Mounting Adapter Lock Lever InstallLOCK Safety Lever Lock 26.5 HW
YW Series Emergency Stop Switchesø22 Emergency Stop Switches Specifications Standards Applicable Standards Mark File No. or Organization UL508 CSA C22.2 No.14 UL/c-UL Listed File No.E68961 EN60947 -5-5 TÜV SÜD EU Low Voltage Directive GB14048.5 CCC No. 2006010305196875 R0.8 max. +0.4 +0.4 +0.2 ø22.3 3.2 24.1 50 minimum 50 minimum The 3.2-mm-wide key recess is necessary when the anti-rotation ring is used. Mounting Hole Layout LED Lamp Ratings Part No. Rated Voltage Rated Current LSED-6R 6V AC/DC 10 mA LSED-1R 12V AC/DC 14 mA LSED-2R 24V AC/DC 14 mA LSED-HR 110/120V AC/DC 5.5 mA LSED-M3R 230/240V AC/DC 2.7 mA Incandescent Lamp Ratings Part No. Rated Voltage Ratings LS-T6 6V AC/DC 6.3V 1W LS-T8 12V AC/DC 18V 1W LS-T3 24V AC/DC 30V 1W Contact Ratings (Contact Block) Rated Insulation Voltage 600V Rated Thermal Current 10A Operating Voltage 24V 120V 240V 380V AC Hz Resistive Load (AC-12) 10A 10A 6A 2A Inductive Load (AC-15) 10A 6A 3A 1 .9A DC Resistive Load (DC-12) 8A 2.2A 1 .1A – Inductive Load (DC-13) 4A 1 .1A 0.55A – Specifications Operating temperature –20 to +55°C (no freezing) Operating humidity 45 to 85% RH (no condensation) Storage temperature –45 to +80°C (no freezing) Storage humidity 95% RH maximum Degree of Protection From panel front: IP65 (IEC 60529) Terminal: IP20 (IEC 60529) Insulation Resistance 100 MΩ Dielectric Strength Contact block: 2,500V, 1 minute Pilot light: 2,000V, 1 minute Vibration Resistance Operating extremes / Damage limits: 10 to 500 Hz, amplitude 0.35 mm, acceleration 50 m/s Shock Resistance Operating extremes: 150 m/s2 (15G) Damage limits: 1,000 m/s2 (100G) Mechanical Life (minimum operations) 250,000 (single contact block) Electrical Life (minimum operations) 100,000 (single contact block)
Style Contact Part No. Button Color Code ø40mm Mushroom 1NC YW1B-V4E01R Red only 2NC YW1B-V4E02R 3NC YW1B-V4E03R 1NO-1NC YW1B-V4E11R 1NO-2NC YW1B-V4E12R 2NO-1NC YW1B-V4E21R Dimensions LED/Incandescent Illuminated Pushlock Pull/Turn Reset Style Lamp Contacts Part No. ➂ Operating Voltage Code Lens Color Code ø40mm Mushroom Without Lamp 1NC YW1L-V4E01Q0R 0 (without lamp) 250V AC/DC max. Red only 2NC YW1L-V4E02Q0R 1NO-1NC YW1L-V4E11Q0R LED 1NC YW1L-V4E01Q➂R 2 (6V AC/DC) 3 (12V AC/DC) 4 (24V AC/DC) H (110/120V AC/DC) M3 (230/240V AC/DC) 2NC YW1L-V4E02Q 1NO-1NC YW1L-V4E11Q➂R Incandescent 1NC YW1L-V4E01Q➂R 5 (6V AC/DC) 6 (12V AC/DC) 7 (24V AC/DC) 2NC YW1L-V4E02Q 1NO-1NC YW1L-V4E11Q➂R Note: Specify an operating voltage code in place of ➂ in the Part No. Dimensions 28.6 ø40 M3.5 Terminal Screw Contact Block 101010 Panel Thickness 0.8 to 6 32.545.8 Locking Ring Gasket 41.4 Note: When pressed, the button is locked in the depressed position, and is reset when either pulled or turned clockwise. All dimensions in mm. 28.6 101010 ø40 M3.5 Terminal Screw M3.5 Terminal Screw Full-Voltage Adapter Contact Block Locking Ring Panel Thickness 0.8 to 6 45.8 32.5 Gasket 41.4 Note: When pressed, the button is locked in the depressed position, and is reset when either pulled or turned clockwise. YW Series Emergency Stop Switches ø22 YW
Name & Shape Part No. Description & Dimensions (mm) Package Quantity Locking Ring Wrench MW9Z-T1 Metallic tool used to tighten the plastic locking ring when installing the YW series control unit on a panel. Lamp Holder Tool OR-55 Made of rubber. Used for replacing lamps. Rubber Mounting Hole Plug OB-31PN05 Used for plugging unused mounting holes in the panel. Color: Black 5 Metallic Mounting Hole Plug LW9Z-BM Used for plugging unused mounting holes in the panel. Weight: Approx. 18g 1 Anti-Rotation Ring HW9Z- RLPN10 Prevents rotation of switches in panel. Mainly used with selector switches when no nameplate is used. With waterproof gasket (IP65). Made of plastic (black). Applicable panel thickness: 1 .2 to 4.5 mm Padlock Cover HW9Z-KL1 1 ø28 110 ø11.6 ø14 ø29 ø25 3.5 3.5 Locking Ring ø25.8 12 3 TOP ø22 ø29 1.5 PadLock Hole ø8 Waterproof Gasket Thickness 0.5 ø50 29.5 R66.5 Panel Thickness 0.8-3.2 82.5 ø22.2 Plastic hinged cover to protect pushbuttons, illuminated pushbuttons, or selector switches. Degree of protection: IP65. Applicable panel thickness: 0.8 to 3.2 mm ø22 YW Series Emergency Stop Switches
Name & Shape Part No. Description & Dimensions (mm) Package Quantity LED Lamp LSED-6R 6V AC/DC ø10.6 20.8 Base BA9S/14 LSED-1R 12V AC/DC LSED-2R 24V AC/DC LSED-HR 110/120V AC/DC LSED-M3R 230/240V AC/DC Incandescent Lamp LS-T6P 6.3V, 1W One pack contains 100 incandescent lamps. Base BA9S/13 ±123 ±1ø11 100LS-T8P 18V, 1W LS-T3P 30V, 1W Single Contact Block YW-E10P Color: blue Contact: 1NO YW-E01P Color: reddish purple Contact: 1NC Nameplate (for ø22 Emergency Stop Switches) Description Legend Material Part No. Ordering No. Package Quantity Dimensions (mm) HWAV Blank Plastic (yellow) 1 .5 mm thick HWAV-0-Y HWAV-0-Y 1 EMERGENCY STOP ø60 ø22 0.91.6
- Legend “Emergency Stop” is indicated outside a ø44mm circle. EMERGENCY STOP HWAV-27-Y HWAV-27-Y 1 M3.5 Terminal Screw 22.3 41.4 YW Series Emergency Stop Switches ø22 YW
Din Rail Mount Transformer Safety Precautions
- Turn off the power to the YW series control units before starting in stallation, removal, wiring, maintenance, and inspection of the products. Failure to turn power off may cause electrical shocks or fire hazard.
- To avoid burning your hand, use the lamp holder tool when replac ing lamps.
