Technical content
Key Features: 3W Output Power Wide 4:1 Inputs Miniature SMT Case Tight Line/Load Regulation 1,500 VDC Isolation -40ºC to +71ºC Operation 14 Standard Models 1.0 MH MTBF Minimum Industry Standard Pin-Out LF300RU Very Wide Input, 3W SMT Single & Dual Output DC/DC Con vert ers Series MicroPower Direct
292 Page Street
Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com Electrical Specifi cations Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice. Input Parameter Conditions Min. Typ. Max. Units Reverse Polarity Input Current 1.0 A Short Circuit Input Power 2,000 mW Input Filter π (Pi) Filter (Meets EN55022 Class A) Output Parameter Conditions Min. Typ. Max. Units Output Voltage Accuracy ±0.5 ±1.0 % Output Voltage Balance Dual Output, Balanced Load ±0.5 ±2.0 % Line Regulation For Vin = Min to Max ±0.2 ±1.0 % Load Regulation Iout = 10% to 100% ±0.3 ±1.0 % Ripple & Noise (20 MHz) (Note 1) 50 75 mV P - P Ripple & Noise (20 MHz) 100 mV P - P Ripple & Noise (20 MHz) 15 mV rms Output Power Protection 120 % Transient Response Time (Note 2) 25% Load Step Change 150 500 µS Transient Response Deviation ±2 ±6 % Temperature Coeffi cient ±0.01 ±0.02 %/ºC Output Short Circuit Continuous (Autorecovery) General Parameter Conditions Min. Typ. Max. Units Isolation Voltage 60 Seconds 1,500 VDC Isolation Resistance 1,000 VDC 1,000 MΩ Isolation Capacitance 100 kHz, 1V 350 500 pF Switching Frequency 300 kHz Environmental Parameter Conditions Min. Typ. Max. Units Operating Temperature Range Ambient -40 +25 +71 ºC Operating Temperature Range Case -40 +90 ºC Storage Temperature Range -40 +125 ºC Cooling Free Air Convection Humidity RH, Non-condensing 95 % Physical Case Material Non-Conductive Black Plastic (UL94-V0) Weight 0.31 Oz (8.8g) Reliability Specifi cations Parameter Conditions Min. Typ. Max. Units MTBF MIL HDBK 217F, 25ºC, Gnd Benign 1.0 MHours Absolute Maximum Ratings Parameter Conditions Min. Typ. Max. Units Input Voltage Surge (1 Sec) 24 VDC Input -0.7 50.0 VDC48 VDC Input -0.7 100.0 Lead Temperature 1.5 mm From Case For 10 Sec. 260 ºC Internal Power Dissipation All Models 2,500 mW Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. RoHS Compliant
3 On/Off On/Off
10 NC Common
11 NC NC
12 NC -Vout
14 NC NC
22 NC NC
NC: No Connection Model Number Input Output Refl ected Ripple Cur. (mA) Effi ciency (%, Typ) Fuse Rating Slow-Blow (mA) Voltage (VDC) Current (mA) Voltage (VDC) Current (mA, Max) Current (mA, Min)Nominal Range Full-Load No-Load LF301RU 24 9.0 - 36.0 138 20 3.3 750 75.0 10 75 1,000 LF302RU 24 9.0 - 36.0 158 20 5.0 600 60.0 10 79 1,000 LF303RU 24 9.0 - 36.0 154 20 12.0 250 25.0 10 81 1,000 LF304RU 24 9.0 - 36.0 154 20 15.0 200 27.0 10 81 1,000 LF305RU 24 9.0 - 36.0 160 20 ±5.0 ±300 ±30.0 10 78 1,000 LF306RU 24 9.0 - 36.0 154 20 ±12.0 ±125 ±12.5 10 81 1,000 LF307RU 24 9.0 - 36.0 154 20 ±15.0 ±100 ±10.0 10 81 1,000 LF311RU 48 18.0 - 75.0 68 10 3.3 750 75.0 5 76 500 LF312RU 48 18.0 - 75.0 78 10 5.0 600 60.0 5 80 500 LF313RU 48 18.0 - 75.0 75 10 12.0 250 25.0 5 83 500 LF314RU 48 18.0 - 75.0 75 10 15.0 200 27.0 5 83 500 LF315RU 48 18.0 - 75.0 78 10 ±5.0 ±300 ±30.0 5 80 500 LF316RU 48 18.0 - 75.0 75 10 ±12.0 ±125 ±12.5 5 83 500 LF317RU 48 18.0 - 75.0 75 10 ±15.0 ±100 ±10.0 5 83 500 MicroPower Direct www.micropowerdirect.com 292 Page Street Ste D Stoughton, MA 02072 TEL: (781) 344-8226 FAX: (781) 344-8481 E-Mail: sales@micropowerdirect.com Model Selection Guide Mechanical Dimensions Notes: 1. When measuring output ripple, it is recommended that an external 0.47 µF ceramic capacitor be placed from the +Vout pin to the -Vout pin for single output units and from each output to common for dual output units. For noise sensitive applications, the use of 3.3 µF capacitors will reduce the output ripple. 2. Transient recovery is measured to within a 1% error band for a load step change of 75% to 100%. 3. No-load operation will not damage these units, however, they may not meet specifi ca- tions. 4. Dual output units may provide a 10V, 24V or 30V output. To do this, connect the load across the positive (+Vout) and negative (-Vout) outputs and fl oat the output common. 5. The converter should be connected to a low ac-impedance source. An input source with a highly inductive impedance may affect the stability of the converter. In applications where the converter output loading is high and input power is supplied over long lines, it may be necessary to use a capacitor on the input to insure start-up. In this case, it is recommended that a low ESR (ESR <1.0Ω at 100 kHz) capacitor be mounted close to the converter. For 24V input units a 4.7 µF is recommended, and for 48V units a 2.2 µF. 6. Maximum capacitive load for single output units is 3,000 µF, for dual output models it is 180 µF for each output. 7. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the correct rating. Remote ON/OFF Notes: 1. Maximum sink current at the on/off pin (pin 1) during a logic low is 300 µA. 2. Maximum allowable leakage current of a switch connected to the on/off terminal (Pin 1) at logic high (2.5V to 100V) is 200 µA. Parameter Condition Units Supply On 2.5 to 5.5 or Open Circuit VDC Supply Off -0.7 to 0.8 VDC Standby Input Current 10 mA Control Common Referenced to Negative Input (-Vin) Remote ON/OFF Notes: All dimensions are typical in inches (mm) Tolerance x.xx = ±0.01 (±0.25) Pin 1 is marked by a “dot” or indentation on the unit