- For wiring, use wires of a proper size to meet the volt- age and current requirements. Tighten the M3.5 terminal screws to a tightening torque of 1 .0 to 1 .3 N·m. Failure to tighten the terminal screws may cause overheating and fire. Secondary Terminal Screws M3.5 2-ø3.5 Mounting Holes Primary Terminal Screws M3.5 Dimensions (mm) Primary Voltage (50/60 Hz) Part No. Applicable Lamp Rating 110V AC TWR516 One full voltage illuminated unit containing LED lamp LSED-6 (6V AC/DC) or incandescent lamp LS- T6 (6.3V) 115V AC TWR5116 120V AC TWR5126 220V AC TWR526 230V AC TWR5236 240V AC TWR5246 380V AC TWR5386 440V AC TWR546 480V AC TWR5486 Note: Finger-safe terminal cover is supplied with the transformer. ø22 YW Series Emergency Stop Switches
- Remove the contact block from the operator. Remove the locking ring from the operator. Insert the operator into the panel cut-out from the front, tighten the locking ring from the back, then install the contact block to the operator. j j Pull up the locking lever. k Turn the lever to the left. l Pull out the contact block. k l Removing and Installing the Contact Block 1 . To remove the operator from the contact block, pull up the locking lever and turn it to the left. Then the operator can be pulled out. 2. To reinstall, place the TOP marking on the operator and the idec marking on the contact block mounting adapter in the same direc tion, and insert the operator into the contact block mounting adapt er. Then turn the locking lever to the right. Notes for Panel Mounting Use the optional locking ring wrench (MW9Z-T1) to mount the op- erator onto a panel. Tightening torque must not exceed 2.0 N·m. Do not use pliers. Excessive tightening will damage the locking ring. Removing Contact Blocks and Full Volt age Adapter Insert a flat screwdriver between the latch and contact block mount- ing adapter, and disengage the latch. Make sure to remove the lamp and contact blocks before removing the full voltage adapter. Lamp j ÇÇ É Full Voltage Adapter Contact Block YW Series Emergency Stop Switches ø22 YW
Tightening Torque for Terminal Screws Tighten terminal screws to a torque between 1 .0 and 1 .3 N·m. Anti-rotation Ring and Mounting Panel Turn the TOP marking on the operator and the mark on the anti- rotation ring to the recess on the mounting panel. Projections (▲ mark) Anti-rotation Ring Locking Ring Panel Thickness 1.2 to 4.5 mm Mounting Panel Thickness The mounting panel must be 0.8 to 6.0 mm in thickness. When optional accessories are added, the applicable panel thickness changes as shown below. Panel Thickness 0.8 to 6 mm Nameplate Panel Thickness 0.8 to 3.2 mm Contact Bounce When the button is reset by pulling or turning, the NC main contacts will bounce. When pressing the button, the NO monitor contacts will bounce. When designing a control circuit, take the contact bounce time into consideration (reference value: 20 ms). Nameplate When anti-rotation is not required, remove the projection from the nameplate using pli ers. Handling Do not expose the switch to excessive shock and vibration, otherwise the switch may be deformed or damaged, causing malfunction or operation failure. LED Illumination LED lamps consist of semiconductors. If the applied voltage exceeds the rated voltage, LED elements deteriorate due to overheat, resulting in significant decrease in luminance, hue change, or failure of lighting. Also, if extraneous noise, transient volt age, or transient current is applied to the circuit, similar effects will be caused. When using LED lamps, observe the following instructions. Rated Voltage The LED illuminated units are rated at 6V, 12V, 24V, 110V, or 230/240V AC/DC, and can be used within ±10% the rated voltage of either AC or DC, except the 230/240V AC/DC can be used on 250V AC/DC maximum. DC Power 1 . Switching power supply Regulated voltage from switching power supply is best suited. Make sure to use within the rated voltage of the LED lamp. 2. Rechargeable battery Note that the battery voltage may exceed the rated voltage of the LED lamp while the battery is being charged and immediately after the charging is complete. Be sure to use the LED lamp on a voltage of ±10% the rated voltage, except the 230/240V AC/DC on 250V AC/DC maximum. 3. Full-wave rectification Since the LED lamp is AC/DC compatible, a diode bridge for recti- fication is not necessary. If the LED lamp is used on a full-wave rec tification current through a diode bridge, the rectifier diodes will reduce the voltage, resulting in lower luminance. 4. Single-phase half-wave rectification This is not suitable for the power source of LED lamps. Use con- stant-voltage DC power. Noise LED elements deteriorate due to extraneous noise, resulting in sig nificant decrease in luminance, hue change, or failure of lighting. When such effects are anticipated, take a protection measure shown below, such as RC elements or a surge absorber. [Protection Example 1] For AC circuit LED with transformer LED R C LEDRyRelay coil or solenoid R C LED with transformer (Reference values) R: 120Ω C: 0.1 µF [Protection Example 2] For DC circuit Ry LED DiodeRelay coil or solenoid Countermeasures against Dim Lighting 1 . Leakage currents through the transistors or a contact protection circuit may cause the LED lamp to illuminate dimly even when the output is off. 2. When the LED lamp is illuminated by a transistor output, take the following measure. [Circuit Example] Connect shunt resistor R in parallel with the LED lamp. R Io Io: Leakage current when the output is off R: Shunt resistor LED
Ordering Information
- When ordering, specify the Part No. and quantity.
- Replacement contact blocks are supplied in a package containing 10 pieces. ø22 YW Series Emergency Stop Switches
ø30 mm, 4-contact Emergency Stop Switch. Padlockable and flush bezel are available. Direct Opening Action
- Padlockable, flush bezel, ø60mm jumbo mushroom, illuminated, LED push-on are available.
- IDEC’s original “Safe break action” and reverse energy struc- ture ensure the highest level of safety.
- Safety lock mechanism (IEC 60947 -5-5, 6.2)
- Direct opening action mechanism (IEC 60947 -5-5, 5.2, IEC60947 -5-1, Annex K)
- Short depth behind the panel – only 47 .7 mm for 4-contact, illumi nated (flush bezel: 60.4 mm, padlockable: 61 .4 mm)
- Padlockable can be locked using padlocks when latched (main contact: OFF). The rugged aluminum diecast shroud allows for installing a maximum of 20 padlocks using a hasp (total weight: 1500g maximum).
- Gold-plated silver contacts.
- Red (Munsell 5R4/12) or bright red (Munsell 7 .5R4.5/14) colors are available. Standards Applicable Standards Mark File No. or Organization UL508 CSA C22.2 No. 14 UL/c-UL File No. E68961 IEC60947 -5-5 UL991 NFPA79 UL Listing File No. E305148 EN60947 -5-5 TÜV SÜD EU Low Voltage Directive GB14048.5 CCC No. 2008010305290010 Contact Ratings NC main contacts/NO monitor contacts Rated Insulation Voltage (Ui) 250V Rated Thermal Current (Ith) 5A Rated Operating Voltage (Ue) 30V 125V 250V Rated Operating Current Main Contacts AC Hz Resistive Load (AC-12) – 5A 3A Inductive Load (AC-15) – 3A 1 .5A DC Resistive Load (DC-12) 2A 0.4A 0.2A Inductive Load (DC-13) 1A 0.22A 0.1A Monitor Contacts AC Hz Resistive Load Inductive Load DC Resistive Load (DC-12) 2A 0.4A 0.2A Inductive Load (DC-13) 1A 0.22A 0.1A Contact Material Gold-plated Silver
- Minimum applicable load: 5V AC/DC, 1 mA (reference value) (May vary depending on the operating conditions and load types.)
- The rated operating currents are measured at resistive/inductive load types specified in IEC 60947 -5-1 . Illumination Ratings (LED) Rated Voltage Operating Voltage Rated Current 24V AC/DC 24V AC/DC ±10% 15 mA Specifications Applicable Standards IEC60947 -5-1, EN60947 -5-1 IEC60947 -5-5, EN60947 -5-5 JIS C8201-5-1, UL508, UL991, NFPA79 CSA C22.2 No. 14, GB14048.5 Operating Temperature Non-illuminated: –25 to +60°C (no freezing) Illuminated: –25 to +55°C (no freezing) Storage Temperature –45 to +80°C Operating Humidity 45 to 85% RH (no condensation) Minimum Force Required for Direct Opening Action 80N Minimum Operator Stroke Required for Direct Opening Action 4.0 mm Maximum Operator Stroke 4.5 mm Contact Resistance 50 mΩ maximum (initial value) Insulation Resistance 100 MΩ minimum (500V DC megger) Overvoltage Category II Impulse Withstand Voltage 2.5 kV Pollution Degree 3 Operating Frequency 900 operations/hour Shock Resistance Operating extremes: 150 m/s2 Damage limits: 1000 m/s2 Vibration Resistance Operating extremes: 10 to 500 Hz, amplitude 0.35 mm, acceleration 50 m/s2 Damage limits: 10 to 500 Hz, amplitude 0.35 mm, acceleration 50 m/s Durability (at 900 operations/h, on-duration 40%) Mechanical: 250,000 operations minimum Electrical: 100,000 operations minimum 250,000 operations minimum (24V AC/DC, 100 mA) Degree of Protection Operator: IP65 (IEC60529) Terminal: IP20 (when XW9Z-VL2MF is installed) Short-circuit Protection 250V/10A fuse (Type aM, IEC60269-1/IEC60269-2) Conditional Short-circuit Current 1000A Terminal Style M3 screw terminal Recommended Tighten ing Torque for Terminal Screw 0.6 to 1 .0 N·m Recommended Tighten ing Torque for Locking Ring 2.5 N·m Applicable Wire Size 0.75 to 1 .25 mm 2 (AWG18 to 16) Total Weight of a Hasp and Padlocks 1500g maximum (padlockable) Reinforced Insulation (IEC 60664-1) Between live part and metal bezel (flush bezel, padlockable) Weight 83g (XN1E-LV404Q4MR) 93g (XN1E-BV504MR) 89g (XN5E-LV404Q4MR) 120g (XN4E-LL404Q4MR) XN Series Emergency Stop Switchesø30 XN
Non-illuminated Pushlock Pull/Turn Reset (Screw Terminal) Shape NC Main Contact NO Monitor Contact Part No. ➀Operator Color CodeIP20 Fingersafe Terminal w/Terminal Cover ø40mm Mushroom 1NC — XN1E-BV401MF➀ XN1E-BV401M➀ R: Red RH: Bright red 2NC — XN1E-BV402MF➀ XN1E-BV402M➀ 3NC — XN1E-BV403MF➀ XN1E-BV403M➀ 4NC — XN1E-BV404MF➀ XN1E-BV404M➀ 1NC 1NO XN1E-BV411MF➀ XN1E-BV411M➀ 2NC 1NO XN1E-BV412MF➀ XN1E-BV412M➀ 3NC 1NO XN1E-BV413MF➀ XN1E-BV413M➀ 2NC 2NO XN1E-BV422MF➀ XN1E-BV422M➀ ø60mm Jumbo Mushroom 1NC — XN1E-BV501MF➀ XN1E-BV501M➀ 2NC — XN1E-BV502MF➀ XN1E-BV502M➀ 3NC — XN1E-BV503MF➀ XN1E-BV503M➀ 4NC — XN1E-BV504MF➀ XN1E-BV504M➀ 1NC 1NO XN1E-BV511MF➀ XN1E-BV511M➀ 2NC 1NO XN1E-BV512MF➀ XN1E-BV512M➀ 3NC 1NO XN1E-BV513MF➀ XN1E-BV513M➀ 2NC 2NO XN1E-BV522MF➀ XN1E-BV522M➀
- Specify a color code in place of ➀ in the Part No.
- Only solid wires can be used on the IP20 fingersafe terminal switches. Illuminated Pushlock Pull/Turn Reset (Screw Terminal) Shape Illumination Rated Voltage NC Main Contact NO Monitor Contact Part No. Operator ColorIP20 Fingersafe Terminal w/Terminal Cover ø40mm Mushroom LED 24V AC/DC 1NC — XN1E-LV401Q4MFR XN1E-LV401Q4MR Red only 2NC — XN1E-LV402Q4MFR XN1E-LV402Q4MR 3NC — XN1E-LV403Q4MFR XN1E-LV403Q4MR 4NC — XN1E-LV404Q4MFR XN1E-LV404Q4MR 1NC 1NO XN1E-LV411Q4MFR XN1E-LV411Q4MR 2NC 1NO XN1E-LV412Q4MFR XN1E-LV412Q4MR 3NC 1NO XN1E-LV413Q4MFR XN1E-LV413Q4MR 2NC 2NO XN1E-LV422Q4MFR XN1E-LV422Q4MR
- Only solid wires can be used on the IP20 fingersafe terminal switches. Illuminated Push-ON Pushlock Pull/Turn Reset (Screw Terminal) Shape Illumination Rated Voltage NC Main Contact NO Monitor Contact Part No. Operator ColorIP20 Fingersafe Terminal w/Terminal Cover ø40mm Mushroom LED 24V AC/DC 2NC — XN1E-TV402Q4MFR XN1E-TV402Q4MR Red only3NC — XN1E-TV403Q4MFR XN1E-TV403Q4MR 2NC 1NO XN1E-TV412Q4MFR XN1E-TV412Q4MR
- Push-ON is illuminated when the operator is latched, and turns off when reset.
- Only solid wires can be used on the IP20 fingersafe terminal switches. ø30 XN Series Emergency Stop Switches
Non-illuminated Pushlock Pull/Turn Reset (Screw Terminal) Shape NC Main Contact NO Monitor Contact Part No. Operator Color CodeIP20 Fingersafe Terminal w/Terminal Cover ø40mm Mushroom 1NC — XN5E-BV401MF➀ XN5E-BV401M➀ R: Red RH: Bright red 2NC — XN5E-BV402MF➀ XN5E-BV402M➀ 3NC — XN5E-BV403MF➀ XN5E-BV403M➀ 4NC — XN5E-BV404MF➀ XN5E-BV404M➀ 1NC 1NO XN5E-BV411MF➀ XN5E-BV411M➀ 2NC 1NO XN5E-BV412MF➀ XN5E-BV412M➀ 3NC 1NO XN5E-BV413MF➀ XN5E-BV413M➀ 2NC 2NO XN5E-BV422MF➀ XN5E-BV422M➀
- Specify a color code in place of ➀ in the Part No.
- Only solid wires can be used on the IP20 fingersafe terminal switches. Illuminated Pushlock Pull/Turn Reset (Screw Terminal) Shape Illumination Rated Voltage NC Main Contact NO Monitor Contact Part No. Operator ColorIP20 Fingersafe Terminal w/Terminal Cover ø40mm Mushroom LED 24V AC/DC 1NC — XN5E-LV401Q4MFR XN5E-LV401Q4MR Red only 2NC — XN5E-LV402Q4MFR XN5E-LV402Q4MR 3NC — XN5E-LV403Q4MFR XN5E-LV403Q4MR 4NC — XN5E-LV404Q4MFR XN5E-LV404Q4MR 1NC 1NO XN5E-LV411Q4MFR XN5E-LV411Q4MR 2NC 1NO XN5E-LV412Q4MFR XN5E-LV412Q4MR 3NC 1NO XN5E-LV413Q4MFR XN5E-LV413Q4MR 2NC 2NO XN5E-LV422Q4MFR XN5E-LV422Q4MR
- Only solid wires can be used on the IP20 fingersafe terminal switches. Illuminated Push-ON Pushlock Pull/Turn Reset (Screw Terminal) Shape Illumination Rated Voltage NC Main Contact NO Monitor Contact Part No. Operator ColorIP20 Fingersafe Terminal w/Terminal Cover ø40mm Mushroom LED 24V AC/DC 2NC — XN5E-TV402Q4MFR XN5E-TV402Q4MR Red only3NC — XN5E-TV403Q4MFR XN5E-TV403Q4MR 2NC 1NO XN5E-TV412Q4MFR XN5E-TV412Q4MR
- Push-ON is illuminated when the operator is latched, and turns off when reset.
- Only solid wires can be used on the IP20 fingersafe terminal switches. XN Series Emergency Stop Switches ø30 XN
Non-illuminated Pushlock Turn Reset (Padlockable) (Screw Terminal) Shape NC Main Contact NO Monitor Contact Part No. Operator ColorIP20 Fingersafe Terminal w/Terminal Cover ø44mm Mushroom 1NC — XN4E-BL401MFRH XN4E-BL401MRH Bright red only 2NC — XN4E-BL402MFRH XN4E-BL402MRH 3NC — XN4E-BL403MFRH XN4E-BL403MRH 4NC — XN4E-BL404MFRH XN4E-BL404MRH 1NC 1NO XN4E-BL411MFRH XN4E-BL411MRH 2NC 1NO XN4E-BL412MFRH XN4E-BL412MRH 3NC 1NO XN4E-BL413MFRH XN4E-BL413MRH 2NC 2NO XN4E-BL422MFRH XN4E-BL422MRH
- Only solid wires can be used on the IP20 fingersafe terminal switches.
- Padlocks and hasps are not supplied with the emergency stop switches and must be ordered separately. See page 53. Illuminated Pushlock Turn Reset (Padlockable) (Screw Terminal) Shape Illumination Rated Voltage NC Main Contact NO Monitor Contact Part No. Operator ColorIP20 Fingersafe Terminal w/Terminal Cover ø44mm Mushroom LED 24V AC/DC 1NC — XN4E-LL401Q4MFR XN4E-LL401Q4MR Red only 2NC — XN4E-LL402Q4MFR XN4E-LL402Q4MR 3NC — XN4E-LL403Q4MFR XN4E-LL403Q4MR 4NC — XN4E-LL404Q4MFR XN4E-LL404Q4MR 1NC 1NO XN4E-LL411Q4MFR XN4E-LL411Q4MR 2NC 1NO XN4E-LL412Q4MFR XN4E-LL412Q4MR 3NC 1NO XN4E-LL413Q4MFR XN4E-LL413Q4MR 2NC 2NO XN4E-LL422Q4MFR XN4E-LL422Q4MR
- Only solid wires can be used on the IP20 fingersafe terminal switches.
- Padlocks and hasps are not supplied with the emergency stop switches and must be ordered separately. See page 53. LED Push-ON Pushlock Turn Reset (Padlockable) (Screw Terminal) Shape Illumination Rated Voltage NC Main Contact NO Monitor Contact Part No. Operator ColorIP20 Fingersafe Terminal w/Terminal Cover ø44mm Mushroom LED 24V AC/DC 2NC — XN4E-TL402Q4MFR XN4E-TL402Q4MR Red only3NC — XN4E-TL403Q4MFR XN4E-TL403Q4MR 2NC 1NO XN4E-TL412Q4MFR XN4E-TL412Q4MR
- Push-ON is illuminated when the operator is latched, and turns off when reset.
- Only solid wires can be used on the IP20 fingersafe terminal switches.
- Padlocks and hasps are not supplied with the emergency stop switches and must be ordered separately. See page 53. ø30 XN Series Emergency Stop Switches
3347.7 20.1 18.537 ø40 33.0 +0.5 4.8 +0.2 ø30.5 R0.8m ax. +0.5 Panel Cut-out Panel Thickness 1 to 5IP20 Cover XW9Z-VL2MF ø40 mm Mushroom ø60 mm Jumbo Mushroom ø60 Rubber Gasket Locking Ring M3 Terminal Screws 3347.7 20.1 18.5 ø40 Panel Thickness 1 to 5 Terminal Cover XW9Z-VL2M Rubber Gasket Locking Ring M3 Terminal Screws 33.0 +0.5 4.8 +0.2 R0.8 max. ø30.5 +0.50 Panel Cut-out ø40 mm Mushroom ø60 mm Jumbo Mushroom ø60 Push-ONIlluminated 3347.7 20.1 18.537 33.0 +0.5 4.8 +0.2 R0.8 max. ø30.5 +0.50 Panel Cut-out Rubber Gasket Locking Ring M3 Terminal Screws IP20 Cover XW9Z-VL2MF Panel Thickness 1 to 5 ø40 Push-ONIlluminated 3347.7 20.1 18.537 33.0 +0.5 4.8 +0.2 R0.8 max. ø30.5 +0.50 Panel Cut-out Panel Thickness 1 to 5Terminal Cover XW9Z-VL2M Rubber Gasket Locking Ring M3 Terminal Screws ø40 w/Terminal Cover w/Terminal CoverIP20 Fingersafe Non-Illuminated All dimensions in mm. Flush Bezel IP20 Fingersafe w/Terminal Cover Illuminated/Push-ON IP20 Fingersafe w/Terminal Cover ø40 33.0 +0.5 4.8 +0.2 ø30.5 R0.8m ax. +0.5 Panel Cut-out ø41 2160.4 20.1 18.5 Panel Thickness 1 to 5 Rubber GasketLocking Ring M3 Terminal Screws IP20 Cover XW9Z-VL2MF ø41 2160.4 20.1 18.537 ø40 33.0 +0.5 4.8 +0.2 ø30.5 R0.8 max. +0.5 Panel Cut-out Panel Thickness 1 to 5Terminal Cover XW9Z-VL2M Rubber GasketLocking Ring M3 Terminal Screws Push-ONIlluminated ø41 2160.4 20.1 18.537 Rubber GasketLocking Ring M3 Terminal Screws ø40 33.0 +0.5 4.8 +0.2 ø30.5 R0.8 max. +0.5 Panel Cut-out Panel Thickness 1 to 5Terminal Cover XW9Z-VL2M Push-ONIlluminated ø40 ø41 2160.4 20.1 18.537 33.0 +0.5 4.8 +0.2 ø30.5 R0.8 max. +0.5 Panel Cut-out Panel Thickness 1 to 5IP20 Cover XW9Z-VL2MF Rubber GasketLocking Ring M3 Terminal Screws XN Series Emergency Stop Switches ø30 XN
Mounting Hole Layout LED Unit Internal Circuit Terminal Arrangement (Bottom View) 61.4 59.9 20.1 18.537 ø44 33.0 +0.5 4.8 +0.2 R0.8 max. ø30.5 +0.50 Panel Cut-out Rubber GasketLocking Ring M3 Terminal Screws IP20 Cover XW9Z-VL2MF Panel Thickness 1 to 6 Panel Thickness 1 to 6IP20 Cover XW9Z-VL2MF 33.0 +0.5 4.8 +0.2 R0.8 max. ø30. 5 +0.50 Panel Cut-out 61.4 59.9 20.1 18.5 Rubber GasketLocking Ring M3 Terminal Screws Push-ONIlluminated 61.4 59.9 20.1 18.5 ø44 33.0 +0.5 4.8 +0.2 R0.8 max. ø30.5 +0.50 Panel Cut-out Panel Thickness 1 to 6Terminal Cover XW9Z-VL2M Rubber GasketLocking Ring M3 Terminal ScrewsPush-ONIlluminated Non-illuminated Illuminated/Push-ON Padlockable IP20 Fingersafe w/Terminal Cover w/Terminal CoverIP20 Fingersafe 61.4 20.1 18.5 ø44 33.0 +0.5 4.8 +0.2 R0.8 max. ø30.5 +0.5 Panel Cut-out Rubber GasketLocking Ring M3 Terminal Screws Panel Thickness 1 to 6Terminal Cover XW9Z-VL2M ø30.5 +0.5 X Y R LED LED chip Protection Diode Resistor X Y Plastic Bezel 70 mm minimumFlush Bezel
- The values shown above are the minimum dimen- sions for mounting with other ø30 mm pushbuttons. For other control units of different sizes and styles, determine the values according to the dimensions, operation, and wiring convenience.
- For padlockable, determine the values accord ing to the size and number of padlocks and hasp. TOP Left Right TOP Left Right TOP Left Right ∗1 ∗2 ∗1 ∗2 ∗2 ∗1 ∗1 ∗2 ∗4 ∗3 ∗3 ∗4 ∗4 ∗3 ∗1 ∗2 ∗2 ∗1 ∗1 ∗2 ∗2 ∗1 ∗2 ∗1 TOP LED Left Right TOP LED Left Right TOP LED Left Right ∗1 ∗2 ∗4 ∗3 ∗1 ∗2 ∗2 ∗1 ∗3 ∗4 ∗4 ∗3 ∗1 ∗2 ∗2 ∗1 ∗1 ∗2 ∗1 ∗2 ∗2 ∗1 ∗2 ∗1 LED TOP X1 X2 Left Right ∗1 ∗2 ∗1 ∗2 ∗2 ∗1 LED TOP X1 X2 Left Right ∗3 ∗4 ∗1 ∗2 ∗2 ∗1
- Contact
- Contact Number (1-4) TOP (Example: 1NO-3NC contact) Left Right 11 12 34 33 21 22 42 41 1-2: NC main contact (black) 3-4: NO monitor contact (blue) Starting with the contact of TOP side, in a counter- clockwise direction. ø3.2 min. Wire Insulation Tube Crimping Terminal
- Be sure to install an insulating tube on the crimping terminal. Only solid wire can be used for IP20. Applicable Crimping Terminal Ring Terminal Spade Terminal Solid Wire 4.7 to 5.9 ø6.0 max. 4.7min. 6.2 max. ø1.2 max. 3.0 max. 4.7 to 5.9 4.7 to 5.9 3.2 min. 6.0 max. Crimping Terminal Insulation Tube Wire With 1NO monitor contact NC main contacts only 1NC: Terminals on right 2NC: Terminals on right and left 3NC: Terminals on right, left, and top 1NC: Terminals on top 2NC: Terminals on right and left Non-illuminated Illuminated With 2NO monitor contacts With 1NO monitor contact NC main contacts only With 2NO monitor contacts 1NC: Terminals on right 2NC: Terminals on right and left 3NC: Terminals on right, left, and top 1NC: Terminals on top 2NC: Terminals on right and left Push-ON With 1NO monitor contact NC main contacts only 2NC: T erminals on right and left 3NC: Terminals on right, left, and top All dimensions in mm. ø30 XN Series Emergency Stop Switches
Accessories and Replacement Parts Name & Shape Material Part No. Ordering No. Package Quantity Remarks PPE XW9Z-VL2M XW9Z-VL2MPN02 2
- Black
- Used for screw terminals.
- Attached to IP20 protection cover units. Polyamide XW9Z-VL2MF XW9Z-VL2MFPN02 2
- Black
- Used to change terminal cover to IP20 fingersafe terminal.
- Only solid wires can be used. Once installed, IP20 terminal cover cannot be removed. Brass XN9Z-T1 XN9Z-T1 1
- Used to tighten the locking ring when installing the XN emergency stop switch onto a panel. Steel Trivalent chromate plating TWST-T1 TWST-T1 1
- Used to tighten the locking ring when installing the XN emergency stop switch onto a panel.
- The XN series emergency stop switches are supplied with either terminal cover or IP20 fingersafe terminal cover.
- Padlocks and hasps are not supplied and must be ordered separately. Nameplates (for ø30 Emergency Stop Switches) Description & Shape Legend Part No. Package Quantity Dimensions (mm) (blank) HNAV-0 Polyamide Mounting panel thickness XN4E-L4: 1 .0 to 4.5 mm XNE-V4: 1 .0 to3.5 mm EMERGENCY STOP HNAV-27 Plate color: Y ellow (Munsell 2.5Y 8/10 or equivalent), Legend: Black Padlock and Hasp Padlocks and hasps of the following specifications can be used with padlockable emergency stop switches. Padlock Size a b c d 7 mm maximum 19 mm minimum 39 mm minimum 15 mm minimum (Note) Note: When the padlock is installed from the side of the bezel, dimension d requires a minimum of 6 mm. When the padlock is installed from the front of the button, dimension d requires a minimum of 15 mm. Terminal Cover IP20 Fingersafe Terminal Cover Ring Wrench ø38 Ring Wrench 49.5 20.5 23.77 7 1.01.5 ø60 ø30 XN Series Emergency Stop Switches ø30 ̱ ̰ d Recommended Hasp Maker Part No. PANDUIT CORP . PSL-HD3 PSL-1A Master Lock® Company LLC 420, 421 Use only padlocks or hasps that satisfy the specifications shown on the left. The maximum total weight for padlocks and hasps is 1500g. Make sure that the total weight does not exceed 1500g, otherwise the XN emergency stop switch may be damaged. Make sure that locking and unlocking of the padlock and hasp do not interfere with other devices. Padlocks and hasps are available from the following manufacturers. Manufacturer URL PANDUIT CORP . http://www.panduit.com/ Master Lock® Company LLC http://www.masterlock.com/ XN
Removing the Contact Block First unlock the operator button. Grab the yellow bayonet ring ➀ and pull back the bayonet ring until the latch pin clicks ➁, then turn the contact block counter clockwise and pull out ➂. Notes for removing the contact block 1 . Do not attempt to remove the contact block while the oper ator is latched, otherwise the switch may be damaged. 2. When the contact block is removed, the monitor contact (NO contact) is closed. 3. While removing the contact block, do not use excessive force, otherwise the switch may be damaged. 4. An LED lamp is built into the contact block for illuminated pushbuttons. When removing the contact block, pull the contact block straight to prevent damage to the LED lamp. If excessive force is used, the LED lamp may be damaged and fail to light. Panel Mounting Remove the locking ring from Rubber Gasket Operator without thread TOP Marking Anti-rotation Projection Locking Ring the operator and check that the rubber gasket is in place. Insert the operator from panel front into the panel hole. Face the side without thread on the operator with TOP marking upward, and tighten the lock ing ring using ring wrench XN9Z-T1 or TWST -T1 to a torque of 2.5 N·m maximum. When using a nameplate When using a nameplate HNAV-, break the projection from the nameplate using pliers. Installing the Contact Block First unlock the operator button. Align the small ▼ marking on the edge of the operator with the small ▲ marking on the yellow bayonet ring. Hold the contact block, not the bayonet ring. Press the contact block onto the operator and turn the contact block clockwise until the bayo net ring clicks. Notes for installing the contact block 1 . Do not attempt to install the contact block when the opera tor is latched, otherwise the switch may be damaged. 2. Make sure that the bayonet ring is in the locked position. Installing & Removing Terminal Covers XW9Z-VL2M To install the terminal cover, align the TOP marking on the terminal cover with the TOP marking on the contact block. Place the two projec- tions on the bottom side of the contact block into the slots in the terminal cover. Press the terminal cover toward the contact block. To remove the terminal cover, pull out the two latches on the top side of the terminal cover. Do not exert excessive force to the latches, otherwise the latches may break. IP20 Fingersafe Terminal Cover XW9Z-VL2MF To install the IP20 fingersafe terminal cover, align the TOP marking on the cover with the TOP marking on the contact block, and press the cover toward the contact block. Notes: 1 . Once installed, the XW9Z-VL2MF cannot be removed. 2. With the XW9Z-VL2MF installed, crimping terminals cannot be used. Use solid wires. 3. The XW9Z-VL2MF cannot be installed after wiring. 4. Make sure that the XW9Z-VL2MF is securely installed. IP20 cannot be achieved when installed loosely, and electric shocks may occur. Notes for Operation When using the XN emergency stop switches in safety- related part of a control system, observe safety standards and regulations of the relevant country or region. Also be sure to perform a risk assessment before operation. Wiring Tighten the M3 terminal screws to a torque of 0.6 to 1 .0 N·m. Contact Bounce When the button is reset by pulling or turning, the NC main contacts will bounce. When pressing the button, the NO monitor contacts will bounce. When designing a control circuit, take the contact bounce time into consideration (reference value: 20 ms). LED Illuminated Switches An LED lamp is built into the contact block and cannot be replaced. Handling Do not expose the switch to excessive shocks and vibra- tions, for example by operating the switch with tools. Other- wise the switch may be deformed or damaged, causing malfunction or operation failure. ø30 XN Series Emergency Stop Switches /uni2780 Place the projections on the contact block. TOP Markings /uni2781 Press the terminal cover Projections Slots (Pull) TOP Marking TOP Marking Projections (Press) TOP Marking TOP Marking ▲ Marking▼ Marking /uni2780 PushTOP Marking /uni2781 Turn clockwise Projection /uni2780 Grab /uni2780 Grab Latch Bayonet Ring (yellow) /uni2781 Pull /uni2782 Turn counterclockwise
Emergency Stop Switches (Unibody) Specifications Standards Applicable Standards Mark File No. or Organization UL508 CSA C22.2 No. 14 UL Listing File No. E55996 EN60947 -5-5 TÜV SÜD EU Low Voltage Directive GB14048.5 CCC No. 2013010305610376 Contact Ratings Rated Insulation Voltage (Ui) 250V Rated Thermal Current (Ith) 10A Rated Operational Voltage (Ue) 24V 110V 220V Rated Operational Current AC Hz Resistive Load (AC-12) 6A 3A 3A Inductive Load (AC-15) 6A 3A 3A DC Resistive Load (DC-12) 6A 2A 1A Inductive Load (DC-13) 1 .5A 0.3A 0.15A Note: The operational current represents the classification by making and breaking currents (IEC 60947 -5-1). Minimum applicable load (reference value): 3V AC/DC, 5 mA (Applicable range may vary with operating condi tions and load types.) LED Lamp Ratings Rated Operating Voltage of Unit LED Lamp Part No. Rated Voltage Rated Current 24V AC/DC LSTD-2R 24V AC/DC ±10% 10 mA Incandescent Lamp Ratings Unit Rated Operating Voltage Incandescent Lamp Part No. Wattage 24V AC/DC LS-3 1W (30V) Specifications Operating Temperature –25 to +60°C (no freezing) Illuminated units: –25 to +55°C Storage Temperature –40 to +80°C Operating Humidity 45 to 85% RH (no condensation) Operating Force 50N Minimum Force Required for Direct Opening Action 5.5 mm Maximum Operator Stroke 10 mm Contact Resistance 50 mΩ maximum (initial value) Insulation Resistance 100 MΩ minimum (500V DC megger) Dielectric Strength Between live and dead metal parts Contacts: 2,500V AC, 1 minute Illuminated parts: 1,000V AC, 1 minute Vibration Resistance Damage limits: 30 Hz, amplitude 1 .5 mm Operating extremes: 5 to 55 Hz, amplitude 0.5 mm Shock Resistance Damage limits: 1,000 m/s2 Operating extremes: 100 m/s2 Operating Frequency 900 operations/h Life Mechanical: 250,000 operations minimum Electrical: 100,000 operations minimum Degree of Protection IP65 Terminal Style M3.5 screw Weight (approx.) 58g (HN1E-BV402R) 65g (HN1E-LV402Q4R) HN Series Emergency Stop Switchesø30 Pushlock Turn Reset Switches (Unibody) Shape Contact Part No. Button Color 1NO-1NC HN1E-BV411R Red only 2NC HN1E-BV402R
- When pressed, the button is held depressed. The button is released by turning clockwise.
- Terminal cover HW-VL7 is supplied with the switch. Illuminated Pushlock Turn Reset Switches (Unibody) Shape Lamp Contact Part No. Lens Color Without Lamp 1NO-1NC HN1E-LV411Q0R Red only 2NC HN1E-LV402Q0R
- When pressed, the button is held depressed. The button is released by turning clockwise.
- Terminal cover HW-VL7 is supplied with the switch. Maintenance Parts Name Part No. Ordering No. Package Quantity Terminal Cover for HW1E HW-VL7 HW-VL7PN10 10 HN
Shape Material Part No. Package Quantity Remarks Ring Wrench Metal TWST-T1 1 Used for tightening the locking nut. Tighten the locking nut to a torque of 2.0 to 2.5 N·m. Ring Wrench Brass XN9Z-T1 1
- Used to tighten the locking ring when installing the XN emergen- cy stop switch onto a panel. Nameplates (for ø30 Emergency Stop Switches) Shape Part No. Legend Package Quantity Remarks HNAV-0 (blank) 1.01.5 ø60 ø30 Background: Y ellow Legend: Black Applicable panel thickness: 0.8 to 4.5 mm Material: Polyamide Legend “EMERGENCY STOP” is indicated outside a ø44mm circle. HNAV-27 EMERGENCY STOP Terminal Arrangement (Bottom View) TOP Marking Side Locking Ring 23.5 ø40 M3.5 Terminal Screw Gasket 0.5 Panel Thickness 0.8 to 6 22 (NC) 21 (NC) 13 (NO) 14 (NO) R0.8 max. +0.2 4.8 +0.5 ø30.5 HN1E-BV4 LAMP 0.5 23.5 M3.5 Terminal Screw M3.5 Terminal Screw Gasket Panel Thickness 0.8 to 6 ø40Locking RingLamp Terminal Terminal Arrangement (Bottom View) TOP Marking Side 22 (NC) 21 (NC) 13 (NO) 14 (NO) All dimensions in mm. 49.5 20.5 23.77 7 ø38 ø30 HN Series Emergency Stop Switches
HN Series Emergency Stop Switches ø30 Panel Mounting Tighten the locking ring using ring wrench XN9Z-T1 or TWST-T1 to a torque of 2.0 N·m maximum. Do not use pliers. Excessive tightening will damage the locking ring. Installing and Removing the Lens There is a groove each on the right and left of the lens. Insert a flat screwdriver into one of them and push upward. Take care not lose a lens. Replacing the LED lamp Use the lamp holder tool (OR-55) to replace the LED lamp from the front of the panel. [How to Remove] To remove, slip the lamp holder tool (OR-55) onto the lamp head lightly. Then push slightly, and turn the lamp holder tool counterclockwise. [How to Install] To install, insert the lamp head into the lamp holder tool (OR-55). Lamp Lamp Holder Tool Place the pins on the lamp base to the grooves in the lamp socket. Inset the lamp and turn it clockwise. Base Do not apply excessive force onto the lamp in the base, otherwise the base will be damaged. Notice on Wiring When wiring, provide sufficient insulation between wires (crimping terminals). Recommended Tightening Torque 1.0 to 1.3 N∙m
- Turn off the power to the HN series before starting installa- tion, removal, wiring, maintenance, and inspection. Failure to turn power off may cause electrical shocks or fire haz- ard.
- To avoid a burn on your hand, use the lamp holder tool when replacing lamps.
- For wiring, use wires of a proper size to meet the volt- age and current requirements. Tighten the M3.5 terminal screws to a tightening torque of 1 .0 to 1 .3 N·m. Failure to tighten terminal screws may cause overheat and fire. Safety Precautions Operating Instructions HN
ø16mm XA Series EMO Switches Panel Cut-out ø29.8 ø40 +0.2 17.9 +0.21.7 +0.2 ø16. 30.4 19.8 8.7 2.1 27.2 25.8 30.4 20.6 Rubber Gasket Locking Ring Terminal Cover XA9Z-VL2 Panel Thickness 0.5 to 3.7 Solder Terminal ø22mm HW Series EMO Switches ø22mm XW Series EMO Switches Panel Cut-out XW9Z-VL2M Terminal Cover Locking Ring 20.118.5 48.7 47.2 0.5 +0.4 ø22.3 R0.8 max. +0.424.1 +0.2 3.2 32.2 Panel Thickness 0.8 to 6 20.118.5 XW9Z-VL2MF Terminal Cover Locking Ring Panel Thickness 0.8 to 6 Rubber GasketM3 Terminal ScrewRubber GasketM3 Terminal Screw 48.7 47.2 32.2 Panel Cut-out +0.4 ø22.3 R0.8 max. +0.424.1 +0.2 3.20.5 All dimensions in mm. 1349.4 (1 or 2 blocks) 69.4 (4 blocksʣ 32 Locking Ring 41.4 29.4 26.5 Lock Lever LOCK 1 contact block 2 contact blocks 4 contact blocks SEMI Emergency Off (EMO) Switches ø16mm XA Series EMO Switches (Solder Terminal) (Pushlock Turn Reset Switch) Package Quantity: 1 Shape NC Main Contact NO Monitor Contact Part No. ø40mm Mushroom 1NC — XA1E-BV401RH-EMO 2NC — XA1E-BV402RH-EMO 3NC — XA1E-BV403RH-EMO 4NC — XA1E-BV404RH-EMO 1NC 1NO XA1E-BV411RH-EMO 2NC 1NO XA1E-BV412RH-EMO 3NC 1NO XA1E-BV413RH-EMO
- Button color is bright red (RH).
- For detailed specifications and instructions, see page 15. ø22mm XW Series EMO Switch (Pushlock Turn Reset Switch) Package Quantity: 1 Shape NC Main Contact NO Monitor Contact Part No. IP20 Fingersafe Terminal w/Terminal Cover ø40mm Mushroom 1NC — XW1E-BV401MFRH-EMO XW1E-BV401MRH-EMO 2NC — XW1E-BV402MFRH-EMO XW1E-BV402MRH-EMO 3NC — XW1E-BV403MFRH-EMO XW1E-BV403MRH-EMO 4NC — XW1E-BV404MFRH-EMO XW1E-BV404MRH-EMO 1NC 1NO XW1E-BV411MFRH-EMO XW1E-BV411MRH-EMO 2NC 1NO XW1E-BV412MFRH-EMO XW1E-BV412MRH-EMO 3NC 1NO XW1E-BV413MFRH-EMO XW1E-BV413MRH-EMO 2NC 2NO XW1E-BV422MFRH-EMO XW1E-BV422MRH-EMO
- Button color is bright red (RH).
- For detailed specifications and instructions, see page 21. ø22mm HW Series EMO Switches (Screw Terminal) (Pushlock Turn Reset Switch) Package Quantity: 1 Shape Contact Arrangement Part No. Button Color ø40mm Mushroom 1NC HW1B-V401R-EMO Red only 1NO-1NC HW1B-V411R-EMO 2NC HW1B-V402R-EMO 2NO-2NC HW1B-V422R-EMO
- For detailed specifications and instructions, see page 34.
SEMI S2-compliant Combinations EMO Switch Guard Applicable Emergency Stop Switches XA9Z-KG1 XA1E-BV4**-EMO ( ), XA1E-BV3 ( ), XA1E-LV3 ( ), XA1E-BV4 ( ), XA1E-LV4 ( ) HW9Z-KG3 XW1E-BV4-EMO ( ), XW1E-BV4 ( ), XW1E-LV4 ( ), XW1E-TV4 ( ), HW1B-V3 ( ), HW1B-V4 ( ), HW1B-X4 ( ), HW1B-Y2 ( ) HW9Z-KG4 XW1E-BV4-EMO ( ), XW1E-BV4 ( ), XW1E-LV4 ( ), XW1E-TV4 ( ), XW1E-BV5 ( ) HW1B-V3 ( ), HW1B-V4 ( ), HW1E ( ), HW1B-X4 ( ), HW1B-Y2 ( ) HW9Z-KG5 XW1E-BV4**-EMO ( ), XW1E-BV4 ( ), XW1E-LV4 ( ), XW1E-TV4 ( ), XW1E-BV5 ( ), HW1B-V3 ( ), HW1B-V4 ( ), HW1E ( ), HW1B-X4 ( ), HW1B-Y2 ( ) Note: EMO switch guards have been designed for applications in semiconductor manufacturing equipment only. Do not use EMO switch guards with emergency stop switches which are installed on machine tools or food processing machines. (Machinery Directive of the European Commission and IEC 60204-1 require that emergency stop switches be installed in a readily accessible area, and the usage of switch guards is not permitted.) About SEMI SEMI is an international industry association whose member companies produce materials, equipment, and related technology for manufacturing semiconductor, flat panel display (FPD), and micro-electromechanical systems (MEMS) products. The SEMI safety guideline was published for the semiconductor industry and it is observed with the same importance as standards. SEMI S2-0706, 12.1 describes as follows; “The equipment should have an ‘emergency off’ (EMO) circuit. The EMO actuator (e.g., button), when activated, should place the equipment into a safe shutdown condition, without generating any additional hazard to personnel or the facility.” Because the semiconductor environment involves solvents and chemicals in many cases, some of which are toxic, interrupting the power source may cause secondary accidents. SEMI safety guideline requires the installation of an emergency off switch which disconnects only the part responsible for the hazardous situation, and maintains the functions of safety-related devices (e.g., smoke detectors, gas/water leak detectors, pressure measurement devices, etc.). Emergency off buttons should be located or guarded to minimize accidental activation (SEMI S2-0706, 12.5.1). The emergency off button should be red and mushroom shaped. A yellow background for the EMO should be provided (SEMI S2-0706, 12.3). The combination of IDEC’s EMO switch guards and emergency stop switches are approved by TÜV Rheinland for compliance with SEMI S2 standards. XA9Z-KG1 HW9Z-KG3 HW9Z-KG4 HW9Z-KG5 838 mm minimum 1638 mm maximum (3 m maximum) (3 m maximum) EMO button EMO buttonOperator
- Location of EMO switches on semiconductor manufacturing equipment Acceptance criteria: controls should not be located above 1638 mm (64.5 in.) or below 838 mm (33 in.)
- No operation or regularly scheduled maintenance location should require more than 3 m (10 feet) travel to an EMO button (S2-0706, 12.5.2). EMO
Switch Guards Package Quantity: 1 Series Description & Shape Part No. Applicable Switches Remarks ø16mm XA Series ø16 mm EMO Switch Guard XA9Z-KG1 XA1E-BV3 XA1E-BV4 XA1E-LV3 XA1E-LV4
- SEMI S2 compliant (The combination of IDEC’s emergency stop switches and EMO switch guards are approved by TÜV Rheinland for compliance with SEMI S2 standard.) ø22 mm EMO Switch Guard HW9Z-KG1 XW1E-BV4 XW1E-LV4 XW1E-TV4 HW1B-V3 HW1B-V4 HW1B-X4 HW1B-Y2 HW1E-BV4 HW1E-LV4
- SEMI S2-0703, 12.5.1 compliant.
- Widely used switch guard in many applications. ø22mm HW/XW Series ø22 mm EMO Switch Guard HW9Z-KG2 XW1E-BV4 XW1E-LV4 XW1E-TV4 HW1B-V3 HW1B-V4 HW1B-X4 HW1B-Y2 HW1E-BV4 HW1E-LV4
- SEMI S2-0703, 12.5.1 compliant.
- SEMATECH Application Guide for SEMI S2-93, 12.4. compliant.
- The round shape is effective to prevent inadvertent operation from any direction. ø22 mm EMO Switch Guard HW9Z-KG3 XW1E-BV4 XW1E-LV4 XW1E-TV4 HW1B-V3 HW1B-V4 HW1B-X4 HW1B-Y2
- SEMI S2 compliant (The combination of IDEC's emergency stop switches and EMO switch guards are approved by TÜV Rheinland for compliance with SEMI S2 standard.)
- The smallest switch guard for ø22 series switches.
- Can be installed on FB control boxes. ø22 mm EMO Switch Guard HW9Z-KG4* XW1E-BV4 XW1E-BV5 XW1E-LV4 XW1E-TV4 HW1B-V3 HW1B-V4 HW1B-X4 HW1B-Y2 HW1E-BV4 HW1E-LV4
- SEMI S2 compliant (The combination of IDEC's emergency stop switches and EMO switch guards are approved by TÜV Rheinland for compliance with SEMI S2 standard.)
- SEMATECH Application Guide for SEMI S2-93, 12.4. compliant.
- Narrower than HW9ZKG5. Saves more space.
- Can be installed on FB control boxes.
- Available in white. ø22 mm EMO Switch Guard HW9Z-KG5* XW1E-BV4 XW1E-LV4 XW1E-TV4 XW1E-BV5 HW1B-V3 HW1B-V4 HW1B-X4 HW1B-Y2 HW1E-BV4 HW1E-LV4
- SEMI S2 compliant (The combination of IDEC's emergency stop switches and EMO switch guards are approved by TÜV Rheinland for compliance with SEMI S2 standard.)
- SEMATECH Application Guide for SEMI S2-93, 12.4. compliant.
- A nameplate can be installed.
- Available in white.
- Specify a color code in place of *. Blank: yellow (Munsell 2.5Y8/10 or equivalent), -W: white (Munsell N9.5)
- Material: polyamide (PA6), degree of protection: IP65 (IEC 60529) SEMI S2 Compliant Switch Guards
When anti-rotation is not required or when the panel cut-out does not have anti-rotation recess, remove the projection using pliers. +0.2 The * 1.7 recess is for preventing rotation and not necessary when anti-rotation is not used. 24.1 +0.2 *3.2 0+0.4 ø22. Max. R0.8 +0.4 Panel Cut-out ø16mm ø22mm +0.2The * 3.2 recess is for preventing rotation and not necessary when anti-rotation is not used. +0.2 17.9 +0.2 ø16.2 +0.2 *1.7 SEMI EMO Switch Guards Dimensions
- Panel thickness: 1 .2 to 4.0 mm (1 .2 to 2.6 mm when using an HWAV nameplate) Gasket ø16 23.1 ø50 ø57 (1.7) (0.2) 36.550 ø22.2ø90 (2.2) (0.2) Gasket ø90 50 35 (2.2) (0.2) ø22 Gasketø41 3864 (0.2) (2) ø22 Gasket ø74 ø64 ø22 ø37 3542 (2.2) (0.2) Gasket SEMI S2 Compliant Switch Guards 36.2 ø76 ø90 ø90 ø22 (2) (0.2) Gasket XA9Z-KG1 HW9Z-KG3 HW9Z-KG1 HW9Z-KG4 HW9Z-KG2 HW9Z-KG5 3mm max. Note: The height of the applicable switch and guard will be 3 mm or less as shown in the diagram on the right. All dimensions in mm. Locking Ring TOP Marking TOP Marking Operator Button Panel Thickness: 1 to 2.2 TOP Marking Locking Ring Operator Button TOP Marking Panel Thickness: 1.2 to 4 Installation To tighten the locking ring, use locking ring wrench MT -100 and tighten to a torque of 0.88 N·m. To tighten the locking ring, use locking ring wrench MW9Z-T1 and tighten to a torque of 2.0 N·m. ø16 mm ø22 mm Nameplate (for ø22 mm Emergency Stop Switches) Name Legend Part No. Remarks For ø40mm Mushroom EMERGENCY OFF HWAV-74-Y
- Nameplate color: yellow
- Legend color: black ø22 1.01.5 ø60 EMO Sticker Part No.: HW9Z-EMO-NPP Color: Y ellow (red legend) Package Quantity: 10 EMO
ø16mm XA series Stop Switch Pushlock Pull or Turn Reset with Removable Contact Block Package quantity: 1 Description & Shape NC Main Contact NO Monitor Contact Part No. Solder Terminal PCB Terminal ø29mm Mushroom 1NC — XA1E-BV301➀ XA1E-BV301V➀ 2NC — XA1E-BV302➀ XA1E-BV302V➀ 3NC — XA1E-BV303➀ XA1E-BV303V➀ 4NC — XA1E-BV304➀ XA1E-BV304V➀ 1NC 1NO XA1E-BV311➀ XA1E-BV311V➀ 2NC 1NO XA1E-BV312➀ XA1E-BV312V➀ 3NC 1NO XA1E-BV313➀ XA1E-BV313V➀ ø40mm Mushroom 1NC — XA1E-BV401Y XA1E-BV401VY 2NC — XA1E-BV402Y XA1E-BV402VY 3NC — XA1E-BV403Y XA1E-BV403VY 4NC — XA1E-BV404Y XA1E-BV404VY 1NC 1NO XA1E-BV411Y XA1E-BV411VY 2NC 1NO XA1E-BV412Y XA1E-BV412VY 3NC 1NO XA1E-BV413Y XA1E-BV413VY
- Specify button color code Y (yellow) or N (gray) in place of ➀ in the Part No.
- Pushlock pull or turn reset is locked when pressed, and reset when pulled or turned clockwise.
- Terminal cover (XA9Z-VL2) is not supplied and must be ordered separately.
- See page 15 for specifications and instructions. ø16mm X6 series Stop Switch Pushlock Pull or Turn Reset Unibody (Solder Terminal) Package quantity: 1 Description & Shape Operator NC Main Contact Part No. (Photo: ø30mm Mushroom) ø30mm 1NC AB6E-3BV01PY 2NC AB6E-3BV02PY ø40mm 1NC AB6E-4BV01PY 2NC AB6E-4BV02PY
- Pushlock pull or turn reset is locked when pressed, and reset when pulled or turned clockwise.
- Do not use yellow stop switches as emergency stop switches.
- See page 8 for specifications and instructions. ø16mm XA series Stop Switch Pushlock Pull or Turn Reset Unibody (Solder Terminal) Package quantity: 1 Description & Shape Operator NC Main Terminal Part No. IP40 IP65 (Photo: ø29mm Mushroom) ø29mm 1NC XA1E-BV3U01K➀ XA1E-BV3U01➀ 2NC XA1E-BV3U02K➀ XA1E-BV3U02➀ ø40mm 1NC XA1E-BV4U01K➀ XA1E-BV4U01➀ 2NC XA1E-BV4U02K➀ XA1E-BV4U02➀
- Specify button color code Y (yellow) or N (gray) in place of ➀ in the Part No.
- Pushlock pull or turn reset is locked when pressed, and reset when pulled or turned clockwise.
- Solder/tab 110 terminal is available. To order, insert ”T” before the Y in the Part No. Example: XA1E-BV3U02KYXA1E-BV3U02KTY
- See page 13 for specifications and instructions. Stop Switches Wider variety with yellow button, white guard and nameplate According to SEMI S26-0308 Environmental, Health, and Safety Guideline for FPD Manufacturing Systems published in March 2008, the combination of a red button and yellow background cannot be used for switches that have only local or partial shut down functions. IDEC’s yellow button switch, white switch guard, and nameplate can satisfy the requirement.
ø22mm XW series Stop Switches Pushlock Pull / Turn Reset (Screw Terminal) Package quantity: 1 Description & Shape Main Contact Monitor Contact Part No. IP20 Terminal w/Terminal Cover ø40mm Mushroom 1NC — XW1E-BV401MFY XW1E-BV401MY 2NC — XW1E-BV402MFY XW1E-BV402MY 3NC — XW1E-BV403MFY XW1E-BV403MY 4NC — XW1E-BV404MFY XW1E-BV404MY 1NC 1NO XW1E-BV411MFY XW1E-BV411MY 2NC 1NO XW1E-BV412MFY XW1E-BV412MY 3NC 1NO XW1E-BV413MFY XW1E-BV413MY 2NC 2NO XW1E-BV422MFY XW1E-BV422MY
- Pushlock, pull or turn reset is locked when pressed, and reset when pulled or turned clockwise.
- Specify IP20 terminal or terminal cover with the Part No.
- IP20 terminal type can be connected using solid wires only.
- See page 21 for specifications and instructions. ø22mm HW series Stop Switches Package quantity: 1 Description & Shape Contact Configuration Part No. ø29mm Mushroom ø40mm Mushroom ø60mm Jumbo Mushroom Pushlock Turn Reset 1NC HW1B-V301Y HW1B-V401Y HW1B-V501Y 1NO-1NC HW1B-V311Y HW1B-V411Y HW1B-V511Y 2NC HW1B-V302Y HW1B-V402Y HW1B-V502Y 2NO-2NC HW1B-V322Y HW1B-V422Y HW1B-V522Y Push-Pull ø40mm Mushroom (2-position) 1NC — HW1B-Y201Y — 1NO-1NC — HW1B-Y211Y — 2NC — HW1B-Y202Y —
- Pushlock turn reset is locked when pressed, and reset when turned clockwise.
- Push-pull is a 2-position switch which is maintained in both pressed and reset (pull) positions.
- See page 32 for specifications and instructions. (Photo: ø29mm Mushroom)
Switch Guard (White) Description & Shape Part No. Remarks For ø22mm HW/XW Series HW9Z-KG4-W
- Inside diameter ø76mm
- Space-saving, 50 mm-wide. For ø22mm HW/XW Series HW9Z-KG5-W
- Inside diameter ø76mm Nameplates (White) Shape Description Part No. Material Plate Color Legend For ø16mm Series For ø29mm Mushroom HAAV-0-W Polyamide White (Munsell N9.5) Blank For ø49mm Mushroom HAAV4-0-W For ø22mm Series For ø40mm Mushroom HWAV-0-W For ø60mm Mushroom HWAV5-0-W For ø16mm Series (Nameplate for ø29mm Mushroom) (Nameplate for ø40mm Mushroom) For ø22mm Series (Nameplate for ø40mm Mushroom) (Nameplate for ø60mm Mushroom) Panel thickness: 0.5 to 2 mm when using a nameplate Panel thickness: 0.5 to 2 mm when using a nameplate ø43.5 ø16 1.7 0.3 0.51.7 ø60 ø16 ø60 ø22 1.01.5 2.3 0.6 ø22 ø80 Panel thickness: 0.8 to 4.5 mm when using a nameplate Panel thickness: 0.8 to 4 mm when using a nameplate Dimensions www.idec.com USA IDEC Corporation Tel: +1-408-747-0550 opencontact@idec.com Germany IDEC Elekrotechnik GmbH Tel: +49-40-25 30 54 - 0 service@eu.idec.com Singapore IDEC Izumi Asia Pte. Ltd. Tel: +65-6746-1155 info@sg.idec.com Thailand IDEC Asia (Thailand) Co., Ltd Tel: +66-2-392-9765 sales@th.idec.com Australia IDEC Australia Pty. Ltd. Tel: +61-3-8523-5900 sales@au.idec.com Taiwan IDEC Taiwan Corporation Tel: +886-2-2698-3929 service@tw.idec.com China/Shanghai IDEC (Shanghai) Corporation Tel: +86-21-6135-1515 idec@cn.idec.com China/Shenzhen IDEC (Shenzhen) Corporation Tel: +86-755-8356-2977 idec@cn.idec.com China/Beijing IDEC (Beijing) Corporation Tel: +86-10-6581-6131 idec@cn.idec.com Japan IDEC Corporation Tel: +81-6-6398-2527 marketing@idec.co.jp Speci/f_ications and other descriptions in this brochure are subject to change without notice. 2017 IDEC Corporation, All Rights Reserved. EP1430-14 JULY 2017 PRINTED IN GERMANY Head Office 6-64, Nishi-Miyahara-2-Chome, Yodogawa-ku, Osaka 532-0004, Japan